RF Exposure evaluation

Product Description: Truly Wire Free Earbuds
Model Number: IAEB408
FCC ID: 2AHI6NIAEB408

According to 447498 D01 General RF Exposure Guidance v05 The 1-g and 10-g SAR test
exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are
determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test
separation distance, mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,
where
  f(GHz) is the RF channel transmit frequency in GHz
 Power and distance are rounded to the nearest mW and mm before calculation



According to the follow transmitter output power(Pt)formula:
Pt=(E x d)2/(30 x gt)
Pt=transmitter output power in watts
gt=numeric gain of the transmitting antenna (unitess)
E=electric field strength in V/m
d=measurement distance in meters (m)


 According to the formula described above:
 Emax=90.34dBuv/m=0.033V/m, d=3m, gt=0.86

 Pt=(E x d)2/(30 x gt)=(0.033x3)2 / (30x0.86) =0.00037989W=0.38mW



  The result is rounded to one decimal place for comparison

  Worse case is as below: [2402MHz- 0.38mW output power]

  (0.38mW / 5mm)*[√2.402GHz)] = 0.12 <3.0 for 1 - g SAR

  Then SAR evaluation is not required