RF Exposure

FCC ID: 2AHCR-VPR48G433

RF Exposure Info

Download: PDF
FCCID_4107002

Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: RXM180614051-00A

FCC §15.247 (i) & §1.1310 & §2.1091- MAXIMUM PERMISSIBLE
EXPOSURE(MPE)
Applicable Standard
According to subpart 15.247(i)and subpart §1.1310, systems operating under the provisions of this section
shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in
excess of the Commission’s guidelines.

Limits for Maximum Permissible Exposure (MPE) (§1.1310, §2.1091)

(B) Limits for General Population/Uncontrolled Exposure
Frequency Range      Electric Field      Magnetic Field           Power Density           Averaging Time
(MHz)                Strength (V/m)      Strength (A/m)           (mW/cm2)                (minutes)
0.3–1.34             614                 1.63                     *(100)                  30
1.34–30              824/f               2.19/f                   *(180/f²)               30
30–300               27.5                0.073                    0.2                     30
300–1500             /                   /                        f/1500                  30
1500–100,000         /                   /                        1.0                     30

f = frequency in MHz; * = Plane-wave equivalent power density;

According to §1.1310 and §2.1091 RF exposure is calculated.


Calculated Formulary:

Predication of MPE limit at a given distance
S = PG/4R² = power density (in appropriate units, e.g. mW/cm2);
P = power input to the antenna (in appropriate units, e.g., mW);
G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain
factor, is normally numeric gain;
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm);


Calculated Data:

                       Antenna Gain         Tune-up Power        Evaluation       Power
     Frequency                                                                                MPE Limit
                                                                  Distance       Density
       (MHz)        (dBi)   (numeric)      (dBm)     (mW)                                     (mW/cm2)
                                                                    (cm)        (mW/cm2)
     2412-2462        2         1.58          20      100.00       20.00          0.0315           1.0
     2402-2480        2         1.58          4.5      2.82        20.00          0.0009           1.0


Result: The device meet FCC MPE at 20 cm distance