Test Report

FCC ID: 2AHCR-R29X

Test Report

Download: PDF
FCCID_3920445

                                             FCC PART 15C

                                             TEST REPORT
                                                              For


        AKUVOX (XIAMEN) NETWORKS CO., LTD.
                                  10/F, No.56, Software Park II , Xiamen, China


                                          FCC ID: 2AHCR-R29X



            Report Type:                                 Product Name:
            Original Report                              Door Phone



                  Report Number:           RXM180313068-00B


                      Report Date:         2018-07-11
                                           Jerry Zhang
                                           EMC Manager
                     Reviewed By:

                 Test Laboratory:          Bay Area Compliance Laboratories Corp. (Dongguan)
                                           No.69 Pulongcun, Puxinhu Industry Area,
                                           Tangxia, Dongguan, Guangdong, China
                                           Tel: +86-769-86858888
                                           Fax: +86-769-86858891
                                           www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
      used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). This report must
      not be used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the
      Federal Government. * This report may contain data that are not covered by the A2LA accreditation and are marked with
      an asterisk “*”.


  Bay Area Compliance Laboratories Corp. (Dongguan)                                                                        Report No.: RXM180313068-00B




                                                       TABLE OF CONTENTS

GENERAL INFORMATION .......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 MEASUREMENT UNCERTAINTY ....................................................................................................................................4
 TEST FACILITY .............................................................................................................................................................4
SYSTEM TEST CONFIGURATION ..........................................................................................................................5
  JUSTIFICATION .............................................................................................................................................................5
  EUT EXERCISE SOFTWARE ..........................................................................................................................................5
  SUPPORT EQUIPMENT LIST AND DETAILS ....................................................................................................................5
  SUPPORT CABLE LIST AND DETAILS ............................................................................................................................5
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................6
SUMMARY OF TEST RESULTS ...............................................................................................................................7
FCC§15.203 - ANTENNA REQUIREMENT..............................................................................................................8
  APPLICABLE STANDARD ..............................................................................................................................................8
  ANTENNA CONNECTED CONSTRUCTION ......................................................................................................................8
FCC §15.207 – AC LINE CONDUCTED EMISSION ...............................................................................................9
  EUT SETUP ..................................................................................................................................................................9
  EMI TEST RECEIVER SETUP .........................................................................................................................................9
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................10
  TEST PROCEDURE ......................................................................................................................................................10
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................10
  TEST RESULTS SUMMARY ..........................................................................................................................................11
  TEST DATA ................................................................................................................................................................11
FCC§15.225, §15.205 & §15.209 - RADIATED EMISSIONS TEST ......................................................................16
  APPLICABLE STANDARD ............................................................................................................................................16
  EUT SETUP ................................................................................................................................................................17
  EMI TEST RECEIVER SETUP .......................................................................................................................................17
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................17
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................18
  TEST RESULTS SUMMARY ..........................................................................................................................................18
  TEST DATA ................................................................................................................................................................18
FCC§15.225(E) - FREQUENCY STABILITY..........................................................................................................24
  APPLICABLE STANDARD ............................................................................................................................................24
  TEST PROCEDURE ......................................................................................................................................................24
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................24
  TEST DATA ................................................................................................................................................................24
FCC §15.215(C) – 20 DB EMISSION BANDWIDTH ..............................................................................................26
  APPLICABLE STANDARD ............................................................................................................................................26
  TEST PROCEDURE ......................................................................................................................................................26
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................26
  TEST DATA ................................................................................................................................................................27



                                                                                                                                                            Page 2 of 28


 Bay Area Compliance Laboratories Corp. (Dongguan)                                 Report No.: RXM180313068-00B

GENERAL INFORMATION
Product Description for Equipment Under Test (EUT)

                           EUT Name:         Door Phone
                           EUT Model:        R29F
                      Multiple Models:       R29S
                               FCC ID:       2AHCR-R29X
                   Rated Input Voltage:      DC12V from DC port or PoE port
                   External Dimension:       324mm(L)*130mm(W)*27mm(H)
                        Serial Number:       180313068-1(Model:R29F), 180313068-2(Model:R29S)
                   EUT Received Date:        2018.03.19

Note: The series product, model R29F, R29S are electrically identical, we selected R29F for fully testing, the
differences details was explained in the declaration letter.


Objective
This Type approval report is prepared on behalf of AKUVOX (XIAMEN) NETWORKS CO., LTD. in
accordance with Part 2, Subpart J, and Part 15, Subparts A and C of the Federal Communications
Commission’s rules.

The objective is to determine the compliance of the EUT with FCC rules, sec 15.203, 15.205, 15.207,
15.209, 15.215 and 15.225.


Related Submittal(s)/Grant(s)
N/A


Test Methodology
All measurements detailed in this Test Report were performed in accordance with ANSI C63.10-2013
“American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices”.

All emissions measurement was performed and Bay Area Compliance Laboratories Corp. (Dongguan).
The radiated testing was performed at an antenna-to-EUT distance of 3 meters.




                                                                                                          Page 3 of 28


 Bay Area Compliance Laboratories Corp. (Dongguan)                        Report No.: RXM180313068-00B

Measurement Uncertainty
               Parameter                                Measurement Uncertainty
       Occupied Channel Bandwidth                                  ±5 %
                                                          9kHz~30MHz: 4.12dB
            radiated Emissions             30M~200MHz: 4.58 dB for Horizontal, 4.59 dB for Vertical
                                            200M~1GHz: 4.83 dB for Horizontal, 5.85 dB for Vertical
              Temperature                                          ±1℃
                Humidity                                           ±5%
      DC and low frequency voltages                               ±0.4%
               Duty Cycle                                           1%
       AC Power Lines Conducted                          3.12 dB (150 kHz to 30 MHz)
                Emission



Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located
on the No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China.

The test site has been approved by the FCC under the KDB 974614 D01 and is listed in the FCC Public
Access Link (PAL) database, FCC Registration No. : 897218,the FCC Designation No. : CN1220.

The test site has been registered with ISED Canada under ISED Canada Registration Number 3062D.




                                                                                               Page 4 of 28


 Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: RXM180313068-00B

SYSTEM TEST CONFIGURATION
Justification

The system was configured for testing in a test mode

The device operates simultaneously in 125 kHz and 13.56 MHz for RFID detection.


EUT Exercise Software

No software used in test.


Support Equipment List and Details

        Manufacturer                    Description                Model                Serial Number

            L.T.E.                  AC/DC Adapter             G0548B-480-050                N/A

          HUAWEI                     PoE Adapter             HW-120200U6W                   N/A
            RSD                     Button Switch                KCD1                       N/A
            Lotus                   Entrance guard              L8MF-W                      N/A
          Schneider                     Relay                 RXM2LB2BD                     N/A
          TP-LINK                       Switch                 TL-SF1008P              114A297001782
           Tenda                        router                    D301               E3941017710003629


Support Cable List and Details

                            Shielding
   Cable Description                        Ferrite Core   Length (m)      From Port              To
                              Type
      RJ45 Cable               No               No             5           EUT or PoE            router
      Signal Cable             No               No             5             EUT             Button Switch
                                                                                               Entrance
      Signal Cable             No               No             5               EUT
                                                                                                 guard
     RS485 Cable               No               No             5               EUT              Switch
     Signal Cable              No               No             5               EUT               Relay
     RJ45 Cable                No               No             1               EUT                PoE




                                                                                                  Page 5 of 28


 Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RXM180313068-00B

Block Diagram of Test Setup
AC/DC Adapter supply




PoE supply




                                                                       Page 6 of 28


Bay Area Compliance Laboratories Corp. (Dongguan)                    Report No.: RXM180313068-00B

SUMMARY OF TEST RESULTS

             FCC Rules                       Description of Test               Result

              §15.203                       Antenna Requirement             Compliance
              §15.207                   AC Line Conducted Emission          Compliance
              §15.225
                                           Radiated Emission Test           Compliance
          §15.209 §15.205
             §15.225(e)                      Frequency Stability            Compliance
             §15.215(c)                   20 dB Emission Bandwidth          Compliance




                                                                                         Page 7 of 28


 Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RXM180313068-00B

FCC§15.203 - ANTENNA REQUIREMENT
Applicable Standard
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
responsible party shall be used with the device. The use of a permanently attached antenna or of an
antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with
the provisions of this section.


Antenna Connected Construction
The EUT has two integral antenna arrangement, one for 13.56MHz, one for 125kHz, which was
permanently attached and fulfill the requirement of this section. Please refer to the EUT photos.

Result: Compliance.




                                                                                                 Page 8 of 28


 Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RXM180313068-00B

FCC §15.207 – AC LINE CONDUCTED EMISSION

EUT Setup




The setup of EUT is according with per ANSI C63.10-2013 measurement procedure. The specification
used was with the FCC Part 15.207 limits.

The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the
middle.

The spacing between the peripherals was 10 cm.

The adapter was connected to the main LISN with an AC 120V/60Hz power source.


EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

                              Frequency Range                      IF B/W
                              150 kHz – 30 MHz                      9 kHz




                                                                                               Page 9 of 28


 Bay Area Compliance Laboratories Corp. (Dongguan)                                Report No.: RXM180313068-00B

Test Equipment List and Details

                                                                     Serial         Calibration   Calibration
      Manufacturer              Description           Model
                                                                    Number             Date        Due Date
           R&S               EMI Test Receiver      ESCS 30        830245/006       2017-12-11     2018-12-11
           R&S              Two-line V-network      ENV 216          101614         2017-12-08     2018-12-08
           N/A                 Coaxial Cable       C-NJNJ-50        C-0200-01       2017-09-05     2018-09-05
           R&S                 Test Software         EMC32        Version8.53.0        N/A            N/A

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).


Test Procedure
During the conducted emission test, the adapter or POE was connected to the outlet of the LISN.
Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All data was recorded in the Quasi-peak and average detection mode.

According FCC publication number 174176,for a device with a permanent antenna operating at or below
30 MHz, the measurements done with a suitable dummy load, in lieu of the permanent antenna under the
following conditions: (1) perform the AC line conducted tests with the permanent antenna to determine
compliance with the Section 15.207 limits outside the transmitter's fundamental emission band; (2) retest
with a dummy load in lieu of the permanent antenna to determine compliance with the Section 15.207
limits within the transmitter's fundamental emission band.


Corrected Amplitude & Margin Calculation
The basic equation is as follows:

VC = VR + AC + VDF

Herein,
VC: corrected voltage amplitude
VR: reading voltage amplitude

Ac: attenuation caused by cable loss

VDF: voltage division factor of AMN or ISN

The “Margin” column of the following data tables indicates the degree of compliance within the
applicable limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation
for margin calculation is as follows:

                                    Margin = Limit – Corrected Amplitude




                                                                                                    Page 10 of 28


 Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RXM180313068-00B

Test Results Summary
According to the recorded data in following table, the EUT complied with the FCC Part 15.207.


Test Data
    Environmental Conditions

              Temperature:           26.9 C
         Relative Humidity:           61 %
            ATM Pressure:           101 kPa

      The testing was performed by Sider Huang on 2018-05-02.




                                                                                           Page 11 of 28


 Bay Area Compliance Laboratories Corp. (Dongguan)                                         Report No.: RXM180313068-00B

Test mode: Transmitting (R29F was the worst)

Test Mode: AC/DC Adapter supply
AC 120V, 60 Hz, Line:


                         80

                         70
                                                                                                   Quasi-Peak Limit
                         60

                                                                                                      Average Limit
                         50
          Level in dBμ




                         40

                         30

                         20

                         10

                         0
                         150k      300   400 500     800 1M        2M     3M     4M 5M 6   8 10M         20M     30M
                                                               Frequency in Hz



     Frequency                  Quasi Peak         Bandwidth               Corr.      Margin    Limit
                                                                  Line                                         Comment
       (MHz)                     (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.158604                     53.1              9.000         L1      11.1        12.4      65.5          Compliance
      0.188994                     51.1              9.000         L1      10.7        13.0      64.1          Compliance
      0.415949                     41.9              9.000         L1      10.0        15.6      57.5          Compliance
      0.446873                     40.5              9.000         L1       9.9        16.4      56.9          Compliance
      1.239175                     42.1              9.000         L1       9.8        13.9      56.0          Compliance
      1.269154                     37.8              9.000         L1       9.8        18.2      56.0          Compliance

     Frequency                   Average           Bandwidth               Corr.      Margin    Limit
                                                                  Line                                         Comment
       (MHz)                     (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.184529                     46.8              9.000         L1      10.8         7.5      54.3          Compliance
      0.288307                     36.3              9.000         L1      10.2        14.3      50.6          Compliance
      0.415949                     35.5              9.000         L1      10.0        12.0      47.5          Compliance
      0.443327                     32.7              9.000         L1       9.9        14.3      47.0          Compliance
      1.239175                     37.3              9.000         L1       9.8         8.7      46.0          Compliance
      1.259081                     35.3              9.000         L1       9.8        10.7      46.0          Compliance




                                                                                                                  Page 12 of 28


 Bay Area Compliance Laboratories Corp. (Dongguan)                                         Report No.: RXM180313068-00B

AC120 V, 60 Hz, Neutral:


                         80

                         70
                                                                                                   Quasi-Peak Limit
                         60

                                                                                                      Average Limit
                         50
          Level in dBμ




                         40

                         30

                         20

                         10

                         0
                         150k      300   400 500     800 1M        2M     3M     4M 5M 6   8 10M         20M     30M
                                                               Frequency in Hz



     Frequency                  Quasi Peak         Bandwidth               Corr.      Margin    Limit
                                                                  Line                                         Comment
       (MHz)                     (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.173134                     50.1              9.000         N       10.9        14.7      64.8          Compliance
      0.409372                     41.8              9.000         N       10.0        15.9      57.7          Compliance
      0.450448                     41.3              9.000         N        9.9        15.6      56.9          Compliance
      0.665597                     37.7              9.000         N        9.8        18.3      56.0          Compliance
      1.209904                     41.0              9.000         N        9.8        15.0      56.0          Compliance
      1.249088                     40.8              9.000         N        9.8        15.2      56.0          Compliance

     Frequency                   Average           Bandwidth               Corr.      Margin    Limit
                                                                  Line                                         Comment
       (MHz)                     (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.186006                     46.5              9.000         N       10.7         7.7      54.2          Compliance
      0.286019                     37.2              9.000         N       10.2        13.4      50.6          Compliance
      0.402900                     35.2              9.000         N       10.0        12.6      47.8          Compliance
      0.450448                     37.0              9.000         N        9.9         9.9      46.9          Compliance
      1.239175                     35.2              9.000         N        9.8        10.8      46.0          Compliance
      1.259081                     35.1              9.000         N        9.8        10.9      46.0          Compliance




                                                                                                                  Page 13 of 28


 Bay Area Compliance Laboratories Corp. (Dongguan)                                         Report No.: RXM180313068-00B

Test Mode: PoE Power supply
AC 120V, 60 Hz, Line:


                         80

                         70

                                                                                                   Quasi-Peak Limit
                         60
                                                                                                      Average Limit
                         50
          Level in dBμ




                         40

                         30

                         20

                         10

                         0
                         150k      300   400 500     800 1M        2M     3M     4M 5M 6   8 10M         20M     30M

                                                               Frequency in Hz



     Frequency                  Quasi Peak         Bandwidth               Corr.      Margin    Limit
                                                                  Line                                         Comment
       (MHz)                     (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.150000                     57.3              9.000         L1      11.2         8.7      66.0          Compliance
      0.153629                     56.1              9.000         L1      11.1         9.7      65.8          Compliance
      0.187494                     54.3              9.000         L1      10.7         9.8      64.1          Compliance
      0.384091                     44.0              9.000         L1      10.0        14.2      58.2          Compliance
      0.429420                     44.9              9.000         L1       9.9        12.4      57.3          Compliance
      0.472507                     47.0              9.000         L1       9.9         9.5      56.5          Compliance

     Frequency                   Average           Bandwidth               Corr.      Margin    Limit
                                                                  Line                                         Comment
       (MHz)                     (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.190505                     43.0              9.000         L1      10.7        11.0      54.0          Compliance
      0.381043                     37.5              9.000         L1      10.0        10.8      48.3          Compliance
      0.426011                     39.5              9.000         L1       9.9         7.8      47.3          Compliance
      0.476287                     41.6              9.000         L1       9.9         4.8      46.4          Compliance
      1.219583                     33.8              9.000         L1       9.8        12.2      46.0          Compliance
     13.422446                     38.6              9.000         L1       9.9        11.4      50.0          Compliance




                                                                                                                  Page 14 of 28


 Bay Area Compliance Laboratories Corp. (Dongguan)                                         Report No.: RXM180313068-00B

AC120 V, 60 Hz, Neutral:


                         80

                         70
                                                                                                   Quasi-Peak Limit
                         60

                                                                                                      Average Limit
                         50
          Level in dBμ




                         40

                         30

                         20

                         10

                         0
                         150k      300   400 500     800 1M        2M     3M     4M 5M 6   8 10M         20M     30M
                                                               Frequency in Hz



     Frequency                  Quasi Peak         Bandwidth               Corr.      Margin    Limit
                                                                  Line                                         Comment
       (MHz)                     (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.150000                     57.1              9.000         N       11.2         8.9      66.0          Compliance
      0.183065                     52.1              9.000         N       10.8        12.2      64.3          Compliance
      0.375019                     44.6              9.000         N       10.0        13.8      58.4          Compliance
      0.412647                     42.7              9.000         N       10.0        14.9      57.6          Compliance
      0.480097                     46.5              9.000         N        9.9         9.8      56.3          Compliance
     13.210237                     44.4              9.000         N        9.9        15.6      60.0          Compliance

     Frequency                   Average           Bandwidth               Corr.      Margin    Limit
                                                                  Line                                         Comment
       (MHz)                     (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.193566                     42.8              9.000         N       10.7        11.1      53.9          Compliance
      0.384091                     33.2              9.000         N       10.0        15.0      48.2          Compliance
      0.432855                     39.4              9.000         N        9.9         7.8      47.2          Compliance
      0.480097                     35.0              9.000         N        9.9        11.3      46.3          Compliance
      1.239175                     34.7              9.000         N        9.8        11.3      46.0          Compliance
     13.529825                     38.2              9.000         N        9.9        11.8      50.0          Compliance




                                                                                                                  Page 15 of 28


 Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RXM180313068-00B

FCC§15.225, §15.205 & §15.209 - RADIATED EMISSIONS TEST
Applicable Standard
FCC Part 15.205, 15.209, 15.225
(a) The field strength of any emissions within the band 13.553–13.567 MHz shall not exceed 15,848
    microvolts/meter at 30 meters.
(b) Within the bands 13.410–13.553 MHz and 13.567–13.710 MHz, the field strength of any emissions
    shall not exceed 334 microvolts/meter at 30 meters.
(c) Within the bands 13.110–13.410 MHz and 13.710–14.010 MHz the field strength of any emissions
    shall not exceed 106 microvolts/meter at 30 meters.

(d) The field strength of any emissions appearing outside of the 13.110–14.010 MHz band shall not exceed
    the general radiated emission limits in §15.209.
As per FCC Part 15.209

 (a) Except as provided elsewhere in this subpart, the emissions from an intentional radiator shall not
exceed the field strength levels specified in the following table:

  Frequency (MHz)            Field strength (microvolts/meter)         Measurement distance (meters)
0.009-0.490             2400/F(kHz)                                                                       300
0.490-1.705             24000/F(kHz)                                                                       30
1.705-30.0              30                                                                                 30
30-88                   100**                                                                              3
88-216                  150**                                                                              3
216-960                 200**                                                                              3
Above 960               500                                                                                3
      **Except as provided in paragraph (g), fundamental emissions from intentional radiators operating
under this section shall not be located in the frequency bands 54-72 MHz, 76-88 MHz, 174-216 MHz or
470-806 MHz. However, operation within these frequency bands is permItted under other sections of this
part, e.g., §§15.231 and 15.241.




                                                                                                Page 16 of 28


 Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RXM180313068-00B


EUT Setup




The radiated emission tests were performed in the 3-meter chamber test site, using the setup accordance
with the ANSI C63.10-2013. The specification used was the FCC Part Subpart C limits.

The spacing between the peripherals was 10 cm.


EMI Test Receiver Setup
The system was investigated from 9 kHz to 1 GHz.

During the radiated emission test, the EMI test Receiver was set with the following configurations:

                      Frequency Range            RBW          Video B/W      Measurement
                      9 kHz – 150 kHz            200 Hz          1 kHz            QP
                     150 kHz – 30 MHz            9 kHz          30 kHz            QP
                    30 MHz – 1000 MHz           120 kHz         300 kHz           QP

If the maximized peak measured value complies with the limit, then it is unnecessary to perform an
QP/Average measurement


Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Amplitude reading. The basic equation is as follows:

                 Corr. Ampl. = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

                                        Margin = Limit - Corr. Ampl.


                                                                                              Page 17 of 28


 Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RXM180313068-00B

Test Equipment List and Details

                                                                     Serial        Calibration   Calibration
    Manufacturer            Description             Model
                                                                    Number            Date        Due Date
    Sunol Sciences            Antenna                JB3          A060611-1        2017-11-10    2020-11-10
        R&S             EMI Test Receiver            ESCI           100224         2017-12-11    2018-12-11
         HP                   Amplifier             8447D         2727A05902       2017-09-05    2018-09-05
       EMCO                 Passive Loop             6512          9706-1206       2017-03-05    2020-03-04
      Unknown               Coaxial Cable         C-NJNJ-50        C-0400-01       2017-09-05    2018-09-05
      Unknown               Coaxial Cable         C-NJNJ-50        C-0075-01       2017-09-05    2018-09-05
      Unknown               Coaxial Cable         C-NJNJ-50        C-1000-01       2017-09-05    2018-09-05
        Farad               Test Software           EZ-EMC          V1.1.4.2          N/A            N/A

   * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
    have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Results Summary
According to the data in the following table, the EUT complied with the FCC Part 15.209&15.225.


Test Data
    Environmental Conditions

            Temperature:             27~29.6 oC
       Relative Humidity:               35~38 %
          ATM Pressure:             101.3~102 kPa

     * The testing was performed by Blake Yang from 2018-04-28 to 2018-05-31.

Test mode: Transmitting(AC/DC adapter R29F was the worst)




                                                                                                   Page 18 of 28


 Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RXM180313068-00B

1) 9 kHz~30MHz:




                       Receiver                 Correction     Cord.
        Frequency                                                          Limit      Margin
                       Reading      Detector     Factor        Amp.
          (MHz)                                                          (dBμV/m)      (dB)
                       (dBμV)                    (dB/m)      (dBμV/m)
          0.0217         7.35         peak        55.25        62.60       120.87      58.27
          0.0313         10.98        peak           52.18    63.16        117.69      54.53
          0.1246         49.98        peak           40.49    90.47        105.69      15.22




                                                                                         Page 19 of 28


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RXM180313068-00B




                      Receiver                 Correction     Cord.
       Frequency                                                          Limit      Margin
                      Reading      Detector     Factor        Amp.
         (MHz)                                                          (dBμV/m)      (dB)
                      (dBμV)                    (dB/m)      (dBμV/m)
         0.6873        20.94         peak        24.86        45.80       70.86       25.06
         1.6127        27.72         peak        18.38        46.10       63.44       17.34
         2.0306         26.62        peak           16.08    42.70        69.54       26.84
         3.1051         36.16        peak           13.14    49.30        69.54       20.24
         4.7171         40.01        peak           10.89    50.90        69.54       18.64
         7.8810         23.15        peak           9.65     32.80        69.54       36.74




                                                                                        Page 20 of 28


 Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RXM180313068-00B

Fundamental:




                       Receiver                 Correction     Cord.
        Frequency                                                          Limit      Margin
                       Reading      Detector     Factor        Amp.
          (MHz)                                                          (dBμV/m)      (dB)
                       (dBμV)                    (dB/m)      (dBμV/m)
         13.5617        60.93         peak         9.29        70.22       124.00      53.78




                                                                                         Page 21 of 28


 Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RXM180313068-00B

2) Above 30 MHz

Horizontal




                       Receiver                 Correction     Cord.
        Frequency                                                          Limit      Margin
                       Reading      Detector     Factor        Amp.
          (MHz)                                                          (dBμV/m)      (dB)
                       (dBμV)                    (dB/m)      (dBμV/m)
         30.0000        24.86          QP          1.54        26.40       40.00       13.60
         122.1500       31.12          QP         -4.82        26.30       43.50       17.20
         230.7900        38.02         QP            -6.52    31.50        46.00       14.50
         359.8000        36.35         QP            -2.85    33.50        46.00       12.50
         384.0500        36.97         QP            -2.47    34.50        46.00       11.50
         480.0800        37.04         QP            -0.34    36.70        46.00       9.30




                                                                                         Page 22 of 28


 Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RXM180313068-00B

Vertical




                          Receiver                   Correction     Cord.
           Frequency                                                             Limit      Margin
    No.                   Reading      Detector       Factor        Amp.
             (MHz)                                                             (dBμV/m)      (dB)
                          (dBμV)                      (dB/m)      (dBμV/m)
     1      52.3100        40.69          QP           -11.89       28.80        40.00       11.20
     2      122.1500       35.02          QP            -4.82       30.20        43.50       13.30
     3      148.3400        36.24         QP           -6.04       30.20         43.50       13.30
     4      395.6900        39.72         QP           -2.12       37.60         46.00        8.40
     5      463.5900        41.90         QP           -0.70       41.20         46.00        4.80
     6      926.2800        33.50         QP            6.60       40.10         46.00       5.90




                                                                                            Page 23 of 28


 Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RXM180313068-00B

FCC§15.225(e) - FREQUENCY STABILITY
Applicable Standard
The frequency tolerance of the carrier signal shall be maintained within ±0.01% of the operating frequency
over a temperature variation of −20 degrees to +50 degrees C at normal supply voltage, and for a variation
in the primary supply voltage from 85% to 115% of the rated supply voltage at a temperature of 20 degrees
C. For battery operated equipment, the equipment tests shall be performed using a new battery.


Test Procedure
Frequency Stability vs. Temperature: The equipment under test was connected to an external DC power.

The EUT was placed inside the temperature chamber.
After the temperature stabilized for approximately 20 minutes, the frequency output was recorded from the
Spectrum Analyzer.

Frequency Stability vs. Voltage: An external variable DC power supply Source. The voltage was set to the
end point of the battery. The output frequency was recorded for each voltage.


Test Equipment List and Details

                                                                      Serial        Calibration   Calibration
     Manufacturer           Description             Model
                                                                     Number            Date        Due Date
         R&S             EMI Test Receiver          ESCI             100224         2017-12-11     2018-12-11
          HP                  Amplifier             8447D          2727A05902       2017-09-05     2018-09-05
        EMCO                Passive Loop             6512           9706-1206       2017-03-05     2020-03-04
       Unknown              Coaxial Cable         C-NJNJ-50         C-0400-01       2017-09-05     2018-09-05
       Unknown              Coaxial Cable         C-NJNJ-50         C-0075-01       2017-09-05     2018-09-05
       Unknown              Coaxial Cable         C-NJNJ-50         C-1000-01       2017-09-05     2018-09-05
         UNI-T              Multimeter             UT39A           M130199938       2018-05-09     2019-05-09
                         High Temperature
      Dongzhixu                                    DP1000          201105083-4      2017-08-28     2018-08-28
                           Test Chamber
       Schneider         AC Power Supply           YF6005              005              N/A           N/A

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).

Test Data
     Environmental Conditions

             Temperature:                 27 oC
       Relative Humidity:                 35 %
           ATM Pressure:              101.3 kPa

     * The testing was performed by Blake Yang on 2018-05-31.

                                                                                                    Page 24 of 28


 Bay Area Compliance Laboratories Corp. (Dongguan)                        Report No.: RXM180313068-00B

   Test Mode: Transmitting

   Test Result: Pass

AC/DC adapter:

                                             fo = 13.56 MHz
                                              Measured
               Temperature      Voltage                       Frequency Error     Limit
                                              frequency
                    ℃             VAC            MHz                Hz              Hz
                   -20                         13.56119            1190           ±1356
                   -10                         13.56114            1140           ±1356
                       0                       13.56118            1180           ±1356
                    10                         13.56117            1170           ±1356
                    20           120 V         13.56115            1150           ±1356
                    25                         13.56117            1170           ±1356
                    30                         13.56118            1180           ±1356
                    40                         13.56121            1210           ±1356
                    50                         13.56118            1180           ±1356
                    25            102V         13.56115            1150           ±1356
                    25            138V         13.56117            1170           ±1356

POE adapter:
                                             fo = 13.56 MHz
                                              Measured
               Temperature      Voltage                       Frequency Error     Limit
                                              frequency
                    ℃             VAC            MHz                Hz              Hz
                   -20                         13.56123            1230           ±1356
                   -10                         13.56112            1120           ±1356
                       0                       13.56115            1150           ±1356
                    10                         13.56112            1120           ±1356
                    20           120 V         13.56112            1120           ±1356
                    25                         13.56111            1110           ±1356
                    30                         13.56113            1130           ±1356
                    40                         13.56112            1120           ±1356
                    50                         13.56121            1210           ±1356
                    25            102V         13.56114            1140           ±1356
                    25            138V         13.56112            1120           ±1356




                                                                                           Page 25 of 28


 Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RXM180313068-00B

FCC §15.215(c) – 20 dB EMISSION BANDWIDTH
Applicable Standard

Per FCC §15.215 (c) Intentional radiators operating under the alternative provisions to the general
emission limits, as contained in §15.217 through § 15.257 and in Subpart E of this part, must be designed
to ensure that the 20 dB bandwidth of the emission, or whatever bandwidth may otherwise be specified in
the specific rule section under which the equipment operates, is contained within the frequency band
designated in the rule section under which the equipment is operated. The requirement to contain the
designated bandwidth of the emission within the specified frequency band includes the effects from
frequency sweeping, frequency hopping and other modulation techniques that may be employed as well as
the frequency stability of the transmitter over expected variations in temperature and supply voltage. If a
frequency stability is not specified in the regulations, it is recommended that the fundamental emission be
kept within at least the central 80% of the permitted band in order to minimize the possibility of out-of -
band operation.

Test Procedure
Measure the frequency difference of two frequencies that were attenuated 20 dB from the reference level.
Record the frequency difference as the emission bandwidth.

Test Equipment List and Details

                                                                      Serial        Calibration   Calibration
     Manufacturer           Description             Model
                                                                     Number            Date        Due Date
         R&S             EMI Test Receiver          ESCI             100224         2017-12-11     2018-12-11
          HP                  Amplifier             8447D          2727A05902       2017-09-05     2018-09-05
        EMCO                Passive Loop             6512           9706-1206       2017-03-05     2020-03-04
       Unknown             Coaxial Cable          C-NJNJ-50         C-0400-01       2017-09-05     2018-09-05
       Unknown             Coaxial Cable          C-NJNJ-50         C-0075-01       2017-09-05     2018-09-05
       Unknown             Coaxial Cable          C-NJNJ-50         C-1000-01       2017-09-05     2018-09-05

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).




                                                                                                    Page 26 of 28


 Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RXM180313068-00B

Test Data
    Environmental Conditions

            Temperature:          25.4~26.1 oC
       Relative Humidity:             25~57 %
          ATM Pressure:          100.1~100.6 kPa

     * The testing was performed by David Huang on 2018-04-27&2018-07-11.

     Test Result: Compliance.

      Please refer to following tables and plots


                         Test Frequency                         20 dB Bandwidth
                             (MHz)                                   (kHz)
                              13.56                                   1.12
                              0.125                                   0.274




                                                                                             Page 27 of 28


 Bay Area Compliance Laboratories Corp. (Dongguan)              Report No.: RXM180313068-00B

Test Mode: Transmitting
                                     20 dB Emission Bandwidth




                                  ***** END OF REPORT *****