Test Report

FCC ID: 2AHCR-R28A

Test Report

Download: PDF
FCCID_4444225

                                             FCC PART 15C

                                             TEST REPORT
                                                              For


        AKUVOX (XIAMEN) NETWORKS CO., LTD.
                                  10/F, No.56, Software Park II , Xiamen, China


                                          FCC ID: 2AHCR-R28A



            Report Type:                                 Product Name:
            Original Report                              Door Phone



                  Report Number:           RXM190515053-00A


                      Report Date:         2019-08-19
                                           Jerry Zhang
                                           EMC Manager
                     Reviewed By:

                 Test Laboratory:          Bay Area Compliance Laboratories Corp. (Dongguan)
                                           No.69 Pulongcun, Puxinhu Industry Area,
                                           Tangxia, Dongguan, Guangdong, China
                                           Tel: +86-769-86858888
                                           Fax: +86-769-86858891
                                           www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
      used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). This report must
      not be used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the
      Federal Government. * This report may contain data that are not covered by the A2LA accreditation and are marked with
      an asterisk “*”.


  Bay Area Compliance Laboratories Corp. (Dongguan)                                                                Report No.: RXM190515053-00A




                                                       TABLE OF CONTENTS

GENERAL INFORMATION .......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 MEASUREMENT UNCERTAINTY ....................................................................................................................................4
 TEST FACILITY .............................................................................................................................................................4
SYSTEM TEST CONFIGURATION ..........................................................................................................................5
  JUSTIFICATION .............................................................................................................................................................5
  EUT EXERCISE SOFTWARE ..........................................................................................................................................5
  SUPPORT EQUIPMENT LIST AND DETAILS ....................................................................................................................5
  SUPPORT CABLE LIST AND DETAILS ............................................................................................................................5
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................6
SUMMARY OF TEST RESULTS ...............................................................................................................................7
FCC§15.203 - ANTENNA REQUIREMENT..............................................................................................................8
  APPLICABLE STANDARD ..............................................................................................................................................8
  ANTENNA CONNECTED CONSTRUCTION ......................................................................................................................8
FCC §15.207 – AC LINE CONDUCTED EMISSION ...............................................................................................9
  EUT SETUP ..................................................................................................................................................................9
  EMI TEST RECEIVER SETUP .........................................................................................................................................9
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................10
  TEST PROCEDURE ......................................................................................................................................................10
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................10
  TEST RESULTS SUMMARY ..........................................................................................................................................11
  TEST DATA ................................................................................................................................................................11
FCC§15.225, §15.205 & §15.209 - RADIATED EMISSIONS TEST ......................................................................16
  APPLICABLE STANDARD ............................................................................................................................................16
  EUT SETUP ................................................................................................................................................................17
  EMI TEST RECEIVER SETUP .......................................................................................................................................17
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................18
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................18
  TEST RESULTS SUMMARY ..........................................................................................................................................18
  TEST DATA ................................................................................................................................................................19
FCC§15.225(E) - FREQUENCY STABILITY..........................................................................................................25
  APPLICABLE STANDARD ............................................................................................................................................25
  TEST PROCEDURE ......................................................................................................................................................25
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................25
  TEST DATA ................................................................................................................................................................25
FCC §15.215(C) – 20 DB EMISSION BANDWIDTH ..............................................................................................27
  APPLICABLE STANDARD ............................................................................................................................................27
  TEST PROCEDURE ......................................................................................................................................................27
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................27
  TEST DATA ................................................................................................................................................................27



                                                                                                                                                            Page 2 of 29


 Bay Area Compliance Laboratories Corp. (Dongguan)                            Report No.: RXM190515053-00A

GENERAL INFORMATION
Product Description for Equipment Under Test (EUT)

          EUT Name:         Door Phone
         EUT Model:   R28A
       Multiple Model:R28V
                      125 kHz
 Operation Frequency:
                      13.56 MHz
    Modulation Type: ASK
  Rated Input Voltage:      DC 12V from the adapter or DC 48V from PoE
  External Dimension:       280mm(L)*130mm(W)*30mm(H) 1000g
       Serial Number:       190515053
  EUT Received Date:        2019-05-17

Note: The series products models R28V is electrically identical with R28A, we selected R28A for fully testing, the
details of the difference between them were explained in the attached declaration letter.


Objective
This Type approval report is prepared on behalf of AKUVOX (XIAMEN) NETWORKS CO., LTD. in
accordance with Part 2, Subpart J, and Part 15, Subparts A and C of the Federal Communications
Commission’s rules.

The objective is to determine the compliance of the EUT with FCC rules, sec 15.203, 15.205, 15.207,
15.209, 15.215 and 15.225.


Related Submittal(s)/Grant(s)
N/A


Test Methodology
All measurements detailed in this Test Report were performed in accordance with ANSI C63.10-2013
“American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices”.

All emissions measurement was performed and Bay Area Compliance Laboratories Corp. (Dongguan).
The radiated testing was performed at an antenna-to-EUT distance of 3 meters.




                                                                                                          Page 3 of 29


 Bay Area Compliance Laboratories Corp. (Dongguan)                   Report No.: RXM190515053-00A

Measurement Uncertainty
               Parameter                                Measurement Uncertainty
       Occupied Channel Bandwidth                                 ±5 %
                                                         9kHz~30MHz: 4.12dB
            radiated Emissions
                                                 30M~200MHz: 4.55 dB, 200M~1GHz: 5.92 dB
              Temperature                                         ±1℃
                Humidity                                          ±5%
      DC and low frequency voltages                              ±0.4%
               Duty Cycle                                          1%
       AC Power Lines Conducted                          3.12 dB (150 kHz to 30 MHz)
                Emission



Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located
on the No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China.

The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the
FCC Public Access Link (PAL) database, FCC Registration No. : 897218, the FCC Designation No. :
CN1220.

The lab has been recognized by Innovation, Science and Economic Development Canada to test to
Canadian radio equipment requirements, the CAB identifier: CN0022.




                                                                                             Page 4 of 29


 Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RXM190515053-00A

SYSTEM TEST CONFIGURATION
Justification

The system was configured for testing in a test mode

The device operates in 125 kHz and 13.56 MHz simultaneously for RFID detection.


EUT Exercise Software

No software used in test.


Support Equipment List and Details

        Manufacturer                    Description                Model                  Serial Number

            Tenda                          PoE                      O2                        N/A

          HUAWEI                       Adapter               HW-120200U6W                    N/A
            RSD                     Button Switch                KCD1                        N/A
            Lotus                   Entrance Guard              L8MF-W                       N/A
          Schneider                      Relay                RXM2LB2BD                      N/A
          TP-LINK                       Switch                 TL-SF1008P               114A297001782
           Tenda                        Router                    D301                E3941017710003629


Support Cable List and Details

                            Shielding
   Cable Description                        Ferrite Core   Length (m)        From Port              To
                              Type
      RJ45 Cable               No                No            5             EUT or PoE            router
      Signal Cable             No                No            5               EUT             Button Switch
                                                                                                 Entrance
      Signal Cable             No                No            5                EUT
                                                                                                   Guard
     RS485 Cable               No                No            5                EUT               Switch
     Signal Cable              No                No            5                EUT                Relay
     RJ45 Cable                No                No            1                EUT                 PoE




                                                                                                    Page 5 of 29


 Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RXM190515053-00A

Block Diagram of Test Setup

AC/DC Adapter supply




PoE supply




                                                                           Page 6 of 29


Bay Area Compliance Laboratories Corp. (Dongguan)                    Report No.: RXM190515053-00A

SUMMARY OF TEST RESULTS

             FCC Rules                       Description of Test                   Result

              §15.203                       Antenna Requirement                  Compliance
              §15.207                   AC Line Conducted Emission               Compliance
              §15.225
                                           Radiated Emission Test                Compliance
          §15.209 §15.205
             §15.225(e)                      Frequency Stability                 Compliance
             §15.215(c)                   20 dB Emission Bandwidth               Compliance




                                                                                              Page 7 of 29


 Bay Area Compliance Laboratories Corp. (Dongguan)                     Report No.: RXM190515053-00A

FCC§15.203 - ANTENNA REQUIREMENT
Applicable Standard
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
responsible party shall be used with the device. The use of a permanently attached antenna or of an
antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with
the provisions of this section.


Antenna Connected Construction
The EUT has two integral antenna arrangement, one for 13.56MHz, one for 125kHz, which was
permanently attached and fulfill the requirement of this section. Please refer to the EUT photos.

Result: Compliance.




                                                                                                 Page 8 of 29


 Bay Area Compliance Laboratories Corp. (Dongguan)                    Report No.: RXM190515053-00A

FCC §15.207 – AC LINE CONDUCTED EMISSION

EUT Setup




The setup of EUT is according with per ANSI C63.10-2013 measurement procedure. The specification
used was with the FCC Part 15.207 limits.

The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the
middle.

The spacing between the peripherals was 10 cm.

The adapter was connected to the main LISN with an AC 120V/60Hz power source.


EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

                              Frequency Range                      IF B/W
                              150 kHz – 30 MHz                      9 kHz




                                                                                               Page 9 of 29


 Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RXM190515053-00A

Test Equipment List and Details

                                                                     Serial        Calibration    Calibration
      Manufacturer              Description           Model
                                                                    Number            Date         Due Date
         Unknown               Coaxial Cable       C-NJNJ-50        C-0200-01      2018-09-05      2019-09-05
           R&S                 Test Software         EMC32        Version8.53.0        N/A            N/A
           R&S              Two-line V-network      ENV 216          101614        2018-12-10      2019-12-10
           R&S               EMI Test Receiver        ESPI           100120        2019-05-09      2020-05-09

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).


Test Procedure
During the conducted emission test, the adapter or POE was connected to the outlet of the LISN.
Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All data was recorded in the Quasi-peak and average detection mode.

According FCC publication number 174176,for a device with a permanent antenna operating at or below
30 MHz, the measurements done with a suitable dummy load, in lieu of the permanent antenna under the
following conditions: (1) perform the AC line conducted tests with the permanent antenna to determine
compliance with the Section 15.207 limits outside the transmitter's fundamental emission band; (2) retest
with a dummy load in lieu of the permanent antenna to determine compliance with the Section 15.207
limits within the transmitter's fundamental emission band.


Corrected Amplitude & Margin Calculation
The basic equation is as follows:

VC = VR + AC + VDF

Herein,
VC: corrected voltage amplitude
VR: reading voltage amplitude

Ac: attenuation caused by cable loss

VDF: voltage division factor of AMN or ISN

The “Margin” column of the following data tables indicates the degree of compliance within the
applicable limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation
for margin calculation is as follows:

                                    Margin = Limit – Corrected Amplitude




                                                                                                    Page 10 of 29


 Bay Area Compliance Laboratories Corp. (Dongguan)                  Report No.: RXM190515053-00A

Test Results Summary
According to the recorded data in following table, the EUT complied with the FCC Part 15.207.


Test Data
    Environmental Conditions

             Temperature:             29.1℃
        Relative Humidity:             51%
           ATM Pressure:              99.7kPa
                   Test by:          Lily Xie
                 Test Date:         2019-07-10




                                                                                           Page 11 of 29


 Bay Area Compliance Laboratories Corp. (Dongguan)                                      Report No.: RXM190515053-00A

Test mode: Transmitting

Test Mode: AC/DC Adapter supply
AC 120V, 60 Hz, Line:


                         80

                         70
                                                                                                      Quasi-Peak Limit
                         60
                                                                                                         Average Limit
                         50
          Level in dBμ




                         40

                         30

                         20

                         10

                          0
                          150k       300    400 500     800 1M       2M     3M     4M 5M 6    8 10M         20M     30M
                                                                 Frequency in Hz



                         Frequency         Quasi Peak       Bandwidth                 Corr.    Margin        Limit
                                                                            Line
                           (MHz)            (dBμV)            (kHz)                   (dB)      (dB)        (dBμV)
                          0.150000            45.8            9.000          L1       11.2      19.2          66.0
                          0.316369            43.5            9.000          L1       10.1      16.3          59.8
                          0.622369            33.3            9.000          L1        9.8      22.7          56.0
                          1.075780            32.4            9.000          L1        9.8      23.6          56.0
                          3.119684            26.4            9.000          L1        9.8      29.6          56.0
                         26.961902            22.3            9.000          L1        9.8      35.7          60.0

                         Frequency          Average         Bandwidth                 Corr.    Margin        Limit
                                                                            Line
                           (MHz)            (dBμV)            (kHz)                   (dB)      (dB)        (dBμV)
                          0.150000            33.1            9.000          L1       11.2      22.9          56.0
                          0.313237            37.3            9.000          L1       10.1      12.6          49.9
                          0.434989            28.5            9.000          L1        9.9      18.7          47.2
                          0.774673            28.6            9.000          L1        9.8      17.4          46.0
                          3.119684            18.1            9.000          L1        9.8      27.9          46.0
                         25.063636            18.3            9.000          L1        9.8      31.7          50.0




                                                                                                                     Page 12 of 29


 Bay Area Compliance Laboratories Corp. (Dongguan)                                      Report No.: RXM190515053-00A

AC120 V, 60 Hz, Neutral:


                         80

                         70
                                                                                                      Quasi-Peak Limit
                         60
                                                                                                         Average Limit
                         50
          Level in dBμ




                         40

                         30

                         20

                         10

                          0
                          150k       300    400 500     800 1M       2M     3M     4M 5M 6    8 10M         20M     30M
                                                                 Frequency in Hz



                         Frequency         Quasi Peak       Bandwidth                 Corr.    Margin        Limit
                                                                            Line
                           (MHz)            (dBμV)            (kHz)                   (dB)      (dB)        (dBμV)
                          0.150000            45.8            9.000          N        11.2      20.2          66.0
                          0.316369            46.4            9.000          N        10.1      10.4          59.8
                          0.452652            35.7            9.000          N         9.9      20.1          56.8
                          0.744445            33.2            9.000          N         9.8      22.8          56.0
                          3.621856            22.2            9.000          N         9.8      33.8          56.0
                         24.961021            23.7            9.000          N         9.8      36.3          60.0

                         Frequency          Average         Bandwidth                 Corr.    Margin        Limit
                                                                            Line
                           (MHz)            (dBμV)            (kHz)                   (dB)      (dB)        (dBμV)
                          0.244252            37.8            9.000          N        11.2      14.2          52.0
                          0.313237            39.4            9.000          N        10.1      10.5          49.9
                          0.434989            29.1            9.000          N         9.9      18.1          47.2
                          0.774673            28.6            9.000          N         9.8      17.4          46.0
                          3.621856            15.0            9.000          N         9.8      31.0          46.0
                         24.961921            17.5            9.000          N         9.8      32.5          50.0




                                                                                                                     Page 13 of 29


 Bay Area Compliance Laboratories Corp. (Dongguan)                                       Report No.: RXM190515053-00A

Test Mode: PoE Power supply
AC 120V, 60 Hz, Line:


                         80

                         70
                                                                                                         Quasi-Peak Limit
                         60
                                                                                                            Average Limit
                         50
          Level in dBμ




                         40

                         30

                         20

                         10

                          0
                          150k       300    400 500     800 1M           2M   3M    4M 5M 6    8 10M           20M      30M
                                                                  Frequency in Hz



                         Frequency         Quasi Peak       Bandwidth                  Corr.    Margin          Limit
                                                                              Line
                           (MHz)            (dBμV)            (kHz)                    (dB)      (dB)          (dBμV)
                          0.254170            46.1            9.000           L1       10.3      15.5            61.6
                          0.261872            46.6            9.000           L1       10.3      14.7            61.4
                          0.541438            34.0               9.000        L1        9.9       22.0           56.0
                          0.798146            33.3               9.000        L1        9.8       22.7           56.0
                          3.621856            28.0               9.000        L1        9.8       28.0           56.0
                         11.601974            24.7               9.000        L1        9.8       35.3           60.0

                         Frequency          Average         Bandwidth                  Corr.    Margin          Limit
                                                                              Line
                           (MHz)            (dBμV)            (kHz)                    (dB)      (dB)          (dBμV)
                          0.249162            39.0            9.000           L1       10.3      12.8            51.8
                          0.267135            40.9            9.000           L1       10.3      10.3            51.2
                          0.569057            28.5            9.000           L1        9.8      17.5            46.0
                          0.774673            29.6            9.000           L1        9.8      16.4            46.0
                          3.621856            21.9            9.000           L1        9.8      24.1            46.0
                         11.601974            18.8            9.000           L1        9.8      31.2            50.0




                                                                                                                        Page 14 of 29


 Bay Area Compliance Laboratories Corp. (Dongguan)                                      Report No.: RXM190515053-00A

AC120 V, 60 Hz, Neutral:


                         80

                         70
                                                                                                      Quasi-Peak Limit
                         60
                                                                                                         Average Limit
                         50
          Level in dBμ




                         40

                         30

                         20

                         10

                          0
                          150k       300    400 500     800 1M       2M     3M     4M 5M 6    8 10M         20M     30M
                                                                 Frequency in Hz



                         Frequency         Quasi Peak       Bandwidth                 Corr.    Margin        Limit
                                                                            Line
                           (MHz)            (dBμV)            (kHz)                   (dB)      (dB)        (dBμV)
                          0.150000            41.3            9.000          N        11.2      24.7          66.0
                          0.261872            46.7            9.000          N        10.3      14.7          61.4
                          0.598084            35.8            9.000          N         9.8      20.2          56.0
                          0.798146            35.4            9.000          N         9.8      20.6          56.0
                          3.621856            30.5            9.000          N         9.8      25.5          56.0
                          7.870427            33.3            9.000          N         9.8      26.7          60.0

                         Frequency          Average         Bandwidth                 Corr.    Margin        Limit
                                                                            Line
                           (MHz)            (dBμV)            (kHz)                   (dB)      (dB)        (dBμV)
                          0.150000            34.1            9.000          N        11.2      21.9          56.0
                          0.267135            40.1            9.000          N        10.3      11.1          51.2
                          0.592163            28.5            9.000          N         9.8      17.5          46.0
                          0.838859            28.2            9.000          N         9.8      17.8          46.0
                          3.621856            22.4            9.000          N         9.8      23.6          46.0
                         24.987412            24.5            9.000          N         9.8      25.5          50.0




                                                                                                                     Page 15 of 29


 Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RXM190515053-00A

FCC§15.225, §15.205 & §15.209 - RADIATED EMISSIONS TEST
Applicable Standard
FCC Part 15.205, 15.209, 15.225
(a) The field strength of any emissions within the band 13.553–13.567 MHz shall not exceed 15,848
    microvolts/meter at 30 meters.
(b) Within the bands 13.410–13.553 MHz and 13.567–13.710 MHz, the field strength of any emissions
    shall not exceed 334 microvolts/meter at 30 meters.
(c) Within the bands 13.110–13.410 MHz and 13.710–14.010 MHz the field strength of any emissions
    shall not exceed 106 microvolts/meter at 30 meters.

(d) The field strength of any emissions appearing outside of the 13.110–14.010 MHz band shall not exceed
    the general radiated emission limits in §15.209.
As per FCC Part 15.209

 (a) Except as provided elsewhere in this subpart, the emissions from an intentional radiator shall not
exceed the field strength levels specified in the following table:

  Frequency (MHz)            Field strength (microvolts/meter)         Measurement distance (meters)
0.009-0.490             2400/F(kHz)                                                                       300
0.490-1.705             24000/F(kHz)                                                                       30
1.705-30.0              30                                                                                 30
30-88                   100**                                                                              3
88-216                  150**                                                                              3
216-960                 200**                                                                              3
Above 960               500                                                                                3
      **Except as provided in paragraph (g), fundamental emissions from intentional radiators operating
under this section shall not be located in the frequency bands 54-72 MHz, 76-88 MHz, 174-216 MHz or
470-806 MHz. However, operation within these frequency bands is permItted under other sections of this
part, e.g., §§15.231 and 15.241.




                                                                                                Page 16 of 29


 Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RXM190515053-00A


EUT Setup




The radiated emission tests were performed in the 10-meter chamber test site, using the setup accordance
with the ANSI C63.10-2013. The specification used was the FCC Part Subpart C limits.

The spacing between the peripherals was 10 cm.


EMI Test Receiver Setup
The system was investigated from 9 kHz to 1 GHz.

During the radiated emission test, the EMI test Receiver was set with the following configurations:

                      Frequency Range            RBW          Video B/W     Measurement
                      9 kHz – 150 kHz            200 Hz         1 kHz        QP/Average
                     150 kHz – 30 MHz            9 kHz         30 kHz        QP/Average
                    30 MHz – 1000 MHz           120 kHz        300 kHz           QP

The emission limits shown in the above table are based on measurements employing a CISPR quasi-peak
detector except for the frequency bands 9-90 kHz, 110-490 kHz and above 1000 MHz. Radiated emission
limits in these three bands are based on measurements employing an average detector.

If the maximized peak measured value complies with the limit, then it is unnecessary to perform an
QP/Average measurement




                                                                                              Page 17 of 29


 Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RXM190515053-00A

Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Amplitude reading. The basic equation is as follows:

                 Corr. Ampl. = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

                                          Margin = Limit - Corr. Ampl.


Test Equipment List and Details

                                                                     Serial       Calibration    Calibration
    Manufacturer           Description             Model
                                                                    Number           Date         Due Date
         R&S            EMI Test Receiver          ESR3             102453         2019-06-26    2020-06-26
        Farad             Test Software           EZ-EMC            V1.1.4.2          N/A            N/A
        EMCO              Passive Loop              6512           9706-1206       2017-03-05    2020-03-04
      Unknown             Coaxial Cable          C-NJNJ-50         C-0400-01       2018-09-05    2019-09-05
      Unknown             Coaxial Cable          C-NJNJ-50         C-0075-01       2018-09-05    2019-09-05
      Unknown             Coaxial Cable          C-NJNJ-50         C-1400-01       2019-05-06    2020-05-06
    Sunol Sciences           Antenna                JB3           A060611-1        2017-11-10    2020-11-10
         HP                 Amplifier              8447D          2727A05902       2018-09-05    2019-09-05

   * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
    have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Results Summary
According to the data in the following table, the EUT complied with the FCC Part 15.209&15.225.




                                                                                                   Page 18 of 29


 Bay Area Compliance Laboratories Corp. (Dongguan)            Report No.: RXM190515053-00A

Test Data
    Environmental Conditions

              Temperature:         24.2 C
         Relative Humidity:          53 %
            ATM Pressure:         100.3 kPa
                    Tester:       Tyler Pan
                 Test Date:       2019-06-28

Test mode: Transmitting(AC/DC Adapter supply was the worst)




                                                                                   Page 19 of 29


 Bay Area Compliance Laboratories Corp. (Dongguan)                Report No.: RXM190515053-00A


1) 9 kHz~150 kHz:




                                                                                                 125kHz
                                                                                                 Fundamental




                       Receiver                 Correction     Cord.
        Frequency                                                         Limit     Margin
                       Reading      Detector     Factor        Amp.
          (MHz)                                                         (dBμV/m)     (dB)
                       (dBμV)                    (dB/m)      (dBμV/m)
          0.0091        -25.81        peak        88.67        62.86     128.42      65.56
          0.0117        -24.45        peak           87.26    62.81      126.24      63.43
          0.0140        -22.68        peak           85.35    62.67      124.68      62.01
          0.0190        -20.36        peak           81.21    60.85      122.03      61.18
          0.0240        -19.36        peak           79.02    59.66      120.00      60.34
          0.1255         13.35        peak           65.36    78.71      105.63      26.92




                                                                                       Page 20 of 29


 Bay Area Compliance Laboratories Corp. (Dongguan)                Report No.: RXM190515053-00A

150 kHz~30 MHz:




                                                                                             13.56MHz
                                                                                             Fundamental




                       Receiver                 Correction     Cord.
        Frequency                                                         Limit     Margin
                       Reading      Detector     Factor        Amp.
          (MHz)                                                         (dBμV/m)     (dB)
                       (dBμV)                    (dB/m)      (dBμV/m)
          0.2692        28.98         peak        32.40        61.38      99.00      37.62
          0.8662        37.26         peak        22.85        60.11      68.85       8.74
          2.9260        47.37         peak        13.33        60.70      69.54       8.84
          3.0455        45.93         peak        13.05        58.98      69.54      10.56
          7.4931        27.07         peak         9.59        36.66      69.54      32.88




                                                                                       Page 21 of 29


 Bay Area Compliance Laboratories Corp. (Dongguan)                Report No.: RXM190515053-00A

Fundamental:




                       Receiver                 Correction     Cord.
        Frequency                                                         Limit     Margin
                       Reading      Detector     Factor        Amp.
          (MHz)                                                         (dBμV/m)     (dB)
                       (dBμV)                    (dB/m)      (dBμV/m)
         13.5610        56.27         peak         9.36        65.63     124.00      58.37




                                                                                       Page 22 of 29


 Bay Area Compliance Laboratories Corp. (Dongguan)                Report No.: RXM190515053-00A

2) Above 30 MHz

Horizontal




                       Receiver                 Correction     Cord.
        Frequency                                                         Limit     Margin
                       Reading      Detector     Factor        Amp.
          (MHz)                                                         (dBμV/m)     (dB)
                       (dBμV)                    (dB/m)      (dBμV/m)
         31.9400        27.03         peak         0.19        27.22      40.00      12.78
         299.6600       28.50         peak        -3.83        24.67      46.00      21.33
         551.8600        32.88        peak           0.35     33.23       46.00      12.77
         743.9200        32.33        peak           3.56     35.89       46.00      10.11
         792.4200        29.99        peak           4.34     34.33       46.00      11.67
         956.3500        32.12        peak           0.89     33.01       46.00      12.99




                                                                                       Page 23 of 29


 Bay Area Compliance Laboratories Corp. (Dongguan)                Report No.: RXM190515053-00A

Vertical




                       Receiver                 Correction     Cord.
        Frequency                                                         Limit     Margin
                       Reading      Detector     Factor        Amp.
          (MHz)                                                         (dBμV/m)     (dB)
                       (dBμV)                    (dB/m)      (dBμV/m)
           30.0000      25.28         peak         1.72        27.00      40.00      13.00
           189.0800     32.00         peak        -7.17        24.83      43.50      18.67
           551.8600      35.16        peak           0.35     35.51       46.00      10.49
           647.8900      32.48        peak           2.15     34.63       46.00      11.37
           696.3900      32.74        peak           2.89     35.63       46.00      10.37
           743.9200      32.43        peak           3.56     35.99       46.00      10.01




                                                                                       Page 24 of 29


 Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RXM190515053-00A

FCC§15.225(e) - FREQUENCY STABILITY
Applicable Standard
The frequency tolerance of the carrier signal shall be maintained within ±0.01% of the operating frequency
over a temperature variation of −20 degrees to +50 degrees C at normal supply voltage, and for a variation
in the primary supply voltage from 85% to 115% of the rated supply voltage at a temperature of 20 degrees
C. For battery operated equipment, the equipment tests shall be performed using a new battery.


Test Procedure
Frequency Stability vs. Temperature: The adapter under test was connected to an external power.

The EUT was placed inside the temperature chamber.
After the temperature stabilized for approximately 20 minutes, the frequency output was recorded from the
Spectrum Analyzer.

Frequency Stability vs. Voltage: An external variable power supply Source connected to the EUT or EUT
adapter. Test the frequency output in the extremity voltage.


Test Equipment List and Details

                                                                      Serial        Calibration   Calibration
     Manufacturer           Description             Model
                                                                     Number            Date        Due Date
         R&S             EMI Test Receiver           ESR3            102453         2019-06-26     2020-06-26
        EMCO                Passive Loop             6512           9706-1206       2017-03-05     2020-03-04
       Unknown             Coaxial Cable           C-NJNJ-50        C-0400-01       2018-09-05     2019-09-05
          HP                    Amplifier           8447D          2727A05902       2018-09-05     2019-09-05
         UNI-T              Multimeter              UT39A          M130199938       2018-07-24     2019-07-24
                        Constant temperature
        ESPEC                                      ESX-4CA           018 463        2019-03-26     2020-03-26
                        and humidity Tester
       Schneider         AC Power Supply            YF6005             005              N/A           N/A
     Pro instrument      DC Power Supply            pps3300            N/A              N/A           N/A

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions
               Temperature:             24.2 C
          Relative Humidity:                53 %
             ATM Pressure:             100.3 kPa
                      Tester:          Tyler Pan
                   Test Date:         2019-06-28


                                                                                                    Page 25 of 29


 Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RXM190515053-00A

   Test Mode: Transmitting

   Test Result: Pass

POE adapter:
                                                 fo = 13.56 MHz
                                                  Measured
                 Temperature       Voltage                        Frequency Error    Limit
                                                  frequency
                     ℃               VAC            MHz                 Hz            Hz
                     -20                          13.560614            614           ±1356
                     -10                          13.560613            613           ±1356
                       0                          13.560607            607           ±1356
                     10                           13.560615            615           ±1356
                     20             120V          13.560609            609           ±1356
                     25                           13.560608            608           ±1356
                     30                           13.560615            615           ±1356
                     40                           13.560611            611           ±1356
                     50                           13.560619            619           ±1356
                     25              102          13.560627            627           ±1356
                     25              138          13.560614            614           ±1356

DC Port input:
                                                 fo = 13.56 MHz
                                                  Measured
                 Temperature       Voltage                        Frequency Error    Limit
                                                  frequency
                     ℃               VDC            MHz                 Hz            Hz
                     -20                           13.56008             80           ±1356
                     -10                           13.56007             70           ±1356
                       0                           13.56011            110           ±1356
                     10                            13.56012            120           ±1356
                     20              12V           13.56013            130           ±1356
                     25                            13.56007             70           ±1356
                     30                            13.56006             60           ±1356
                     40                            13.56008             80           ±1356
                     50                            13.56009             90           ±1356
                     25              9.0           13.56012            120           ±1356
                     25              15.0          13.56012            120           ±1356
Note: Operation voltage range declared by manufacturer.




                                                                                             Page 26 of 29


 Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RXM190515053-00A

FCC §15.215(c) – 20 dB EMISSION BANDWIDTH
Applicable Standard

Per FCC §15.215 (c) Intentional radiators operating under the alternative provisions to the general
emission limits, as contained in §15.217 through § 15.257 and in Subpart E of this part, must be designed
to ensure that the 20 dB bandwidth of the emission, or whatever bandwidth may otherwise be specified in
the specific rule section under which the equipment operates, is contained within the frequency band
designated in the rule section under which the equipment is operated. The requirement to contain the
designated bandwidth of the emission within the specified frequency band includes the effects from
frequency sweeping, frequency hopping and other modulation techniques that may be employed as well as
the frequency stability of the transmitter over expected variations in temperature and supply voltage. If a
frequency stability is not specified in the regulations, it is recommended that the fundamental emission be
kept within at least the central 80% of the permitted band in order to minimize the possibility of out-of -
band operation.

Test Procedure
Measure the frequency difference of two frequencies that were attenuated 20 dB from the reference level.
Record the frequency difference as the emission bandwidth.

Test Equipment List and Details

                                                                      Serial        Calibration   Calibration
     Manufacturer           Description             Model
                                                                     Number            Date        Due Date
         R&S             EMI Test Receiver          ESR3             102453         2019-06-26     2020-06-26
        EMCO                Passive Loop             6512           9706-1206       2017-03-05     2020-03-04
       Unknown             Coaxial Cable          C-NJNJ-50         C-0400-01       2018-09-05     2019-09-05
          HP                  Amplifier             8447D          2727A05902       2018-09-05     2019-09-05

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).

Test Data
     Environmental Conditions

                    Temperature:         24.0 C~24.2 C
               Relative Humidity:           50 %~53 %
                  ATM Pressure:        100.1 kPa~100.3 kPa
                           Tester:           Tyler Pan
                        Test Date:    2019-06-27~2019-08-09

      Test Result: Compliance.

       Please refer to following tables and plots



                                                                                                    Page 27 of 29


 Bay Area Compliance Laboratories Corp. (Dongguan)         Report No.: RXM190515053-00A

                          Test Frequency               20 dB Bandwidth
                              (MHz)                         (kHz)
                               13.56                        0.753
                              0.125                         0.832

Test Mode: Transmitting
                              20 dB Emission Bandwidth-13.56 MHz




                                                                                Page 28 of 29


Bay Area Compliance Laboratories Corp. (Dongguan)                 Report No.: RXM190515053-00A

                                      20 dB Emission Bandwidth-125 kHz




        Date: 9.AUG.2019   10:03:06



                                       ***** END OF REPORT *****




                                                                                       Page 29 of 29