Test Report

FCC ID: 2AHCR-R20X

Test Report

Download: PDF
FCCID_3860577

                                             FCC PART 15C

                                             TEST REPORT
                                                              For


        AKUVOX (XIAMEN) NETWORKS CO., LTD.
                                  10/F, No.56, Software Park II , Xiamen, China


                                          FCC ID: 2AHCR-R20X



            Report Type:                                 Product Name:
            Original Report                              Door Phone



                  Report Number:           RXM180205050-00B


                      Report Date:         2018-04-16
                                           Jerry Zhang

                     Reviewed By:          EMC Manager

                                           Bay Area Compliance Laboratories Corp. (Dongguan)
                 Test Laboratory:          No.69 Pulongcun, Puxinhu Industry Area,
                                           Tangxia, Dongguan, Guangdong, China
                                           Tel: +86-769-86858888
                                           Fax: +86-769-86858891
                                           www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
       used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). This report must
       not be used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the
       Federal Government. * This report may contain data that are not covered by the A2LA accreditation and are marked with
       an asterisk “*”.


  Bay Area Compliance Laboratories Corp. (Dongguan)                                                                       Report No.: RXM180205050-00B




                                                       TABLE OF CONTENTS

GENERAL INFORMATION .......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 MEASUREMENT UNCERTAINTY ....................................................................................................................................4
 TEST FACILITY .............................................................................................................................................................4
SUMMARY OF TEST RESULTS ...............................................................................................................................5
SYSTEM TEST CONFIGURATION ..........................................................................................................................6
  JUSTIFICATION .............................................................................................................................................................6
  EUT EXERCISE SOFTWARE ..........................................................................................................................................6
  SUPPORT CABLE LIST AND DETAILS ............................................................................................................................6
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................7
FCC§15.203 - ANTENNA REQUIREMENT..............................................................................................................8
  APPLICABLE STANDARD ..............................................................................................................................................8
  ANTENNA CONNECTED CONSTRUCTION ......................................................................................................................8
FCC §15.207 – AC LINE CONDUCTED EMISSION ...............................................................................................9
  EUT SETUP ..................................................................................................................................................................9
  EMI TEST RECEIVER SETUP .........................................................................................................................................9
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................10
  TEST PROCEDURE ......................................................................................................................................................10
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................10
  TEST RESULTS SUMMARY ..........................................................................................................................................11
  TEST DATA ................................................................................................................................................................11
FCC§15.225, §15.205 & §15.209 - RADIATED EMISSIONS TEST ......................................................................16
  APPLICABLE STANDARD ............................................................................................................................................16
  EUT SETUP ................................................................................................................................................................17
  EMI TEST RECEIVER SETUP .......................................................................................................................................17
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................17
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................18
  TEST RESULTS SUMMARY ..........................................................................................................................................18
  TEST DATA ................................................................................................................................................................18
FCC§15.225(E) - FREQUENCY STABILITY..........................................................................................................23
  APPLICABLE STANDARD ............................................................................................................................................23
  TEST PROCEDURE ......................................................................................................................................................23
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................23
  TEST DATA ................................................................................................................................................................24
FCC §15.215(C) – 20 DB EMISSION BANDWIDTH ..............................................................................................25
  APPLICABLE STANDARD ............................................................................................................................................25
  TEST PROCEDURE ......................................................................................................................................................25
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................25
  TEST DATA ................................................................................................................................................................26




                                                                                                                                                            Page 2 of 26


 Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RXM180205050-00B

GENERAL INFORMATION

Product Description for Equipment Under Test (EUT)

                         EUT Name:      Door Phone
                         EUT Model:     R20A
                             FCC ID:    2AHCR-R20X
                 Rated Input Voltage:   DC12V from DC pin or PoE port
                 External Dimension:    145mm(L)*90mm(W)*38mm(H)
                      Serial Number:    180205050
                 EUT Received Date:     2018.02.05


Objective
This Type approval report is prepared on behalf of AKUVOX (XIAMEN) NETWORKS CO., LTD.
in accordance with Part 2, Subpart J, and Part 15, Subparts A and C of the Federal Communications
Commission’s rules.

The objective is to determine the compliance of the EUT with FCC rules, sec 15.203, 15.205, 15.207,
15.209 and 15.225.


Related Submittal(s)/Grant(s)
N/A


Test Methodology
All measurements detailed in this Test Report were performed in accordance with ANSI C63.10-2013
“American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices”.

All emissions measurement was performed and Bay Area Compliance Laboratories Corp. (Dongguan).
The radiated testing was performed at an antenna-to-EUT distance of 3 meters.




                                                                                             Page 3 of 26


 Bay Area Compliance Laboratories Corp. (Dongguan)                        Report No.: RXM180205050-00B

Measurement Uncertainty
               Parameter                                Measurement Uncertainty
       Occupied Channel Bandwidth                                  ±5 %
                                                          9kHz~30MHz: 4.12dB
            radiated Emissions             30M~200MHz: 4.58 dB for Horizontal, 4.59 dB for Vertical
                                            200M~1GHz: 4.83 dB for Horizontal, 5.85 dB for Vertical
              Temperature                                          ±1℃
                Humidity                                           ±5%
      DC and low frequency voltages                               ±0.4%
               Duty Cycle                                           1%
       AC Power Lines Conducted                          3.12 dB (150 kHz to 30 MHz)
                Emission



Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located
on the No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China.

The test site has been approved by the FCC under the KDB 974614 D01 and is listed in the FCC Public
Access Link (PAL) database, FCC Registration No. : 897218,the FCC Designation No. : CN1220.

The test site has been registered with ISED Canada under ISED Canada Registration Number 3062D.




                                                                                               Page 4 of 26


Bay Area Compliance Laboratories Corp. (Dongguan)                    Report No.: RXM180205050-00B

SUMMARY OF TEST RESULTS

             FCC Rules                       Description of Test               Result

              §15.203                       Antenna Requirement              Compliance
              §15.207                   AC Line Conducted Emission           Compliance
              §15.225
                                           Radiated Emission Test            Compliance
          §15.209 §15.205
             §15.225(e)                      Frequency Stability             Compliance
             §15.215(c)                   20 dB Emission Bandwidth           Compliance




                                                                                          Page 5 of 26


 Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RXM180205050-00B

SYSTEM TEST CONFIGURATION
Justification
The system was configured for testing in a test mode.

The device operates simultaneously in 125 kHz and 13.56 MHz for RFID detection.


EUT Exercise Software
No software used in test.


Support Equipment List and Details

      Manufacturer               Description                  Model                   Serial Number
         L.T.E.                  DC Adapter               G0548B-480-050                   N/A
         Fujia                   PoE Adapter              FJ-SW1201000C                    N/A
          RSD                   Button Switch                 KCD1                         N/A
       Schneider                    Relay                  RXM2LB2BD                       N/A
       TP-LINK                     Switch                   TL-SF1008P                114A297001782
         Tenda                  Wireless router                D301                        N/A


Support Cable List and Details

                                                            Length
  Cable Description     Shielding Type     Ferrite Core                    From Port             To
                                                             (m)
                                                                                              Wireless
      RJ45 Cable              No                  No          5       RJ45 Port of EUT
                                                                                               router
     RS485 Cable              No                  No          5      RS485 Port of EUT        Switch
     Signal Cable             No                  No          5      DOOR Port of EUT       Button Switch
     Signal Cable             No                  No          5       Relay Port of EUT         Relay
      RJ45 Cable              No                  No          1       RJ45 Port of EUT          PoE
                                                                                              Wireless
      RJ45 Cable              No                  No          5       RJ45 Port of PoE
                                                                                               router
      DC Cable                No                  No          1.2           Adapter             EUT




                                                                                               Page 6 of 26


 Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RXM180205050-00B


Block Diagram of Test Setup

Adapter supply




PoE supply




                                                                       Page 7 of 26


 Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RXM180205050-00B

FCC§15.203 - ANTENNA REQUIREMENT
Applicable Standard
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
responsible party shall be used with the device. The use of a permanently attached antenna or of an
antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with
the provisions of this section.


Antenna Connected Construction
The EUT has two integral antenna arrangement, one for 13.56MHz, one for 125kHz, which was
permanently attached and fulfill the requirement of this section. Please refer to the EUT photos.

Result: Compliance.




                                                                                                 Page 8 of 26


 Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RXM180205050-00B

FCC §15.207 – AC LINE CONDUCTED EMISSION

EUT Setup




The setup of EUT is according with per ANSI C63.10-2013 measurement procedure. The specification
used was with the FCC Part 15.207 limits.

The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the
middle.

The spacing between the peripherals was 10 cm.

The adapter was connected to the main lisn with an AC 120V/60Hz power source.


EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

                              Frequency Range                      IF B/W
                              150 kHz – 30 MHz                      9 kHz




                                                                                               Page 9 of 26


 Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RXM180205050-00B

Test Equipment List and Details

                                                                      Serial        Calibration     Calibration
    Manufacturer               Description            Model
                                                                     Number            Date          Due Date

         R&S                EMI Test Receiver        ESCS 30        830245/006      2017-12-11      2018-12-11
         R&S                     L.I.S.N             ESH2-Z5        892107/021      2017-09-01      2018-09-01
          N/A                 Coaxial Cable         C-NJNJ-50       C-0200-01       2017-09-05      2018-09-05
         R&S                  Test Software          EMC32         Version8.53.0        N/A             N/A

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).


Test Procedure
During the conducted emission test, the adapter was connected to the outlet of the LISN.

Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All data was recorded in the Quasi-peak and average detection mode.

According FCC publication number 174176,for a device with a permanent antenna operating at or below
30 MHz, the measurements done with a suitable dummy load, in lieu of the permanent antenna under the
following conditions: (1) perform the AC line conducted tests with the permanent antenna to determine
compliance with the Section 15.207 limits outside the transmitter's fundamental emission band; (2) retest
with a dummy load in lieu of the permanent antenna to determine compliance with the Section 15.207
limits within the transmitter's fundamental emission band.


Corrected Amplitude & Margin Calculation
The basic equation is as follows:

VC = VR + AC + VDF

Herein,
VC: corrected voltage amplitude
VR: reading voltage amplitude

Ac: attenuation caused by cable loss

VDF: voltage division factor of AMN or ISN




                                                                                                    Page 10 of 26


 Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RXM180205050-00B

The “Margin” column of the following data tables indicates the degree of compliance within the
applicable limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation
for margin calculation is as follows:


                                  Margin = Limit – Corrected Amplitude

Test Results Summary
According to the recorded data in following table, the EUT complied with the FCC Part 15.207.


Test Data
    Environmental Conditions

            Temperature:             23.7 C
       Relative Humidity:             57 %
          ATM Pressure:             101.4kPa

    The testing was performed by Alex You on 2018-03-01




                                                                                            Page 11 of 26


 Bay Area Compliance Laboratories Corp. (Dongguan)                                         Report No.: RXM180205050-00B


Test Mode: Transmitting(AC/DC adapter)
AC 120V, 60 Hz, Line:



                         80

                         70
                                                                                                   Quasi-Peak Limit
                         60

                                                                                                      Average Limit
                         50
          Level in dBμ




                         40

                         30

                         20

                         10

                         0
                         150k      300   400 500     800 1M        2M     3M     4M 5M 6   8 10M         20M     30M
                                                               Frequency in Hz



     Frequency                  Quasi Peak         Bandwidth               Corr.      Margin    Limit
                                                                  Line                                         Comment
       (MHz)                     (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.193566                     48.5              9.000         L1      10.7        15.4      63.9          Compliance
      0.270502                     38.0              9.000         L1      10.3        23.1      61.1          Compliance
      0.429420                     42.5              9.000         L1       9.9        14.8      57.3          Compliance
      0.432855                     42.1              9.000         L1       9.9        15.1      57.2          Compliance
      0.665597                     35.2              9.000         L1       9.8        20.8      56.0          Compliance
      1.500325                     34.5              9.000         L1       9.7        21.5      56.0          Compliance

     Frequency                   Average           Bandwidth               Corr.      Margin    Limit
                                                                  Line                                         Comment
       (MHz)                     (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.195114                     43.3              9.000         L1      10.7        10.5      53.8          Compliance
      0.281497                     33.4              9.000         L1      10.2        17.4      50.8          Compliance
      0.429420                     39.3              9.000         L1       9.9         8.0      47.3          Compliance
      0.432855                     39.6              9.000         L1       9.9         7.6      47.2          Compliance
      1.561306                     28.3              9.000         L1       9.7        17.7      46.0          Compliance
      1.982914                     28.4              9.000         L1       9.7        17.6      46.0          Compliance




                                                                                                                  Page 12 of 26


 Bay Area Compliance Laboratories Corp. (Dongguan)                                         Report No.: RXM180205050-00B

AC120 V, 60 Hz, Neutral:



                         80

                         70
                                                                                                   Quasi-Peak Limit
                         60

                                                                                                      Average Limit
                         50
          Level in dBμ




                         40

                         30

                         20

                         10

                         0
                         150k      300   400 500     800 1M        2M     3M     4M 5M 6   8 10M         20M     30M
                                                               Frequency in Hz



     Frequency                  Quasi Peak         Bandwidth               Corr.      Margin    Limit
                                                                  Line                                         Comment
       (MHz)                     (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.192030                     49.0              9.000         N       10.7        14.9      63.9          Compliance
      0.288307                     41.2              9.000         N       10.2        19.4      60.6          Compliance
      0.426011                     41.9              9.000         N        9.9        15.4      57.3          Compliance
      0.436318                     40.9              9.000         N        9.9        16.2      57.1          Compliance
      0.687153                     35.5              9.000         N        9.8        20.5      56.0          Compliance
      1.099574                     34.8              9.000         N        9.8        21.2      56.0          Compliance

     Frequency                   Average           Bandwidth               Corr.      Margin    Limit
                                                                  Line                                         Comment
       (MHz)                     (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.192030                     43.8              9.000         N       10.7        10.1      53.9          Compliance
      0.288307                     36.3              9.000         N       10.2        14.3      50.6          Compliance
      0.426011                     38.1              9.000         N        9.9         9.2      47.3          Compliance
      0.432855                     36.4              9.000         N        9.9        10.8      47.2          Compliance
      0.454052                     33.1              9.000         N        9.9        13.7      46.8          Compliance
      0.476287                     31.3              9.000         N        9.9        15.1      46.4          Compliance




                                                                                                                  Page 13 of 26


 Bay Area Compliance Laboratories Corp. (Dongguan)                                          Report No.: RXM180205050-00B

Test Mode: Transmitting(POE adapter)
AC 120V, 60 Hz, Line:



                         80

                         70
                                                                                                     Quasi-Peak Limit
                         60

                                                                                                        Average Limit
                         50
          Level in dBμ




                         40

                         30

                         20

                         10

                         0
                         150k      300    400 500     800 1M        2M     3M     4M 5M 6   8 10M          20M     30M
                                                                Frequency in Hz



     Frequency                  Quasi Peak          Bandwidth               Corr.      Margin    Limit
                                                                   Line                                          Comment
       (MHz)                     (dBμV)               (kHz)                 (dB)        (dB)    (dBμV)
      0.152410                     57.3               9.000         L1      11.2         8.6      65.9           Compliance
      0.181612                     52.9               9.000         L1      10.8        11.5      64.4           Compliance
      0.193566                     45.0               9.000         L1      10.7        18.9      63.9           Compliance
      0.426011                     43.5               9.000         L1       9.9        13.8      57.3           Compliance
      0.499611                     43.7               9.000         L1       9.9        12.3      56.0           Compliance
     26.212978                     44.2               9.000         L1      10.1        15.8      60.0           Compliance

     Frequency                   Average            Bandwidth               Corr.      Margin    Limit
                                                                   Line                                          Comment
       (MHz)                     (dBμV)               (kHz)                 (dB)        (dB)    (dBμV)
      0.183065                     43.7               9.000         L1      10.8        10.6      54.3           Compliance
      0.426011                     36.1               9.000         L1       9.9        11.2        47.3         Compliance
      0.483938                     36.2               9.000         L1       9.9        10.1        46.3         Compliance
      3.463707                     34.7               9.000         L1       9.8        11.3        46.0         Compliance
     24.989247                     38.4               9.000         L1      10.1        11.6        50.0         Compliance
     26.212978                     39.4               9.000         L1      10.1        10.6        50.0         Compliance




                                                                                                                    Page 14 of 26


 Bay Area Compliance Laboratories Corp. (Dongguan)                                         Report No.: RXM180205050-00B

AC120 V, 60 Hz, Neutral:



                         80

                         70
                                                                                                   Quasi-Peak Limit
                         60

                                                                                                      Average Limit
                         50
          Level in dBμ




                         40

                         30

                         20

                         10

                         0
                         150k      300   400 500     800 1M        2M     3M     4M 5M 6   8 10M         20M     30M
                                                               Frequency in Hz



     Frequency                  Quasi Peak         Bandwidth               Corr.      Margin    Limit
                                                                  Line                                         Comment
       (MHz)                     (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.152410                     56.4              9.000         N       11.1         9.5      65.9          Compliance
      0.174519                     52.6              9.000         N       10.9        12.1      64.7          Compliance
      0.203045                     45.0              9.000         N       10.6        18.5      63.5          Compliance
      0.426011                     43.2              9.000         N        9.9        14.1      57.3          Compliance
      0.495646                     43.6              9.000         N        9.9        12.5      56.1          Compliance
     24.989247                     43.5              9.000         N       10.1        16.5      60.0          Compliance

     Frequency                   Average           Bandwidth               Corr.      Margin    Limit
                                                                  Line                                         Comment
       (MHz)                     (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.183065                     39.8              9.000         N       10.8        14.5      54.3          Compliance
      0.422630                     36.3              9.000         N        9.9        11.1      47.4          Compliance
      0.465037                     36.2              9.000         N        9.9        10.4      46.6          Compliance
     24.989247                     39.3              9.000         N       10.1        10.7      50.0          Compliance
     26.212978                     38.6              9.000         N       10.1        11.4      50.0          Compliance
     27.938341                     38.1              9.000         N       10.2        11.9      50.0          Compliance




                                                                                                                  Page 15 of 26


 Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RXM180205050-00B

FCC§15.225, §15.205 & §15.209 - RADIATED EMISSIONS TEST
Applicable Standard
As per FCC Part 15.225
(a) The field strength of any emissions within the band 13.553–13.567 MHz shall not exceed 15,848
    microvolts/meter at 30 meters.
(b) Within the bands 13.410–13.553 MHz and 13.567–13.710 MHz, the field strength of any emissions
    shall not exceed 334 microvolts/meter at 30 meters.
(c) Within the bands 13.110–13.410 MHz and 13.710–14.010 MHz the field strength of any emissions
    shall not exceed 106 microvolts/meter at 30 meters.

(d) The field strength of any emissions appearing outside of the 13.110–14.010 MHz band shall not exceed
    the general radiated emission limits in §15.209.
As per FCC Part 15.209

 (a) Except as provided elsewhere in this subpart, the emissions from an intentional radiator shall not
exceed the field strength levels specified in the following table:

  Frequency (MHz)            Field strength (microvolts/meter)         Measurement distance (meters)
0.009-0.490             2400/F(kHz)                                                                       300
0.490-1.705             24000/F(kHz)                                                                       30
1.705-30.0              30                                                                                 30
30-88                   100**                                                                              3
88-216                  150**                                                                              3
216-960                 200**                                                                              3
Above 960               500                                                                                3
      **Except as provided in paragraph (g), fundamental emissions from intentional radiators operating
under this section shall not be located in the frequency bands 54-72 MHz, 76-88 MHz, 174-216 MHz or
470-806 MHz. However, operation within these frequency bands is permItted under other sections of this
part, e.g., §§15.231 and 15.241.




                                                                                                Page 16 of 26


 Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RXM180205050-00B

EUT Setup




The radiated emission tests were performed in the 3-meter chamber test site, using the setup accordance
with the ANSI C63.10-2013. The specification used was the FCC Part Subpart C limits.

The spacing between the peripherals was 10 cm.


EMI Test Receiver Setup
The system was investigated from 9 kHz to 1 GHz.

During the radiated emission test, the EMI test Receiver was set with the following configurations:

                      Frequency Range             RBW           Video B/W      Detector
                       9 kHz – 150 kHz            200 Hz          1 kHz           QP
                      150 kHz – 30 MHz            9 kHz           30 kHz          QP
                     30 MHz – 1000 MHz           120 kHz         300 kHz          QP

If the maximized peak measured value complies with the limit, then it is unnecessary to perform an
QP/Average measurement


Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Amplitude reading. The basic equation is as follows:

                 Corr. Ampl. = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

                                         Margin = Limit - Corr. Ampl.



                                                                                              Page 17 of 26


 Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RXM180205050-00B

Test Equipment List and Details

                                                                      Serial        Calibration   Calibration
     Manufacturer           Description              Model
                                                                     Number            Date        Due Date
         R&S             EMI Test Receiver            ESCI           100224         2017-12-11     2018-12-11
     Sunol Sciences           Antenna                 JB3           A060611-1       2017-11-10     2020-11-10
          HP                  Amplifier              8447D         2727A05902       2017-09-05     2018-09-05
        EMCO                Passive Loop              6512          9706-1206       2017-03-05     2020-03-04
          N/A               Coaxial Cable           C-NJNJ-50       C-0400-01       2017-09-05     2018-09-05
          N/A               Coaxial Cable           C-NJNJ-50       C-0075-01       2017-09-05     2018-09-05
          N/A               Coaxial Cable           C-NJNJ-50       C-1000-01       2017-09-05     2018-09-05
         Farad              Test Software           EZ-EMC           V1.1.4.2           N/A           N/A

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).

Test Results Summary
According to the data in the following table, the EUT complied with the FCC Part 15.209&15.225.


Test Data
     Environmental Conditions

             Temperature:                 26.1 oC
       Relative Humidity:                  46 %
           ATM Pressure:                101.4 kPa

     * The testing was performed by Eric Xiao on 2018-04-15.

Test mode: Transmitting(AC/DC adapter was the worst)




                                                                                                    Page 18 of 26


 Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RXM180205050-00B

1) 9 kHz~30 MHz:




                       Receiver                 Correction     Cord.
        Frequency                                                           Limit     Margin
                       Reading      Detector     Factor        Amp.
          (MHz)                                                           (dBμV/m)     (dB)
                       (dBμV)                    (dB/m)      (dBμV/m)
          0.0722        23.11         peak        44.99        68.10       110.43      42.33
          0.0840        22.93         peak        43.57        66.50       109.12      42.62
          0.1250        32.74         peak        40.46        73.20       105.66      32.46




                       Receiver                 Correction     Cord.
        Frequency                                                           Limit     Margin
                       Reading      Detector     Factor        Amp.
          (MHz)                                                           (dBμV/m)     (dB)
                       (dBμV)                    (dB/m)      (dBμV/m)
          0.1500        12.92         peak        38.68        51.60       104.08      52.48
          0.5081        23.58         peak        27.22        50.80       73.48       22.68
          3.0455        37.47         peak        13.23        50.70       69.54       18.84
          4.8066         36.53        peak           10.77    47.30         69.54      22.24

                                                                                         Page 19 of 26


 Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RXM180205050-00B


Fundamental:




 Frequency        Reading        Detector       Corrected      Result         Limit        Margin
   (MHz)          (dBuV)                          dB/m       (dBuV/m)       (dBuV/m)        (dB)
  13.5617          58.08           peak              11.34    69.42           124.00        54.58




                                                                                         Page 20 of 26


 Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RXM180205050-00B

30MHz-1GHz(AC/DC adapter was the worst)

Horizontal




                          Receiver                   Correction     Cord.
             Frequency                                                            Limit     Margin
    No.                   Reading      Detector       Factor        Amp.
               (MHz)                                                            (dBμV/m)     (dB)
                          (dBμV)                      (dB/m)      (dBμV/m)
     1       30.0000       23.26          QP            1.54        24.80         40.00      15.20
     2       124.0900      31.46          QP           -4.76        26.70         43.50      16.80
     3       243.4000       44.22         QP           -6.12       38.10          46.00       7.90
     4       263.7700       44.51         QP           -4.61       39.90          46.00       6.10
     5       288.0200       45.60         QP           -4.10       41.50          46.00       4.50
     6       335.5500       39.78         QP           -3.38       36.40          46.00       9.60




                                                                                            Page 21 of 26


 Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RXM180205050-00B

Vertical




                          Receiver                   Correction     Cord.
           Frequency                                                              Limit     Margin
    No.                   Reading      Detector       Factor        Amp.
             (MHz)                                                              (dBμV/m)     (dB)
                          (dBμV)                      (dB/m)      (dBμV/m)
     1      30.9700        30.49          QP            0.81        31.30         40.00       8.70
     2      48.4300        41.80          QP           -10.80       31.00         40.00       9.00
     3      125.0600        30.07         QP           -4.77       25.30          43.50      18.20
     4      239.5200        37.60         QP           -6.10       31.50          46.00      14.50
     5      288.0200        39.10         QP           -4.10       35.00          46.00      11.00
     6      335.5500        32.58         QP           -3.38       29.20          46.00      16.80




                                                                                            Page 22 of 26


 Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RXM180205050-00B

FCC§15.225(e) - FREQUENCY STABILITY
Applicable Standard
The frequency tolerance of the carrier signal shall be maintained within ±0.01% of the operating frequency
over a temperature variation of −20 degrees to +50 degrees C at normal supply voltage, and for a variation
in the primary supply voltage from 85% to 115% of the rated supply voltage at a temperature of 20 degrees
C. For battery operated equipment, the equipment tests shall be performed using a new battery.


Test Procedure
Frequency Stability vs. Temperature: The equipment under test was connected to an external DC power.

The EUT was placed inside the temperature chamber.
After the temperature stabilized for approximately 20 minutes, the frequency output was recorded from the
Spectrum Analyzer.

Frequency Stability vs. Voltage: An external variable DC power supply Source. The voltage was set to the
end point of the battery. The output frequency was recorded for each voltage.


Test Equipment List and Details

                                                                      Serial        Calibration   Calibration
     Manufacturer           Description             Model
                                                                     Number            Date        Due Date
         R&S             EMI Test Receiver          ESCI             100224         2017-12-11     2018-12-11
          HP                  Amplifier             8447D          2727A05902       2017-09-05     2018-09-05
        EMCO                Passive Loop             6512           9706-1206       2017-03-05     2020-03-04
          N/A              Coaxial Cable          C-NJNJ-50         C-0400-01       2017-09-05     2018-09-05
          N/A             Coaxial Cable           C-NJNJ-50         C-1000-01       2017-09-05     2018-09-05
                         High Temperature
      Dongzhixu                                    DP1000          201105083-4      2017-08-28     2018-08-28
                           Test Chamber
         UNI-T              Multimeter             UT39A           M130199938       2017-05-09     2018-05-09
     Pro instrument      DC Power Supply           pps3300             N/A              N/A           N/A

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).




                                                                                                    Page 23 of 26


 Bay Area Compliance Laboratories Corp. (Dongguan)                                  Report No.: RXM180205050-00B

Test Data
     Environmental Conditions

             Temperature:               23.5 oC
        Relative Humidity:               45 %
           ATM Pressure:               101.4 kPa

     * The testing was performed by Eric Xiao on 2018-03-01.

   Test Mode: Transmitting

    Test Result: Pass

                                                   fo = 13.56 MHz
                                                    Measured
                Temperature         Voltage                         Frequency Error          Limit
                                                    frequency
                     ℃                VDC             MHz                     Hz              Hz
                     -20                             13.5607                  700            ±1356
                     -10                             13.5601                  100            ±1356
                        0                            13.5609                  900            ±1356
                     10                              13.5602                  200            ±1356
                     20              12.0            13.5608                  800            ±1356
                     25                              13.5603                  300            ±1356
                     30                              13.5604                  400            ±1356
                     40                              13.5601                  100            ±1356
                     50                              13.5601                  100            ±1356
                     25              11.0            13.5601                  100            ±1356
                     25              13.0            13.5609                  900            ±1356

Note: the operation power supply voltage range is declared by manufacturer.




                                                                                                     Page 24 of 26


 Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RXM180205050-00B

FCC §15.215(c) – 20 dB EMISSION BANDWIDTH
Applicable Standard

Per FCC §15.215 (c) Intentional radiators operating under the alternative provisions to the general
emission limits, as contained in §15.217 through § 15.257 and in Subpart E of this part, must be designed
to ensure that the 20 dB bandwidth of the emission, or whatever bandwidth may otherwise be specified in
the specific rule section under which the equipment operates, is contained within the frequency band
designated in the rule section under which the equipment is operated. The requirement to contain the
designated bandwidth of the emission within the specified frequency band includes the effects from
frequency sweeping, frequency hopping and other modulation techniques that may be employed as well as
the frequency stability of the transmitter over expected variations in temperature and supply voltage. If a
frequency stability is not specified in the regulations, it is recommended that the fundamental emission be
kept within at least the central 80% of the permitted band in order to minimize the possibility of out-of -
band operation.

Test Procedure
Measure the frequency difference of two frequencies that were attenuated 20 dB from the reference level.
Record the frequency difference as the emission bandwidth.


Test Equipment List and Details

                                                                      Serial        Calibration   Calibration
     Manufacturer           Description             Model
                                                                     Number            Date        Due Date
         R&S             EMI Test Receiver          ESCI             100224         2017-12-11     2018-12-11
          HP                  Amplifier             8447D          2727A05902       2017-09-05     2018-09-05
        EMCO                Passive Loop             6512           9706-1206       2017-03-05     2020-03-04
          N/A              Coaxial Cable          C-NJNJ-50         C-0400-01       2017-09-05     2018-09-05
          N/A              Coaxial Cable          C-NJNJ-50         C-1000-01       2017-09-05     2018-09-05

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).




                                                                                                    Page 25 of 26


 Bay Area Compliance Laboratories Corp. (Dongguan)               Report No.: RXM180205050-00B

Test Data

    Environmental Conditions

            Temperature:              23.5 oC
       Relative Humidity:              45 %
          ATM Pressure:             101.4 kPa

    * The testing was performed by Eric Xiao on 2018-03-01.

Test Mode: Transmitting

                                      20 dB Emission Bandwidth




                                   ***** END OF REPORT *****




                                                                                  Page 26 of 26



Document Created: 2018-05-22 19:45:53
Document Modified: 2018-05-22 19:45:53

© 2024 FCC.report