Test Report

FCC ID: 2AHAY-SR6G1601

Test Report

Download: PDF
FCCID_2890629

                                              FCC PART 15 B
                                               TEST REPORT
                                                              For

                     SZ DJI BaiWang Technology Co.,Ltd
             Building No.1.2.7.9,Baiwang Creative Factory, No.1051,Songbai Road, Nanshan Xili
                                         District,Shenzhen,China


                                      FCC ID: 2AHAY-SR6G1601


                  Report Type:                                       Product Type:
                  Original Report                                    X5R READER



                          Test Engineer: Jone Lv


                       Report Number: RDG160119002-00


                            Report Date: 2016-01-22

                                        Harry Wu
                           Reviewed By: EMC Leader

                      Test Laboratory:         Bay Area Compliance Laboratories Corp. (Dongguan)
                                               No.69 Pulongcun, Puxinhu Industrial Zone,
                                               Tangxia, Dongguan, Guangdong, China
                                               Tel: +86-769-86858888
                                               Fax: +86-769-86858891
                                               www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan).


Bay Area Compliance Laboratories Corp. (Dongguan)                                                                         Report No.: RDG160119002-00




                                                       TABLE OF CONTENTS

GENERAL INFORMATION .......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 TEST FACILITY .............................................................................................................................................................4
SYSTEM TEST CONFIGURATION ..........................................................................................................................5
  DESCRIPTION OF TEST CONFIGURATION ......................................................................................................................5
  EUT EXERCISE SOFTWARE ..........................................................................................................................................5
  EQUIPMENT MODIFICATIONS .......................................................................................................................................5
  LOCAL SUPPORT EQUIPMENT LIST AND DETAILS ........................................................................................................5
  SUPPORT CABLE LIST AND DETAILS ............................................................................................................................5
  CONFIGURATION OF TEST SETUP .................................................................................................................................6
SUMMARY OF TEST RESULTS ...............................................................................................................................7
FCC§15.107 - CONDUCTED EMISSIONS ................................................................................................................8
  MEASUREMENT UNCERTAINTY ....................................................................................................................................8
  EUT SETUP ..................................................................................................................................................................8
  EMI TEST RECEIVER SETUP .........................................................................................................................................9
  TEST EQUIPMENT LIST AND DETAILS ...........................................................................................................................9
  TEST PROCEDURE ........................................................................................................................................................9
  CORRECTED AMPLITUDE & MARGIN CALCULATION ...................................................................................................9
  TEST RESULTS SUMMARY ..........................................................................................................................................10
  TEST DATA ................................................................................................................................................................10
FCC §15.109 - RADIATED SPURIOUS EMISSIONS ............................................................................................13
  MEASUREMENT UNCERTAINTY ..................................................................................................................................13
  EUT SETUP ................................................................................................................................................................13
  EMI TEST RECEIVER SETUP .......................................................................................................................................14
  TEST PROCEDURE ......................................................................................................................................................14
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................14
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................15
  TEST RESULTS SUMMARY ..........................................................................................................................................15
  TEST DATA ................................................................................................................................................................15
  ENVIRONMENTAL CONDITIONS ..................................................................................................................................15




FCC Part 15 B                                                                                                                                             Page 2 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: RDG160119002-00


GENERAL INFORMATION

Product Description for Equipment Under Test (EUT)
The SZ DJI BaiWang Technology Co.,Ltd’s product, model number: SR6G (FCC ID: 2AHAY-SR6G1601) (the
"EUT") in this report was a X5R READER , which was measured approximately:7.2 cm (L) x 5.6cm (W) x 1.5 cm
(H), rated input voltage: DC5.0V charging from system. The highest operating frequency is 30MHz.

 All measurement and test data in this report was gathered from production sample serial number: 160119002
 (Assigned byBACL, Dongguan). The EUT was received on 2016-01-14.



Objective

This test report is prepared on behalf of SZ DJI BaiWang Technology Co.,Ltd in accordance with Part 2,
Subpart J, and Part 15-Subparts A and B of the Federal Communications Commission’s rules.

The objective of the manufacturer is to determine the compliance of EUT with FCC Part 15 B Class B.


Related Submittal(s)/Grant(s)

Submitted with the Part of a system with FCC ID: 2AHAY-S5121601.


Test Methodology

All measurements contained in this report were conducted with ANSI C63.4-2014, American National
Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and
Electronic Equipment in the range of 9 kHz to 40 GHz.

All radiated and conducted emissions measurement was performed at Bay Area Compliance Laboratories
Corp. (Dongguan).




FCC Part 15 B                                                                                      Page 3 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: RDG160119002-00

Test Facility

The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located on the
No.69 Pulongcun, Puxinhu Industrial Zone, Tangxia, Dongguan, Guangdong, China

Test site at Bay Area Compliance Laboratories Corp. (Dongguan) has been fully described in reports submitted to
the Federal Communications Commission (FCC). The details of these reports have been found to be in
compliance with the requirements of Section 2.948 of the FCC Rules on February 06, 2015.

The Federal Communications Commission has the reports on file and is listed under FCC Registration No.:
273710. The test site has been approved by the FCC for public use and is listed in the FCC Public Access Link
(PAL) database.




FCC Part 15 B                                                                                     Page 4 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: RDG160119002-00


SYSTEM TEST CONFIGURATION

Description of Test Configuration

The system was configured for testing in a typical fashion (as normally used by a typical user).


EUT Exercise Software
N/A.


Equipment Modifications

No modification was made to the EUT tested.

Local Support Equipment List and Details

         Manufacturer                     Description             Model                Serial Number
                HP                          Printer               C3990A               JPZW030603
                SAST                        Modem                AEM-2100                090200213
                DELL                       Keyboard              SK-8115        CN-0J4628-71616-52H-0RT6
                DJI                            SSD                 S512                      N/A
                DELL                        Laptop                PP11L                      N/A



Support Cable List and Details

                                                        Length
                      Cable Description                                    From Port                  To
                                                         (m)
          Shielded Detachable Parallel Cable             1.5       Parallel Port of Laptop          Printer
           Shielded Detachable Serial Cable              1.5        Serial Port of Laptop          Modem
           Shielded Undetachable USBCable                2.0        USB Port of Laptop             Keyboard
          Unshielded Detachable USB Cable                0.5        USB Port of Laptop               EUT




FCC Part 15 B                                                                                      Page 5 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RDG160119002-00


Configuration of Test Setup




FCC Part 15 B                                                        Page 6 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                Report No.: RDG160119002-00


SUMMARY OF TEST RESULTS

           FCC Rules                       Description of Test              Results

                §15.107                    Conducted Emissions            Compliance

                §15.109                     Radiated Emissions            Compliance




FCC Part 15 B                                                                         Page 7 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG160119002-00


FCC§15.107 - CONDUCTED EMISSIONS

Measurement Uncertainty

All measurements involve certain levels of uncertainties, especially in field of EMC. The factors
contributing to uncertainties are Receiver, cable loss, and LISN.

Compliance or non- compliance with a disturbance limit shall be determined in the following manner:

If Ulab is less than or equal to Ucispr of Table 1, then:
–compliance is deemed to occur if no measured disturbance level exceeds the disturbance limit;
–non - compliance is deemed to occur if any measured disturbance level exceeds the disturbance limit.
If Ulab is greater than Ucispr of Table 1, then:
–compliance is deemed to occur if no measured disturbance level, increased by (Ulab − Ucispr), exceeds the
disturbance limit;
–non - compliance is deemed to occur if any measured disturbance level, increased by (Ulab − Ucispr), exceeds the
disturbance limit.

Based on CISPR 16-4-2: 2011, measurement uncertainty of conducted disturbance at mains port using AMN at
Bay Area Compliance Laboratories Corp. (Dongguan) is 3.12 dB (150 kHz to 30 MHz).

                                            Table 1 – Values of Ucispr

                                  Measurement                                                Ucispr
Conducted disturbance at mains port using AMN (150 kHz to 30 MHz)                           3.4 dB



EUT Setup




FCC Part 15 B                                                                                         Page 8 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                                  Report No.: RDG160119002-00

The setup of EUT is according with per ANSI C63.4-2014 measurement procedure. The specification used
was with the FCC Part 15 B Class B limits.

The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the middle.

The adapter of laptop was connected to a 120V/60Hz AC power source.


EMI Test Receiver Setup

The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

                                 Frequency Range                          IF B/W
                                150 kHz – 30 MHz                           9 kHz



Test Equipment List and Details

                                                                                   Calibration     Calibration
      Manufacturer           Description          Model        Serial Number
                                                                                      Date          Due Date
           R&S            EMI Test Receiver      ESCS 30        830245/006         2015-10-20      2016-10-20
           R&S                 L.I.S.N           ESH2-Z5        892107/021         2015-07-16      2016-07-15
                              Two-line
           R&S                                   ENV 216        3560.6550.12       2015-11-26      2016-11-25
                            V-network
           R&S             Test Software          EMC32        Version8.53.0          N/A              N/A

    * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
     been performed, traceable to National Primary Standards and International System of Units (SI).


Test Procedure

During the conducted emission test, the adapter of laptop was connected to the outlet of the first LISN and
the other support equipments were connected to the outlet of the second LISN.

Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All data was recorded in the Quasi-peak and average detection mode.


Corrected Amplitude & Margin Calculation

The basic equation is as follows:

VC = VR + AC + VDF




FCC Part 15 B                                                                                          Page 9 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: RDG160119002-00

Herein,
VC: corrected voltage amplitude

VR: reading voltage amplitude

Ac: attenuation caused by cable loss

VDF: voltage division factor of AMN or ISN

The “Margin” column of the following data tables indicates the degree of compliance within the applicable limit.
For example, a margin of 7dB means the emission is 7dB below the maximum limit. The equation for margin
calculation is as follows:

        Margin = Limit – Corrected Amplitude


Test Results Summary

According to the recorded data in following table, the EUT complied with the FCC Part 15 B Class B, with
the worst margin reading of:

                          10.5 dB at 0.429420 MHz in the Neutral conducted mode

Test Data

     Environmental Conditions


               Temperature:               21.6 °C
          Relative Humidity:               48 %
             ATM Pressure:               100.2kPa


    The testing was performed by Jone Lv on 2016-01-19.




FCC Part 15 B                                                                                      Page 10 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                                           Report No.: RDG160119002-00

     Test Mode: Downloading

AC120V, 60Hz, Line:


                          70


                                                                                                    Quasi-Peak Limit
                          60


                                                                                                       Average Limit
                          50


                          40
           Level in dBμ




                          30


                          20


                          10


                          0
                          150k      300   400 500     800 1M        2M     3M     4M 5M 6   8 10M         20M     30M
                                                                Frequency in Hz



      Frequency                  QuasiPeak          Bandwidth               Corr.      Margin    Limit
                                                                   Line                                         Comment
        (MHz)                     (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
       0.150000                     46.0              9.000         L1       9.8        20.0      66.0          Compliance
       0.335433                     37.2              9.000         L1       9.7        22.1      59.3          Compliance
       0.384091                     37.4              9.000         L1       9.8        20.8      58.2          Compliance
       0.436318                     37.6              9.000         L1       9.8        19.5      57.1          Compliance
       1.144267                     34.6              9.000         L1       9.8        21.4      56.0          Compliance
       1.536622                     34.1              9.000         L1       9.8        21.9      56.0          Compliance

      Frequency                   Average           Bandwidth               Corr.      Margin    Limit
                                                                   Line                                         Comment
        (MHz)                     (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
       0.150000                     38.8              9.000         L1       9.8        17.2      56.0          Compliance
       0.335433                     34.7              9.000         L1       9.7        14.6      49.3          Compliance
       0.381043                     35.6              9.000         L1       9.8        12.7      48.3          Compliance
       0.429420                     35.3              9.000         L1       9.8        12.0      47.3          Compliance
       0.432855                     36.3              9.000         L1       9.8        10.9      47.2          Compliance
       1.385415                     29.3              9.000         L1       9.8        16.7      46.0          Compliance




FCC Part 15 B                                                                                                      Page 11 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                                             Report No.: RDG160119002-00

AC120V, 60Hz, Neutral:



                          70

                                                                                                      Quasi-Peak Limit
                          60

                                                                                                         Average Limit
                          50


                          40
           Level in dBμ




                          30


                          20


                          10


                           0


                          -10
                            150k      300   400 500     800 1M        2M     3M     4M 5M 6   8 10M         20M     30M
                                                                  Frequency in Hz



      Frequency                    QuasiPeak          Bandwidth               Corr.      Margin    Limit
                                                                     Line                                         Comment
        (MHz)                       (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
       0.150000                       45.6              9.000         N        9.7        20.4      66.0          Compliance
       0.387164                       35.7              9.000         N        9.7        22.4      58.1          Compliance
       0.436318                       38.0              9.000         N        9.7        19.1      57.1          Compliance
       1.209904                       33.8              9.000         N        9.8        22.2      56.0          Compliance
       1.430284                       35.6              9.000         N        9.8        20.4      56.0          Compliance
       1.624765                       35.0              9.000         N        9.8        21.0      56.0          Compliance

      Frequency                     Average           Bandwidth               Corr.      Margin    Limit
                                                                     Line                                         Comment
        (MHz)                       (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
       0.335433                       34.9              9.000         N        9.7        14.4      49.3          Compliance
       0.381043                       34.6              9.000         N        9.7        13.7      48.3          Compliance
       0.429420                       36.8              9.000         N        9.7        10.5      47.3          Compliance
       0.432855                       29.1              9.000         N        9.7        18.1      47.2          Compliance
       0.576662                       29.0              9.000         N        9.7        17.0      46.0          Compliance
       1.385415                       29.1              9.000         N        9.8        16.9      46.0          Compliance




FCC Part 15 B                                                                                                        Page 12 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG160119002-00


FCC §15.109 - RADIATED SPURIOUS EMISSIONS

Measurement Uncertainty

Compliance or non- compliance with a disturbance limit shall be determined in the following manner:

If Ulab is less than or equal to Ucispr of Table 1, then:
–compliance is deemed to occur if no measured disturbance level exceeds the disturbance limit;
–non - compliance is deemed to occur if any measured disturbance level exceeds the disturbance limit.
If Ulab is greater than Ucispr of Table 1, then:
–compliance is deemed to occur if no measured disturbance level, increased by (Ulab − Ucispr), exceeds the
disturbance limit;
–non - compliance is deemed to occur if any measured disturbance level, increased by (Ulab − Ucispr), exceeds the
disturbance limit.

Based on CISPR 16-4-2: 2011, measurement uncertainty of radiated emission at a distance of 3m at Bay
Area Compliance Laboratories Corp. (Dongguan) is: 30M~200MHz: 4.58 dB for Horizontal, 4.59 dB for
Vertical; 200M~1GHz: 4.83 dB for Horizontal, 5.85 dB for Vertical; 1G~6GHz: 4.45 dB, 6G~18GHz: 5.23
dB

                                            Table 1 – Values of Ucispr

                                         Measurement                                                Ucispr
Radiated disturbance (electric field strength at an OATS or in a SAC) (30 MHz to 1000 MHz)         6.3 dB
Radiated disturbance (electric field strength in a FAR)               (1 GHz to 6 GHz)             5.2 dB
Radiated disturbance (electric field strength in a FAR)               (6 GHz to 18 GHz)            5.5 dB



EUT Setup

Below 1GHz:




FCC Part 15 B                                                                                      Page 13 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                                  Report No.: RDG160119002-00

The radiated emission tests were performed in the 3 meters chamber test site, using the setup accordance with the
ANSI C63.4-2014. The specification used was the FCC Part 15.109 Class B limits.


EMI Test Receiver Setup

The system was investigated from 30 MHz to 1 GHz.

During the radiated emission test, the EMI test receiver was set with the following configurations:


                 Frequency Range             RBW            Video B/W        IF B/W          Detector
                30 MHz – 1000 MHz          120 kHz           300 kHz         120 kHz            QP



Test Procedure

Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.

The data was recorded in the Quasi-peak detection mode for below 1 GHz.


Test Equipment List and Details

                                                                        Serial         Calibration   Calibration
    Manufacturer            Description              Model
                                                                       Number             Date        Due Date
         R&S             EMI Test Receiver           ESCI              100224          2015-08-03    2016-08-02
        Sunol
                              Antenna                 JB3              A060611-3       2014-11-06    2017-11-05
       Sciences
          HP                 Amplifier             8447E           2434A02181          2015-09-01    2016-09-01
        Agilent          Spectrum Analyzer        E4440A           SG43360054          2015-11-23    2016-11-22
     ETS-Lindgren          Horn Antenna             3115            9808-5557          2015-09-06    2018-09-06
      Mini-Circuit           Amplifier          ZVA-213-S+          054201245          2015-02-19    2016-02-19
         Farad             Test Software         EZ-EMC              V1.1.4.2             N/A           N/A

  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
    have been performed, traceable to National Primary Standards and International System of Units (SI).




FCC Part 15 B                                                                                           Page 14 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                            Report No.: RDG160119002-00


Corrected Amplitude & Margin Calculation

The Corrected Amplitude is calculated by adding the Antenna Loss and Cable Loss, and subtracting the Amplifier
Gain from the Meter Reading. The basic equation is as follows:

        Corrected Amplitude = Meter Reading + Antenna Loss + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable limit.
For example, a margin of 7 dB means the emission is 7 dB below the limit. The equation for margin calculation
is as follows:

        Margin = Limit – Corrected Amplitude


Test Results Summary

According to the data in the following table, the EUT complied with the FCC Part 15 B Class B, with the worst
margin reading of:

                              6.80 dB at 176.4700 MHz in the Vertical polarization


Test Data

Environmental Conditions


              Temperature:              20.8 °C
         Relative Humidity:              59 %
            ATM Pressure:              101.2 kPa

     * The testing was performed by Jone Lv on 2016-01-22.

     Test Result: Compliance




FCC Part 15 B                                                                                    Page 15 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG160119002-00

     Test Mode: Downloading

     Horizontal




                    Receiver                    Correction     Cord.
    Frequency                     Detector                                   Limit       Margin
                    Reading                      Factor        Amp.
      (MHz)                     (PK/QP/Avg)                                (dBμV/m)       (dB)
                    (dBμV)                       (dB/m)      (dBμV/m)
     176.4700        39.62           QP             -8.42     31.20          43.50        12.30
     194.9000        38.88           QP             -7.88     31.00          43.50        12.50
     239.5200        39.51           QP             -7.41     32.10          46.00        13.90
     284.1400        37.29           QP             -5.69     31.60          46.00        14.40
     313.2400        37.68           QP             -4.98     32.70          46.00        13.30
     862.2600        30.80           QP             3.70      34.50          46.00        11.50




FCC Part 15 B                                                                            Page 16 of 17


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG160119002-00

Vertical




                    Receiver                    Correction     Cord.
    Frequency                     Detector                                   Limit       Margin
                    Reading                      Factor        Amp.
      (MHz)                     (PK/QP/Avg)                                (dBμV/m)       (dB)
                    (dBμV)                       (dB/m)      (dBμV/m)
     30.0000         29.70           QP              1.70     31.40          40.00         8.60
     62.9800         35.98           QP             -12.58    23.40          40.00        16.60
     121.1800        33.47           QP              -5.87    27.60          43.50        15.90
     176.4700        45.12           QP              -8.42    36.70          43.50         6.80
     284.1400        37.69           QP              -5.69    32.00          46.00        14.00
     480.0800        28.06           QP              -1.26    26.80          46.00        19.20



                                  ***** END OF REPORT *****




FCC Part 15 B                                                                            Page 17 of 17



Document Created: 2016-01-28 17:36:29
Document Modified: 2016-01-28 17:36:29

© 2024 FCC.report