RF Exposure Info

FCC ID: 2AH9Q-MC-6A

RF Exposure Info

Download: PDF
FCCID_3366255

                                FCC ID: 2AH9Q-MC-6A
                                  Portable device
    According to §15.247(e)(i) and §1.1307(b)(1), systems operating under the provisions of this
    section shall be operated in a manner that ensures that the public is not exposed to radio
    frequency energy level in excess of the Commission’s guidelines.
    According to KDB447498 D01 General RF Exposure Guidance V05
    The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
    ≤ 50 mm are determined by:
    [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] *
    [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where
    f(GHz) is the RF channel transmit frequency in GHz;
    Power and distance are rounded to the nearest mW and mm before calculation;
    The result is rounded to one decimal place for comparison;
    The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm
    and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test
    separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion.
    We use 5mm as separation distance to calculate.

    Maximum measured transmitter power:

    BT DTS:
                                Mode                Max          tune up maximum        Result
Transmit Frequency
                                                  Conducted            power          calculation      1-g SAR
       (GHz)
                                                 Power (dBm)
       2.402                    GFSK                 2.01         1dBm to 3dBm           0.618           3.0
       2.441                    GFSK                 1.49         0dBm to 2dBm           0.495           3.0
       2.480                    GFSK                 1.05         0dBm to 2dBm           0.499           3.0




    Conclusion:
    For the max result : 0.618≤ 3.0 for 1-g SAR extremity SAR, No SAR is required.


    Signature:                                                                  Date: 2017-03-29



    NAME AND TITLE (Please print or type): David Lee/Manager
    COMPANY (Please print or type): EMTEK (Shenzhen) Co., Ltd./Building 69, Majialong Industry
    Zone, Nanshan District, Shenzhen, Guangdong, China



Document Created: 2017-04-11 16:01:05
Document Modified: 2017-04-11 16:01:05

© 2024 FCC.report