RF Exposure Report

FCC ID: 2AH4HVZASSETCM1

RF Exposure Info

Download: PDF
FCCID_4505887

                            MPE TEST REPORT


                Applicant             Quectel Wireless Solutions Co., Ltd

                FCC ID                XMR201705BG96NA

                Product               LTE Cat M1 Module

                Brand                 Quectel

                Model                 BG96-NA

                Report No.            R1907A0353-M1

                Issue Date            August 2, 2019


TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in FCC
47 CFR Part 1 1.1310. The test results show that the equipment tested is capable of demonstrating compliance
with the requirements as documented in this report.




                    Performed by: Yu Wang                        Approved by: Kai Xu




               TA Technology (Shanghai) Co., Ltd.
                  No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China
                                        TEL: +86-021-50791141/2/3
                                     FAX: +86-021-50791141/2/3-8000


               MPE Test Report                                                                             Report No: R1907A0353-M1




                                                     Table of Contents
1  Test Laboratory .............................................................................................................................. 3
 1.1   Notes of the Test Report ......................................................................................................... 3
 1.2   Test facility .............................................................................................................................. 3
 1.3   Testing Location ...................................................................................................................... 4
 1.4   Laboratory Environment .......................................................................................................... 4
2 Description of Equipment under Test ............................................................................................. 5
3 Maximum conducted output power (measured) and antenna Gain ................................................ 6
ANNEX A: The EUT Appearance ..................................................................................................... 10
 A.1 EUT Appearance ....................................................................................................................... 10
ANNEX B: Product Change Description .............................................................................................. 11




TA Technology (Shanghai) Co., Ltd.                                                                                 Page 2 of 11
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


             MPE Test Report                                                                 Report No: R1907A0353-M1




1 Test Laboratory

1.1 Notes of the Test Report

This report shall not be reproduced in full or partial, without the written approval of TA technology

(shanghai) co., Ltd. The results documented in this report apply only to the tested sample, under the

conditions and modes of operation as described herein .Measurement Uncertainties were not taken

into account and are published for informational purposes only. This report is written to support

regulatory compliance of the applicable standards stated above. This report must not be used by the

client to claim product certification, approval, or endorsement by any government agencies.


1.2 Test facility

CNAS (accreditation number:L2264)
TA Technology (Shanghai) Co., Ltd. has obtained the accreditation of China National Accreditation
Service for Conformity Assessment (CNAS).
FCC (recognition number is 428261)
TA Technology (Shanghai) Co., Ltd. has been listed on the US Federal Communications Commission
list of test facilities recognized to perform electromagnetic emissions measurements.
IC (recognition number is 8510A)
TA Technology (Shanghai) Co., Ltd. has been listed by industry Canada to perform electromagnetic
emission measurement.
VCCI (recognition number is C-4595, T-2154, R-4113, G-766)
TA Technology (Shanghai) Co., Ltd. has been listed by industry Japan to perform electromagnetic
emission measurement.
A2LA (Certificate Number: 3857.01)
TA Technology (Shanghai) Co., Ltd. has been listed by American Association for Laboratory
Accreditation to perform electromagnetic emission measurement.




TA Technology (Shanghai) Co., Ltd.                                                                                 Page 3 of 11
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


             MPE Test Report                                                                 Report No: R1907A0353-M1


1.3 Testing Location


   Company:             TA Technology (Shanghai) Co., Ltd.

   Address:             No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China

   City:                Shanghai

   Post code:           201201
   Country:             P. R. China

   Contact:             Xu Kai

   Telephone:           +86-021-50791141/2/3

   Fax:                 +86-021-50791141/2/3-8000
   Website:             http://www.ta-shanghai.com

   E-mail:              xukai@ta-shanghai.com




1.4 Laboratory Environment

   Temperature                                             Min. = 18C, Max. = 25 C

   Relative humidity                                       Min. = 30%, Max. = 70%

   Ground system resistance                                < 0.5 
   Ambient noise is checked and found very low and in compliance with requirement of standards.
   Reflection of surrounding objects is minimized and in compliance with requirement of standards.




TA Technology (Shanghai) Co., Ltd.                                                                                 Page 4 of 11
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


             MPE Test Report                                                                 Report No: R1907A0353-M1



2 Description of Equipment under Test

 Client Information
   Applicant                              Quectel Wireless Solutions Co., Ltd
                                          Building 5, Shanghai Business Park Phase III (Area B), No.1016
   Applicant address
                                          Tianlin Road, Minhang District, Shanghai, China 200233
   Manufacturer                           Quectel Wireless Solutions Co., Ltd
                                          Building 5, Shanghai Business Park Phase III (Area B), No.1016
   Manufacturer address
                                          Tianlin Road, Minhang District, Shanghai, China 200233


General Technologies
   Model:                      Quectel BG96-NA
   IMEI:                       864508030799925
   Hardware Version:           R1.0
   Software Version:           BG96NAMAR02A09M1G
                               The EUT don’t have standard Antenna, The Antenna used for testing in
   Antenna Type:
                               this report is the after-market accessory (Dipole Antenna)
   Antenna Gain:               The Maximum Antennea Gain(4dBi) is declared by manufacturer
   Test Date:                  May 15, 2017 ~ May 17, 2017 and July 10, 2019 ~ July 19, 2019


                                                Accessory equipment
   Evaluation Board                                          RF Cable
   RS232-to-USB Cable                                        Antenna: Dipole Antenna
   Headset                                                   USB Cable


BG96-NA (Report No.:R1907A0353-M1) is a variant model of BG96-NA (Report No.:
RXA1705-0129MPE01R1). This report adds LTE band 2 and LTE band 12. The detailed product
change description please refers to the ANNEX B.




TA Technology (Shanghai) Co., Ltd.                                                                                 Page 5 of 11
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


             MPE Test Report                                                                 Report No: R1907A0353-M1



3 Maximum conducted output power (measured) and antenna Gain

the numeric gain (G) of the antenna with a gain specified in dB is determined by
Numeric gain (G)=10^(antenna gain/10)


                                           Maximum Conducted Output                  Antenna Gain            Numeric gain
                Band
                                                 Power (dBm)                             (dBi)                  (dB)

            LTE Band 2                                    25.7                               4                   2.512
            LTE Band 4                                    25.7                               4                   2.512
           LTE Band 12                                    25.7                               4                   2.512
           LTE Band 13                                    25.7                               4                   2.512




TA Technology (Shanghai) Co., Ltd.                                                                                 Page 6 of 11
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


                  MPE Test Report                                                                 Report No: R1907A0353-M1

         According to section 1.1310 of FCC 47 CFR Part 1, limits for maximum permissible exposure

         (MPE) are as following




Note1. Occupational/controlled limits apply in situations in which persons are exposed as a consequence of

       their employment provided those persons are fully aware of the potential for exposure and can

       exercise control over their exposure. Limits for occupational/controlled exposure also apply in

       situations when an individual is transient through a location where occupational / controlled limits apply

       provided he or she is made aware of the potential for exposure.

Note2: General population/uncontrolled exposures apply in situations in which the general public may be

       exposed, or in which persons that are exposed as a consequence of their employment may not be fully

       aware of the potential for exposure or can not exercise control over their exposure.




     TA Technology (Shanghai) Co., Ltd.                                                                                 Page 7 of 11
     This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              MPE Test Report                                                                 Report No: R1907A0353-M1
    The maximum permissible exposure for 300~1500MHz is f/1500, 1500~100,000MHz is 1.0.So




                         Band                                     The maximum permissible exposure


                     LTE Band 2                                                    1.0mW/cm2

                     LTE Band 4                                                    1.0mW/cm2

                    LTE Band 12                                                  0.470mW/cm2
                    LTE Band 13                                                  0.523mW/cm2



                        Maximum
                        Conducted            EIRP                      Power density Limit                          Final
                                                        Margin1                                      Margin2
         Band            Output              limit                                                                 Margin
                                                         (dB)                                         (dB)
                          Power             (dBm)                     (mW/cm2)          (dBm)                       (dB)
                          (dBm)
     LTE Band 2              25.7          33.000         7.300          1.000          37.013        11.313        7.300
     LTE Band 4              25.7          30.000         4.300          1.000          37.013        11.313        4.300
    LTE Band 12              25.7          36.920         11.220         0.470          33.734         8.033        8.033
    LTE Band 13              25.7          36.920         11.220         0.523          34.198         8.497        8.497
    Note: 1. The Maximum allowed antenna gain per Band should be less than or equal to the Final
    Margin which is the allowable maximum gain value to comply with limits for maximum
    permissible exposure (MPE).
    2. The Final Margin is determined and selected to the worst-case of Margin1 and Margin2.
    3. Margin1=EIRP Limit(dBm)-Maximum Conducted Power (dBm). EIRP limit reference standard
    part22/ part24/part27and part90 for each band, EIRP = ERP + 2.15 (dB).
    4. Margin2=Power density Limit(dBm)-Maximum Conducted Power (dBm). Power density
    Limit(dBm): The max. obtained by MPE with 20cm.




 IMPORTANT NOTE: To comply with the FCC RF exposure compliance requirements, the

antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20

cm from all persons and must not be co-located or operating in conjunction with any other antenna

or transmitter. No change to the antenna or the device is permitted. Any change to the antenna or

the device could result in the device exceeding the RF exposure requirements and void user’s

authority to operate the device.


 TA Technology (Shanghai) Co., Ltd.                                                                                 Page 8 of 11
 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


               MPE Test Report                                                                 Report No: R1907A0353-M1




RF Exposure Calculations:
 The following information provides the minimum separation distance for the highest gain antenna

 provided. This calculation is based on the conducted power, considering maximum power and antenna

 gain. The formula shown in KDB 447498 D01 is used in the calculation.

Equation from KDB 447498 D01 General RF Exposure Guidance v06 (10/23/2015) is:
                                                                        2
                                                        S= PG / 4∏R
                                                                             2
 Where:     S = power density (in appropriate units, e.g. mW/cm )

           P = Time-average maximum tune up procedure (in appropriate units, e.g., mW)

           G = the numeric gain of the antenna

           R = distance to the center of radiation of the antenna (20 cm = limit for MPE)

                                                                   Test Result         Limit Value
                        Band                     PG (mW)                         2                 2     Conclusion
                                                                    (mW/cm )            (mW/cm )
                    LTE Band 2                   1995.262             0.3969               1.000              Pass
                    LTE Band 4                   1000.000             0.1989               1.000              Pass
                   LTE Band 12                   2362.109             0.4699               0.470              Pass
                   LTE Band 13                   2628.452             0.5229               0.523              Pass
          Note: R = 20cm
               ∏= 3.1416




 Note: For transmitters, minimum separation distance is 20cm, even if calculations indicate MPE
        distance is less.




  TA Technology (Shanghai) Co., Ltd.                                                                                 Page 9 of 11
  This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


             MPE Test Report                                                                 Report No: R1907A0353-M1


ANNEX A: The EUT Appearance

  A.1 EUT Appearance




                                                      Picture 1 EUT




TA Technology (Shanghai) Co., Ltd.                                                                                Page 10 of 11
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


             MPE Test Report                                                                 Report No: R1907A0353-M1


ANNEX B: Product Change Description

                                                      Statement
                  We Quectel Wireless Solutions Co., Ltd declare the following models.

Product Name: LTE Cat M1 Module
Model Number:BG96-NA
Hardware Version: R1.0


             Module                     Category                                 Supported Band
            BG96-NA                      CAT M1                                  B2/B4/B12/B13


The HW design of BG96-NA is exactly the same with before,it just increasesB2/B12.BecauseB2
andB12 were disabled through software before and now be enabled. The hardware design and
software feature are exactly the same.

The change will not impact RF performance for original frequency bands.

Your assistance on this matter is highly appreciated.

Sincerely,
Name:Jean Hu
Title:Certification Section




TA Technology (Shanghai) Co., Ltd.                                                                                Page 11 of 11
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.



Document Created: 2019-09-05 10:35:04
Document Modified: 2019-09-05 10:35:04

© 2024 FCC.report