MPE Report

FCC ID: 2AH4HATD500S

RF Exposure Info

Download: PDF
FCCID_4061970

September 29, 2018

TÜV SÜD BABT
Octagon House, Concorde Way
Segensworth Rd N, Fareham
PO15 5RL

Attention: Director of Certification

RE: Analysis of RF Exposure for Portable and Mobile use per KDB 447498 D01 Mobile Portable RF
Exposure v06 and RSS-102 Issue 5 March 2015.

FCC ID: 2AH4HATD500S
IC: 21385-ATD500S

1.   Limits:

Limits for General Population/Uncontrolled Exposure (Title 47 Subpart J §2.1091 and KDB 447498 D01
referring to limits under §1.1310)

                            Electric Field           Electric Field          Power Density
 Frequency Range                                                                                     Averaging Time
                            Strength (E)             Strength (H)                  (S)
      (MHz)                                                                                            (minutes)
                               (V/m)                    (A/m)                  (mW/cm2)
       0.3 - 1.34                614                     1.63                    *(100)                      30
       1.34 - 30                824/f                   2.19/f                  *(180/f2)                    30
       30 - 300                 27.5                     0.073                     0.2                       30
      300 - 1500                  -                        -                     f/1500                      30
   1500 - 100,000                 -                        -                       1.0                       30
f = frequency in MHz
*Plane-wave equivalent power density

Limits for Devices Used by the General Public (Uncontrolled Environment (RSS-102 Issue 5 March 2015)

                            Electric Field
 Frequency Range                                    Magnetic Field           Power Density          Reference Period
                              Strength
      (MHz)                                          (A/m rms)                  (W/m2)                 (minutes)
                             (V/m rms)
     0.003 - 1021                83                        90                       -                 Instantaneous
       0.1 - 10                   -                      0.73/f                     -                      6**
       1.1 - 10                87/f0.5                      -                       -                      6**
        10 - 20                 27.46                    0.0728                     2                       6
        20 - 48              -58.07/f0.25             0.1540/f0.25              8.944/f0.5                  6
       48 - 300                 22.06                   0.05852                   1.291                     6



          TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400 FAX: 858 546 0364


       300 - 6000         3.142 f0.3417                0.008335 f.0.3417       0.02619 f0.6834                6
     6000 - 15000             61.4                          0.163                    10                       6
   15000 - 150000             61.4                          0.163                    10                   616000/f1.2
  150000 - 300000          0.158f0.5                    4.21 x 10.-4 f0.5       6.67 x 10.-5 f            616000/f1.2
f is frequency in MHz
*Based on nerve stimulation (NS)
** Based on specific absorption rate (SAR)

2.     Mobile MPE Calculation Summary using a 20cm separation distance:

                 Mode                                  Output Power                      Power Density (mW/cm2)
BT 5.0                                                  163 mW EIRP                                 0.0326
LTE B12 (worst case MPE ratio)                           447.92 mW                                  0.089

Note: The output power and power density presented here are from the MPE reports of the module used
(original filing):

                Module                                           FCC ID                            IC Number
BT 5.0 (Model: BGM13P22A)                                     QOQBGM13P                          5123A-BGM13P
Quectel BG96 LTE CAT M1 cellular radio                       XMR201707BG96                     10224A-201709BG96

Note: WiFi module (ESP8285 232016 POS717) is not included since it is configured for receive mode only

3.     Co-Located Transmitters transmission table:

           Transmitter type                           Transmitter type that can transmit at the same time
BT 5.0                                     Cellular
Cellular                                   BT 5.0

4.     Simultaneous Transmission MPE:


     Transmitter            MPE               FCC Limit          IC Limit         FCC MPE ratio         ISED MPE ratio
        type              (mw/cm2)           (mW/cm2)           (mW/cm2)           (MPE/Limit)            (MPE/Limit)
BT 5.0                      0.0326               1.00             0.54689             0.0326                 0.0596
Cellular                    0.0890               0.46             0.23017             0.1934                 0.3866
                                      Sum of the ratios (should be <1.0)              0.2260                 0.4462




            TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400 FAX: 858 546 0364


Sincerely,


Ferdie S. Custodio
Name
Authorized Signatory
Title: Senior EMC Test Engineer /Wireless Team Lead




         TÜV SÜD AMERICA INC 10040 Mesa Rim Road San Diego, CA 92121-2912 Phone: 858 678 1400 FAX: 858 546 0364