RF Exposure exempt report

FCC ID: 2AGPFVB20

Test Report

Download: PDF

                                                                                    REPORT No.:XM19050004W02




                                     RF EXPOSURE
                       EVALUATION REPORT

                 APPLICANT                      : Xiamen Retone Hearing Technology Co.,Ltd

                 PRODUCT NAME                   : Hearing Aid

                                                    VB20, Vigor, Vigor U, Vigor X, VB SERIES,
                 MODEL NAME                     :
                                                    Gio, Bro, Eggo

                 BRAND NAME                     : Retone

                 FCC ID                         : 2AGPFVB20

                                                    KDB 447498 D01v06
                 STANDARD(S)
                                                    47 CFR§2.1093

                 TEST DATE                      : 2019-05-17

                 ISSUE DATE                     : 2019-05-18




                                                      Prepared by:
                                                                                Lion Xiao(Project engineer)


                                                      Approved by:
                                                                                Anne Liu( Supervisor )




NOTE: 1.The report is invalid when there is no the approver signature and the special stamp for test report. 2.The test report
shall not be reproduced except in full without prior written permission of the company. 3.The report copy is invalid when there is
no the special stamp for test repor. 4.The altered report is invalid. 5.The entrust test is responsibility for the received sample
only.

 Kehu-Morlab            XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                                             Tel: +86 592 5612050
 Test Laboratory        Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China   Fax: +86 592 5612095


                                                                                  REPORT No.:XM19050004W02


                                                  DIRECTORY
 1. Technical Information········································································································3
 1.1. Applicant and manufacturer information ····································································3
 1.2. Equipment under test (EUT) description ·····································································3
 1.3. Applied reference documents ·······················································································3
 2. Device category and RF exposure limit··········································································4
 3. Measurement of conducted output power ·····································································5
 4. RF exposure evaluation ····································································································6
 Annex A General Information ·································································································7




                                                       Change History
           Version                            Date                                    Reason for change
              1.0                       2019-05-18                                          First edition




Kehu-Morlab           XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                                             Tel: +86 592 5612050
Test Laboratory       Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China   Fax: +86 592 5612095
                                                                                                                              Page2 0f 7


                                                                               REPORT No.:XM19050004W02

 1. Technical Information
 Note: Provide by manufacturer.

 1.1. Applicant and manufacturer information

   Applicant:                         Xiamen Retone Hearing Technology Co.,Ltd
                                      ROOM 103,NO.320 SOUTH TONGJI ROAD,JIMEI DISTRICT,
   Applicant Address:
                                      XIAMEN,CHINA
   Manufacturer:                      Xiamen Retone Hearing Technology Co.,Ltd
                                      ROOM 103,NO.320 SOUTH TONGJI ROAD,JIMEI DISTRICT,
   Manufacturer Address:
                                      XIAMEN,CHINA


 1.2. Equipment under test (EUT) description

  EUT Type:                    Hearing Aid
  Hardware Version:            V1.0
  Software Version:            V1.0
  Frequency Bands:             Bluetooth LE : 2402-2480MHz;
  Modulation Mode:             GFSK
  Antenna type:                Ceramic Antenna
 Note 4: Hearing Aid, model: VB20, Vigor, Vigor U, Vigor X, VB SERIES, Gio, Bro, Eggo, have the
 same circuit diagram, PCB layout, software, RF module and functionality. The differences are the
 shape of plastic case. We selected VB20 for fully conducted testing, the differences details was
 explained in the declaration letter.



 1.3. Applied reference documents

 Leading reference documents for testing:
   No.     Identity                          Document Title
   1       47 CFR§2.1093                     Radiofrequency Radiation Exposure Evaluation: portable
                                             devices
   2       KDB 447498 D01v06                 General RF Exposure Guidance




Kehu-Morlab        XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                                             Tel: +86 592 5612050
Test Laboratory    Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China   Fax: +86 592 5612095
                                                                                                                           Page3 0f 7


                                                                              REPORT No.:XM19050004W02

 2. Device category and RF exposure limit
 Per user manual, this device is a Hearing Aid. Based on 47CFR 2.1093, this device belongs to
 portable device category with General Population/Uncontrolled exposure.
 Portable Devices:
 47CFR 2.1093(b)
 For purposes of this section, a portable device is defined as a transmitting device designed to be
 used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the
 user.

 GENERAL POPULATION / UNCONTROLLED EXPOSURE
 47CFR 2.1093(d) (2)
 Limits for General Population/Uncontrolled exposure: 0.08 W/kg as averaged over the whole-body
 and spatial peak SAR not exceeding 1.6 W/kg as averaged over any 1 gram of tissue (defined as a
 tissue volume in the shape of a cube). Exceptions are the hands, wrists, feet and ankles where the
 spatial peak SAR shall not exceed 4 W/kg, as averaged over any 10 grams of tissue (defined as a
 tissue volume in the shape of a cube). General Population/Uncontrolled limits apply when the
 general public may be exposed, or when persons that are exposed as a consequence of their
 employment may not be fully aware of the potential for exposure or do not exercise control over
 their exposure. Warning labels placed on consumer devices such as cellular telephones will not be
 sufficient reason to allow these devices to be evaluated subject to limits for occupational/controlled
 exposure in paragraph (d)(1) of this section.




Kehu-Morlab       XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                                             Tel: +86 592 5612050
Test Laboratory   Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China   Fax: +86 592 5612095
                                                                                                                          Page4 0f 7


                                                                              REPORT No.:XM19050004W02

 3. Measurement of conducted peak output power
 Bluetooth LE peak output power
                                                Frequency                 Measured Output Peak Power
           Band            Channel
                                                     MHz                                    dBm
                                 0                  2402                                   -8.960
       Bluetooth LE             19                  2440                                   -9.351
                                39                  2480                                   -9.001
       Maximum tune-up limit power:                -8.5 dBm




Kehu-Morlab       XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                                             Tel: +86 592 5612050
Test Laboratory   Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China   Fax: +86 592 5612095
                                                                                                                          Page5 0f 7


                                                                              REPORT No.:XM19050004W02


 4. RF exposure evaluation
 The device only incorporates a Bluetooth transmitter, so standalone SAR evaluation is required for
 Bluetooth and simultaneous SAR is not required.

 Standalone transmission SAR evaluation

 According to KDB 447498 section 4.3.1, the 1-g SAR test exclusion thresholds at test separation
 Distances ≤ 50 mm are determined by:
 [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
 mm)]·[√f(GHz)] ≤ 3.0
 The maximum tune-up limit power is -8.5dBm (0.14mW) @ 2.402GHz
 When Bluetooth Headset is used on the head, so use 5mm as the most conservative minimum test
 separation distance,
 [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
 mm)]·[√f(GHz)] =0.043 ≤ 3.0
 So SAR measurement is not required for this device.




Kehu-Morlab       XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                                             Tel: +86 592 5612050
Test Laboratory   Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China   Fax: +86 592 5612095
                                                                                                                          Page6 0f 7


                                                                              REPORT No.:XM19050004W02

 Annex A General Information
 1. Identification of the Responsible Testing Laboratory
   Company Name:                               Kehu-Morlab Test Laboratory
   Address:                                    Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot
                                               Free Trade Zone (Fujian), P. R. China
   Responsible Test Lab Manager:               Mr. Di Dehai
   Telephone:                                  +86 592 5612050
   Facsimile:                                  +86 592 5612095

 2. Identification of the Responsible Testing Location
   Name:                                       Kehu-Morlab Test Laboratory
   Address:                                    Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot
                                               Free Trade Zone (Fujian), P. R. China




                                                 END OF REPORT




Kehu-Morlab       XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                                             Tel: +86 592 5612050
Test Laboratory   Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China   Fax: +86 592 5612095
                                                                                                                          Page7 0f 7



Document Created: 2019-05-24 16:38:31
Document Modified: 2019-05-24 16:38:31