Label

FCC ID: 2AGO22500

ID Label/Location Info

Download: PDF
FCCID_2868953

Inspire Model 2500 ID Label/Location Info
FCC ID: 2AGO22500

Device dimensions: 4.7” x 2.7” x 1.1”

Label dimensions: 2.0” x 2.3”

Underside surface of device:


         8                  7                  6                 5                    4                   3                                            2                                              1

    FCC ID in diagram is for info only, see page 1 for actual FCC ID


D                                                                                                                                                                                                                                   D




                                                   GRAPHITE (UN7994, RGB: 38,45,51)
                                        .015                                                                                 NOTES:

                                                                                                                  CTQ-1      1. MATERIAL: .010 LEXAN 8B35V FILM WITH 3M
                                                                                                                             7952MP REAR ADHESIVE (.002). SCREEN PRINT
                                                                                                                             GRAPHICS ON SECOND SURFACE PER THE PROVIDED
                                                                                                                             ILLUSTRATOR FILE USING SERICOL TECHMARK INKS (OR
                                                                                                                             EQUIVALENT). MATERIAL CERTIFICATION TO BE
                                                                                                                             PROVIDED WITH EACH LOT.

                                                                                                                             2. UNTOLERANCED DIMENSIONS ARE REFERENCE
                                                                                                                             DIMENSIONS. SEE CAD MODEL FOR COMPLETE
C                                                                                                                            GEOMETRY DEFINITION. CTQ ARE CRITICAL                                                                  C
                                                                                                                             INSPECTION DIMENSIONS FOR SUPPLIER (2).

                                                                                                                             3. THE PARTS SHALL BE PACKAGED IN A MANNER THAT
                                                                                                                             PREVENTS DAMAGE OR CONTAMINATION FROM
                                                                                                                             FOREIGN MATERIAL. EACH MANUFACTURING LOT
                                                                                          2.294±.015                         SHALL BE LABELED IN ACCORDANCE WITH INSPIRE
                                                                                                                             SPEC 700-006-000.
                                                                                                  CTQ-2
                                                                                                                             4. UPON APPROVAL BY INSPIRE MEDICAL SYSTEMS OF
                                                                                                                             THE INITIAL DESIGN, ANY PROCESS CHANGES, DESIGN
                                                                                                                             CHANGES, PACKAGING CHANGES, RAW MATERIAL
                                                                                                                             CHANGES, OR DEVIATIONS CONSIDERED BY THE
                                                                                                                             MANUFACTURER MUST BE SUBMITTED TO INSPIRE IN
                                                                                                                             WRITNG FOR PRE-APPROVAL. THE INFORMATION
                                                                                                                             SUBMITTED SHALL INCLUDE A COMPLETE DESCRIPTION
                                                                                                                             OF THE CHANGE AND THE EFFECT THE CHANGE WILL
             WHITE                                                                                                           HAVE ON ALL THE CHARACTERISTICS OF THE
B                                                                                                                            DEVICE/MATERIAL. UPON REQUEST, THE                                                                     B
                                                                                                                             MANUFACTURER SHALL SUBMIT SAMPLES OF THE
                                                                                                                             PROPOSED DEVICE/MATERIAL FOR EVALUATION AND
                                                                               .012                                          APPROVAL BY INSPIRE MEDICAL SYSTEMS.




                                1.958

A                                                                                                                                                                                                                                   A
                                                                                                                      PROPERTY AND CONFIDENTIAL                                      Inspire Medical Systems, Inc.
                                                                                                                       The information contained                                     Maple Grove, MN USA
                                                                                                                         in this drawing is the sole
                                                                                                                          property of Inspire. Any
                                                                                                                        reproduction in part or as
                                                                                                                            a whole without the
                                                                                                                               express written
                                                                                                                           permission of Inspire is  TITLE:   LABEL, BATTERY DOOR,
                                                                                                                             strictly prohibited.
                                                                                                                                                              MODEL 2500
                                                                                                                          X.X .1                       DOCUMENT CREATED BY:   DATE         APPROVED              DATE

                                                                                                                          X.XX .01                     T. YOCH                06/10/2015   K. VERZAL             07/07/2015
                                                                                                                          X.XXX .005                   SIZE   DWG NO.                                     REV.     SHEET

                                                                                                                          ANGLES 2.0
                                                                                                                                                       B 200-138-000                                      05        1      OF   1
         8              7                      6                  5                   4                       3                                       2                                               1