1        Cover Page

                                      FCC REPORT
Applicant:                                 Autel Robotics Co., Ltd

Address of Applicant:                      9th Floor, Bldg. B1, Zhiyuan,1001 Xueyuan Rd., Xili, Nanshan,
                                           Shenzhen, China
Equipment Under Test (EUT)

    Product Name:                          Live Deck

    Model No.:                             Live Deck

    Trade mark:                            AUTEL

FCC ID:                                    2AGNTLDK2409A

Applicable standards:                      FCC CFR Title 47 Part 15 Subpart B

Date of sample receipt:                    21 Mar., 2019

Date of Test:                              21 Mar., to 01 Apr., 2019

Date of report issued:                     01 Apr., 2019

Test Result:                               PASS *
  * In the configuration tested, the EUT complied with the standards specified above.




 Authorized Signature:




       Bruce Zhang
    Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other
samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer should ensure that all
products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in
the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or
falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days
only.


                                                                                 Report No: CCISE190306902

2      Version
      Version No.                            Date                                  Description
             00                         01 Apr., 2019                                Original




    Tested by:                                                           Date:          01 Apr., 2019

                                       Test Engineer

    Reviewed by:                                                         Date:          01 Apr., 2019

                                    Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                          Project No.: CCISE1903069
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                         Page 2 of 18


                                                                                                                            Report No: CCISE190306902

3         Contents
                                                                                                                                                                                 Page
1     COVER PAGE ....................................................................................................................................................... 1
2     VERSION ............................................................................................................................................................... 2
3     CONTENTS ........................................................................................................................................................... 3
4     TEST SUMMARY .................................................................................................................................................. 4
5     GENERAL INFORMATION .................................................................................................................................. 5
    5.1    CLIENT INFORMATION ...................................................................................................................................................... 5
    5.2    GENERAL DESCRIPTION OF E.U.T. ...................................................................................................................................... 5
    5.3    TEST MODE.................................................................................................................................................................... 5
    5.4    MEASUREMENT UNCERTAINTY ........................................................................................................................................... 5
    5.5    DESCRIPTION OF SUPPORT UNITS ....................................................................................................................................... 6
    5.6    RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................................................... 6
    5.7    DESCRIPTION OF CABLE USED ............................................................................................................................................ 6
    5.8    LABORATORY FACILITY ...................................................................................................................................................... 6
    5.9    LABORATORY LOCATION ................................................................................................................................................... 6
    5.10      TEST INSTRUMENTS LIST ............................................................................................................................................... 7
6     TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8
    6.1    CONDUCTED EMISSION ..................................................................................................................................................... 8
    6.2    RADIATED EMISSION ...................................................................................................................................................... 11
7     TEST SETUP PHOTO ........................................................................................................................................ 17
8     EUT CONSTRUCTIONAL DETAILS ................................................................................................................ 18




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                               Project No.: CCISE1903069
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                                                        Page 3 of 18


                                                                              Report No: CCISE190306902

4      Test Summary
                 Test Item                                Section in CFR 47                 Result
           Conducted Emission                                 Part 15.107                    Pass
            Radiated Emission                                 Part 15.109                    Pass
 Remark:
 Pass: The EUT complies with the essential requirements in the standard.
 N/A: The EUT not applicable of the test item.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                       Project No.: CCISE1903069
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                      Page 4 of 18


                                                                              Report No: CCISE190306902

5      General Information
5.1 Client Information
        Applicant:                              Autel Robotics Co., Ltd
        Address:                                9th Floor, Bldg. B1, Zhiyuan, 1001 Xueyuan Rd., Xili, Nanshan,
                                                Shenzhen, China
        Manufacturer/ Factory:                  Autel Robotics Co., Ltd
        Address:                                9th Floor, Bldg.B1, Zhiyuan, 1001 Xueyuan Rd., Xili, Nanshan,
                                                Shenzhen, China

5.2 General Description of E.U.T.
        Product Name:                           Live Deck
        Model No.:                              Live Deck
        Power supply:                           Rechargeable Li-ion Battery DC3.7V-5000mAh
                                                Model: XA3_130
                                                Input: AC100-240V, 50/60Hz, 1.5A
        AC adapter :
                                                Output: DC 13.05V, 3.83A (main port)
                                                5V, 3.0A/ 9V, 2A/ 12V, 1.5A(USB port)
        Test Sample Condition:                  The test samples were provided in good working order with no
                                                visible defects.

5.3 Test Mode
           Operating mode               Detail description
                                      Keep the EUT in 2.4G Link and HDMI Output Playing and USB Output
           Full Load mode
                                      Playing mode
 The sample was placed 0.8m above the ground plane of 3m chamber. Measurements in both horizontal and
 vertical polarities were performed. During the test, each emission was maximized by: having the EUT
 continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered
 typical configuration to obtain worst position, manipulating interconnecting cables, rotating the turntable,
 varying antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst-case
 are shown in Test Results of the following pages.

5.4 Measurement Uncertainty
                    Parameters                                             Expanded Uncertainty
        Conducted Emission (9kHz ~ 30MHz)                                     ±2.22 dB (k=2)
         Radiated Emission (9kHz ~ 30MHz)                                     ±2.76 dB (k=2)
       Radiated Emission (30MHz ~ 1000MHz)                                    ±4.28 dB (k=2)
        Radiated Emission (1GHz ~ 18GHz)                                      ±5.72 dB (k=2)
        Radiated Emission (18GHz ~ 40GHz)                                     ±2.88 dB (k=2)




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1903069
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                           Page 5 of 18


                                                                            Report No: CCISE190306902

5.5 Description of Support Units
     Manufacturer                 Description                 Model        Serial Number       FCC ID/DoC
        Skyworth                 Color LCD TV               24E12HR          K026709                SDOC
        Motorola                 Mobile phone                 Moto X           N/A                  SDOC

5.6 Related Submittal(s) / Grant (s)
       This is an original grant, no related submittals and grants.

5.7 Description of Cable Used
        Cable Type                     Description                Length        From                 To
   Detached USB Cable                    shielded                   1.0m         EUT              Adapter

5.8 Laboratory Facility
       The test facility is recognized, certified, or accredited by the following organizations:
        FCC - Registration No.: 727551
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by FCC
       (Federal Communications Commission). The Registration No. is 727551.
        IC - Registration No.: 10106A-1
       The 3m Semi-anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
       Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with
       Registration No.: 10106A-1.
        CNAS - Registration No.: CNAS L6048
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
       Requirements for the Competence of Testing and Calibration laboratories for the competence of testing.
       The Registration No. is CNAS L6048.
        A2LA - Registration No.: 4346.01
       This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
       17025:2005 General requirements for the competence of testing and calibration laboratories. The test
       scope can be found as below link: https://portal.a2la.org/scopepdf/4346-01.pdf

5.9 Laboratory Location
       Shenzhen Zhongjian Nanfang Testing Co., Ltd.
       Address: No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
       Bao’an District, Shenzhen, Guangdong, China
       Tel: +86-755-23118282, Fax: +86-755-23116366
       Email: info@ccis-cb.com, Website: http://www.ccis-cb.com




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                         Project No.: CCISE1903069
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                        Page 6 of 18


                                                                                  Report No: CCISE190306902

5.10 Test Instruments list
 Radiated Emission:
                                                                                           Cal. Date        Cal. Due date
    Test Equipment            Manufacturer             Model No.          Serial No.
                                                                                          (mm-dd-yy)         (mm-dd-yy)
        3m SAC                  SAEMC                  9m*6m*6m               966         07-22-2017         07-21-2020
     Loop Antenna            SCHWARZBECK              FMZB1519B             00044         03-16-2019         03-15-2020
   BiConiLog Antenna         SCHWARZBECK               VULB9163               497         03-16-2019         03-15-2020
     Horn Antenna            SCHWARZBECK              BBHA9120D               916         03-16-2019         03-15-2020
     Horn Antenna            SCHWARZBECK              BBHA9120D              1805         06-22-2017         06-21-2020
     Horn Antenna            SCHWARZBECK              BBHA 9170          BBHA9170582      11-21-2018         11-20-2019
   EMI Test Software             AUDIX                    E3                           Version: 6.110919b
     Pre-amplifier                 HP                   8447D            2944A09358       03-07-2019         03-06-2020
     Pre-amplifier                 CD                  PAP-1G18             11804         03-07-2019         03-06-2020
   Spectrum analyzer         Rohde & Schwarz            FSP30              101454         03-07-2019         03-06-2020
   Spectrum analyzer         Rohde & Schwarz            FSP40              100363         11-21-2018         11-20-2019
   EMI Test Receiver         Rohde & Schwarz           ESRP7                101070        03-07-2019         03-06-2020
        Cable                    ZDECL              Z108-NJ-NJ-81          1608458        03-07-2019         03-06-2020
        Cable                 MICRO-COAX              MFR64639             K10742-5       03-07-2019         03-06-2020
        Cable                   SUHNER              SUCOFLEX100           58193/4PE       03-07-2019         03-06-2020


 Conducted Emission:
                                                                                         Cal. Date          Cal. Due date
   Test Equipment             Manufacturer            Model No.           Serial No.
                                                                                        (mm-dd-yy)           (mm-dd-yy)
  EMI Test Receiver         Rohde & Schwarz             ESCI               101189       03-07-2019           03-06-2020
    Pulse Limiter           SCHWARZBECK              OSRAM 2306             9731        03-07-2019           03-06-2020
        LISN                    CHASE                 MN2050D               1447        03-19-2019           03-18-2020
        LISN                Rohde & Schwarz           ESH3-Z5            8438621/010    07-21-2018           07-20-2019
       Cable                      HP                   10503A                N/A        03-07-2019           03-06-2020
  EMI Test Software             AUDIX                    E3                          Version: 6.110919b




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                Project No.: CCISE1903069
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                  Page 7 of 18


                                                                              Report No: CCISE190306902

6      Test results and Measurement Data
6.1 Conducted Emission
       Test Requirement:                FCC Part 15 B Section 15.107
       Test Method:                     ANSI C63.4:2014
       Test Frequency Range:            150kHz to 30MHz
       Class / Severity:                Class B                  Class B
       Receiver setup:                  RBW=9kHz, VBW=30kHz
       Limit:                                                                        Limit (dBµV)
                                          Frequency range (MHz)
                                                                          Quasi-peak                Average
                                                 0.15-0.5                   66 to 56*               56 to 46*
                                                   0.5-5                       56                      46
                                                  0.5-30                       60                      50
                                        * Decreases with the logarithm of the frequency.
       Test setup:




       Test procedure                   1. The E.U.T and simulators are connected to the main power through a
                                           line impedance stabilization network(L.I.S.N.). The provide a
                                           50ohm/50uH coupling impedance for the measuring equipment.
                                        2. The peripheral devices are also connected to the main power through a
                                           LISN that provides a 50ohm/50uH coupling impedance with 50ohm
                                           termination. (Please refers to the block diagram of the test setup and
                                           photographs).
                                        3. Both sides of A.C. line are checked for maximum conducted
                                           interference. In order to find the maximum emission, the relative
                                           positions of equipment and all of the interface cables must be changed
                                           according to ANSI C63.4: 2014 on conducted measurement.
       Test Instruments:                Refer to section 5.10 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    Pass




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1903069
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 8 of 18


c c I s                                                                                   Report No: CCISE190306902

Measurement data:
 Product name:                Live Deck                              Product model:              Live Deck

 Test by:                     Mike                                Test mode:                     Full Load mode

 Test frequency:              150 kHz ~ 30 MHz                       Phase:                      Line

 Test voltage:                AC 120 V/60 Hz                         Environment:                Temp: 22.5°C          Huni: 55%


       80Level(dBuV)


       70
       sol!                                                                                              FCC PART
                                                                                                              PART15 8 Q P

       5o                                                                                                FCC PART15 B AV


       aol|


       20                              I\M\‘J’fbflv\f\"\/‘fWWMMMN
       10


                                                                 2                    5             10            20         30
            L2
            in
                 h




                                 in




                                                  as




                                                           Frequency (MHz)

                               Read       LISN         Cable                  Limit       Over
                      Freq    Level Factor              Loss    Level          Line    Limit Remark



        1            0.158    48.32       0.17         10.77    59.26         65.56    —6.30     QP
        2            0.158    34.80       0.17         10.77    45.74         55.56    —9.82     Average
        3            0.214    40.50       0.1§         10.76    S1.41         63.05   —11.64     QP
        4            0.219    28.83       0.15§        10.176   39.74         52.88   —13.14     Average
        5            0. 266   36. 32      0.14         10.75    47.21         61.25   —14.04     QP
        6            0.377    26.18       0.12         10.72    37.02         48.34   —11.32     Average
        7            0.38§    33.70       0.12         10.72    44.54         58.17   —13.63     QP
        8            0.486    27.95       0.12         10.76    38.83         46.23    —7.40     Average
        9            0.494    35.45       0.12         10.76    46.33         56.10    —9.77     QP
       10            0.538    25.17       0.12         10.76    36.05         46.00    —9.95     Average
       11            0.582    32.88       0.12         10.76    43.76         56.00   —12.24     QP
       12            0.585    24.24       0.12         10.76    35.12         46.00   —10.88     Average


 Notes:
 1. An initial pre—scan was performed on the line and neutral lines with peak detector.
 2.   Quasi—Peak and Average measurement were performed at the frequencies with maximized peak emission.
 3. _Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                       Project No.: CCISE1903069
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                        Page 9 of 18


c c I s                                                                               Report No: CCISE190306902


 Product name:                Live Deck                        Product model:                Live Deck

Test by:                      Mike                             Test mode:                    Full Load mode

Test frequency:               150 kHz ~ 30 MHz                 Phase:                        Neutral

Test voltage:                 AC 120 V/60 Hz                   Environment:                  Temp: 22.5°C       Huni: 55%


          3 Level (aBuy)

          70
          60 1                                                                                         FCC PART15 B OP

          50                                                                                           FCC PART1SB AV


          40

          30

          20

          10



      Trace: 5                                          Frequency (MHz)
                                     Read      LISN   Cable                 Linmnit       Over
                           Freq   Level Factor          Loss     Level       Line         Limit Remark

                    """MHz dBu¥y _ db — db dBu¥ dBu¥ _dB
                1      0. 158     49.30        0.98    10.77     61.05      65.56      —4.51      QP
                2      0. 158     36. 05       0.98    10.77     47.80      55.56      —7.76      Average
                3      0.219      41.77        0.93    10.76     53.46      62.88      —9.42      QP
                4      0.219      31.21        0.93    10.76     42.90      52.88      —9.98      Average
                5      0. 322     26.82        0.97    10.74     38.53      49.66     —11.13      Average
                6      0. 327     36.96        0.97    10.73     48.66      59.53     —10.87      QP
                T      0.377      26.16        0.97    10.72     37.85      48.34     —10.49      Average
                8      0.474      37.15        0.97    10.75     48.87      56.45      —1.58      QP
                9      0.481      29.87        0.97    10.75     41.59      46.32      —4.173     Average
               10      0. 582     34.58        0.97    10.76     46.31      56.00      —9.69      QP
               11      0.595      25.53        0.97    10.77     37.27      46.00      —8.73      Average
               12      0. 686     29.87        0.97    10.77     41.61      56.00     —14.39      QP


 Notes:
 1. An initial pre—scan was performed on the line and neutral lines with peak detector.
 2.    Quasi—Peak and Average measurement were performed at the frequencies with maximized peak emission.
 3. _Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                     Project No.: CCISE1903069
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                    Page 10 of 18


                                                                         Report No: CCISE190306902

6.2 Radiated Emission
        Test Requirement:             FCC Part 15 B Section 15.109
        Test Method:                  ANSI C63.4:2014
        Test Frequency Range:         30MHz to 25000MHz
        Test site:                    Measurement Distance: 3m (Semi-Anechoic Chamber)
        Receiver setup:                 Frequency       Detector        RBW      VBW           Remark
                                       30MHz-1GHz      Quasi-peak      120kHz   300kHz    Quasi-peak Value
                                                         Peak           1MHz     3MHz       Peak Value
                                       Above 1GHz
                                                         RMS            1MHz     3MHz      Average Value
        Limit:                               Frequency           Limit (dBuV/m @3m)          Remark
                                           30MHz-88MHz                    40.0           Quasi-peak Value
                                          88MHz-216MHz                    43.5           Quasi-peak Value
                                          216MHz-960MHz                   46.0           Quasi-peak Value
                                           960MHz-1GHz                    54.0           Quasi-peak Value
                                                                          54.0            Average Value
                                            Above 1GHz
                                                                          74.0             Peak Value
        Test setup:                   Below 1GHz




                                      Above 1GHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                     Project No.: CCISE1903069
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                    Page 11 of 18


                                                                               Report No: CCISE190306902


        Test Procedure:                 1. The EUT was placed on the top of a rotating table 0.8 meters above
                                           the ground at a 3 meter semi-anechoic camber. The table was rotated
                                           360 degrees to determine the position of the highest radiation.
                                        2. The EUT was set 3 meters away from the interference-receiving
                                           antenna, which was mounted on the top of a variable-height antenna
                                           tower.
                                        3. The antenna height is varied from one meter to four meters above the
                                           ground to determine the maximum value of the field strength. Both
                                           horizontal and vertical polarizations of the antenna are set to make the
                                           measurement.
                                        4. For each suspected emission, the EUT was arranged to its worst case
                                           and then the antenna was tuned to heights from 1 meter to 4 meters
                                           and the rotatable table was turned from 0 degrees to 360 degrees to
                                           find the maximum reading.
                                        5. The test-receiver system was set to Peak Detect Function and
                                           Specified Bandwidth with Maximum Hold Mode.
                                        6. If the emission level of the EUT in peak mode was 10dB lower than the
                                           limit specified, then testing could be stopped and the peak values of
                                           the EUT would be reported. Otherwise the emissions that did not have
                                           10dB margin would be re-tested one by one using peak, quasi-peak or
                                           average method as specified and then reported in a data sheet.
        Test Instruments:               Refer to section 5.10 for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Passed
        Remark:                         All of the observed value above 6GHz ware the niose floor , which were
                                        no recorded




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1903069
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 12 of 18


CCIS                                                                                   Report No: CCISE190306902

Measurement Data:
Below 1GHz:

 Product Name:              Live Deck                                 Product model:            Live Deck

Test By:                    Mike                                      Test mode:                Full Load mode

Test Frequency:             30 MHz ~1 GHz                             Polarization:             Vertical

Test Voltage:               AC 120V/60Hz                              Environment:              Temp: 24°C       Huni: 57%


      80Level (dBuVim)



      70


      60
                                                                                                   FCC PART1S CLAS$ B

      50

      40


      30


      20


      10


       030             50                     100                  200                             500                 1000
                                                         Frequency (MHz)

                              Readintenna            Cable Preamp                       Linit        Over
                   Freq      Level Factor              Loss Factor           Level       Line       Limit Remark

                 _NHz          dBu¥        dB/m           dB _ dB dBuV/m dBu¥/m                             db _
      1        45.855        46.96        13.77        1.28      29.85       G2.1T      40.00 —1.83 9P
      2       267.546        46.92        13.41        2.86      28.51       34.68      46.00 —11.32 QP
      3       446.414        53.19        16.06        3.19      28.86       43.58      46.00       —2.42 QP
      4       §95.133        41.29       19.09         3.94      28.95       35.37      46.00 —10.63 QP
      5       T4ad4.866      47.73       20.88         4.34      28.50       44.45      46.00 —1.55 qP
      6       893.857        46.22       22.18         3.77      27.89       44.28      46.00 —1.72 QP

 Remark:
 1. Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                     Project No.: CCISE1903069
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                      Page 13 of 18


CCIS                                                                                   Report No: CCISE190306902


 Product Name:               Live Deck                                Product model:             Live Deck

 Test By:                    Mike                                     Test mode:                 Full Load mode

 Test Frequency:             30 MHz ~ 1 GHz                           Polarization:              Horizontal

 Test Voltage:               AC 120V/60Hz                             Environment:               Temp: 24°C        Huni: 57%


      3 0Level (dBuVim)


      70

      60
                                                                                                   FCC PART1S CLASS$ B
      50

      40

      30

      20

      10


           30          50                    100                  200                              500                  1000
                                                        Frequency (MHz)
                               Readintenna           Cable Preamp                       Limit        Over
                    Freq      Level Factor             Loss Factor          Level        Line       Limit Remark

                     NHz        dBu¥       dB/n           dB _        dB dBu¥/m dBu¥/m —                    dB _           0
       1         31.731       51.99       11.00        0.85      29.97       33.87      40.00 —6.13 QP
       o        370.702       43.64       14.99        3.09      28.65       33.07      46.00 —12.93 QP
       3        446.414       53.52       16.06        3.19      28.86      43.91       46.00       —2.09 qP
       4        §95.133       48.80       19.09        3.94      28.95      42.88       46.00       —3.12 QP
       5        T44.866       48.12       20.88        4.34      28.50      44.84       46.00       —1.16 qP
       6        893.857       40.90       22.18        3.77      27.89      38.96       46.00       —7.04 QP

 Remark:
 1.    Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.    The emission levels of other frequencies are very lowerthan the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                     Project No.: CCISE1903069
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                        Page 14 of 18


c c I s                                                                                Report No: CCISE190306902

Above 1GHz:
 Product Name:              Live Deck                                 Product model:            Live Deck

 Test By:                   Mike                                      Test mode:                Full Load mode

 Test Frequency:            1 GHz ~ 6 GHz                             Polarization:             Vertical

 Test Voltage:              AC 120V/60Hz                              Environment:              Temp: 24°C         Huni: 57%


           Level (dBuVim)
      80
                                                                                                           FCC PART 15 (PK)
      70

      60
                                                                                                           FCC PART 15 (AV)
      50

      40


      30


      20


      10


       G1000      1200          1500              2000                                                          5000    6000
                                                         Frequency (MHz)
                               Readdntenna          Cable Preamp                       Linmit      Over
                     Freq     Level Factor            Loss Factor          Level         Line     Limit Remark

                      NHz      dBu¥        dB/m —         dB _       dB dBu¥/m dBu¥/m                   dB ~             _0
        1      2458.283       49.13      27.52        4.77      41.92      39.50       74.00     —34.50       Peak
       2        2458.283      41.24      27.52        4.77      41.92      31.61       54.00     —22.39       Average
       3        4111.131      47.77      30.41        6.27      41.81      42.64       74.00     —31.36       Peak
       40      4111.131       38.56      30.41        6.27      41.81      33.43       54.00     —20.57       Average
       §        4685.613      48.34      31.41        6.86      42.01      44.60       74.00     —29.40       Peak
       6        4685.613      39.52      31.41        6.86      42.01      35.78       54.00     —18.22       Average

 Remark:
 1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preampiifier Factor.
 2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                     Project No.: CCISE1903069
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                       Page 15 of 18


CCIS                                                                                   Report No: CCISE190306902


 Product Name:              Live Deck                                 Product model:            Live Deck

Test By:                    Mike                                      Test mode:                Full Load mode

Test Frequency:             1 GHz ~6 GHz                              Polarization:             Horizontal

Test Voltage:               AC 120V/60Hz                              Environment:              Temp: 24°C              Huni: 57%


      sol.evel (dBu\/m)
                                                                                                       FCC PART 15 (PK)
      70

      60
                                                                                                       FCC PART 15 (AV)
      50                                                                                                     &

      40

      30


      20

      10


           1000   1200         1500               2000                                                           5000       6000
                                                         Frequency (MHz)
                              Readdntenna           Cable Preamp                       Limit        Over
                   Freq      Level Factor             Loss Factor          Level         Line      Limit Remark

                    NHz        dBu¥       dB/m           dB _        dB dBu¥/m dBu¥/m —dB __
      1       2801.799       48.32       28.23        5.13      41.66      40.02       74.00     —33.98      Peak
      2       2801.T99       39.42       28.23        5.13      41.66      31.12       54.00     —22.88      Average
      3       3665.723       46.64       29.35        5.95      41.62      40.32       74.00     —33.68      Peak
      4       3665.723       37.63       29.35        5.95      41.62      31.31       54.00     —22.69      Average
      5       4761.785       47.98       31.53        6.82      41.88      44.45       74.00     —29.55      Peak
      6       4T761.T85      38.56       31.53        6.82      41.88      35.03       54.00     —18.97      Average

 Remark:
 1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                     Project No.: CCISE1903069
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                         Page 16 of 18



Document Created: 2019-04-09 11:09:05
Document Modified: 2019-04-09 11:09:05

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC