RF Exposure

FCC ID: 2AGNTEVORC582409A

RF Exposure Info

Download: PDF
FCCID_3763705

Bay Area Compliance Laboratories Corp. (Shenzhen)                                    Report No.: RSZ171110005-00A

FCC §15.247 (i) & §1.1307 (b) (1) & §2.1091- MAXIMUM PERMISSIBLE
EXPOSURE (MPE)
Applicable Standard
According to subpart 15.247 (i) and subpart 1.1307 (b)(1), 2.1091 systems operating under the provisions
of this section shall be operated in a manner that ensures the public is not exposed to RF energy level in
excess of the communication guidelines.

                                   Limits for General Population/Uncontrolled Exposure

                                  Limits for General Population/Uncontrolled Exposure
             Frequency              Electric Field     Magnetic Field        Power           Averaging
               Range                   Strength           Strength          Density            Time
               (MHz)                    (V/m)              (A/m)           (mW/cm2)          (Minutes)
              0.3-1.34                   614                  1.63         *(100)                 30
                                                                                     2
              1.34-30                   824/f                2.19/f       *(180/f )               30
                 30-300                  27.5                0.073             0.2                30
             300-1500                        /                 /           f/1500                 30
           1500-100,000                      /                 /               1.0                30

f = frequency in MHz
* = Plane-wave equivalent power density


Result
Calculated Formulary:

Predication of MPE limit at a given distance
                                                              PG
                                                        S=
                                                             4πR 2
S = power density (in appropriate units, e.g. mW/cm2)
P = power input to the antenna (in appropriate units, e.g., mW).
G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain
    factor, is normally numeric gain.
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)

    Frequency               Antenna Gain         Conducted Power       Evaluation          Power
                                                                                                       MPE Limit
      Range                                                             Distance          Density
                          (dBi)     (numeric)    (dBm)        (mW)                                     (mW/cm2)
      (MHz)                                                              (cm)            (mW/cm2)
  2407.5 - 2471.5          2          1.58         25         316.23       20              0.100           1.00
  2412.5 - 2462.5          2          1.58         24         251.19      20              0.079            1.00
     909 - 921             1          1.26         24         251.19      20              0.063            0.61
     914 - 916             1          1.26         25         316.23      20              0.079            0.61

Note: The conducted power is the tune-up power of the Max Conducted Peak Output Power.

To maintain compliance with the FCC’s RF exposure guidelines, place the equipment at least 20cm from
nearby persons.


FCC Part 15.247                                                                                     Page 16 of 109



Document Created: 2018-02-28 03:41:21
Document Modified: 2018-02-28 03:41:21

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC