Test Report

FCC ID: 2AGNTEVOA2400A

Test Report

Download: PDF
FCCID_4089919

Bay Area Compliance Laboratories Corp. (Shenzhen)                                  Report No.: RSZ180925002-00B

FCC §15.247 (i) & §1.1307 (b) (1) & §2.1091- MAXIMUM PERMISSIBLE
EXPOSURE (MPE)
Applicable Standard
According to subpart 15.247 (i) and subpart 1.1307 (b)(1), 2.1091 systems operating under the provisions
of this section shall be operated in a manner that ensures the public is not exposed to RF energy level in
excess of the communication guidelines.

                                 Limits for General Population/Uncontrolled Exposure

                                Limits for General Population/Uncontrolled Exposure
             Frequency            Electric Field     Magnetic Field        Power          Averaging
               Range                 Strength           Strength          Density           Time
               (MHz)                  (V/m)              (A/m)           (mW/cm2)         (Minutes)
              0.3-1.34                 614                   1.63        *(100)                 30
              1.34-30                 824/f                 2.19/f      *(180/f2)               30
               30-300                  27.5                 0.073            0.2                30
             300-1500                      /                  /          f/1500                 30
           1500-100,000                    /                  /              1.0                30

f = frequency in MHz
* = Plane-wave equivalent power density


Result
Calculated Formulary:
Predication of MPE limit at a given distance
                                                             PG
                                                       S=
                                                            4R 2
S = power density (in appropriate units, e.g. mW/cm2)
P = power input to the antenna (in appropriate units, e.g., mW).
G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain
    factor, is normally numeric gain.
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)

    Frequency             Antenna Gain         Tune-up Power         Evaluation        Power
                                                                                                     MPE Limit
      Range                                                           Distance        Density
                        (dBi)     (numeric)    (dBm)         (mW)                                    (mW/cm2)
      (MHz)                                                            (cm)          (mW/cm2)
  2407.5 - 2471.5        2.0        1.58        19.0         79.43       20            0.025            1.00
  2412.5 - 2462.5        2.0        1.58        18.5         70.79      20              0.022           1.00


To maintain compliance with the FCC’s RF exposure guidelines, place the equipment at least 20cm from
nearby persons.




FCC Part 15.247                                                                                  Page 16 of 78



Document Created: 2018-11-29 18:10:39
Document Modified: 2018-11-29 18:10:39