Test Report

FCC ID: 2AGNTAC5809A

Test Report

Download: PDF
FCCID_2883801

                                            FCC PART 15.407
                                               TEST REPORT
                                                               For

                                    Autel Robotics Co., Ltd.
           9th Floor, Bldg.B1, Zhiyuan, 1001 Xueyuan Rd., Xili, Nanshan, Shenzhen, China


                                       FCC ID: 2AGNTAC5809A


               Report Type:                                       Product Type:
               Original Report                                    X-Star series



                      Test Engineer:         Simon Wang


                    Report Number:           RSZ151118002-00A


                         Report Date:        2015-12-16

                                             Bell Hu

                        Reviewed By:         RF Engineer

                        Prepared By:         Bay Area Compliance Laboratories Corp. (Shenzhen)
                                             6/F, the 3rd Phase of WanLi Industrial Building
                                             ShiHua Road, FuTian Free Trade Zone
                                             Shenzhen, Guangdong, China
                                             Tel: +86-755-33320018
                                             Fax: +86-755-33320008
                                             www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp.


Bay Area Compliance Laboratories Corp. (Dongguan)                                                                          Report No.: RSZ151118002-00A




                                                       TABLE OF CONTENTS


GENERAL INFORMATION .......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 TEST FACILITY .............................................................................................................................................................3
SYSTEM TEST CONFIGURATION ..........................................................................................................................4
  DESCRIPTION OF TEST CONFIGURATION ......................................................................................................................4
  EUT EXERCISE SOFTWARE ..........................................................................................................................................4
  EQUIPMENT MODIFICATIONS .......................................................................................................................................4
  EXTERNAL I/O CABLE..................................................................................................................................................5
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................5
SUMMARY OF TEST RESULTS ...............................................................................................................................6

FCC §15.407 (f) & §2.1091 – MAXIMUM PERMISSIBLE EXPOSURE (MPE) ......................................................7
  APPLICABLE STANDARD ..............................................................................................................................................7
FCC §15.203 – ANTENNA REQUIREMENT ............................................................................................................8
  APPLICABLE STANDARD ..............................................................................................................................................8
  ANTENNA CONNECTOR CONSTRUCTION ......................................................................................................................8
FCC §15.205 & §15.209 & §15.407(B) (4),(6),(7) – UNDESIRABLE EMISSION ...................................................9
  APPLICABLE STANDARD ..............................................................................................................................................9
  MEASUREMENT UNCERTAINTY ....................................................................................................................................9
  EUT SETUP ..................................................................................................................................................................9
  EMI TEST RECEIVER & SPECTRUM ANALYZER SETUP ..............................................................................................10
  TEST PROCEDURE ......................................................................................................................................................10
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................11
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................11
  TEST RESULTS SUMMARY ..........................................................................................................................................12
  TEST DATA ................................................................................................................................................................12
FCC §15.407(a) (1) – 99% OCCUPIED & 6dB EMISSION BANDWIDTH .........................................................15
  APPLICABLE STANDARD ............................................................................................................................................15
  TEST PROCEDURE ......................................................................................................................................................15
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................15
  TEST DATA ................................................................................................................................................................16
FCC §15.407(a) (3) – CONDUCTED TRANSMITTER OUTPUT POWER .........................................................20
  APPLICABLE STANDARD ............................................................................................................................................20
  TEST PROCEDURE ......................................................................................................................................................20
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................20
  TEST DATA ................................................................................................................................................................21
FCC §15.407(a) (3) – POWER SPECTRAL DENSITY ...........................................................................................25
  APPLICABLE STANDARD ............................................................................................................................................25
  TEST PROCEDURE ......................................................................................................................................................25
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................25
  TEST DATA ................................................................................................................................................................26


FCC Part 15.407                                                                                                                                         Page 2 of 27


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RSZ151118002-00A

GENERAL INFORMATION
Product Description for Equipment under Test (EUT)
The Autel Robotics Co., Ltd.’s product, model number: X-Star Premium (FCC ID: 2AGNTAC5809A) or
the "EUT" in this report was an X-Star series, which was measured approximately: 31.5 cm (L) x16.7 cm
(W) x 20.0 cm (H), rated with input voltage: DC 14.8V Li-Po battery.

*All measurement and test data in this report was gathered from production sample serial number: 1507133
(Assigned by BACL, Shenzhen). The EUT supplied by the applicant was received on 2015-11-18.


Objective
This type approval report is prepared on behalf of Autel Robotics Co., Ltd. in accordance with Part 2-
Subpart J, Part 15-Subparts A, B and E of the Federal Communication Commissions rules.

The tests were performed in order to determine compliance with FCC Part 15, Subpart E, section 15.203,
15.205, 15.207, 15.209 and 15.407 rules.


Related Submittal(s)/Grant(s)
FCC Part 15.247 DTS submissions with FCC ID: 2AGNTAC5809A.
Part 15.407 NII submission with FCC ID: 2AGNTRC5809A.


Test Methodology
All measurements contained in this report were conducted with ANSI C63.10-2013, American National
Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices.

All emissions measurement was performed and Bay Area Compliance Laboratories Corp. (Shenzhen). The
radiated testing was performed at an antenna-to-EUT distance of 3 meters.

Measurement uncertainty with RF radiated emission is 5.91 dB for 30MHz-1GHz.and 4.92 dB for above
1GHz, 1.95dB for conducted measurement.


Test Facility

The test site used by Bay Area Compliance Laboratories Corp. (Shenzhen) to collect test data is located on
the 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen,
Guangdong, China.

Test site at Bay Area Compliance Laboratories Corp. (Shenzhen) has been fully described in reports
submitted to the Federal Communication Commission (FCC). The details of these reports have been
found to be in compliance with the requirements of Section 2.948 of the FCC Rules on October 31, 2013.
The facility also complies with the radiated and AC line conducted test site criteria set forth in ANSI
C63.4-2014.

The Federal Communications Commission has the reports on file and is listed under FCC Registration No.:
382179. The test site has been approved by the FCC for public use and is listed in the FCC Public Access
Link (PAL) database.


FCC Part 15.407                                                                                   Page 3 of 27


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RSZ151118002-00A

SYSTEM TEST CONFIGURATION
Description of Test Configuration
The system was configured for testing in an engineering mode, which was provided by manufacturer.

                           Frequency                 Frequency                 Frequency
              Channel                     Channel                  Channel
                             (MHz)                     (MHz)                     (MHz)
                  1           5727           26         5752          51          5777
                  2           5728           27         5753          52          5778
                  3           5729           28         5754          53          5779
                  4           5730           29         5755          54          5780
                  5           5731           30         5756          55          5781
                  6           5732           31         5757          56          5782
                   7          5733           32        5758           57          5783
                   8          5734           33        5759           58          5784
                   9          5735           34        5760           59          5785
                  10          5736           35        5761           60          5786
                  11          5737           36        5762           61          5787
                  12          5738           37        5763           62          5788
                  13          5739           38        5764           63          5789
                  14          5740           39        5765           64          5790
                  15          5741           40        5766           65          5791
                  16          5742           41        5767           66          5792
                  17          5743           42        5768           67          5793
                  18          5744           43        5769           68          5794
                  19          5745           44        5770           69          5795
                  20          5746           45        5771           70          5796
                  21          5747           46        5772           71          5797
                  22          5748           47        5773           72          5798
                  23          5749           48        5774           73          5799
                  24          5750           49        5775
                  25          5751           50        5776

EUT was tested with Channel 1, 34 and 73.

EUT Exercise Software
No exercise software was used.


Equipment Modifications
No modification was made to the EUT tested.




FCC Part 15.407                                                                          Page 4 of 27


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RSZ151118002-00A

External I/O Cable

                  Cable Description                   Length (m)   From/Port                      To

                           /                              /            /                          /


Block Diagram of Test Setup
Below 1GHz:




                                                                                      1.0 Meter
                                                  EUT




              Non-conductive table
              80 cm above Ground Plane

                                                 1.5 Meters



Above 1GHz:
                                                                                      1.0 Meter




                                                  EUT


                          Non-conductive table
                          150 cm above Ground Plane




                                                 1.5 Meters



FCC Part 15.407                                                                                       Page 5 of 27


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RSZ151118002-00A


SUMMARY OF TEST RESULTS


                  FCC Rules                          Description of Test               Result

           §15.407 (f), §2.1091          Maximum Permissible Exposure (MPE)          Compliance
                   §15.203                          Antenna Requirement              Compliance
        §15.407(b)(6) & §15.207(a)                  Conducted Emissions             Not Applicable
        FCC §15.205 & §15.209 &
                                                    Undesirable Emission             Compliance
           §15.407(b) (4),(6),(7)
              §15.407(b) (4)                             Band edge                   Compliance
           §15.407(a) (1),(5),(e)      99% Occupied & 6dB Emission Bandwidth         Compliance
              §15.407(a) (3)              Conducted Transmitter Output Power         Compliance
              §15.407 (a) (3)                   Power Spectral Density               Compliance

     Not Applicable: The EUT was powered by battery.




FCC Part 15.407                                                                             Page 6 of 27


Bay Area Compliance Laboratories Corp. (Dongguan)                                Report No.: RSZ151118002-00A

FCC §15.407 (f) & §2.1091 – MAXIMUM PERMISSIBLE EXPOSURE (MPE)
Applicable Standard
According to FCC §2.1091 and §1.1307(b) (1), systems operating under the provisions of this section shall
be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess
of the Commission’s guideline.

Limits for Maximum Permissible Exposure (MPE) (§1.1310, §2.1091)

                             (B) Limits for General Population/Uncontrolled Exposure

   Frequency Range       Electric Field        Magnetic Field         Power Density        Averaging Time
        (MHz)           Strength (V/m)         Strength (A/m)           (mW/cm2)             (minutes)

       0.3–1.34                 614                  1.63                 *(100)                 30
        1.34–30                 824/f               2.19/f              *(180/f²)                30
        30–300                  27.5                0.073                  0.2                   30
       300–1500                   /                   /                   f/1500                 30
     1500–100,000                 /                   /                    1.0                   30

f = frequency in MHz; * = Plane-wave equivalent power density;

According to §1.1310 and §2.1091 RF exposure is calculated.

Calculated Formulary:

Predication of MPE limit at a given distance
S = PG/4R² = power density (in appropriate units, e.g. mW/cm2);
P = power input to the antenna (in appropriate units, e.g., mW);
G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain
factor, is normally numeric gain;
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm);


Calculated Data:

                                            Max tune –up
                      Antenna Gain           Conducted       Evaluation
       Frequency                                                           Power Density     MPE Limit
                                               Power          Distance
         (MHz)                                                               (mW/cm2)        (mW/cm2)
                                                                (cm)
                     (dBi)     (numeric)   (dBm) (mW)

       5727-5799      2.5         1.78      16.00    39.8        20              0.0141          1.0

Note: To maintain compliance with the FCC’s RF exposure guidelines, place the equipment at least 20cm
      from nearby persons.

Result: Compliance




FCC Part 15.407                                                                                  Page 7 of 27


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RSZ151118002-00A

FCC §15.203 – ANTENNA REQUIREMENT
Applicable Standard
According to § 15.203, an intentional radiator shall be designed to ensure that no antenna other than that
furnished by the responsible party shall be used with the device. The use of a permanently attached
antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered
sufficient to comply with the provisions of this section. The manufacturer may design the unit so that a
broken antenna can be replaced by the user, but the user of a standard antenna jack or electrical connector
is prohibited. The structure and application of the EUT were analyzed to determine compliance with
section §15.203 of the rules. §15.203 state that the subject device must meet the following criteria:
a. Antenna must be permanently attached to the unit.
b. Antenna must use a unique type of connector to attach to the EUT.
Unit must be professionally installed, and installer shall be responsible for verifying that the correct
antenna is employed with the unit.
And according to FCC 47 CFR section 15.407 (a), if the transmitting antennas of directional gain greater
than 6dBi are used, the transmit power and power spectral density shall be reduced by the amount in dB
that the directional gain of the antenna exceeds 6 dBi.


Antenna Connector Construction
The EUT has an internal antenna arrangement, which was permanently attached and the antenna gain is
2.5 dBi, fulfill the requirement of this section. Please refer to the EUT photos.


Result: Compliance.




FCC Part 15.407                                                                               Page 8 of 27


Bay Area Compliance Laboratories Corp. (Dongguan)                            Report No.: RSZ151118002-00A

FCC §15.205 & §15.209 & §15.407(B) (4),(6),(7) – UNDESIRABLE EMISSION
Applicable Standard
FCC §15.407 (b) (4), (6), (7); §15.205; §15.209;

For transmitters operating in the 5.725–5.825 GHz band: all emissions within the frequency range from the
band edge to 10 MHz above or below the band edge shall not exceed an EIRP of –17 dBm/MHz; for
frequencies 10 MHz or greater above or below the band edge, emissions shall not exceed an EIRP of –27
dBm/MHz.

Unwanted emissions below 1 GHz must comply with the general field strength limits set forth in §15.209.


Measurement Uncertainty
All measurements involve certain levels of uncertainties, especially in field of EMC. The factors
contributing to uncertainties are spectrum analyzer, cable loss, antenna factor calibration, antenna
directivity, antenna factor variation with height, antenna phase center variation, antenna factor frequency
interpolation, measurement distance variation, site imperfections, mismatch (average), and system
repeatability.

Based on CISPR 16-4-2:2011, the expended combined standard uncertainty of radiation emissions at Bay
Area Compliance Laboratories Corp. (Shenzhen) is 5.91 dB for 30MHz-1GHz and 4.92 dB for above
1GHz, 1.95dB for conducted measurement at antenna port. And the uncertainty will not be taken into
consideration for the test data recorded in the report


EUT Setup
Below 1GHz:




FCC Part 15.407                                                                                Page 9 of 27


Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: RSZ151118002-00A

Above 1GHz:




The setup of EUT is according with per ANSI C63.10-2013 measurement procedure. The specification
used was with the FCC Part 15.209 limits.

The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the
middle.


EMI Test Receiver & Spectrum Analyzer Setup
The system was investigated from 30 MHz to 40 GHz.

During the radiated emission test, the EMI test receiver & Spectrum Analyzer Setup were set with the
following configurations:

          Frequency Range            RBW            Video B/W          IF B/W           Detector
         30 MHz – 1000 MHz          100 kHz           300 kHz          120 kHz             QP
                                     1 MHz            3 MHz               /                PK
            Above 1 GHz
                                     1 MHz             10 Hz              /               Ave.


Test Procedure
Radiated Spurious Emission

During the radiated emission test, the adapter was connected to the AC floor outlet.
Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
the installation combinations.

Data was recorded in Quasi-peak detection mode for frequency range of 30 MHz-40GHz, peak and
Average detection modes for frequencies above 1GHz.

The EUT is set 3.0 meter away from the testing antenna, which is varied from 1-4 meters, and the EUT is
placed on a turntable, the table shall be rotated for 360 degrees to find out the highest emission. The
receiving antenna should be changed the polarization both of horizontal and vertical.

FCC Part 15.407                                                                                  Page 10 of 27


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RSZ151118002-00A

Conducted Spurious Emission at Antenna Port
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
2. The Resolution bandwidth is set to 1MHz, The Video bandwidth is set to ≥ 1MHz, report the peak
   value out of the oprating band.
3. Repeat above procedures until all frequencies measured were complete.


                          EUT                                 Signal Analyzer




Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:
        Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain
The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:
        Margin = Limit – Corrected Amplitude

Test Equipment List and Details

                                                                     Serial        Calibration    Calibration
   Manufacturer             Description             Model
                                                                    Number            Date         Due Date
         HP                 Amplifier            HP8447E          1937A01046       2015-05-06      2016-05-06
  Rohde & Schwarz       EMI Test Receiver          ESCI              101120        2015-11-03      2016-11-03
   Sunol Sciences        Bi-log Antenna             JB1            A040904-2       2014-12-07      2017-12-06
        Mini                Amplifier          ZVA-183-S+         5969001149       2015-04-23      2016-04-23
    A.H. System           Horn Antenna         SAS-200/571            135          2015-08-18      2018-08-17
  Rohde & Schwarz        Signal Analyzer         FSIQ26           8386001028       2015-12-11      2016-12-11
                                                  ALN-
   DUCOMMUN               Pre-amplifier                            991373-01       2015-08-03      2016-08-03
                                               22093530-01
      Agilent           Spectrum Analyzer         8564E           3943A01781       2013-05-09      2016-05-08
    the electro-
                          Horn Antenna             3116            9510-2270       2013-10-14      2016-10-13
   Mechanics Co.

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have
been performed in accordance to requirements that traceable to National Primary Standards and International System
of Units (SI).




FCC Part 15.407                                                                                    Page 11 of 27


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RSZ151118002-00A

Test Results Summary
According to the recorded data in following table, the EUT complied with the FCC Title 47, Part 15,
Subpart C, Section 15.205, 15.209 and 15.407, the worst margin reading as below:

                  0.32 dB at 5724.75 MHz in the Vertical polarization for Left Side Band.


Refer to CISPR16-4-2:2011 and CISPR 16-4-1:2009, the measured level is in compliance with the limit if

                                            Lm + U(Lm) ≤ Llim + Ucispr

In BACL, U(Lm) is less than Ucispr, if Lm is less than Llim, it implies that the EUT complies with the limit.


Test Data

     Environmental Conditions

               Temperature:                26 ℃
          Relative Humidity:               53 %
              ATM Pressure:              101.0 kPa

    The testing was performed by Simon Wang on 2015-12-12.

    EUT operation mode: Transmitting




FCC Part 15.407                                                                                    Page 12 of 27


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RSZ151118002-00A


30 MHz-40 GHz:

   Frequency           Receiver     Turntable Rx Antenna Corrected Corrected   FCC Part 15.407
                  Reading Detector           Height Polar Factor   Amplitude  Limit    Margin
     (MHz)                           Degree                 dB     (dBμV/m) (dBμV/m)
                  (dBμV) (PK/QP/AV)           (m) (H / V)                                (dB)
                                       Low Channel (5727 MHz)
      256.8        44.15      QP         201       1.2     H      -13.9   30.25      46       15.75
     5727.00       62.16      PK         301       2.0     H      42.48   104.64     /          /
     5727.00       48.78     Ave.        301       2.0     H      42.48   91.26      /          /
     5727.00       65.37      PK          89       1.3     V      42.48   107.85     /          /
     5727.00       51.29     Ave.         89       1.3     V      42.48   93.77      /          /
    11454.00       35.08      PK         320       2.3     H      27.36   62.44      74       11.56
    11454.00       18.34     Ave.        320       2.3     H      27.36   45.70      54        8.30
    11454.00       32.19      PK         101       1.7     V      27.36   59.55      74       14.45
    11454.00       17.45     Ave.        101       1.7     V      27.36   44.81      54        9.19
                                         Middle Channel (5760 MHz)
      256.8        44.52      QP         201       1.2     H      -13.9   30.62      46       15.38
     5760.00       67.95      PK          71       1.1     H      42.39   110.34     /          /
     5760.00       53.71     Ave.         71       1.1     H      42.39   96.10      /          /
     5760.00       73.06      PK         179       2.3     V      42.39   115.45     /          /
     5760.00       59.54     Ave.        179       2.3     V      42.39   101.93     /          /
    11520.00       33.72      PK          50       1.6     H      27.36   61.08      74       12.92
    11520.00       17.00     Ave.         50       1.6     H      27.36   44.36      54        9.64
    11520.00       37.21      PK         234       1.9     V      27.36   64.57      74        9.43
    11520.00       20.52     Ave.        234       1.9     V      27.36   47.88      54        6.12
                                          High Channel (5799 MHz)
      256.8        44.44      QP         201       1.2     H      -13.9   30.54      46       15.46
     5799.00       61.87      PK          75       2.1     H      42.39   104.26     /          /
     5799.00       48.24     Ave.         75       2.1     H      42.39   90.63      /          /
     5799.00       62.81      PK         304       1.7     V      42.39   105.20     /          /
     5799.00       48.78     Ave.        304       1.7     V      42.39   91.17      /          /
    11598.00       32.61      PK          50       1.8     H      28.49   61.10      74       12.90
    11598.00       17.11     Ave.         50       1.8     H      28.49   45.60      54        8.40
    11598.00       34.53      PK          92       1.9     V      28.49   63.02      74       10.98
    11598.00       18.35     Ave.         92       1.9     V      28.49   46.84      54        7.16

Note:
Corrected Amplitude = Corrected Factor + Reading
Corrected Factor=Antenna factor (RX) + Cable Loss – Amplifier Factor
Margin = Limit- Corr. Amplitude




FCC Part 15.407                                                                            Page 13 of 27


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RSZ151118002-00A


 BAND EDGE:

   Frequency           Receiver     Turntable Rx Antenna Corrected Corrected   FCC Part 15.407
                  Reading Detector           Height Polar Factor Amplitude Limit       Margin
     (MHz)                           Degree                 dB     (dBμV/m) (dBμV/m)
                  (dBμV) (PK/QP/AV)           (m) (H / V)                                (dB)
                                            Left Side Band
     5724.75       45.12      PK          125       1.7    H      15.54   60.66     74       13.34
     5724.75       37.71     Ave.         125       1.7    H      15.54   53.25     54        0.75
     5724.75       46.53      PK          89        1.5    V      15.54   62.07     74       11.93
     5724.75       38.14     Ave.         89        1.5    V      15.54   53.68     54        0.32
                                                Right Side Band
     5856.37       30.45      PK          177       1.7    H      15.23   45.68     74       28.32
     5856.37       25.86     Ave.         177       1.7    H      15.23   41.09     54       12.91
     5856.37       31.52      PK          204       1.5    V      15.23   46.75     74       27.25
     5856.37       26.37     Ave.         204       1.5    V      15.23   41.6      54       12.40

Note:
Corrected Amplitude = Corrected Factor + Reading
Corrected Factor=Antenna factor (RX) + Cable Loss – Amplifier Factor
Margin = Limit- Corr. Amplitude




FCC Part 15.407                                                                           Page 14 of 27


Bay Area Compliance Laboratories Corp. (Dongguan)                                Report No.: RSZ151118002-00A

FCC §15.407(a) (1) – 99% OCCUPIED & 6dB EMISSION BANDWIDTH
Applicable Standard
The maximum power spectral density is measured as a conducted emission by direct connection of a
calibrated test instrument to the equipment under test. If the device cannot be connected directly,
alternative techniques acceptable to the Commission may be used. Measurements in the 5.725-5.85 GHz
band are made over a reference bandwidth of 500 kHz or the 26 dB emission bandwidth of the device,
whichever is less. Measurements in the 5.15-5.25 GHz, 5.25-5.35 GHz, and the 5.47-5.725 GHz bands are
made over a bandwidth of 1 MHz or the 26 dB emission bandwidth of the device, whichever is less. A
narrower resolution bandwidth can be used, provided that the measured power is integrated over the full
reference bandwidth.

Within the 5.725-5.85 GHz band, the minimum 6 dB bandwidth of U-NII devices shall be at least 500 kHz.


Test Procedure

1. Emission Bandwidth (EBW)
a) Set RBW = approximately 1% of the emission bandwidth.
b) Set the VBW > RBW.
c) Detector = Peak.
d) Trace mode = max hold.
e) Measure the maximum width of the emission that is 26 dB down from the maximum of the emission.
Compare this with the RBW setting of the analyzer. Readjust RBW and repeat measurement as needed
until the RBW/EBW ratio is approximately 1%.

2. Minimum Emission Bandwidth for the band 5.725-5.85 GHz
Section 15.407(e) specifies the minimum 6 dB emission bandwidth of at least 500 KHz for the band 5.715-
5.85 GHz. The following procedure shall be used for measuring this bandwidth:
a) Set RBW = 100 kHz.
b) Set the video bandwidth (VBW) ≥ 3 × RBW.
c) Detector = Peak.
d) Trace mode = max hold.
e) Sweep = auto couple.
f) Allow the trace to stabilize.
g) Measure the maximum width of the emission that is constrained by the frequencies associated with the
two outermost amplitude points (upper and lower frequencies) that are attenuated by 6 dB relative to the
maximum level measured in the fundamental emission.

                                                                    Signal Analyzer
                               EUT


Test Equipment List and Details

                                                                       Serial         Calibration   Calibration
    Manufacturer            Description             Model
                                                                      Number             Date        Due Date
  Rohde & Schwarz         Signal Analyzer           FSIQ26          8386001028        2015-12-11    2016-12-11

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have
been performed in accordance to requirements, traceable to National Primary Standards and International System of
Units (SI).

FCC Part 15.407                                                                                     Page 15 of 27


Bay Area Compliance Laboratories Corp. (Dongguan)                                                  Report No.: RSZ151118002-00A

Test Data
     Environmental Conditions

               Temperature:                    26 ℃
        Relative Humidity:                     51 %
            ATM Pressure:                    101.0 kPa

    The testing was performed by Simon Wang on 2015-12-12 and 2015-12-22.

    EUT operation mode: Transmitting

    Test Result: Pass

    Please refer to the following tables and plots.

                                                      Occupied
                          Frequency                                                 6dB Bandwidth                      Limit
      Channel                                         Bandwidth
                            (MHz)                                                       (MHz)                          (kHz)
                                                        (MHz)
        Low                  5727                            1.703                         1.072                       ≥500
      Middle                 5760                            1.874                         1.152                       ≥500
       High                  5799                            1.804                         1.112                       ≥500


                                      6dB Emission Bandwidth, Low Channel
                                          Delta 1 [T1]                 RBW       100 kHz     RF Att     30 dB
                          Ref Lvl                        1.00 dB       VBW       300 kHz
                          24 dBm                1.07214429 MHz         SWT         5 ms      Unit          dBm
                     24
                            4 dB Offset                                             1 [T1]            9.12 dBm
                     20                                                                                           A
                                                                                              5.72643387 GHz
                           D1 15.57 dBm
                                                         1                   1      1 [T1]            1.00 dB
                     10        D2 9.57 dBm                                                    1.07214429 MHz


                      0



                    -10 1MAX                                                                                     1MA



                    -20



                    -30



                    -40



                    -50



                    -60



                    -70

                    -76
                          Center 5.727 GHz                      500 kHz/                            Span 5 MHz

                  Date:          12.DEC.2015   14:11:34




FCC Part 15.407                                                                                                          Page 16 of 27


Bay Area Compliance Laboratories Corp. (Dongguan)                                            Report No.: RSZ151118002-00A

                                    6dB Emission Bandwidth, Middle Channel
                                         Delta 1 [T1]               RBW       100 kHz     RF Att     30 dB
                         Ref Lvl                        0.86 dB     VBW       300 kHz
                          24 dBm               1.15230461 MHz       SWT         5 ms      Unit          dBm
                    24
                           4 dB Offset                                           1 [T1]            9.23 dBm
                    20                                                                                         A
                          D1 16.06 dBm                                                     5.75935371 GHz

                                                    1                     1      1 [T1]            0.86 dB
                    10        D2 10.06 dBm
                                                                                           1.15230461 MHz


                     0



                   -10 1MAX                                                                                   1MA



                   -20



                   -30



                   -40



                   -50



                   -60



                   -70

                   -76
                         Center 5.76 GHz                     500 kHz/                            Span 5 MHz

                  Date:         12.DEC.2015   14:59:05




                                     6dB Emission Bandwidth, High Channel
                                         Delta 1 [T1]               RBW       100 kHz     RF Att     30 dB
                         Ref Lvl                        0.38 dB     VBW       300 kHz
                          24 dBm               1.11222445 MHz       SWT         5 ms      Unit          dBm
                    24
                           4 dB Offset                                           1 [T1]            9.24 dBm
                    20                                                                                         A
                                                                                           5.79839379 GHz
                          D1 15.37 dBm
                                                     1                    1      1 [T1]            0.38 dB
                    10        D2 9.37 dBm                                                  1.11222445 MHz


                     0



                   -10 1MAX                                                                                   1MA



                   -20



                   -30



                   -40



                   -50



                   -60



                   -70

                   -76
                         Center 5.799 GHz                    500 kHz/                            Span 5 MHz

                  Date:         12.DEC.2015   14:46:17




FCC Part 15.407                                                                                                     Page 17 of 27


Bay Area Compliance Laboratories Corp. (Dongguan)                                       Report No.: RSZ151118002-00A

                                      99% Occupied Bandwidth, Low Channel
                                         Marker 1 [T1]            RBW   30 kHz       RF Att      30 dB
                          Ref Lvl                     14.47 dBm   VBW   100 kHz
                          29.5 dBm              5.72697495 GHz    SWT   14 ms        Unit           dBm
                  29.5
                            10.5 dB Offset                                 1 [T1]             14.47 dBm
                                                                                                           A
                                                                                      5.72697495 GHz
                    20
                                                                          OPB         1.70340681 MHz
                                                              1
                                                                           T1 [T1]            -8.90 dBm
                    10                                                                5.72613327 GHz
                                                                           T2 [T1]            -9.06 dBm
                                                                                      5.72783667 GHz
                     0
                          1MAX                                                                            1MA
                                                 T1                      T2
                   -10



                   -20



                   -30



                   -40



                   -50



                   -60



                  -70.5
                          Center 5.727 GHz                 500 kHz/                         Span 5 MHz

                  Date:          22.DEC.2015   15:21:33




                                     99% Occupied Bandwidth, Middle Channel
                                         Marker 1 [T1]            RBW   30 kHz       RF Att      30 dB
                          Ref Lvl                     15.26 dBm   VBW   100 kHz
                          29.5 dBm              5.75994489 GHz    SWT   14 ms        Unit           dBm
                  29.5
                            10.5 dB Offset                                 1 [T1]             15.26 dBm
                                                                                                           A
                                                                                      5.75994489 GHz
                    20
                                                              1           OPB         1.87374749 MHz
                                                                           T1 [T1]            -6.94 dBm
                    10                                                                5.75903307 GHz
                                                                           T2 [T1]            -7.70 dBm
                                                                                      5.76090681 GHz
                     0
                          1MAX                  T1                        T2                              1MA

                   -10



                   -20



                   -30



                   -40



                   -50



                   -60



                  -70.5
                          Center 5.76 GHz                  500 kHz/                         Span 5 MHz

                  Date:          22.DEC.2015   16:29:39




FCC Part 15.407                                                                                                 Page 18 of 27


Bay Area Compliance Laboratories Corp. (Dongguan)                                      Report No.: RSZ151118002-00A


                                     99% Occupied Bandwidth, High Channel
                                         Marker 1 [T1]           RBW   30 kHz       RF Att      30 dB
                          Ref Lvl                    14.56 dBm   VBW   100 kHz
                          29.5 dBm              5.79895491 GHz   SWT   14 ms        Unit           dBm
                  29.5
                            10.5 dB Offset                                1 [T1]             14.56 dBm
                                                                                                          A
                                                                                     5.79895491 GHz
                    20
                                                             1           OPB         1.80360721 MHz
                                                                          T1 [T1]            -7.10 dBm
                    10                                                               5.79806313 GHz
                                                                          T2 [T1]            -7.73 dBm
                                                                                     5.79986673 GHz
                     0
                          1MAX                  T1                       T2                              1MA

                   -10



                   -20



                   -30



                   -40



                   -50



                   -60



                  -70.5
                          Center 5.799 GHz                500 kHz/                         Span 5 MHz

                  Date:          22.DEC.2015   16:24:43




FCC Part 15.407                                                                                                Page 19 of 27


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RSZ151118002-00A


FCC §15.407(a) (3) – CONDUCTED TRANSMITTER OUTPUT POWER
Applicable Standard
For the band 5.725-5.85 GHz, the maximum conducted output power over the frequency band of operation
shall not exceed 1 W. In addition, the maximum power spectral density shall not exceed 30 dBm in any
500-kHz band. If transmitting antennas of directional gain greater than 6 dBi are used, both the maximum
conducted output power and the maximum power spectral density shall be reduced by the amount in dB
that the directional gain of the antenna exceeds 6 dBi. However, fixed point-to-point U-NII devices
operating in this band may employ transmitting antennas with directional gain greater than 6 dBi without
any corresponding reduction in transmitter conducted power. Fixed, point-to-point operations exclude the
use of point-to-multipoint systems, omnidirectional applications, and multiple collocated transmitters
transmitting the same information. The operator of the U-NII device, or if the equipment is professionally
installed, the installer, is responsible for ensuring that systems employing high gain directional antennas
are used exclusively for fixed, point-to-point operations.


Test Procedure
Set span to encompass the entire EBW (or, alternatively, the entire 99% occupied bandwidth) of the signal.
(ii) Set RBW = 1 MHz.
(iii) Set VBW ≥ 3 MHz.
(iv) Number of points in sweep ≥ 2 Span / RBW. (This ensures that bin-to-bin spacing is ≤ RBW/2, so that
narrowband signals are not lost between frequency bins.)
(v) Manually set sweep time ≥ 10 * (number of points in sweep) * (symbol period of the transmitted
signal), but not less than the automatic default sweep time.
(vi) Set detector = RMS.
(vii) The EUT shall be operated at 100 percent duty cycle.
(viii) Perform a single sweep.
(ix) Compute power by integrating the spectrum across the EBW (or, alternatively, the entire 99%
occupied bandwidth) of the signal using the instrument’s band power measurement function with band
limits set equal to the EBW (or occupied bandwidth) band edges. If the instrument does not have a band
power function, sum the spectrum levels (in power units) at 1 MHz intervals extending across the EBW (or,
alternatively, the entire 99% occupied bandwidth) of the spectrum.


Test Equipment List and Details

                                                                     Serial        Calibration     Calibration
     Manufacturer           Description            Model
                                                                    Number            Date          Due Date
   Rohde & Schwarz         Signal Analyzer         FSIQ26         8386001028        2015-12-11      2016-12-11

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have
 been performed in accordance to requirements, traceable to National Primary Standards and International System of
 Units (SI).




FCC Part 15.407                                                                                     Page 20 of 27


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RSZ151118002-00A

Test Data
     Environmental Conditions

             Temperature:               23 ℃
        Relative Humidity:               50 %
            ATM Pressure:              101.0 kPa

    The testing was performed by Simon Wang on 2015-12-12.

    EUT operation mode: Transmitting

    Test Result: Pass

                                                                 Max Conducted
                                              Max Conducted
                          Frequency                              Average Output       Limit
         Channel                             Peak Output Power
                            (MHz)                                    Power            (dBm)
                                                   (dBm)
                                                                     (dBm)
            Low              5727                   16.24            15.47             30
          Middle             5760                   16.22            15.81             30
            High             5799                   15.42            15.08             30




FCC Part 15.407                                                                        Page 21 of 27


Bay Area Compliance Laboratories Corp. (Dongguan)                                      Report No.: RSZ151118002-00A

                                    Peak Conducted Output Power, Low Channel
                                         Marker 1 [T1]              RBW   3 MHz     RF Att      30 dB
                         Ref Lvl                   16.24 dBm        VBW   3 MHz
                          24 dBm               5.72656914 GHz       SWT   5 ms      Unit           dBm
                    24
                           4 dB Offset                                     1 [T1]            16.24 dBm
                    20                                                                                    A
                                                          1
                                                                                     5.72656914 GHz

                    10



                     0



                   -10 1MAX                                                                              1MA



                   -20



                   -30



                   -40



                   -50



                   -60



                   -70

                   -76
                         Center 5.727 GHz                 1 MHz/                           Span 10 MHz

                  Date:        12.DEC.2015   14:03:25




                                   Peak Conducted Output Power, Middle Channel
                                         Marker 1 [T1]              RBW   3 MHz     RF Att      30 dB
                         Ref Lvl                   16.22 dBm        VBW   3 MHz
                          24 dBm               5.76033066 GHz       SWT   5 ms      Unit           dBm
                    24
                           4 dB Offset                                     1 [T1]            16.22 dBm
                    20                                                                                    A
                                                                1
                                                                                     5.76033066 GHz

                    10



                     0



                   -10 1MAX                                                                              1MA



                   -20



                   -30



                   -40



                   -50



                   -60



                   -70

                   -76
                         Center 5.76 GHz                  1 MHz/                           Span 10 MHz

                  Date:        12.DEC.2015   14:53:01



FCC Part 15.407                                                                                                Page 22 of 27


Bay Area Compliance Laboratories Corp. (Dongguan)                                            Report No.: RSZ151118002-00A

                                   Peak Conducted Output Power, High Channel
                                         Marker 1 [T1]                RBW   3 MHz     RF Att      30 dB
                         Ref Lvl                    15.42 dBm         VBW   3 MHz
                          24 dBm               5.79844890 GHz         SWT   5 ms      Unit           dBm
                    24
                           4 dB Offset                                       1 [T1]            15.42 dBm
                    20                                                                                      A
                                                         1
                                                                                       5.79844890 GHz

                    10



                     0



                   -10 1MAX                                                                                1MA



                   -20



                   -30



                   -40



                   -50



                   -60



                   -70

                   -76
                         Center 5.799 GHz                    1 MHz/                          Span 10 MHz

                  Date:        12.DEC.2015   14:41:30




                               Average Conducted Output Power, Low Channel
                                         Marker 1 [T1]                RBW   3 MHz     RF Att      30 dB
                         Ref Lvl                   15.47 dBm          VBW   3 MHz
                          24 dBm               5.72690982 GHz         SWT   5 ms      Unit           dBm
                    24
                           4 dB Offset                                       1 [T1]            15.47 dBm
                    20                                                                                      A
                                                              1
                                                                                       5.72690982 GHz

                    10



                     0



                   -10 1MAX                                                                                1RM



                   -20



                   -30



                   -40



                   -50



                   -60



                   -70

                   -76
                         Center 5.727 GHz                    1 MHz/                          Span 10 MHz

                  Date:        12.DEC.2015   14:04:07



FCC Part 15.407                                                                                                  Page 23 of 27


Bay Area Compliance Laboratories Corp. (Dongguan)                                            Report No.: RSZ151118002-00A

                              Average Conducted Output Power, Middle Channel
                                         Marker 1 [T1]                RBW   3 MHz     RF Att      30 dB
                         Ref Lvl                    15.81 dBm         VBW   3 MHz
                          24 dBm               5.75948898 GHz         SWT   5 ms      Unit           dBm
                    24
                           4 dB Offset                                       1 [T1]            15.81 dBm
                    20                                                                                      A
                                                         1
                                                                                       5.75948898 GHz

                    10



                     0



                   -10 1MAX                                                                                1RM



                   -20



                   -30



                   -40



                   -50



                   -60



                   -70

                   -76
                         Center 5.76 GHz                     1 MHz/                          Span 10 MHz

                  Date:        12.DEC.2015   14:53:34




                               Average Conducted Output Power, High Channel
                                         Marker 1 [T1]                RBW   3 MHz     RF Att      30 dB
                         Ref Lvl                   15.08 dBm          VBW   3 MHz
                          24 dBm               5.79856914 GHz         SWT   5 ms      Unit           dBm
                    24
                           4 dB Offset                                       1 [T1]            15.08 dBm
                    20                                                                                      A
                                                          1                            5.79856914 GHz

                    10



                     0



                   -10 1MAX                                                                                1RM



                   -20



                   -30



                   -40



                   -50



                   -60



                   -70

                   -76
                         Center 5.799 GHz                    1 MHz/                          Span 10 MHz

                  Date:        12.DEC.2015   14:42:00



FCC Part 15.407                                                                                                  Page 24 of 27


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RSZ151118002-00A


FCC §15.407(a) (3) – POWER SPECTRAL DENSITY
Applicable Standard
For the band 5.725-5.85 GHz, the maximum conducted output power over the frequency band of operation
shall not exceed 1 W. In addition, the maximum power spectral density shall not exceed 30 dBm in any
500-kHz band. If transmitting antennas of directional gain greater than 6 dBi are used, both the maximum
conducted output power and the maximum power spectral density shall be reduced by the amount in dB
that the directional gain of the antenna exceeds 6 dBi. However, fixed point-to-point U-NII devices
operating in this band may employ transmitting antennas with directional gain greater than 6 dBi without
any corresponding reduction in transmitter conducted power. Fixed, point-to-point operations exclude the
use of point-to-multipoint systems, omnidirectional applications, and multiple collocated transmitters
transmitting the same information. The operator of the U-NII device, or if the equipment is professionally
installed, the installer, is responsible for ensuring that systems employing high gain directional antennas
are used exclusively for fixed, point-to-point operations.

Test Procedure
For devices operating in the bands 5.15-5.25 GHz, 5.25-5.35 GHz, and 5.47-5.725 GHz, the
above procedures make use of 1 MHz RBW to satisfy directly the 1 MHz reference bandwidth
specified in § 15.407(a)(5). For devices operating in the band 5.725-5.85 GHz, the rules specify a
measurement bandwidth of 500 kHz. Many spectrum analyzers do not have 500 kHz RBW, thus
a narrower RBW may need to be used. The rules permit the use of a RBWs less than 1 MHz, or
500 kHz, “provided that the measured power is integrated over the full reference bandwidth” to
show the total power over the specified measurement bandwidth (i.e., 1 MHz, or 500 kHz). If
measurements are performed using a reduced resolution bandwidth (< 1 MHz, or < 500 kHz) and
integrated over 1 MHz, or 500 KHz bandwidth, the following adjustments to the procedures
apply:
a) Set RBW       1/T, where T is defined in section II.B.l.a).
b) Set VBW 3 RBW.
c) If measurement bandwidth of Maximum PSD is specified in 500 kHz, add
10log(500kHz/RBW) to the measured result, whereas RBW (< 500 KHz) is the reduced
resolution bandwidth of the spectrum analyzer set during measurement.
d) If measurement bandwidth of Maximum PSD is specified in 1 MHz, add 10log(1MHz/RBW)
to the measured result, whereas RBW (< 1 MHz) is the reduced resolution bandwidth of
spectrum analyzer set during measurement.
e) Care must be taken to ensure that the measurements are performed during a period of
continuous transmission or are corrected upward for duty cycle.
Note: As a practical matter, it is recommended to use reduced RBW of 100 KHz for the sections
5.c) and 5.d) above, since RBW=100 KHZ is available on nearly all spectrum analyzers.

Test Equipment List and Details

                                                                     Serial        Calibration     Calibration
    Manufacturer           Description             Model
                                                                    Number            Date          Due Date
  Rohde & Schwarz         Signal Analyzer         FSIQ26          8386001028        2015-12-11      2016-12-11

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have
been performed in accordance to requirements, traceable to National Primary Standards and International System of
Units (SI).




FCC Part 15.407                                                                                     Page 25 of 27


Bay Area Compliance Laboratories Corp. (Dongguan)                                               Report No.: RSZ151118002-00A

Test Data
     Environmental Conditions

              Temperature:                      26 ℃
        Relative Humidity:                      51 %
            ATM Pressure:                     101.0 kPa

     The testing was performed by Simon Wang from 2015-12-22.

    EUT operation mode: Transmitting

    Test Result: Pass

    Please refer to the following tables and plots.

                                           Frequency                          PSD                             Limit
            Channel
                                                (MHz)                     (dBm/500kHz)                (dBm/500kHz)
               Low                              5727                          14.09                                 30
              Middle                            5760                          15.65                                 30
               High                             5799                          15.50                                 30


                                        Power Spectral Density, Low Channel
                                          Marker 1 [T1]               RBW    500 kHz     RF Att      30 dB
                           Ref Lvl                     14.09 dBm      VBW     2 MHz
                            29.5 dBm             5.72653407 GHz       SWT     5 ms       Unit           dBm
                   29.5
                             10.5 dB Offset                                     1 [T1]            14.09 dBm
                                                                                                               A
                                                                                          5.72653407 GHz
                      20
                                                           1

                      10



                       0
                           1MAX                                                                               1RM

                    -10



                    -20



                    -30



                    -40



                    -50



                    -60



                  -70.5
                           Center 5.727 GHz                    500 kHz/                          Span 5 MHz

                  Date:           22.DEC.2015   16:18:25




FCC Part 15.407                                                                                                          Page 26 of 27


Bay Area Compliance Laboratories Corp. (Dongguan)                                             Report No.: RSZ151118002-00A

                                      Power Spectral Density, Middle Channel
                                         Marker 1 [T1]               RBW   500 kHz     RF Att      30 dB
                          Ref Lvl                    15.65 dBm       VBW    2 MHz
                           29.5 dBm             5.75951403 GHz       SWT    5 ms       Unit           dBm
                   29.5
                            10.5 dB Offset                                    1 [T1]            15.65 dBm
                                                                                                             A
                                                                                        5.75951403 GHz
                     20
                                                          1


                     10



                      0
                          1MAX                                                                              1RM

                    -10



                    -20



                    -30



                    -40



                    -50



                    -60



                  -70.5
                          Center 5.76 GHz                     500 kHz/                         Span 5 MHz

                  Date:          22.DEC.2015   16:57:05



                                       Power Spectral Density, High Channel
                                         Marker 1 [T1]               RBW   500 kHz     RF Att      30 dB
                          Ref Lvl                    15.50 dBm       VBW     2 MHz
                          29.5 dBm              5.79853407 GHz       SWT     5 ms      Unit           dBm
                   29.5
                            10.5 dB Offset                                    1 [T1]            15.50 dBm
                                                                                                             A
                                                                                        5.79853407 GHz
                     20
                                                          1


                     10



                      0
                          1MAX                                                                              1RM

                    -10



                    -20



                    -30



                    -40



                    -50



                    -60



                  -70.5
                          Center 5.799 GHz                    500 kHz/                         Span 5 MHz

                  Date:          22.DEC.2015   16:23:00


                                            ***** END OF REPORT *****
FCC Part 15.407                                                                                                   Page 27 of 27



Document Created: 2017-11-16 03:37:03
Document Modified: 2017-11-16 03:37:03

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC