                               Global United Technology Services Co., Ltd.

                                                                                  Report No.: GTS201704000138F02



                                           FCC Report
 Applicant:                           Grand Electronics, INC

 Address of Applicant:                11650 Brentcross Dr, 11650, Tomball, Texas 77377, United
                                      States

 Manufacturer:                        Shenzhen BAKER Electronics Co.LTD

 Address of                           6/F.A.Building,The first industrial area of Fenghuang, Fuyong,
 Manufacturer:                        Bao'an, Shenzhen, China

 Equipment Under Test (EUT)
   Product Name:                      Sports DV
   Model No.:                         LY1-DVS, LY2-DVS, Xtre-SN, Xtrem-LY
   Trade Mark:                        neutab.

 FCC ID:                              2AGNK-LYDV1
 Applicable standards:                FCC CFR Title 47 Part 15 Subpart B:2016
 Date of sample receipt:              May 13, 2017

 Date of Test:                        May 13-16, 2017
 Date of report issue:                May 17, 2017
 Test Result :                        PASS *
* In the configuration tested, the EUT complied with the standards specified above.




 Authorized Signature:




   Robinson Lo
Laboratory Manager
This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in
full, without prior written permission of the company. The report would be invalid without specific stamp of test institute
and the signatures of compiler and approver.


                                                                                Report No.: GTS201704000138F02

2 Version
      Version No.                         Date                                    Description

            01                       May 17, 2017                                   Original




Prepared By:                                                        Date:                 May 17, 2017


                                     Project Engineer



Check By:                                                           Date:                 May 17, 2017


                                          Reviewer




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                        Page 2 of 18


                                                                                                            Report No.: GTS201704000138F02

3 Contents
                                                                                                                                                          Page
1     COVER PAGE ........................................................................................................................................... 1

2     VERSION .................................................................................................................................................. 2

3     CONTENTS .............................................................................................................................................. 3

4     TEST SUMMARY ..................................................................................................................................... 4
    4.1       MEASUREMENT UNCERTAINTY............................................................................................................. 4
5     GENERAL INFORMATION ...................................................................................................................... 5
    5.1       GENERAL DESCRIPTION OF EUT ......................................................................................................... 5
    5.2       TEST MODE ....................................................................................................................................... 5
    5.3       TEST FACILITY .................................................................................................................................... 6
    5.4       TEST LOCATION .................................................................................................................................. 6
    5.5       DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 6
    5.6       DEVIATION FROM STANDARDS ............................................................................................................. 6
    5.7       ABNORMALITIES FROM STANDARD CONDITIONS .................................................................................... 6
    5.8       OTHER INFORMATION REQUESTED BY THE CUSTOMER ......................................................................... 6
6     TEST INSTRUMENTS LIST ..................................................................................................................... 7

7     TEST RESULTS AND MEASUREMENT DATA...................................................................................... 8
    7.1       CONDUCTED EMISSIONS ..................................................................................................................... 8
    7.2       RADIATED EMISSION ......................................................................................................................... 11
8     TEST SETUP PHOTO ............................................................................................................................ 17

9     EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 18




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                                                                   Page 3 of 18


                                                                                Report No.: GTS201704000138F02

4 Test Summary
                  Test Item                               Section in CFR 47                      Result
Conducted Emission                                             Part15.107                        PASS
Radiated Emissions                                             Part15.109                        PASS
PASS: The EUT complies with the essential requirements in the standard.
Remark :Test according to ANSI C63.4:2014.


4.1 Measurement Uncertainty
            Test Item                       Frequency Range               Measurement Uncertainty       Notes
       Radiated Emission                      9kHz ~ 30MHz                         ± 4.34dB               (1)
       Radiated Emission                   30MHz ~ 1000MHz                         ± 4.24dB               (1)
       Radiated Emission                     1GHz ~ 26.5GHz                        ± 4.68dB               (1)
   AC Power Line Conducted
                                            0.15MHz ~ 30MHz                        ± 3.45dB               (1)
         Emission
Note (1): The measurement uncertainty is for coverage factor of k=2 and a level of confidence of 95%.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                        Page 4 of 18


                                                                                Report No.: GTS201704000138F02

5 General Information
5.1 General Description of EUT
      Product Name:                      Sports DV
      Model No.:                         LY1-DVS, LY2-DVS, Xtre-SN, Xtrem-LY
      Test Model No.:                    LY1-DVS
      Remark: All above models are identical in the same PCB layout, interior structure and electrical
      circuits. The only difference is the model name for commercial purpose.
      Power Supply:                     DC 3.7V, 1000mAh, 3.7Wh Li-ion battery
5.2 Test mode
      Test mode:
       PC mode                           Keep the EUT in exchange data status with PC.
       REC mode                          Keep the EUT in video record mode.
       HDMI mode                         Keep the EUT in video playing and HDMI output mode.
       Take photo mode                   Keep the EUT in taking photos.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                        Page 5 of 18


                                                                                 Report No.: GTS201704000138F02


5.3 Test Facility
       The test facility is recognized, certified, or accredited by the following organizations:
       ● FCC —Registration No.: 600491
       Global United Technology Services Co., Ltd., Shenzhen EMC Laboratory has been registered and
       fuly described in a report filed with the (FCC) Federal Communications Commission. The acceptance
       letter from the FCC is maintained in files. Registration 600491, June 22, 2016.
       ● Industry Canada (IC) —Registration No.: 9079A-2
       The 3m Semi-anechoic chamber of Global United Technology Services Co., Ltd. has been registered
       by Certification and Engineering Bureau of Industry Canada for radio equipment testing with
       Registration No.: 9079A-2, August 15, 2016.
5.4 Test Location
       All tests were performed at:
       Global United Technology Services Co., Ltd.
       No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan
       District, Shenzhen, Guangdong, China 518102
       Tel: 0755-27798480
       Fax: 0755-27798960
5.5 Description of Support Units
    Manufacturer              Description                 Model                 Serial Number    FCC ID/DoC
       DELL                   KEYBOARD                   SK-8115                     N/A            DOC
         DELL                   MOUSE                      N/A                      N/A             DOC
         Apple                     PC                     A1278             C1MN99ERDTY3            DOC
        DELTA                  ADAPTER                 ADP-60ADT                    N/A              DoC
5.6 Deviation from Standards
      Biconical, log.per. antenna and horn antenna were used instead of dipole antenna.
      Semi-anechoic Chamber was used as alternation of open air test sites, and all test suites were
      performed with radiated method in it.
5.7 Abnormalities from Standard Conditions
      None.
5.8 Other Information Requested by the Customer
      None.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                         Page 6 of 18


                                                                                 Report No.: GTS201704000138F02



6         Test Instruments list
Radiated Emission:
                                                                                Inventory      Cal.Date       Cal.Due date
Item         Test Equipment         Manufacturer           Model No.
                                                                                   No.        (mm-dd-yy)      (mm-dd-yy)
            3m Semi- Anechoic
 1                                ZhongYu Electron   9.2(L)*6.2(W)* 6.4(H)      GTS250       July 03 2015    July 02 2020
                Chamber
 2            Control Room        ZhongYu Electron   6.2(L)*2.5(W)* 2.4(H)      GTS251           N/A              N/A
 3          Spectrum Analyzer         Agilent               E4440A              GTS533       June 29 2016    June 28 2017
 4          EMI Test Receiver     Rohde & Schwarz           ESU26               GTS203       June 29 2016    June 28 2017
                                  SCHWARZBECK
 5         BiConiLog Antenna                              VULB9163              GTS214       June 29 2016    June 28 2017
                                 MESS-ELEKTRONIK
         Double -ridged waveguide SCHWARZBECK
 6                                                        9120D-829             GTS208       June 29 2016    June 28 2017
                    horn         MESS-ELEKTRONIK
 7            Horn Antenna        ETS-LINDGREN               3160               GTS217       June 29 2016    June 28 2017
 8          EMI Test Software         AUDIX                   E3                 N/A             N/A             N/A
 9            Coaxial Cable            GTS                    N/A               GTS213       June 29 2016    June 28 2017
10            Coaxial Cable            GTS                    N/A               GTS211       June 29 2016    June 28 2017
11            Coaxial cable            GTS                    N/A               GTS210       June 29 2016    June 28 2017
12            Coaxial Cable            GTS                    N/A               GTS212       June 29 2016    June 28 2017
13       Amplifier(100kHz-3GHz)         HP                  8347A               GTS204       June 29 2016    June 28 2017
14       Amplifier(2GHz-20GHz)          HP                  8349B               GTS206       June 29 2016    June 28 2017
                                                         AFS33-18002
15         Amplifier (18-26GHz)   Rohde & Schwarz                               GTS218       June 29 2016    June 28 2017
                                                         650-30-8P-44
16             Band filter           Amindeon               82346               GTS219       June 29 2016    June 28 2017
17            Power Meter             Anritsu              ML2495A              GTS540       June 29 2016    June 28 2017
18            Power Sensor            Anritsu              MA2411B              GTS541       June 29 2016    June 28 2017


Conducted Emission:
                                                                                 Inventory      Cal.Date      Cal.Due date
 Item          Test Equipment       Manufacturer            Model No.
                                                                                    No.        (mm-dd-yy)     (mm-dd-yy)
     1         Shielding Room     ZhongYu Electron     7.3(L)x3.1(W)x2.9(H)      GTS252        May.16 2014 May.15 2019
     2        EMI Test Receiver        R&S                    ESCI 7             GTS552       June. 29 2016 June. 28 2017
     3         Coaxial Switch     ANRITSU CORP                MP59B              GTS225       June. 29 2016 June. 28 2017
               Artificial Mains   SCHWARZBECK
     4                                                      NSLK8127             GTS226       June. 29 2016 June. 28 2017
                   Network             MESS
     5          Coaxial Cable          GTS                     N/A               GTS227            N/A           N/A
     6        EMI Test Software       AUDIX                    E3                 N/A              N/A           N/A
     7          Thermo meter            KTJ                   TA328              GTS233       June. 29 2016 June. 28 2017




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                                 Page 7 of 18


                                                                                Report No.: GTS201704000138F02


7 Test Results and Measurement Data
7.1 Conducted Emissions
      Test Requirement:                FCC Part15 B Section 15.107
      Test Method:                     ANSI C63.4:2014
      Test Frequency Range:            150KHz to 30MHz
      Class / Severity:                Class B
      Receiver setup:                  RBW=9KHz, VBW=30KHz, Sweep time=auto
      Limit:                                                                         Limit (dBuV)
                                          Frequency range (MHz)
                                                                          Quasi-peak              Average
                                                 0.15-0.5                   66 to 56*             56 to 46*
                                                  0.5-5                         56                   46
                                                   5-30                         60                   50
                                       * Decreases with the logarithm of the frequency.
      Test setup:




      Test procedure:                  1. The E.U.T and simulators are connected to the main power through a
                                          line impedance stabilization network (L.I.S.N.). This provides a
                                          50ohm/50uH coupling impedance for the measuring equipment.
                                       2. The peripheral devices are also connected to the main power through a
                                          LISN that provides a 50ohm/50uH coupling impedance with 50ohm
                                          termination. (Please refer to the block diagram of the test setup and
                                          photographs).
                                       3. Both sides of A.C. line are checked for maximum conducted
                                          interference. In order to find the maximum emission, the relative
                                          positions of equipment and all of the interface cables must be changed
                                          according to ANSI C63.4: 2014 on conducted measurement.
      Test Instruments:                Refer to section 6 for details
      Test mode:                       Refer to section 5.2 for details, and found the PC mode which is the worst
                                       mode, so only the data of worst mode was show on the test report.
      Test results:                    Pass




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                        Page 8 of 18


                                                                                Report No.: GTS201704000138F02
Measurement Data
Test mode:                    PC mode                       Phase Polarity:              Line




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                        Page 9 of 18


                                                                                Report No.: GTS201704000138F02


Test mode:                    PC mode                       Phase Polarity:                  Neutral




Notes:
1. An initial pre-scan was performed on the line and neutral lines with peak detector.
2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. Final Level =Receiver Read level + LISN Factor + Cable Loss
4. If the average limit is met when using a quasi-peak detector receiver, the EUT shall be deemed to meet both limits
   and measurement with the average detector receiver is unnecessary.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                             Page 10 of 18


                                                                                Report No.: GTS201704000138F02

7.2 Radiated Emission
      Test Requirement:                FCC Part15 B Section 15.109
      Test Method:                     ANSI C63.4:2014
      Test Frequency Range:            30MHz to 25GHz
      Test site:                       Measurement Distance: 3m (Semi-Anechoic Chamber)
      Receiver setup:
                                         Frequency         Detector         RBW          VBW         Remark
                                          30MHz-          Quasi-peak       120kHz       300kHz   Quasi-peak Value
                                           1GHz
                                                              Peak          1MHz        3MHz       Peak Value
                                        Above 1GHz
                                                              Peak          1MHz        10Hz      Average Value
      Limit:
                                                Frequency               Limit (dBuV/m @3m)           Remark
                                              30MHz-88MHz                       40.00            Quasi-peak Value
                                             88MHz-216MHz                       43.50            Quasi-peak Value
                                             216MHz-960MHz                      46.00            Quasi-peak Value
                                              960MHz-1GHz                       54.00            Quasi-peak Value
                                                                                54.00             Average Value
                                               Above 1GHz
                                                                                74.00              Peak Value

      Test Procedure:                  1. The EUT was placed on the top of a rotating table 0.8 meters above the
                                          ground at a 3 meter camber. The table was rotated 360 degrees to
                                          determine the position of the highest radiation.
                                       2. The EUT was set 3 meters away from the interference-receiving
                                          antenna, which was mounted on the top of a variable-height antenna
                                          tower.
                                       3. The antenna height is varied from one meter to four meters above the
                                          ground to determine the maximum value of the field strength. Both
                                          horizontal and vertical polarizations of the antenna are set to make the
                                          measurement.
                                       4. For each suspected emission, the EUT was arranged to its worst case
                                          and then the antenna was tuned to heights from 1 meter to 4 meters
                                          and the rota table was turned from 0 degrees to 360 degrees to find the
                                          maximum reading.
                                       5. The test-receiver system was set to Peak Detect Function and Specified
                                          Bandwidth with Maximum Hold Mode.
                                       6. If the emission level of the EUT in peak mode was 10dB lower than the
                                          limit specified, then testing could be stopped and the peak values of the
                                          EUT would be reported. Otherwise the emissions that did not have
                                          10dB margin would be re-tested one by one using peak, quasi-peak or
                                          average method as specified and then reported in a data sheet.
      Test setup:                      Below 1GHz




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                         Page 11 of 18


                                                                                Report No.: GTS201704000138F02




                                       Above 1GHz




                                                80cm




      Test environment:                Temp.:       25 °C         Humid.:        52%       Press.:     1 012mbar
       Measurement Record:                                                                 Uncertainty: ± 4.5dB
      Test Instruments:                Refer to section 6 for details
      Test mode:                       Refer to section 5.2 for details, and found the PC mode which is the worst
                                       mode, so only the data of worst mode was show on the test report.
      Test results:                    Pass


Note:
The field strength is calculated by adding the Antenna Factor, Cable Factor & Preamplifier. The basic
equation with a sample calculation is as follows:

Final Test Level =Receiver Reading + Antenna Factor + Cable Factor – Preamplifier Factor

For above 1GHz test,1GHz to 25GHz all have been tested, only worse case 1GHz to 6GHz is reported, from
6GHz to 25GHz, no emission is found




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                          Page 12 of 18


                                                                                 Report No.: GTS201704000138F02
Measurement Data
Below 1GHz
Test mode:                    PC mode                        Antenna Polarity:              Horizontal




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                         Page 13 of 18


                                                                                 Report No.: GTS201704000138F02


Test mode:                    PC mode                        Antenna Polarity:              Vertical




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                            Page 14 of 18


                                                                                 Report No.: GTS201704000138F02
Above 1GHz
Test mode:                    PC mode                        Antenna Polarity:              Horizontal




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                         Page 15 of 18


                                                                                 Report No.: GTS201704000138F02


Test mode:                    PC mode                        Antenna Polarity:              Vertical




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                            Page 16 of 18


                                                                                Report No.: GTS201704000138F02


8 Test Setup Photo
      Radiated Emission




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                       Page 17 of 18


                                                                                Report No.: GTS201704000138F02


      Conducted Emission




9 EUT Constructional Details
       Reference to the test report No. GTS201704000138E01


                                                    ------ End------




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                       Page 18 of 18



Document Created: 2017-05-17 20:35:22
Document Modified: 2017-05-17 20:35:22

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC