Test Report

FCC ID: 2AGN8-E21N1EA

Test Report

Download: PDF
FCCID_4474534

                           EMC TEST REPORT


                           Applicant            Sengled Co., Ltd.

                           FCC ID               2AGN8-E21N1EA

                           Product              Sengled Smart LED

                           Brand                sengled

                           Model                E21-N1EA

                           Report No.           R1908A0493-E1V1

                           Issue Date           September 18, 2019


TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in FCC
Code CFR47 Part15B (2018)/ ANSI C63.4 (2014). The test results show that the equipment tested is capable of
demonstrating compliance with the requirements as documented in this report.




              Performed by: Wei Liu/ Manager           Approved by: Guangchang Fan/ Director




               TA Technology (Shanghai) Co., Ltd.
                     No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China
                                        TEL: +86‐021‐50791141/2/3
                                     FAX: +86‐021‐50791141/2/3‐8000


             EMC Test Report                                                                           Report No.: R1908A0493-E1V1



                                                     Table of Contents
1  Test Laboratory............................................................................................................................... 4
 1.1    Notes of the Test Report ......................................................................................................... 4
 1.2    Test facility .............................................................................................................................. 4
 1.3    Testing Location ...................................................................................................................... 5
2 General Description of Equipment under Test ................................................................................ 6
 2.1    Client Information .................................................................................................................... 6
 2.2    General information ................................................................................................................. 6
 2.3    Applied Standards ................................................................................................................... 7
 2.4    Test Mode................................................................................................................................ 8
3 Test Case Results .......................................................................................................................... 9
 3.1    Radiated Emission .................................................................................................................. 9
 3.2    Conducted Emission ............................................................................................................. 14
4 Main Test Instrument .................................................................................................................... 17




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 2 of 17
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           EMC Test Report                                                              Report No.: R1908A0493-E1V1




                                 Summary of measurement results
   Number              Test Case                        Clause in FCC Rules                              Conclusion
          1            Radiated Emission                FCC Part15.109, ANSI C63.4-2014                       PASS
          2            Conducted Emission               FCC Part15.107, ANSI C63.4-2014                       PASS
                                  Test Date: August 17, 2019 ~ August 18, 2019




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 3 of 17
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           EMC Test Report                                                              Report No.: R1908A0493-E1V1




1 Test Laboratory

1.1 Notes of the Test Report

This report shall not be reproduced in full or partial, without the written approval of TA technology
(shanghai) co., Ltd. The results documented in this report apply only to the tested sample, under the
conditions and modes of operation as described herein .Measurement Uncertainties were not taken
into account and are published for informational purposes only. This report is written to support
regulatory compliance of the applicable standards stated above.


1.2 Test facility

FCC (Designation number: CN1179, Test Firm Registration Number: 446626)
TA Technology (Shanghai) Co., Ltd. has been listed on the US Federal Communications Commission
list of test facilities recognized to perform electromagnetic emissions measurements.
IC (recognition number is 8510A)
TA Technology (Shanghai) Co., Ltd. has been listed by industry Canada to perform electromagnetic
emission measurement.
VCCI (recognition number is C-4595, T-2154, R-4113, G-10766)
TA Technology (Shanghai) Co., Ltd. has been listed by industry Japan to perform electromagnetic
emission measurement.
A2LA (Certificate Number: 3857.01)
TA Technology (Shanghai) Co., Ltd. has been listed by American Association for Laboratory
Accreditation to perform electromagnetic emission measurement.




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 4 of 17
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           EMC Test Report                                                              Report No.: R1908A0493-E1V1


1.3 Testing Location


   Company:             TA Technology (Shanghai) Co., Ltd.

   Address:             No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China

   City:                Shanghai

   Post code:           201201
   Country:             P. R. China

   Contact:             Xu Kai

   Telephone:           +86-021-50791141/2/3

   Fax:                 +86-021-50791141/2/3-8000
   Website:             http://www.ta-shanghai.com

   E-mail:              xukai@ta-shanghai.com




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 5 of 17
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           EMC Test Report                                                              Report No.: R1908A0493-E1V1




2 General Description of Equipment under Test

2.1 Client Information

   Applicant                             Sengled Co., Ltd.
                                         Room 201/15,Building 1, No.498, Guoshoujing Road, Pilot Free
   Applicant address
                                         Trade Zone Shanghai, P.R. China
   Manufacturer                          Sengled Co., Ltd.
                                         Room 201/15,Building 1, No.498, Guoshoujing Road, Pilot Free
   Manufacturer address
                                         Trade Zone Shanghai, P.R. China



2.2 General information

                                                    EUT Description
Device Type:                  Fixed Device
Model:                        E21-N1EA
SN:                           1929D500108
HW Version:                   V3
SW Version:                   V16
Antenna Type:                 PCB Antenna
                                        Band                         Tx (MHz)                          Rx (MHz)
Frequency:
                              Zigbee                               2405 ~ 2480                       2405 ~ 2480
Modulation:                   Zigbee: O-QPSK
                                               Auxiliary test equipment
                              PC Manufacturer: Microsoft Corporation
PC
                              Model: L20170076
Note: The information of the EUT is declared by the manufacturer.




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 6 of 17
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           EMC Test Report                                                              Report No.: R1908A0493-E1V1


2.3 Applied Standards

According to the specifications of the manufacturer, it must comply with the requirements of the
following standards:

Test standards
FCC Code CFR47 Part15B (2018)
ANSI C63.4 (2014)




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 7 of 17
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           EMC Test Report                                                              Report No.: R1908A0493-E1V1


2.4 Test Mode

     Test Mode
     Mode 1                      EUT with PC power supply + Idle




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 8 of 17
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           EMC Test Report                                                              Report No.: R1908A0493-E1V1




3 Test Case Results

3.1 Radiated Emission

Ambient condition

                  Temperature                Relative humidity                         Pressure

                   24°C~26°C                     45%~50%                               102.5kPa



Methods of Measurement

The EUT is placed on a non-metallic table 0.8m above the horizontal metal reference ground plane.
The distance between EUT and receive antenna should be 3 meters. During the test, the EUT was
operating in its typical mode. The test method is according to ANSI C63.4-2014. Sweep the whole
frequency band through the range from 30MHz to the 5th harmonic of the carrier. During the test, the
height of receive antenna shall be moved from 1 to 4 meters, and the antenna shall be performed
under horizontal and vertical polarization. The turn table shall be rotated from 0 to 360 degrees for
detecting the maximum of radiated signal level.
The data of cable loss and antenna factor has been calibrated in full testing frequency range before
the testing. During the test, the EUT is worked at maximum output power.
Set the spectrum analyzer in the following:
Below 1GHz:
RBW=100 kHz / VBW=300 kHz / Sweep=AUTO
Above 1GHz:
(a) PEAK: RBW=1MHz / VBW=3MHz/ Sweep=AUTO
(b) AVERAGE: RBW=1MHz / VBW=3MHz / Sweep=AUTO

The radiated emission was measured in the following position: EUT stand-up position (Z axis),
lie-down position (X, Y axis). The worst emission was found in lie-down position (X axis) and the
worst case was recorded.




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 9 of 17
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           EMC Test Report                                                              Report No.: R1908A0493-E1V1

Test Setup



Below 1GHz




     Above 1GHz




Note: Area side:2.4mX3.6m

Antenna Tower meets ANSI C63.4 requirements for measurements above 1 GHz by keeping the
antenna aimed at the EUT during the antenna’s ascent/ descent along the antenna mast.




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 10 of 17
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           EMC Test Report                                                              Report No.: R1908A0493-E1V1
Limits

                  Frequency                               Field Strength
                                                                                                   Detector
                    (MHz)                                   (dBμV/m)
                     30 -88                                     40.0                              Quasi-peak
                    88-216                                      43.5                              Quasi-peak
                   216 – 960                                    46.0                              Quasi-peak
                   960-1000                                     54.0                              Quasi-peak
     1000-5th harmonic of the highest                             54                                Average
   frequency or 40GHz,which is lower                              74                                  Peak



Measurement Uncertainty

The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution is
with the coverage factor k = 1.96.


                              Frequency                                           Uncertainty
                         30MHz~200MHz                                               4.02 dB
                        200MHz~1000MHz                                              3.28 dB
                           1GHz~18GHz                                               3.70 dB
                         18GHz~26.5GHz                                              5.78 dB
                         26.5GHz~40GHz                                              5.82 dB




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 11 of 17
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


                          EMC Test Report                                                               Report No.: R1908A0493-E1V1
Test Results

Sweep the whole frequency band through the range from 30MHz to the 5th harmonic of the carrier,
the Emissions in the frequency band 18GHz- 26.5GHz is more than 20dB below the limit are not
reported.

The following graphs display the maximum values of horizontal and vertical by software.
For above 1GHz, Blue trace uses the peak detection, Green trace uses the average detection.

                           100

                           90

                           80

                           70

                           60
                                                                                                                  FCC RE QP
         Level in dBμV/




                           50

                           40

                           30

                           20

                            10

                            0
                            30M             50   60      80   100M            200         300     400     500       800   1G

                                                                     Frequency in Hz


                                                      Radiated Emission from 30MHz to 1GHz
Frequency                        Quasi-Peak Height              Azimuth                          Correct         Margin   Limit
                                                   Polarization
  (MHz)                           (dBuV/m)   (cm)                (deg)                          Factor (dB)       (dB)  (dBuV/m)
47.213991                           21.5              120.0          V          166.0              -4.5            18.5        40.0
83.504466                           23.3              100.0          V          124.0              -11.8           16.7        40.0
94.510631                           22.7              219.0          H          181.0              -10.2           20.8        43.5
204.260750                          13.3              100.0          V          180.0              -12.5           30.2        43.5
379.905000                          21.6              100.0          H          82.0               -5.6            24.4        46.0
948.053000                          25.9              125.0          H              0.0             1.9            20.1        46.0
Remark: 1. Correction Factor = Antenna factor+ Insertion loss(cable loss+amplifier gain)
        2. Margin = Limit – Quasi-Peak




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 12 of 17
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           EMC Test Report                                                                        Report No.: R1908A0493-E1V1




                              120

                              110

                              100

                              90

                              80
                                                                                                          FCC RE PK(Class B)
             Level in dBμV/




                              70

                              60
                                                                                                          FCC RE AV(Class B)
                              50

                              40

                              30

                              20

                               10
                                    1    2          4            6    8        10          12       14          16         18

                                                                      Frequency in GHz


                                                        Radiated Emission from 1GHz to 18GHz
                                                                                                Correct
                                          Peak   Height              Azimuth                                 Margin   Limit
    Frequency                                           Polarization                            Factor
                                        (dBuV/m) (cm)                 (deg)                                   (dB)  (dBuV/m)
      (MHz)                                                                                      (dB)
   1437.750000                               36.5        200.0       H          131.0            -8.0         37.5             74.0
   2572.500000                               39.9        100.0       V          327.0            -3.5         34.1             74.0
   4238.500000                               43.6        200.0       H              94.0          2.2         30.4             74.0
   6862.875000                               47.6        100.0       V          279.0             7.7         26.4             74.0
  10600.750000                               51.1        200.0       H          173.0            11.9         22.9             74.0
  15033.500000                               58.2        200.0       V          151.0            17.6         15.8             74.0


                                                                                                Correct
    Frequency                            Average Height              Azimuth                                 Margin   Limit
                                                        Polarization                            Factor
      (MHz)                             (dBuV/m) (cm)                 (deg)                                   (dB)  (dBuV/m)
                                                                                                 (dB)
   1571.625000                               26.5        100.0       V          131.0            -7.6         27.5             54.0
   2589.500000                               29.1        200.0       H          100.0            -3.4         24.9             54.0
   4183.250000                               33.2        100.0       V          357.0             2.1         20.8             54.0
   6716.250000                               37.4        100.0       V          357.0             7.6         16.6             54.0
  10968.375000                               40.6        100.0       H              95.0         12.6         13.4             54.0
  15054.750000                               47.4        200.0       V          237.0            17.7          6.6             54.0




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 13 of 17
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


             EMC Test Report                                                            Report No.: R1908A0493-E1V1




3.2 Conducted Emission

Ambient condition

                  Temperature                Relative humidity                         Pressure

                   24°C ~26°C                    50%~55%                               102.5kPa

Methods of Measurement

The EUT is placed on a non-metallic table of 80cm height above the horizontal metal reference
ground plane. During the test, the EUT was operating in its typical mode. The test method is
according to ANSI C63.4-2014. Connect the AC power line of the EUT to the L.I.S.N. Use EMI
receiver to detect the average and Quasi-peak value. RBW is set to 9 kHz, VBW is set to 30kHz. The
measurement result should include both L line and N line.


Test Setup




Note: Power Supply is AC Power source and it is used to change the voltage 120V/60Hz.

Limits

           Frequency                                            Conducted Limits(dBμV)
             (MHz)                              Quasi-peak                                      Average
                                                            *                                            *
            0.15 - 0.5                           66 to 56                                      56 to 46
              0.5 - 5                                56                                            46
              5 - 30                                 60                                            50
   *:
        Decreases with the logarithm of the frequency.

Measurement Uncertainty

The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution is
with the coverage factor k = 1.96. U= 2.57 dB.

TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 14 of 17
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           EMC Test Report                                                              Report No.: R1908A0493-E1V1
Test Results

Following plots, Blue trace uses the peak detection; Green trace uses the average detection.




                                                                          Meas.
Frequency        QuasiPeak         Average        Limit      Margin                  Bandwidth                           Corr.
                                                                          Time                        Line     Filter
  (MHz)           (dBµV)           (dBµV)        (dBµV)       (dB)                     (kHz)                             (dB)
                                                                          (ms)
    0.15            53.17              ---        66.00       12.83      1000.0          9.000          L1      ON       19.06
    0.15               ---           31.33        55.88       24.55      1000.0          9.000          L1      ON       19.05
    0.59               ---           14.57        46.00       31.43      1000.0          9.000          L1      ON       19.27
    0.79            18.02              ---        56.00       37.98      1000.0          9.000          L1      ON       19.24
    1.05               ---           12.88        46.00       33.12      1000.0          9.000          L1      ON       19.24
    1.12            16.76              ---        56.00       39.24      1000.0          9.000          L1      ON       19.24
    2.94            14.95              ---        56.00       41.05      1000.0          9.000          L1      ON       19.09
    3.59               ---           13.93        46.00       32.07      1000.0          9.000          L1      ON       19.07
    7.93            19.37              ---        60.00       40.63      1000.0          9.000          L1      ON       19.21
    7.98               ---           15.81        50.00       34.19      1000.0          9.000          L1      ON       19.21
   29.95            16.92              ---        60.00       43.08      1000.0          9.000          L1      ON       19.84
   29.96               ---           15.77        50.00       34.23      1000.0          9.000          L1      ON       19.84
Remark: Correct factor=cable loss + LISN factor
                                           L line
                        Conducted Emission from 150 KHz to 30 MHz




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 15 of 17
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           EMC Test Report                                                              Report No.: R1908A0493-E1V1




                                                                          Meas.
Frequency        QuasiPeak         Average        Limit      Margin                  Bandwidth                           Corr.
                                                                          Time                        Line     Filter
  (MHz)           (dBµV)           (dBµV)        (dBµV)       (dB)                     (kHz)                             (dB)
                                                                          (ms)
    0.15            52.45              ---        66.00       13.55      1000.0          9.000          N       ON       19.08
    0.15               ---           30.43        55.88       25.45      1000.0          9.000          N       ON       19.07
    0.57            20.07              ---        56.00       35.93      1000.0          9.000          N       ON       19.26
    0.79               ---           15.39        46.00       30.61      1000.0          9.000          N       ON       19.24
    1.00            18.79              ---        56.00       37.21      1000.0          9.000          N       ON       19.24
    1.03               ---           15.91        46.00       30.09      1000.0          9.000          N       ON       19.24
    3.55               ---           13.90        46.00       32.10      1000.0          9.000          N       ON       19.06
    4.03            15.96              ---        56.00       40.04      1000.0          9.000          N       ON       19.05
    7.80               ---           15.27        50.00       34.73      1000.0          9.000          N       ON       19.22
    8.18            17.81              ---        60.00       42.19      1000.0          9.000          N       ON       19.22
   29.94            16.97              ---        60.00       43.03      1000.0          9.000          N       ON       19.68
   29.95               ---           15.71        50.00       34.29      1000.0          9.000          N       ON       19.68
Remark: Correct factor=cable loss + LISN factor
                                           N line
                        Conducted Emission from 150 KHz to 30 MHz




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 16 of 17
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           EMC Test Report                                                              Report No.: R1908A0493-E1V1




4 Main Test Instrument

                                                                            Serial        Calibration        Expiration
         Name                 Manufacturer                 Type
                                                                           Number            Date              Time
       Spectrum                                                           15195-01-
                                    R&S                   FSV40                            2019-05-19        2020-05-18
       Analyzer                                                              00
       EMI Test
                                    R&S                    ESCI             100948        2019-05-19         2020-05-18
       Receiver
    Trilog Antenna          SCHWARZBECK                VULB 9163          9163-201         2017-11-18        2019-11-17
    Horn Antenna                    R&S                   HF907             100126        2018-07-07         2020-07-06
    Standard Gain
                              ETS-Lindgren               3160-09          00102643        2018-06-20         2020-06-19
        Horn
       EMI Test
                                    R&S                    ESR              101667        2019-05-19         2020-05-18
       Receiver
          LISN                      R&S                  ENV216             101171        2016-12-16        2019-12-15
     Bore Sight
                                    ETS                   2171B           00058752               /                 /
    Antenna mast
    Test software                 EMC32                    R&S               9.26.0              /                 /




                                             *****END OF REPORT *****




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 17 of 17
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.



Document Created: 2019-10-11 03:58:14
Document Modified: 2019-10-11 03:58:14

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC