MPE Report

FCC ID: 2AGN8-E21N1EA

RF Exposure Info

Download: PDF
FCCID_4474520

                            MPE TEST REPORT


                            Applicant            Sengled Co., Ltd.

                            FCC ID               2AGN8-E21N1EA

                            Product              Sengled Smart LED

                            Brand                sengled

                            Model                E21-N1EA

                            Report No.           R1908A0493-M1V1

                            Issue Date           September 18, 2019


TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in FCC
47 CFR Part 1 1.1310. The test results show that the equipment tested is capable of demonstrating compliance
with the requirements as documented in this report.




                    Performed by: Yu Wang                 Approved by: Guangchang Fan




               TA Technology (Shanghai) Co., Ltd.
                  No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China
                                        TEL: +86-021-50791141/2/3
                                     FAX: +86-021-50791141/2/3-8000


          MPE Test Report                                                                                     Report No.: R1908A0493‐M1V1




                                                     Table of Contents
1  Test Laboratory............................................................................................................................... 3
 1.1    Notes of the Test Report ......................................................................................................... 3
 1.2    Test facility .............................................................................................................................. 3
 1.3    Testing Location ...................................................................................................................... 4
 1.4    Laboratory Environment .......................................................................................................... 4
2 Description of Equipment under Test .............................................................................................. 5
3 Maximum conducted output power (measured) and antenna Gain ................................................ 6
4 Test Result ..................................................................................................................................... 7




TA Technology (Shanghai) Co., Ltd.                                                                                  Page 2 of 9
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


        MPE Test Report                                                                       Report No.: R1908A0493‐M1V1




1 Test Laboratory

1.1 Notes of the Test Report

This report shall not be reproduced in full or partial, without the written approval of TA technology

(shanghai) co., Ltd.The results documented in this report apply only to the tested sample, under the

conditions and modes of operation as described herein .Measurement Uncertainties were not taken

into account and are published for informational purposes only. This report is written to support

regulatory compliance of the applicable standards stated above.


1.2 Test facility

FCC (Designation number: CN1179, Test Firm Registration Number: 446626)
TA Technology (Shanghai) Co., Ltd. has been listed on the US Federal Communications Commission
list of test facilities recognized to perform electromagnetic emissions measurements.
IC (recognition number is 8510A)
TA Technology (Shanghai) Co., Ltd. has been listed by industry Canada to perform electromagnetic
emission measurement.
VCCI (recognition number is C-4595, T-2154, R-4113, G-10766)
TA Technology (Shanghai) Co., Ltd. has been listed by industry Japan to perform electromagnetic
emission measurement.
A2LA (Certificate Number: 3857.01)
TA Technology (Shanghai) Co., Ltd. has been listed by American Association for Laboratory
Accreditation to perform electromagnetic emission measurement.




TA Technology (Shanghai) Co., Ltd.                                                                                  Page 3 of 9
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           MPE Test Report                                                                    Report No.: R1908A0493‐M1V1


1.3 Testing Location


   Company:             TA Technology (Shanghai) Co., Ltd.

   Address:             No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China

   City:                Shanghai

   Post code:           201201
   Country:             P. R. China

   Contact:             Xu Kai

   Telephone:           +86-021-50791141/2/3

   Fax:                 +86-021-50791141/2/3-8000
   Website:             http://www.ta-shanghai.com

   E-mail:              xukai@ta-shanghai.com




1.4 Laboratory Environment

   Temperature                                             Min. = 18C, Max. = 25 C

   Relative humidity                                       Min. = 30%, Max. = 70%

   Ground system resistance                                < 0.5 
   Ambient noise is checked and found very low and in compliance with requirement of standards.
   Reflection of surrounding objects is minimized and in compliance with requirement of standards.




TA Technology (Shanghai) Co., Ltd.                                                                                  Page 4 of 9
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


        MPE Test Report                                                                       Report No.: R1908A0493‐M1V1


2 Description of Equipment under Test

 Client Information
   Applicant                           Sengled Co., Ltd.
                                       Room 201/15,Building 1, No.498, Guoshoujing Road, Pilot Free
   Applicant address
                                       Trade Zone Shanghai, P.R. China
   Manufacturer                        Sengled Co., Ltd.
                                       Room 201/15,Building 1, No.498, Guoshoujing Road, Pilot Free
   Manufacturer address
                                       Trade Zone Shanghai, P.R. China


General Technologies
   Model                               E21-N1EA
   SN                                  1929D500108
   Hardware Version                    V3
   Software Version                    V16
   Date of Testing:                    August 17, 2019 ~ August 18, 2019




TA Technology (Shanghai) Co., Ltd.                                                                                  Page 5 of 9
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


        MPE Test Report                                                                       Report No.: R1908A0493‐M1V1


3 Maximum conducted output power (measured) and antenna Gain

The numeric gain (G) of the antenna with a gain specified in dB is determined by
Numeric gain (G)=10^(antenna gain/10)



                                           Maximum Conducted Output
                                                                                     Antenna Gain
                Band                             Power (dBm)                                                 Numeric gain
                                                                                         (dBi)
                                              (dBm)                 (mW)
               Zigbee                          7.360                5.445                 1.500                  1.413




TA Technology (Shanghai) Co., Ltd.                                                                                  Page 6 of 9
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


        MPE Test Report                                                                       Report No.: R1908A0493‐M1V1


4 Test Result

    According to section 1.1310 of FCC 47 CFR Part 1, limits for maximum permissible exposure

    (MPE) are as following




Note1. Occupational/controlled limits apply in situations in which persons are exposed as a
consequence of their employment provided those persons are fully aware of the potential for
exposure and can exercise control over their exposure. Limits for occupational/controlled exposure
also apply in situations when an individual is transient through a location where occupational /
controlled limits apply provided he or she is made aware of the potential for exposure.

Note2: General population/uncontrolled exposures apply in situations in which the general public may
be exposed, or in which persons that are exposed as a consequence of their employment may not be
fully aware of the potential for exposure or can not exercise control over their exposure.




TA Technology (Shanghai) Co., Ltd.                                                                                  Page 7 of 9
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


        MPE Test Report                                                                       Report No.: R1908A0493‐M1V1
   The maximum permissible exposure for 1500~100,000MHz is 1.0.So


                        Band                                    The maximum permissible exposure


                       Zigbee                                                     1.0mW/cm2




TA Technology (Shanghai) Co., Ltd.                                                                                  Page 8 of 9
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


         MPE Test Report                                                                       Report No.: R1908A0493‐M1V1



 RF Exposure Calculations:
 The following information provides the minimum separation distance for the highest gain antenna
 provided. This calculation is based on the conducted power, considering maximum power and
 antenna gain. The formula shown in KDB 447498 D01 is used in the calculation.
 Equation from KDB 447498 D01 General RF Exposure Guidance v06 (10/23/2015) is:
                                                                       2
                                                       S= PG / 4∏R
                                                                            2
 Where: S = power density (in appropriate units, e.g. mW/cm )
        P = Time-average maximum tune up procedure (in appropriate units, e.g., mW)
        G = the numeric gain of the antenna
        R = distance to the center of radiation of the antenna (20 cm = limit for MPE)


                                                                Test Result            Limit Value
               Band                        PG (mW)                          2                      2          Conclusion
                                                                 (mW/cm )               (mW/cm )
              Zigbee                         7.691                  0.002                  1.000                  Pass
 Note: R = 20cm
      ∏= 3.1416


Note: For transmitters, minimum separation distance is 20cm, even if calculations indicate MPE
      distance is less.




 TA Technology (Shanghai) Co., Ltd.                                                                                  Page 9 of 9
 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.



Document Created: 2019-10-11 12:06:47
Document Modified: 2019-10-11 12:06:47

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC