Test Report

FCC ID: 2AGN8-E1EG7F

Test Report

Download: PDF
FCCID_4305232

                           EMC TEST REPORT


                       Applicant            Sengled Co., Ltd.

                       FCC ID               2AGN8-E1EG7F

                       Product              Sengled Smart Light Switch

                       Brand                sengled

                       Model                E1E-G7F

                       Report No.           R1904A0186-E1

                       Issue Date           May 8, 2019


TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in FCC
Code CFR47 Part15B (2018)/ ANSI C63.4 (2014). The test results show that the equipment tested is capable of
demonstrating compliance with the requirements as documented in this report.




              Performed by: Wei Liu/ Manager           Approved by: Guangchang Fan/ Director




               TA Technology (Shanghai) Co., Ltd.
                     No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China
                                        TEL: +86‐021‐50791141/2/3
                                     FAX: +86‐021‐50791141/2/3‐8000


                FCC EMC Test Report                                                                        Report No: R1904A0186-E1



                                                     Table of Contents
1  Test Laboratory............................................................................................................................... 4
 1.1    Notes of the Test Report ......................................................................................................... 4
 1.2    Test facility .............................................................................................................................. 4
 1.3    Testing Location ...................................................................................................................... 5
2 General Description of Equipment under Test ................................................................................ 6
 2.1    Client Information .................................................................................................................... 6
 2.2    General information ................................................................................................................. 6
 2.3    Applied Standards ................................................................................................................... 7
 2.4    Test Mode................................................................................................................................ 8
3 Test Case Results .......................................................................................................................... 9
 3.1    Radiated Emission .................................................................................................................. 9
 3.2    Conducted Emission ............................................................................................................. 15
4 Main Test Instrument .................................................................................................................... 17
ANNEX A: The EUT Appearance and Test Configuration................................................................. 18
 A.1 EUT Appearance ....................................................................................................................... 18
 A.2 Test Setup.................................................................................................................................. 20




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 2 of 20
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC EMC Test Report                                                          Report No: R1904A0186-E1




                                  Summary of measurement results
   Number              Test Case                        Clause in FCC Rules                              Conclusion
          1            Radiated Emission                FCC Part15.109, ANSI C63.4-2014                       PASS
          2            Conducted Emission               FCC Part15.107, ANSI C63.4-2014                         NA
                                      Test Date: April 23, 2019~ May 7, 2019




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 3 of 20
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC EMC Test Report                                                          Report No: R1904A0186-E1




1 Test Laboratory

1.1 Notes of the Test Report

This report shall not be reproduced in full or partial, without the written approval of TA technology
(shanghai) co., Ltd. The results documented in this report apply only to the tested sample, under the
conditions and modes of operation as described herein .Measurement Uncertainties were not taken
into account and are published for informational purposes only. This report is written to support
regulatory compliance of the applicable standards stated above.


1.2 Test facility

CNAS (accreditation number: L2264)
TA Technology (Shanghai) Co., Ltd. has obtained the accreditation of China National Accreditation
Service for Conformity Assessment (CNAS).
FCC (Designation number: CN1179, Test Firm Registration Number: 446626)
TA Technology (Shanghai) Co., Ltd. has been listed on the US Federal Communications Commission
list of test facilities recognized to perform electromagnetic emissions measurements.
IC (recognition number is 8510A)
TA Technology (Shanghai) Co., Ltd. has been listed by industry Canada to perform electromagnetic
emission measurement.
VCCI (recognition number is C-4595, T-2154, R-4113, G-10766)
TA Technology (Shanghai) Co., Ltd. has been listed by industry Japan to perform electromagnetic
emission measurement.
A2LA (Certificate Number: 3857.01)
TA Technology (Shanghai) Co., Ltd. has been listed by American Association for Laboratory
Accreditation to perform electromagnetic emission measurement.




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 4 of 20
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC EMC Test Report                                                          Report No: R1904A0186-E1


1.3 Testing Location


   Company:             TA Technology (Shanghai) Co., Ltd.

   Address:             No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China

   City:                Shanghai

   Post code:           201201
   Country:             P. R. China

   Contact:             Xu Kai

   Telephone:           +86-021-50791141/2/3

   Fax:                 +86-021-50791141/2/3-8000
   Website:             http://www.ta-shanghai.com

   E-mail:              xukai@ta-shanghai.com




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 5 of 20
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC EMC Test Report                                                          Report No: R1904A0186-E1




2 General Description of Equipment under Test

2.1 Client Information

   Applicant                             Sengled Co., Ltd
                                         Room 201/15,Building 1, No.498, Guoshoujing Road, Pilot Free
   Applicant address
                                         Trade Zone, Shanghai, P.R. China
   Manufacturer                          Sengled Co., Ltd
                                         Room 201/15,Building 1, No.498, Guoshoujing Road, Pilot Free
   Manufacturer address
                                         Trade Zone, Shanghai, P.R. China



2.2 General information

                                                    EUT Description
Device Type:                  Portable Device
Model:                        E1E-G7F
IMEI:                         /
HW Version:                   V1
SW Version:                   V3
Antenna Type:                 PCB Antenna
                                        Band                         Tx (MHz)                          Rx (MHz)
Frequency:
                              Zigbee                               2405 ~ 2480                       2405 ~ 2480
Modulation:                   Zigbee: O-QPSK
                                                     EUT Accessory
                              Manufacturer: Leqing City Huapai Electrical Science and Technology
Remote control base
                              Limited Company
                                               Auxiliary test equipment
                              PC Manufacturer: Dell
PC
                              Model: E5450 (SN : P48G001)
Note: The information of the EUT is declared by the manufacturer.




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 6 of 20
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC EMC Test Report                                                          Report No: R1904A0186-E1


2.3 Applied Standards

According to the specifications of the manufacturer, it must comply with the requirements of the
following standards:

Test standards
FCC Code CFR47 Part15B (2018)
ANSI C63.4 (2014)




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 7 of 20
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC EMC Test Report                                                          Report No: R1904A0186-E1


2.4 Test Mode

     Test Mode
     Mode 1                      EUT       +Idle




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 8 of 20
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC EMC Test Report                                                          Report No: R1904A0186-E1




3 Test Case Results

3.1 Radiated Emission

Ambient condition

                  Temperature                Relative humidity                         Pressure

                   24°C~26°C                     45%~50%                               102.5kPa



Methods of Measurement

The EUT is placed on a non-metallic table 0.8m above the horizontal metal reference ground plane.
The distance between EUT and receive antenna should be 3 meters. During the test, the EUT was
operating in its typical mode. The test method is according to ANSI C63.4-2014. Sweep the whole
frequency band through the range from 30MHz to the 5th harmonic of the carrier. During the test, the
height of receive antenna shall be moved from 1 to 4 meters, and the antenna shall be performed
under horizontal and vertical polarization. The turn table shall be rotated from 0 to 360 degrees for
detecting the maximum of radiated signal level.
The data of cable loss and antenna factor has been calibrated in full testing frequency range before
the testing. During the test, the EUT is worked at maximum output power.
Set the spectrum analyzer in the following:
Below 1GHz:
RBW=100 kHz / VBW=300 kHz / Sweep=AUTO
Above 1GHz:
(a) PEAK: RBW=1MHz / VBW=3MHz/ Sweep=AUTO
(b) AVERAGE: RBW=1MHz / VBW=3MHz / Sweep=AUTO

The radiated emission was measured in the following position: EUT stand-up position (Z axis),
lie-down position (X, Y axis). The worst emission was found in lie-down position (X axis) and the
worst case was recorded.

The EUT is only power supplied by battery.




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                     Page 9 of 20
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC EMC Test Report                                                          Report No: R1904A0186-E1

Test Setup



Below 1GHz




     Above 1GHz




Note: Area side:2.4mX3.6m

Antenna Tower meets ANSI C63.4 requirements for measurements above 1 GHz by keeping the
antenna aimed at the EUT during the antenna’s ascent/ descent along the antenna mast.




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 10 of 20
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC EMC Test Report                                                          Report No: R1904A0186-E1
Limits

                  Frequency                               Field Strength
                                                                                                   Detector
                    (MHz)                                   (dBμV/m)
                     30 -88                                     40.0                              Quasi-peak
                    88-216                                      43.5                              Quasi-peak
                   216 – 960                                    46.0                              Quasi-peak
                   960-1000                                     54.0                              Quasi-peak
     1000-5th harmonic of the highest                             54                                Average
   frequency or 40GHz,which is lower                              74                                  Peak



Measurement Uncertainty

The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution is
with the coverage factor k = 1.96.


                              Frequency                                           Uncertainty
                         30MHz~200MHz                                               4.02 dB
                        200MHz~1000MHz                                              3.28 dB
                           1GHz~18GHz                                               3.70 dB
                         18GHz~26.5GHz                                              5.78 dB
                         26.5GHz~40GHz                                              5.82 dB




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 11 of 20
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


                          FCC EMC Test Report                                                             Report No: R1904A0186-E1
Test Results

Sweep the whole frequency band through the range from 30MHz to the 5th harmonic of the carrier,
the Emissions in the frequency band 18GHz- 26.5GHz is more than 20dB below the limit are not
reported.

The following graphs display the maximum values of horizontal and vertical by software.
For above 1GHz, Blue trace uses the peak detection, Green trace uses the average detection.
                                                                   RE 30M-1GHz QP


                          100

                          90

                          80

                          70

                          60
         Level in dBμV/




                                                                                                                 FCC RE QP
                          50

                          40

                          30

                          20

                           10

                           0
                           30M            50   60      80   100M               200       300     400     500        800   1G
                                                                      Frequency in Hz


                                                    Radiated Emission from 30MHz to 1GHz



Frequency                       Quasi-Peak Height              Azimuth                          Correct         Margin   Limit
                                                  Polarization
  (MHz)                          (dBuV/m)   (cm)                (deg)                          Factor (dB)       (dB)  (dBuV/m)
36.496131                          17.3             125.0            V           22.0             -4.0            22.7         40.0
54.114375                          15.4             125.0            V           260.0            -7.1            24.6         40.0
99.846494                          13.6             220.0            H           319.0            -10.2           29.9         43.5
303.939500                         15.1             195.0            H           293.0            -8.6            30.9         46.0
354.735000                         18.1             209.0            V           51.0             -6.1            27.9         46.0
938.402750                         25.1             120.0            H           350.0             1.9            20.9         46.0
Remark: 1. Correction Factor = Antenna factor+ Insertion loss(cable loss+amplifier gain)
        2. Margin = Limit – Quasi-Peak




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 12 of 20
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC EMC Test Report                                                              Report No: R1904A0186-E1



                               110

                               100

                               90

                               80
                                                                                                     FCC RE PK(Class B)
                               70
              Level in dBμV/




                               60
                                                                                                     FCC RE AV(Class B)
                               50

                               40

                               30

                               20

                                10
                                 1G                     2G               3G        4G           5G       6       7    8G
                                                                 Frequency in Hz


                                               Radiated Emission from 1GHz to 8GHz

                                       Peak   Height              Azimuth  Correct    Margin   Limit
   Frequency                                         Polarization
                                     (dBuV/m) (cm)                 (deg)  Factor (dB)  (dB)  (dBuV/m)
     (MHz)
  1089.250000                          33.6    100.0         V          327.0           -10.6           40.4              74.0
  1394.625000                          35.3    100.0         H          135.0           -8.8            38.7              74.0
  1976.500000                          37.0    200.0         V          326.0           -6.5            37.0              74.0
  2813.875000                          39.2    200.0         V          105.0           -3.1            34.8              74.0
  3931.250000                          42.3    200.0         V          228.0           1.1             31.7              74.0
  5092.375000                          43.7    100.0         V          159.0           3.7             30.3              74.0


   Frequency                          Average Height              Azimuth  Correct    Margin   Limit
                                                     Polarization
     (MHz)                           (dBuV/m) (cm)                 (deg)  Factor (dB)  (dB)  (dBuV/m)
  1084.000000                          21.9    200.0         V           78.0           -10.6           32.1              54.0
  1393.750000                          23.1    200.0         V            0.0           -8.8            30.9              54.0
  1966.000000                          24.7    200.0         V          326.0           -6.6            29.3              54.0
  2826.125000                          26.4    200.0         V          105.0           -3.1            27.6              54.0
  3925.125000                          29.6    200.0         V            0.0           1.1             24.4              54.0
  5088.875000                          30.8    200.0         V          256.0           3.6             23.2              54.0




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 13 of 20
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


                           FCC EMC Test Report                                               Report No: R1904A0186-E1


                          110

                          100

                          90

                          80
                                                                                             FCC RE PK(Class B)
                          70
         Level in dBμV/




                          60
                                                                                             FCC RE AV(Class B)
                          50

                          40

                          30

                          20

                           10
                             8      9          10      11   12       13     14     15       16       17       18
                                                             Frequency in GHz



                                               Radiated Emission from 8GHz to 18GHz

                                                                                        Correct
    Frequency                       Peak   Height              Azimuth                              Margin   Limit
                                                  Polarization                          Factor
      (MHz)                       (dBuV/m) (cm)                 (deg)                                (dB)  (dBuV/m)
                                                                                         (dB)
   8347.500000                          48.8        200.0        V          90.0         11.0         25.2         74.0
   9115.000000                          51.7        200.0        V          8.0          13.7         22.3         74.0
  10678.750000                          50.9        200.0        V         132.0         12.0         23.1         74.0
  11958.750000                          51.2        100.0        V         310.0         12.7         22.8         74.0
  13721.250000                          53.8        100.0        V         296.0         15.6         20.2         74.0
  14955.000000                          56.2        200.0        H         324.0         18.0         17.8         74.0


                                                                                        Correct
    Frequency                      Average Height              Azimuth                              Margin   Limit
                                                  Polarization                          Factor
      (MHz)                       (dBuV/m) (cm)                 (deg)                                (dB)  (dBuV/m)
                                                                                         (dB)
   8346.250000                          36.6        100.0        V         227.0         11.0         17.4         54.0
   9082.500000                          39.3        200.0        H         269.0         13.3         14.7         54.0
  10670.000000                          38.8        200.0        V         132.0         11.9         15.2         54.0
  12030.000000                          38.4        200.0        V          0.0          12.7         15.6         54.0
  13735.000000                          41.3        200.0        V          77.0         15.8         12.7         54.0
  15025.000000                          45.0        200.0        V          8.0          18.1          9.0         54.0




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 14 of 20
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


               FCC EMC Test Report                                                         Report No: R1904A0186-E1




3.2 Conducted Emission

Ambient condition

                  Temperature                Relative humidity                         Pressure

                   24°C ~26°C                    50%~55%                               102.5kPa

Methods of Measurement

The EUT is placed on a non-metallic table of 80cm height above the horizontal metal reference
ground plane. During the test, the EUT was operating in its typical mode. The test method is
according to ANSI C63.4-2014. Connect the AC power line of the EUT to the L.I.S.N. Use EMI
receiver to detect the average and Quasi-peak value. RBW is set to 9 kHz, VBW is set to 30kHz. The
measurement result should include both L line and N line.


Test Setup




Note: Power Supply is AC Power source and it is used to change the voltage 120V/60Hz.

Limits

           Frequency                                            Conducted Limits(dBμV)
             (MHz)                              Quasi-peak                                      Average
                                                            *                                            *
            0.15 - 0.5                           66 to 56                                      56 to 46
              0.5 - 5                                56                                            46
              5 - 30                                 60                                            50
   *:
        Decreases with the logarithm of the frequency.

Measurement Uncertainty

The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution is
with the coverage factor k = 1.96. U= 2.57 dB.
TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 15 of 20
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.




              FCC EMC Test Report                                                          Report No: R1904A0186-E1




4 Main Test Instrument

                                                                            Serial        Calibration        Expiration
         Name                 Manufacturer                 Type
                                                                           Number            Date              Time
       Spectrum                                                           15195-01-
                                    R&S                   FSV40                            2018-05-20        2019-05-19
       Analyzer                                                              00
       EMI Test
                                    R&S                    ESCI             100948        2018-05-20        2019-05-19
       Receiver
    Trilog Antenna          SCHWARZBECK                VULB 9163          9163-201         2017-11-18        2019-11-17
    Horn Antenna                    R&S                   HF907             100126        2018-07-07         2020-07-06
    Standard Gain
                              ETS-Lindgren               3160-09          00102643         2018-06-20        2019-06-19
        Horn
       EMI Test
                                    R&S                    ESR              101667        2018-05-20         2019-05-19
       Receiver
          LISN                      R&S                  ENV216             101171        2016-12-16        2019-12-15
     Bore Sight
                                    ETS                   2171B           00058752               /                 /
    Antenna mast
    Test software                 EMC32                    R&S               9.26.0              /                 /




                                             *****END OF REPORT *****




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 17 of 20
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC EMC Test Report                                                          Report No: R1904A0186-E1


ANNEX A: The EUT Appearance and Test Configuration

A.1 EUT Appearance




                                                          a: EUT




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 18 of 20
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC EMC Test Report                                                          Report No: R1904A0186-E1




                                                b: Remote control base
                                           Picture 1 EUT and Accessory




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 19 of 20
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC EMC Test Report                                                          Report No: R1904A0186-E1
A.2 Test Setup




                                                       Below 1GHz




                                                      Above 1GHz
                                    Picture 2 Radiated Emission Test Setup




TA Technology (Shanghai) Co., Ltd.                              TA-MB-06-001E                                    Page 20 of 20
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.



Document Created: 2019-06-05 20:20:05
Document Modified: 2019-06-05 20:20:05

© 2025 FCC.report