Zigbee Test Report

FCC ID: 2AGN8-E1DG73

Test Report

Download: PDF
FCCID_4160366

                              RF TEST REPORT

                    Applicant             Sengled Co., Ltd.

                    FCC ID                2AGN8-E1DG73

                    Product               Smart Window & Door Sensor

                    Brand                 sengled

                    Marketing             Smart Window & Door Sensor

                    Model                 E1D-G73

                    Report No.            R1812A0593-R1V1

                    Issue Date            February 1, 2019



TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in FCC
CFR47 Part 15C (2018). The test results show that the equipment tested is capable of demonstrating
compliance with the requirements as documented in this report.




                     Performed by: Peng Tao                      Approved by: Kai Xu




              TA Technology (Shanghai) Co., Ltd.
                     No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China
                                        TEL: +86‐021‐50791141/2/3
                                     FAX: +86‐021‐50791141/2/3‐8000


              FCC RF Test Report                                                                           Report No: R1812A0593-R1V1




                                                 TABLE OF CONTENT

1.     Test Laboratory ............................................................................................................................ 4
     1.1. Notes of the test report ......................................................................................................... 4
     1.2. Test facility ........................................................................................................................... 4
     1.3. Testing Location ................................................................................................................... 5
2.      General Description of Equipment under Test.............................................................................. 6
3.      Applied Standards ........................................................................................................................ 7
4.      Test Configuration ........................................................................................................................ 8
5.     Test Case Results ........................................................................................................................ 9
     5.1. Maximum conducted output power ...................................................................................... 9
     5.2. 6dB Bandwidth ................................................................................................................... 11
     5.3. Band Edge ......................................................................................................................... 13
     5.4. Power Spectral Density ...................................................................................................... 15
     5.5. Spurious RF Conducted Emissions .................................................................................... 17
     5.6. Unwanted Emission ........................................................................................................... 19
     5.7. Conducted Emission .......................................................................................................... 31
6.      Main Test Instruments ................................................................................................................ 33
ANNEX A: EUT Appearance and Test Setup .................................................................................... 34
 A.1 EUT Appearance .................................................................................................................... 34
 A.2 Test Setup .............................................................................................................................. 36




TA Technology (Shanghai) Co., Ltd.                                     TA-MB-04-012R                             Page 2 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                             Report No: R1812A0593-R1V1




                                        Summary of measurement results

Number               Summary of measurements of results                              Clause in FCC rules                Verdict

     1         Maximum conducted output power                                     15.247(b)(3)                           PASS

     2         6 dB bandwidth                                                     15.247(a)(2)                           PASS

     3         Maximum power spectral density                                     15.247(e)                              PASS

     4         Band Edge                                                          15.247(d)                              PASS

     5         Spurious RF Conducted Emissions                                    15.247(d)                              PASS

     6         Unwanted Emissions                                                 15.247(d),15.205,15.209                PASS

     7         Conducted Emissions                                                15.207                                  NA

Date of Testing: December 26, 2018 ~ December 27, 2018




TA Technology (Shanghai) Co., Ltd.                                     TA-MB-04-012R                             Page 3 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                             Report No: R1812A0593-R1V1



1. Test Laboratory

1.1. Notes of the test report

This report shall not be reproduced in full or partial, without the written approval of TA technology

(shanghai) co., Ltd. The results documented in this report apply only to the tested sample, under

the conditions and modes of operation as described herein .Measurement Uncertainties were not

taken into account and are published for informational purposes only. This report is written to support

regulatory compliance of the applicable standards stated above.


1.2. Test facility

CNAS (accreditation number: L2264)
TA Technology (Shanghai) Co., Ltd. has obtained the accreditation of China National Accreditation
Service for Conformity Assessment (CNAS).
FCC (Designation number: CN1179, Test Firm Registration Number: 446626)
TA Technology (Shanghai) Co., Ltd. has been listed on the US Federal Communications
Commission list of test facilities recognized to perform electromagnetic emissions measurements.
IC (recognition number is 8510A)
TA Technology (Shanghai) Co., Ltd. has been listed by industry Canada to perform electromagnetic
emission measurement.
VCCI (recognition number is C-4595, T-2154, R-4113, G-10766)
TA Technology (Shanghai) Co., Ltd. has been listed by industry Japan to perform electromagnetic
emission measurement.
A2LA (Certificate Number: 3857.01)
TA Technology (Shanghai) Co., Ltd. has been listed by American Association for Laboratory
Accreditation to perform electromagnetic emission measurement.




TA Technology (Shanghai) Co., Ltd.                                     TA-MB-04-012R                             Page 4 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                             Report No: R1812A0593-R1V1


1.3. Testing Location


Company:              TA Technology (Shanghai) Co., Ltd.

Address:              No.145, Jintang Rd, Tangzhen Industry Park, Pudong

City:                 Shanghai

Post code:            201201
Country:              P. R. China

Contact:              Xu Kai

Telephone:            +86-021-50791141/2/3

Fax:                  +86-021-50791141/2/3-8000
Website:              http://www.ta-shanghai.com

E-mail:               xukai@ta-shanghai.com




TA Technology (Shanghai) Co., Ltd.                                     TA-MB-04-012R                             Page 5 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                             Report No: R1812A0593-R1V1



2. General Description of Equipment under Test

Client Information
   Applicant                             Sengled Co., Ltd.
                                         Room,Building 1, No.498, Guoshoujing Road, Pilot Free Trade
   Applicant address
                                         Zone, Shanghai, P.R. China
   Manufacturer                          Sengled Co., Ltd.
                                         Room,Building 1, No.498, Guoshoujing Road, Pilot Free Trade
   Manufacturer address
                                         Zone, Shanghai, P.R. China

General information
                                                     EUT Description
   Model:                                  E1D-G73
   SN:                                     1852D500215
   Hardware Version:                       V0.2
   Software Version:                       V0.2
   Power Supply:                           Battery
   Antenna Type:                           Internal Antenna
                                           A permanently attached antenna (meet with the standard FCC
   Antenna Connector:
                                           Part 15.203 requirement)
   Test Mode:                              Zigbee
   Modulation Type:                        Zigbee: O-QPSK
                                           1.45dBi for 2405MHz
   Antenna Gain:                           1.70dBi for 2440MHz
                                           1.57dBi for 2480MHz
   Directional Gain:                       NA
   additional beamforming gain:            NA
   Max. Conducted Power                    6.22 dBm
   Operating Frequency
                                           2405 ~ 2480 MHz
   Range(s)
   Note: The information of the EUT is declared by the manufacturer.




TA Technology (Shanghai) Co., Ltd.                                     TA-MB-04-012R                             Page 6 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                             Report No: R1812A0593-R1V1



3. Applied Standards

According to the specifications of the manufacturer, it must comply with the requirements of the
following standards:


FCC CFR47 Part 15C (2018) Radio Frequency Devices

ANSI C63.10 (2013)

KDB 558074 D01 DTS Meas Guidance v05




TA Technology (Shanghai) Co., Ltd.                                     TA-MB-04-012R                             Page 7 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                             Report No: R1812A0593-R1V1



4. Test Configuration

Test Mode
The EUT was programmed to be in continuously transmitting mode and the transmit duty cycle is not
less than 98%.

The EUT has been associated with peripherals and configuration operated in a manner tended to
maximize its emission characteristics in a typical application.

The radiated emission was measured in the following position: EUT stand-up position (Z axis),
lie-down position (X, Y axis). The worst emission was found in lie-down position (X axis) and the
worst case was recorded.


                                  Mode                      Channel               Frequency
                                                                11                 2405MHz
                                                                12                 2410MHz
                                                                13                 2415MHz
                                                                14                 2420MHz
                                                                15                 2425MHz
                                                                16                 2430MHz
                                                                17                 2435MHz
                                                                18                 2440MHz
                                  Zigbee
                                                                19                 2445MHz
                                                                20                 2450MHz
                                                                21                 2455MHz
                                                                22                 2460MHz
                                                                23                 2465MHz
                                                                24                 2470MHz
                                                                25                 2475MHz
                                                                26                 2480MHz




TA Technology (Shanghai) Co., Ltd.                                     TA-MB-04-012R                             Page 8 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                             Report No: R1812A0593-R1V1



5. Test Case Results

5.1. Maximum conducted output power

Ambient condition

               Temperature                  Relative humidity                           Pressure

                23°C ~25°C                      45%~50%                                 101.5kPa

Methods of Measurement

During the process of the testing, The EUT was connected to Spectrum Analyzer with a known loss.
The EUT is max power transmission with proper modulation. The Average detector is used. We use
Maximum Average Conducted Output Power Level Method in KDB 558074 D01 for this test.

Test Setup




Limits

Rule Part 15.247 (b) (3) specifies that " For systems using digital modulation in the 902–928 MHz,
2400–2483.5 MHz: 1 Watt.”


                      Average Output Power                                      ≤ 1W     (30dBm)




Measurement Uncertainty

The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution is
with the coverage factor k = 2, U= 0.44 dB.




TA Technology (Shanghai) Co., Ltd.                                     TA-MB-04-012R                             Page 9 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


          FCC RF Test Report                                                             Report No: R1812A0593-R1V1

Test Results



                                           Carrier          Average
                 Network                                                         Limit
                                         frequency        Output Power                        Conclusion
                Standards                                                       (dBm)
                                            (MHz)            (dBm)
                                            2405                 3.85              30             PASS
                   Zigbee                   2440                 4.80              30             PASS
                                            2480                 6.22              30             PASS




TA Technology (Shanghai) Co., Ltd.                                    TA-MB-04-012R                            Page 10 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


          FCC RF Test Report                                                             Report No: R1812A0593-R1V1


5.2. 6dB Bandwidth

Ambient condition

               Temperature                  Relative humidity                          Pressure

                23°C ~25°C                      45%~50%                                101.5kPa



Method of Measurement

The EUT was connected to the spectrum analyzer through an external attenuator (20dB) and a
known loss cable. RBW is set to 100 kHz; VBW is set to 300 kHz on spectrum analyzer.

Test Setup




Limits

Rule Part 15.247 (a) (2) specifies that “Systems using digital modulation techniques may operate in
the 902–928 MHz, 2400–2483.5 MHz bands. The minimum 6 dB bandwidth shall be at least 500
kHz.”


              minimum 6 dB bandwidth                                   ≥ 500 kHz




Measurement Uncertainty

The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution is
with the coverage factor k = 2, U= 936 Hz.




TA Technology (Shanghai) Co., Ltd.                                    TA-MB-04-012R                            Page 11 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


          FCC RF Test Report                                                             Report No: R1812A0593-R1V1


Test Results:
                                                         99%           Minimum 6 dB
     Network               Carrier frequency                                                    Limit
                                                      bandwidth         bandwidth                            Conclusion
    Standards                    (MHz)                                                          (kHz)
                                                        (MHz)              (MHz)

                                   2405                 2.4304               1.594               500             PASS

       Zigbee                      2440                 2.4537               1.613               500             PASS

                                   2480                 2.4547               1.627               500             PASS



      Zigbee, Carrier frequency (MHz): 2405                          Zigbee, Carrier frequency (MHz): 2440




      Zigbee, Carrier frequency (MHz): 2480




TA Technology (Shanghai) Co., Ltd.                                    TA-MB-04-012R                            Page 12 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


          FCC RF Test Report                                                             Report No: R1812A0593-R1V1


5.3. Band Edge

Ambient condition

               Temperature                  Relative humidity                          Pressure

                23°C ~25°C                      45%~50%                                101.5kPa



Method of Measurement

The EUT was connected to the spectrum analyzer through an external attenuator (20dB) and a
known loss cable the band edge of the lowest and highest channels were measured. The peak
detector is used and RBW is set to 100 kHz and VBW is set to 300 kHz on spectrum analyzer.
Spectrum analyzer plots are included on the following pages.


Test Setup




Limits

Rule Part 15.247(d) specifies that “In any 100 kHz bandwidth outside the frequency band in which
the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency
power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz
bandwidth within the band that contains the highest level of the desired power, based on either an
RF conducted or a radiated measurement, provided the transmitter demonstrates compliance with
the peak conducted power limits.” If the transmitter complies with the conducted power limits based
on the use of RMS averaging over a time interval, as permitted under paragraph (b)(3) of this section,
the attenuation required under this paragraph shall be 30 dB instead of 20 dB.”

Measurement Uncertainty

The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution is
with the coverage factor k = 1.96.
                            Frequency                                            Uncertainty

                           2GHz-3GHz                                               1.407 dB




TA Technology (Shanghai) Co., Ltd.                                    TA-MB-04-012R                            Page 13 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


          FCC RF Test Report                                                             Report No: R1812A0593-R1V1
Test Results: PASS
                  Zigbee, Channel No.: 11                                  Zigbee, Channel No.: 26




TA Technology (Shanghai) Co., Ltd.                                    TA-MB-04-012R                            Page 14 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


          FCC RF Test Report                                                             Report No: R1812A0593-R1V1


5.4. Power Spectral Density

Ambient condition

               Temperature                  Relative humidity                          Pressure

                23°C ~25°C                      45%~50%                                101.5kPa



Method of Measurement

The EUT was connected to the spectrum analyzer through an external attenuator (20dB) and a
known loss cable.
RBW is set to 3 kHz and VBW is set to 10 kHz for Zigbee on spectrum analyzer.
Set the span to 1.5 times the DTS channel bandwidth. Sweep time = auto couple. Trace mode = max
hold. The peak power spectral density is recorded.

Test setup




Limits

Rule Part 15.247(e) specifies that” For digitally modulated systems, the power spectral density
conducted from the intentional radiator to the antenna shall not be greater than 8 dBm in any 3 kHz
band during any time interval of continuous transmission. ‘’


                                Limits                                       ≤ 8 dBm / 3kHz



Measurement Uncertainty

The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution is
with the coverage factor k = 2, U= 0.75dB.




TA Technology (Shanghai) Co., Ltd.                                    TA-MB-04-012R                            Page 15 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


          FCC RF Test Report                                                              Report No: R1812A0593-R1V1
Test Results:

                                                      Power Spectral
                 Network              Channel                                     Limit
                                                         Density                            Conclusion
                Standards             Number                                   (dBm / 3kHz)
                                                       (dBm / 3kHz)

                                          11                 -20.53                   8              PASS

                  Zigbee                  18                 -19.19                   8              PASS

                                          26                 -17.80                   8              PASS



               Zigbee, Channel No.: 11                                        Zigbee, Channel No.: 18




               Zigbee, Channel No.: 26




TA Technology (Shanghai) Co., Ltd.                                    TA-MB-04-012R                            Page 16 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


          FCC RF Test Report                                                             Report No: R1812A0593-R1V1


5.5. Spurious RF Conducted Emissions

Ambient condition

               Temperature                  Relative humidity                          Pressure

                23°C ~25°C                      45%~50%                                101.5kPa

Method of Measurement

The EUT was connected to the spectrum analyzer with a known loss. The spectrum analyzer scans
from 30MHz to the 10th harmonic of the carrier. The peak detector is used. Set RBW to100kHz and
VBW to 300 kHz, Sweep is set to ATUO.
The test is in transmitting mode.




Limits

Rule Part 15.247(d) pacifies that “In any 100 kHz bandwidth outside the frequency band in which the
spread spectrum intentional radiator is operating, the radio frequency power that is produced by the
intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that
contains the highest level of the desired power.”
                                    Carrier frequency
      Network Standards                                        Reference value (dBm)                   Limit
                                          (MHz)
                                            2405                            0.49                       -29.51
               Zigbee                       2440                            1.45                       -28.55
                                            2480                           -1.56                       -31.56


Measurement Uncertainty

The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution is
with the coverage factor k = 1.96.
                         Frequency                                                   Uncertainty

                       100kHz-2GHz                                                    0.684 dB

                       2GHz-26GHz                                                     1.407 dB




TA Technology (Shanghai) Co., Ltd.                                    TA-MB-04-012R                            Page 17 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


          FCC RF Test Report                                                             Report No: R1812A0593-R1V1
 Test Results:
The signal beyond the limit is carrier.


                      Zigbee CH11                                                    Zigbee CH18




                      Zigbee CH26




TA Technology (Shanghai) Co., Ltd.                                    TA-MB-04-012R                            Page 18 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


          FCC RF Test Report                                                             Report No: R1812A0593-R1V1


5.6. Unwanted Emission

Ambient condition

               Temperature                  Relative humidity                          Pressure

                23°C ~25°C                      45%~50%                                102.5kPa

Method of Measurement

The test set-up was made in accordance to the general provisions of ANSI C63.10-2013.The
Equipment Under Test (EUT) was set up on a non-conductive table in the semi-anechoic chamber.
The test was performed at the distance of 3 m between the EUT and the receiving antenna.

The turntable shall be rotated from 0 to 360 degrees for detecting the maximum of radiated spurious
signal level. The measurements shall be repeated with orthogonal polarization of the test antenna.
RBW is set to 100kHz.The data of cable loss and antenna factor has been calibrated in full testing
frequency range before the testing. Sweep the whole frequency band through the range from 9kHz
to the 10th harmonic of the carrier, and the emissions less than 20 dB below the permissible value
are reported.
The radiated emissions measurements were made in a typical installation configuration.
Sweep the whole frequency band through the range from 9 kHz to the 10th harmonic of the carrier,
and the emissions less than 20 dB below the permissible value are reported.

Set the spectrum analyzer in the following:
(a) PEAK: RBW=VBW=3MHz / Sweep=AUTO
(b) AVERAGE: RBW=1MHz / VBW=3MHz / Sweep=AUTO
This setting method can refer to ANSI C63.10-2013.

During the test, below 30MHz, the center of the loop shall be 1 meters; above 30MHz, the height of
receive antenna shall be moved from 1 to 4 meters, and the antenna shall be performed under
horizontal and vertical polarization.
The data of cable loss and antenna factor has been calibrated in full testing frequency range before
the testing.
Set the spectrum analyzer in the following:
Below 1GHz (detector: Peak and Quasi-Peak)
RBW=100 kHz / VBW=300 kHz / Sweep=AUTO
Above 1GHz (detector: Peak):
(a) PEAK: RBW=1MHz VBW=3MHz/ Sweep=AUTO
(b) AVERAGE: RBW=1MHz / VBW=3MHz / Sweep=AUTO

The test is in transmitting mode.




TA Technology (Shanghai) Co., Ltd.                                    TA-MB-04-012R                            Page 19 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


          FCC RF Test Report                                                             Report No: R1812A0593-R1V1
Test setup
9KHz ~ 30MHz




30MHz ~ 1GHz




Above 1GHz




Note: Area side:2.4mX3.6m




TA Technology (Shanghai) Co., Ltd.                                    TA-MB-04-012R                            Page 20 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


          FCC RF Test Report                                                             Report No: R1812A0593-R1V1
Limits
Rule Part 15.247(d) specifies that “In addition, radiated emissions which fall in the restricted bands,
as defined in § 15.205(a), must also comply with the radiated emission limits specified in § 15.209(a)
(see § 15.205(c)).”

Limit in restricted band

Frequency of emission (MHz)                        Field strength(uV/m)                     Field strength(dBuV/m)

           0.009–0.490                                   2400/F(kHz)                                       /

           0.490–1.705                                   24000/F(kHz)                                      /

            1.705–30.0                                         30                                          /

               30-88                                           100                                        40

              88-216                                           150                                       43.5

              216-960                                          200                                        46

             Above960                                          500                                        54


§15.35(b)
There is also a limit on the radio frequency emissions, as measured using instrumentation with a
peak detector function, corresponding to 20 dB above the maximum permitted average limit.
Peak Limit=74 dBuV/m
Average Limit=54 dBuV/m

Spurious Radiated Emissions are permitted in any of the frequency bands listed below:




TA Technology (Shanghai) Co., Ltd.                                    TA-MB-04-012R                            Page 21 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


          FCC RF Test Report                                                             Report No: R1812A0593-R1V1



Measurement Uncertainty

The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution is
with the coverage factor k = 1.96.

                            Frequency                                            Uncertainty
                           9KHz-30MHz                                              3.55 dB
                         30MHz-200MHz                                              4.02 dB
                          200MHz-1GHz                                              3.28 dB
                           Above 1GHz                                              3.70 dB




TA Technology (Shanghai) Co., Ltd.                                    TA-MB-04-012R                            Page 22 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


                              FCC RF Test Report                                                                                                                                                                                               Report No: R1812A0593-R1V1
Test Results:
The signal beyond the limit is carrier.


                                     Zigbee-Channel 11: Peak                                                                                                                                             Zigbee-Channel 11: Average
                    110                                                                                                                                                                 110


                    100                                                                                                                                                                 100


                    90                                                                                                                                                                  90


                    80                                                                                                                                                                  80
                                                                                                                                                          FCC RE PK

                    70                                                                                                                                                                  70
                                                                                                           2.389980000 GHz
                                                                                                            52.059 dBμV/
   Level in dBμV/




                                                                                                                                                                       Level in dBμV/
                    60                                                                                                                                                                  60
                                                                                                                                                                                                                                                                                                                                FCC RE AV

                    50                                                                                                                                                                  50
                                                                                                                                                                                                                                                                                  2.389980000 GHz
                                                                                                                                                                                                                                                                                   37.266 dBμV/

                    40                                                                                                                                                                  40


                    30                                                                                                                                                                  30


                    20                                                                                                                                                                  20


                    10                                                                                                                                                                  10


                     0                                                                                                                                                                   0
                     2310   2320     2330          2340          2350     2360         2370         2380        2390          2400          2410     2420       2430                     2310   2320      2330          2340          2350     2360         2370         2380         2390          2400          2410     2420       2430

                                                                                 Frequency in MHz                                                                                                                                                     Frequency in MHz




                                     Zigbee-Channel 26: Peak                                                                                                                                             Zigbee-Channel 26: Average
                    110                                                                                                                                                                 110


                    100                                                                                                                                                                 100


                    90                                                                                                                                                                  90


                    80                                                                                                                                                                  80
                                                                                                                                                          FCC RE PK

                    70                                                                                                 2.483500000 GHz                                                  70
                                                                                                                        69.156 dBμV/
                                                                                                                                                                                                                                                                                         2.483500000 GHz
   Level in dBμV/




                                                                                                                                                                       Level in dBμV/




                    60                                                                                                                                                                  60                                                                                                52.064 dBμV/
                                                                                                                                                                                                                                                                                                                                FCC RE AV

                    50                                                                                                                                                                  50


                    40                                                                                                                                                                  40


                    30                                                                                                                                                                  30


                    20                                                                                                                                                                  20


                    10                                                                                                                                                                  10


                     0                                                                                                                                                                   0
                     2450     2455          2460          2465          2470           2475           2480             2485          2490          2495         2500                     2450     2455           2460          2465          2470           2475           2480              2485          2490          2495         2500

                                                                                 Frequency in MHz                                                                                                                                                     Frequency in MHz




TA Technology (Shanghai) Co., Ltd.                                    TA-MB-04-012R                            Page 23 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


          FCC RF Test Report                                                                         Report No: R1812A0593-R1V1
Test result
Sweep the whole frequency band through the range from 9kHz to the 10th harmonic of the carrier,
the Emissions in the frequency band 9kHz-30MHz and 18GHz-26.5GHz are more than 20dB below
the limit are not reported.

The following graphs display the maximum values of horizontal and vertical by software.
For above 1GHz, Blue trace uses the peak detection, Green trace uses the average detection.

During the test, the Radiates Emission from 30MHz to 1GHz was performed in all modes with all
channels, Zigbee, Channel 11 are selected as the worst condition. The test data of the worst-case
condition was recorded in this report.
Continuous TX mode:
                                                             RE 0.03-1GHz QP Class B


                            80

                            70

                            60
                                                                                                               FCC RE QP
                            50
           Level in dBμV/




                            40

                            30

                            20

                            10

                             0
                             30M          50   60      80   100M            200        300     400    500          800    1G

                                                                   Frequency in Hz


                                                Radiates Emission from 30MHz to 1GHz
                                                Reading                             Correct
Frequency                    Quasi-Peak                 Height              Azimuth         Margin   Limit
                                                 value         Polarization         Factor
  (MHz)                       (dBuV/m)                   (cm)                (deg)           (dB)  (dBuV/m)
                                               (dBuV/m)                              (dB)
35.410000                          13.7             -2.9      100.0          V                0.0           16.6         26.3     40.0
54.377500                          10.6             -3.3      100.0          V               324.0          13.9         29.4     40.0
109.938750                         11.0             -2.4      200.0          V                0.0           13.4         32.5     43.5
309.927500                         12.8             -2.9      200.0          H                0.0           15.7         33.2     46.0
548.912500                         19.5             -2.4      100.0          V                4.0           21.9         26.5     46.0
943.335000                         26.3             -0.7      200.0          V               138.0          27.0         19.7     46.0




TA Technology (Shanghai) Co., Ltd.                                    TA-MB-04-012R                            Page 24 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


          FCC RF Test Report                                                                Report No: R1812A0593-R1V1
Zigbee CH11
                                                     FCC RE 1G-3GHz PK+AV Class B


                            110
                            100


                            80                                                                       FCC RE PK
           Level in dBμV/




                            60                                                                       FCC RE AV


                            40


                            20


                             0
                             1000             1500                 2000              2500                     3000

                                                              Frequency in MHz


                                         Note: The signal beyond the limit is carrier.
                                          Radiates Emission from 1GHz to 3GHz
                                                     FCC RE 1G-18GHz PK+AV Class B


                            110
                            100


                            80                                                                          FCC RE PK
           Level in dBμV/




                            60                                                                          FCC RE AV


                            40


                            20


                             0
                                 3   4    6             8         10         12       14           16            18

                                                              Frequency in GHz


                                          Radiates Emission from 3GHz to 18GHz




TA Technology (Shanghai) Co., Ltd.                                    TA-MB-04-012R                            Page 25 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC RF Test Report                                                             Report No: R1812A0593-R1V1



                                                                               Reading        Correct
Frequency         Peak          Height                          Azimuth                                     Margin          Limit
                                            Polarization                        value         Factor
  (MHz)         (dBuV/m)         (cm)                            (deg)                                       (dB)         (dBuV/m)
                                                                              (dBuV/m)         (dB)
1166.000000         46.0         200.0             H              320.0          47.0           -1.0          28.0            74
1432.000000         47.0         200.0             H              166.0          46.9            0.1          27.0            74
1691.000000         48.2         100.0             V              343.0          46.5            1.7          25.8            74
2045.500000         50.3         100.0             V              289.0          46.9            3.4          23.7            74
2575.500000         52.5         200.0             H              352.0          46.7            5.8          21.5            74
2939.000000         53.1         200.0             V              152.0          46.7            6.4          20.9            74
    Remark: 1. Correction Factor = Antenna factor+ Insertion loss (cable loss + amplifier gain)

                                                                              Reading         Correct
Frequency        Average        Height                         Azimuth                                       Margin         Limit
                                            Polarization                       value          Factor
  (MHz)         (dBuV/m)         (cm)                           (deg)                                         (dB)        (dBuV/m)
                                                                             (dBuV/m)          (dB)

1137.500000         34.9         100.0             H             106.0           36.0            -1.1          19.1            54
1439.500000         35.5         200.0             H             224.0           35.3            0.2           18.5            54
1676.500000         36.7         100.0             H             106.0           35.1            1.6           17.3            54
2027.000000         38.5         200.0             H             272.0           35.2            3.3           15.5            54
2570.500000         40.4         200.0             V              56.0           34.6            5.8           13.6            54
2882.000000         41.3         200.0             H             253.0           34.9            6.4           12.7            54
    Remark: 1. Correction Factor = Antenna factor+ Insertion loss (cable loss + amplifier gain)




    TA Technology (Shanghai) Co., Ltd.                                    TA-MB-04-012R                            Page 26 of 37
    This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


          FCC RF Test Report                                                                Report No: R1812A0593-R1V1
Zigbee CH18
                                                     FCC RE 1G-3GHz PK+AV Class B


                            110
                            100


                            80                                                                       FCC RE PK
           Level in dBμV/




                            60                                                                       FCC RE AV


                            40


                            20


                             0
                             1000             1500                 2000              2500                     3000

                                                              Frequency in MHz


                                         Note: The signal beyond the limit is carrier.
                                          Radiates Emission from 1GHz to 3GHz
                                                     FCC RE 1G-18GHz PK+AV Class B


                            110
                            100


                            80                                                                          FCC RE PK
           Level in dBμV/




                            60                                                                          FCC RE AV


                            40


                            20


                             0
                                 3   4    6             8         10         12       14           16            18

                                                              Frequency in GHz


                                          Radiates Emission from 3GHz to 18GHz




TA Technology (Shanghai) Co., Ltd.                                    TA-MB-04-012R                            Page 27 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC RF Test Report                                                             Report No: R1812A0593-R1V1



                                                                               Reading        Correct
Frequency         Peak          Height                          Azimuth                                     Margin          Limit
                                            Polarization                        value         Factor
  (MHz)         (dBuV/m)         (cm)                            (deg)                                       (dB)         (dBuV/m)
                                                                              (dBuV/m)         (dB)
1169.500000         46.4         100.0             V              288.0          47.4           -1.0          27.6            74
1400.000000         47.4         200.0             V               0.0           47.4            0.0          26.6            74
1714.000000         47.8         200.0             H              357.0          46.1            1.7          26.2            74
2069.500000         49.8         100.0             H               0.0           46.2            3.6          24.2            74
2585.000000         51.9         100.0             H               0.0           46.0            5.9          22.1            74
2762.500000         52.4         200.0             H              98.0           46.2            6.2          21.6            74
    Remark: 1. Correction Factor = Antenna factor+ Insertion loss (cable loss + amplifier gain)

                                                                              Reading         Correct
Frequency        Average        Height                         Azimuth                                       Margin         Limit
                                            Polarization                       value          Factor
  (MHz)         (dBuV/m)         (cm)                           (deg)                                         (dB)        (dBuV/m)
                                                                             (dBuV/m)          (dB)

1190.500000         35.0         100.0             H               0.0           35.9            -0.9          19.0            54
1416.000000         36.0         100.0             V              52.0           35.9            0.1           18.0            54
1727.500000         36.9         200.0             H              68.0           35.1            1.8           17.1            54
2050.500000         38.4         100.0             H             260.0           34.9            3.5           15.6            54
2588.500000         40.6         100.0             V             259.0           34.7            5.9           13.4            54
2739.500000         41.3         100.0             V              63.0           35.2            6.1           12.7            54
    Remark: 1. Correction Factor = Antenna factor+ Insertion loss (cable loss + amplifier gain)




    TA Technology (Shanghai) Co., Ltd.                                    TA-MB-04-012R                            Page 28 of 37
    This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


          FCC RF Test Report                                                                Report No: R1812A0593-R1V1
Zigbee CH26


                                                     FCC RE 1G-3GHz PK+AV Class B


                            110
                            100


                            80                                                                       FCC RE PK
           Level in dBμV/




                            60                                                                       FCC RE AV


                            40


                            20


                             0
                             1000             1500                 2000              2500                     3000

                                                              Frequency in MHz


                                         Note: The signal beyond the limit is carrier.
                                          Radiates Emission from 1GHz to 3GHz
                                                     FCC RE 1G-18GHz PK+AV Class B


                            110
                            100


                            80                                                                          FCC RE PK
           Level in dBμV/




                            60                                                                          FCC RE AV


                            40


                            20


                             0
                                 3   4    6             8         10         12       14           16            18

                                                              Frequency in GHz


                                          Radiates Emission from 3GHz to 18GHz




TA Technology (Shanghai) Co., Ltd.                                    TA-MB-04-012R                            Page 29 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


              FCC RF Test Report                                                             Report No: R1812A0593-R1V1



                                                                               Reading        Correct
Frequency         Peak          Height                          Azimuth                                     Margin          Limit
                                            Polarization                        value         Factor
  (MHz)         (dBuV/m)         (cm)                            (deg)                                       (dB)         (dBuV/m)
                                                                              (dBuV/m)         (dB)
1167.500000         46.5         100.0             H              72.0           47.5           -1.0          27.5            74
1236.000000         47.3         100.0             V               0.0           48.1           -0.8          26.7            74
1464.500000         47.9         100.0             H              316.0          47.6            0.3          26.1            74
2066.000000         50.1         200.0             H               0.0           46.5            3.6          23.9            74
2679.500000         51.8         100.0             H              226.0          45.8            6.0          22.2            74
2998.500000         52.5         200.0             V              17.0           46.0            6.5          21.5            74
    Remark: 1. Correction Factor = Antenna factor+ Insertion loss (cable loss + amplifier gain)

                                                                              Reading         Correct
Frequency        Average        Height                         Azimuth                                       Margin         Limit
                                            Polarization                       value          Factor
  (MHz)         (dBuV/m)         (cm)                           (deg)                                         (dB)        (dBuV/m)
                                                                             (dBuV/m)          (dB)

1140.500000         35.1         200.0             V              45.0           36.2            -1.1          18.9            54
1440.500000         35.5         200.0             V              64.0           35.3            0.2           18.5            54
1707.000000         36.8         200.0             H               0.0           35.1            1.7           17.2            54
2055.000000         38.8         200.0             H             272.0           35.3            3.5           15.2            54
2724.500000         41.1         100.0             H              53.0           35.0            6.1           12.9            54
2983.000000         40.8         200.0             V               0.0           34.4            6.4           13.2            54
    Remark: 1. Correction Factor = Antenna factor+ Insertion loss (cable loss + amplifier gain)




    TA Technology (Shanghai) Co., Ltd.                                    TA-MB-04-012R                            Page 30 of 37
    This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                            Report No: R1812A0593-R1V1


5.7. Conducted Emission

Ambient condition

                   Temperature              Relative humidity                         Pressure

                    23°C ~25°C                    45%~50%                            101.5kPa

Methods of Measurement

The EUT is placed on a non-metallic table of 80cm height above the horizontal metal reference
ground plane. During the test, the EUT was operating in its typical mode. The test method is
according to ANSI C63.10-2013. Connect the AC power line of the EUT to the L.I.S.N. Use EMI
receiver to detect the average and Quasi-peak value. RBW is set to 9 kHz, VBW is set to 30kHz.
The measurement result should include both L line and N line.
The test is in transmitting mode.

Test Setup




Note: AC Power source is used to change the voltage 110V/60Hz.

Limits


       Frequency                                        Conducted Limits(dBμV)
         (MHz)                          Quasi-peak                                          Average

       0.15 - 0.5                        66 to 56 *                                         56 to 46*

         0.5 - 5                             56                                                46

         5 - 30                              60                                                50
  *:
       Decreases with the logarithm of the frequency.

Measurement Uncertainty

The assessed measurement uncertainty to ensure 95% confidence level for the normal distribution is
with the coverage factor k = 1.96, U= 2.69 dB.


TA Technology (Shanghai) Co., Ltd.                                    TA-MB-04-012R                            Page 31 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


          FCC RF Test Report                                                             Report No: R1812A0593-R1V1
Test Results:
The equipment doesn’t connect to public network, therefore this requirement does not apply.




TA Technology (Shanghai) Co., Ltd.                                    TA-MB-04-012R                            Page 32 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           FCC RF Test Report                                                             Report No: R1812A0593-R1V1



 6. Main Test Instruments

                                                                           Serial           Calibration         Expiration
       Name                   Manufacturer               Type
                                                                          Number               Date               Date
Spectrum Analyzer                   R&S                 FSV30              100815           2018-12-16          2019-12-15
EMI Test Receiver                   R&S                 ESCI               100948           2018-05-20         2019-05-19
   Loop Antenna             SCHWARZBECK              FMZB1519            1519-047           2017-09-26         2019-09-25
TRILOG Broadband
                              Schwarzbeck            VULB 9163           9163-201           2017-11-18          2019-11-17
     Antenna
 Double Ridged
 Waveguide Horn                     R&S                 HF907              100126           2018-07-07          2020-07-06
    Antenna
Standard Gain Horn            ETS-Lindgren             3160-09           00102643           2018-06-20          2020-06-19
EMI Test Receiver                   R&S                  ESR               101667           2018-05-20         2019-05-19
        LISN                        R&S                ENV216              101171           2016-12-16          2019-12-15
Spectrum Analyzer                 Agilent              N9010A          MY47191109           2018-05-20          2019-05-19
     RF Cable                     Agilent            SMA 15cm               0001            2018-12-16          2019-03-15
      Software                      R&S                EMC32               9.26.0                  /                  /



                                             *****END OF REPORT *****




 TA Technology (Shanghai) Co., Ltd.                                    TA-MB-04-012R                            Page 33 of 37
 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


          FCC RF Test Report                                                             Report No: R1812A0593-R1V1



ANNEX A: EUT Appearance and Test Setup

  A.1 EUT Appearance




                                                       Front Side




                                                       Back Side
                                                        Part 1


TA Technology (Shanghai) Co., Ltd.                                    TA-MB-04-012R                            Page 34 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


          FCC RF Test Report                                                             Report No: R1812A0593-R1V1




                                                       Front Side




                                                       Back Side
                                                        Part 2
                                                    Picture 1 EUT




TA Technology (Shanghai) Co., Ltd.                                    TA-MB-04-012R                            Page 35 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


          FCC RF Test Report                                                             Report No: R1812A0593-R1V1


  A.2 Test Setup




                                                     9KHz-30MHz




                                                     30MHz-1GHz



TA Technology (Shanghai) Co., Ltd.                                    TA-MB-04-012R                            Page 36 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


          FCC RF Test Report                                                             Report No: R1812A0593-R1V1




                                                      Above 1GHz
                                   Picture 2 Radiated Emission Test Setup




TA Technology (Shanghai) Co., Ltd.                                    TA-MB-04-012R                            Page 37 of 37
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.



Document Created: 2019-03-21 13:54:49
Document Modified: 2019-03-21 13:54:49

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC