18_TP007 RFExp r1

FCC ID: 2AGLG-TP007

RF Exposure Info

Download: PDF
FCCID_4369166

Report No.: SZAWW190704002-02            FCC ID: 2AGLG-TP007            Page 1 of 14




                    FCC TEST REPORT

                           DONGGUAN TOGRAN ELECTRONICS TECHNOLOGY
    Client Name        :
                           CO.,LTD.

                           262 shidan Rd.,3rd industrial Area, Juzhou, Shijie Town,
    Address            :
                           Dongguan city, China


    Product Name       : Wireless charge PAD


    Date               : Jul. 22, 2019




    Shenzhen Anbotek Compliance Laboratory Limited




                                                                       Code:AB-RF-05-a


Report No.: SZAWW190704002-02                                                     FCC ID: 2AGLG-TP007                                      Page 2 of 14


                                                                    Contents
1. General Information...............................................................................................................................................4
    1.1. Client Information....................................................................................................................................... 4
    1.2. Description of Device (EUT).....................................................................................................................4
    1.3. Auxiliary Equipment Used During Test................................................................................................... 5
    1.4. Test Equipment List....................................................................................................................................5
    1.5. Measurement Uncertainty.........................................................................................................................5
    1.6. Description of Test Facility........................................................................................................................ 5
2. Measurement and Result..................................................................................................................................... 7
    2.1. Requirements..............................................................................................................................................7
    2.2. Test Setup....................................................................................................................................................8
    2.3. Test Procedure............................................................................................................................................8
    2.4. Test Result................................................................................................................................................... 8
    2.4.1. Equipment Approval Considerations item 5.b of KDB 680106 D01 v03....................................... 8
   2.4.2. Environmental evaluation and exposure limit according to FCC CFR 47 part 1, 1.1307(b),
   1.1310................................................................................................................................................................ 10
APPENDIX I -- TEST SETUP PHOTOGRAPH...................................................................................................12




                                                                                                                                         Code:AB-RF-05-a


Report No.: SZAWW190704002-02                    FCC ID: 2AGLG-TP007                 Page 3 of 14



                                  TEST REPORT
Applicant            :   DONGGUAN TOGRAN ELECTRONICS TECHNOLOGY CO.,LTD.
Manufacturer         :   DONGGUAN TOGRAN ELECTRONICS TECHNOLOGY CO.,LTD.
Product Name         :   Wireless charge PAD
Model No.            :   TP007
Trade Mark           :   N.A.
                         Input: 5V  1A
Rating(s)            :
                         Output: 5W



Test Standard(s)     :   FCC Part 1.1310, 1.1307(b)
Test Method(s)       :   KDB680106 D01 RF Exposure Wireless Charging Apps v03

The device described above is tested by Shenzhen Anbotek Compliance Laboratory Limited to
determine the maximum emission levels emanating from the device and the severe levels of the device
can endure and its performance criterion. The measurement results are contained in this test report and
Shenzhen Anbotek Compliance Laboratory Limited is assumed full of responsibility for the accuracy
and completeness of these measurements. Also, this report shows that the EUT (Equipment Under
Test) is technically compliant with the FCC Part 1.1307 & KDB680106 D01 requirements.

This report applies to above tested sample only and shall not be reproduced in part without written
approval of Shenzhen Anbotek Compliance Laboratory Limited.


Date of Receipt                                                 Jul. 04, 2019
Date of Test                                                  Jul. 04~15, 2019



Prepared By
                                                            (Engineer / Dolly Mo)



Reviewer
                                                         (Supervisor / Snowy Meng)




Approved & Authorized Signer
                                                           (Manager / Sally Zhang)


                                                                                    Code:AB-RF-05-a


Report No.: SZAWW190704002-02                    FCC ID: 2AGLG-TP007                  Page 4 of 14


1. General Information
1.1. Client Information

Applicant            :   DONGGUAN TOGRAN ELECTRONICS TECHNOLOGY CO.,LTD.

                         262 shidan Rd.,3rd industrial Area, Juzhou, Shijie Town, Dongguan city,
Address              :
                         China
Manufacturer         :   DONGGUAN TOGRAN ELECTRONICS TECHNOLOGY CO.,LTD.
Address                  262 shidan Rd.,3rd industrial Area, Juzhou, Shijie Town, Dongguan city,
                     :
                         China
Factory              :   DONGGUAN TOGRAN ELECTRONICS TECHNOLOGY CO.,LTD.
Address                  262 shidan Rd.,3rd industrial Area, Juzhou, Shijie Town, Dongguan city,
                     :
                         China


1.2. Description of Device (EUT)

Product Name         : Wireless charge PAD

Model No.            :   TP007

Trade Mark           :   N.A.

Test Power Supply    :   AC 120V, 60Hz for adapter

Test Sample No.      :   1-2-1(Normal Sample), 1-2-2(Engineering Sample)

                         Operation Frequency:           110.1~205KHz

Product                  Modulation Type:               PWM
                     :
Description              Antenna Type:                  Inductive loop coil Antenna

                         Antenna Gain(Peak):            0 dBi

Remark: 1) For a more detailed features description, please refer to the manufacturer’s specifications
           or the User’s Manual.




                                                                                  Code:AB-RF-05-a


Report No.: SZAWW190704002-02                         FCC ID: 2AGLG-TP007                   Page 5 of 14


1.3. Auxiliary Equipment Used During Test
 Adapter                :   Manufacturer: ZTE
                            M/N: STC-A2050I1000USBA-C
                            S/N: 201202102100876
                            Input: 100-240V~ 50/60Hz, 0.3A
                            Output: DC 5V, 1000mA


 Mobile Phone           :   iPhone 8

1.4. Test Equipment List
 Item       Equipment          Manufacturer       Model No.        Serial No.      Last Cal.     Cal. Interval
  1     Magnetic field meter      NARDA              ELT-400        423623      Dec. 24, 2018       1 Year
  2        E-Field Probe           Narda             EF0391         Q15221      Nov.17, 2017        3 Year
  3        H-Field Probe           Narda             HF3061         Q15835      Nov.17, 2017        3 Year


1.5. Measurement Uncertainty
 Radiation Uncertainty             :   Ur = 3.9 dB (Horizontal)
                                       Ur = 3.8 dB (Vertical)


 Conduction Uncertainty            :   Uc = 3.4 dB


1.6. Description of Test Facility
The test facility is recognized, certified, or accredited by the following organizations:

FCC-Registration No.: 184111
Shenzhen Anbotek Compliance Laboratory Limited, EMC Laboratory has been registed and fully
described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter
from the FCC is maintained in our files. Registration No. 184111, September 30, 2018.

ISED-Registration No.: 8058A-1
Shenzhen Anbotek Compliance Laboratory Limited, EMC Laboratory has been registered and fully
described in a report filed with the (ISED) Innovation, Science and Economic Development Canada. The
acceptance letter from the ISED is maintained in our files. Registration 8058A-1, March 07, 2019.

Test Location
Shenzhen Anbotek Compliance Laboratory Limited.

                                                                                            Code:AB-RF-05-a


Report No.: SZAWW190704002-02                FCC ID: 2AGLG-TP007             Page 6 of 14

1/F, Building D, Sogood Science and Technology Park, Sanwei community, Hangcheng Street, Bao'an
District, Shenzhen, Guangdong, China. 518102




                                                                            Code:AB-RF-05-a


Report No.: SZAWW190704002-02                        FCC ID: 2AGLG-TP007              Page 7 of 14


2. Measurement and Result
2.1. Requirements
According to the item 5.b) of KDB 680106 D01v03:
Inductive wireless power transfer applications that meet all of the following requirements are excluded
from submitting an RF exposure evaluation.
1) Power transfer frequency is less that 1 MHz
2) Output power from each primary coil is less than or equal to 15 watts.
3) The transfer system includes only single primary and secondary coils. This includes charging systems
that may have multiple primary coils and clients that are able to detect and allow coupling only between
individual pairs of coils
4) Client device is inserted in or placed directly in contact with the transmitter
5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion)
6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface
from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit.

                            Limits For Maximum Permissible Exposure (MPE)




                                                                                     Code:AB-RF-05-a


Report No.: SZAWW190704002-02                        FCC ID: 2AGLG-TP007                   Page 8 of 14

2.2. Test Setup



                               20cm




                                                   15 cm




Note: Measurements should be made at 15 cm surrounding the EUT and 20cm above the top surface of
the EUT.


2.3. Test Procedure
1) The RF exposure test was performed in anechoic chamber.
2) The measurement probe was placed at required test distance which is between the edge of the
charger and the geometric center of probe.
3) The highest emission level was recorded and compared with limit as soon as measurement of each
points
(A, B, C, D, E) were completed.(A is the right, B is the back, C is the left, D is the front, and E is the top.)
4) The EUT was measured according to the dictates of KDB 680106 D01 v03.
Remark;
The EUT’s test position A, B, C, D and E is valid for the E and H field measurements.


2.4. Test Result
2.4.1. Equipment Approval Considerations item 5.b of KDB 680106 D01 v03.
1) Power transfer frequency is less that 1 MHz
 - The device operate in the frequency range 110.1~205KHz


2) Output power from each primary coil is less than 15 watts
  - The maximum output power of the primary coil is 5W.

                                                                                         Code:AB-RF-05-a


Report No.: SZAWW190704002-02                        FCC ID: 2AGLG-TP007              Page 9 of 14



3) The transfer system includes only single primary and secondary coils. This includes charging systems
that may have multiple primary coils and clients that are able to detect and allow coupling only between
individual pairs of coils
 - The transfer system including a charging system with only single primary coils is to detect and allow
 only between individual pairs of coils.


4) Client device is inserted in or placed directly in contact with the transmitter
 - Client device is placed directly in contact with the transmitter.


5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion)
  - The EUT is a Mobile Power Pack with Wireless Charger

6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface
from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit.
   - Conducted the measurement with the required distance and the test results please refer to the
section 2.4.2




                                                                                     Code:AB-RF-05-a


Report No.: SZAWW190704002-02                 FCC ID: 2AGLG-TP007                     Page 10 of 14


2.4.2. Environmental evaluation and exposure limit according to FCC CFR 47 part 1,
1.1307(b), 1.1310


   Temperature:              23.4°C               Relative Humidity:                  55%
     Pressure:             1012 hPa                     Test Voltage:       AC 120V, 60Hz for adapter


E-Field Strength at 15 cm surrounding the EUT and 20cm above the top surface of the EUT
           Frequency    Test       Test       Test         Test          Test      Reference   Limits
 Battery
             Range     Position   Position   Position     Position      Position     Limit      Test
 power
             (KHz)       A          B          C            D             E          (V/m)     (V/m)


  1%       110.1~205    0.29       0.34       0.26          0.47         0.98        307        614




  50%      110.1~205    1.52       1.31       1.69          1.04          1.5        307        614




  99%      110.1~205    2.34       2.27       2.02          2.80         2.44        307        614




Stand-by   110.1~205    0.15       0.54       0.69          0.53         0.82        307        614




                                                                                     Code:AB-RF-05-a


Report No.: SZAWW190704002-02                 FCC ID: 2AGLG-TP007               Page 11 of 14



H-Field Strength at 15 cm surrounding the EUT and 20cm above the top surface of the EUT
           Frequency    Test       Test       Test       Test       Test      Reference   Limits
 Battery
             Range     Position   Position   Position   Position   Position     Limit      Test
 power
             (KHz)       A          B          C          D          E          (A/m)     (A/m)


  1%       110.1~205    0.047      0.042      0.055      0.030      0.053       0.815     1.63




  50%      110.1~205    0.24       0.53       0.46       0.33       0.46        0.815     1.63




  99%      110.1~205    0.36       0.35       0.32       0.29       0.24        0.815     1.63




Stand-by   110.1~205    0.30       0.16       0.37       0.41       0.22        0.815     1.63




                                                                               Code:AB-RF-05-a


Report No.: SZAWW190704002-02             FCC ID: 2AGLG-TP007   Page 12 of 14


APPENDIX I -- TEST SETUP PHOTOGRAPH
                                Photo of MPE Measurement




                                                                Code:AB-RF-05-a


Anbotek BegfoJ
seAnbotek Testing




Shenzhen Anbotek Compliance Laboratory Limited
Address: 1/F, Building:—D, Sogood Science and Technology Park, SanweiCommunity,   @ Hotline
Hangcheng Street, Bac‘an District, Shenzhen, Guangdong, China.                    °/ 400—003—0500
Tel:(86)755—26066440     Fax:(86)755—26014772     Email:service @anbotek.com      www.anbotek.com


Anbotek BegfoJ
eb eELG4)          Anbotek Testing




Shenzhen Anbotek Compliance Laboratory Limited
Address: 1/F, Building:—D, Sogood Science and Technology Park, SanweiCommunity,   @ Hotline
Hangcheng Street, Bac‘an District, Shenzhen, Guangdong, China.                    °/ 400—003—0500
Tel:(86)755—26066440     Fax:(86)755—26014772     Email:service @anbotek.com      www.anbotek.com



Document Created: 2019-07-24 06:06:19
Document Modified: 2019-07-24 06:06:19

© 2024 FCC.report