Report No.: SZAWW190704002-01               FCC ID: 2AGLG-TP007             Page 1 of 27




                     FCC TEST REPORT

                            DONGGUAN TOGRAN ELECTRONICS TECHNOLOGY
    Client Name         :
                            CO.,LTD.

                            262 Shidan Rd., 3rd Inddustrial Area, Juzhou, Shijie
    Address             :
                            Town, Dongguan city, China


    Product Name        : Wireless charge PAD


    Date                : Jul. 22, 2019




    Shenzhen Anbotek Compliance Laboratory Limited




                                                                        Code:AB-RF-05-a


Report No.: SZAWW190704002-01                                                        FCC ID: 2AGLG-TP007                                        Page 2 of 27

                                                                   Contents
1. General Information...............................................................................................................................................4
     1.1. Client Information....................................................................................................................................... 4
     1.2. Description of Device (EUT).....................................................................................................................4
     1.3. Auxiliary Equipment Used During Test................................................................................................... 4
     1.4. Description of Test Modes........................................................................................................................ 5
     1.5. Description Of Test Setup......................................................................................................................... 6
     1.6. Test Equipment List....................................................................................................................................7
     1.7. Measurement Uncertainty.........................................................................................................................8
     1.8. Description of Test Facility........................................................................................................................ 8
2. Summary of Test Results..................................................................................................................................... 9
3. Conducted Emission Test...................................................................................................................................10
     3.1. Test Standard and Limit.......................................................................................................................... 10
     3.2. Test Setup..................................................................................................................................................10
     3.3. Test Procedure..........................................................................................................................................10
     3.4. Test Data....................................................................................................................................................10
4. Radiation Spurious Emission and Band Edge................................................................................................13
     4.1. Test Standard and Limit.......................................................................................................................... 13
     4.2. Test Setup..................................................................................................................................................13
     4.3. Test Procedure..........................................................................................................................................14
     4.4. Test Data....................................................................................................................................................15
5. Antenna Requirement......................................................................................................................................... 19
     5.1. Test Standard and Requirement............................................................................................................19
     5.2. Antenna Connected Construction..........................................................................................................19
APPENDIX I -- TEST SETUP PHOTOGRAPH...................................................................................................20
APPENDIX II -- EXTERNAL PHOTOGRAPH..................................................................................................... 22
APPENDIX III -- INTERNAL PHOTOGRAPH..................................................................................................... 26




                                                                                                                                        Code:AB-RF-05-a


Report No.: SZAWW190704002-01                      FCC ID: 2AGLG-TP007                  Page 3 of 27


                                  TEST REPORT
Applicant            : DONGGUAN TOGRAN ELECTRONICS TECHNOLOGY CO.,LTD.

Manufacturer         : DONGGUAN TOGRAN ELECTRONICS TECHNOLOGY CO.,LTD.

Product Name         : Wireless charge PAD

Model No.            : TP007

Trade Mark           : N.A.
                         Input: 5V  1A
Rating(s)            :
                         Output: 5W



Test Standard(s)     :   FCC Part15 Subpart C 2018, Paragraph 15.209
Test Method(s)       :   ANSI C63.10: 2013

The device described above is tested by Shenzhen Anbotek Compliance Laboratory Limited to
determine the maximum emission levels emanating from the device and the severe levels of the device
can endure and its performance criterion. The measurement results are contained in this test report and
Shenzhen Anbotek Compliance Laboratory Limited is assumed full of responsibility for the accuracy
and completeness of these measurements. Also, this report shows that the EUT (Equipment Under
Test) is technically compliant with the FCC Part 15 Subpart C requirements.

This report applies to above tested sample only and shall not be reproduced in part without written
approval of Shenzhen Anbotek Compliance Laboratory Limited.

Date of Receipt                                                 Jul. 04, 2019
Date of Test                                                  Jul. 04~15, 2019



Prepared By
                                                            (Engineer / Dolly Mo)



Reviewer
                                                         (Supervisor / Snowy Meng)




Approved & Authorized Signer
                                                           (Manager / Sally Zhang)


                                                                                    Code:AB-RF-05-a


Report No.: SZAWW190704002-01                      FCC ID: 2AGLG-TP007                 Page 4 of 27

1. General Information
1.1. Client Information
Applicant            :   DONGGUAN TOGRAN ELECTRONICS TECHNOLOGY CO.,LTD.
                         262 Shidan Rd., 3rd Inddustrial Area, Juzhou, Shijie Town, Dongguan city,
Address              :
                         China
Manufacturer         :   DONGGUAN TOGRAN ELECTRONICS TECHNOLOGY CO.,LTD.
Address                  262 Shidan Rd., 3rd Inddustrial Area, Juzhou, Shijie Town, Dongguan city,
                     :
                         China
Factory              :   DONGGUAN TOGRAN ELECTRONICS TECHNOLOGY CO.,LTD.
Address                  262 Shidan Rd., 3rd Inddustrial Area, Juzhou, Shijie Town, Dongguan city,
                     :
                         China


1.2. Description of Device (EUT)
Product Name         :   Wireless charge PAD
Model No.            :   TP007
Trade Mark           :   N.A.
Test Power Supply    :   AC 120V, 60Hz for adapter
Test Sample No.      :   1-2-1(Normal Sample), 1-2-2(Engineering Sample)
                         Operation Frequency:           110.1~205KHz

Product                  Modulation Type:               PWM
                     :
Description              Antenna Type:                  Inductive loop coil Antenna
                         Antenna Gain(Peak):            0 dBi
Remark: 1) For a more detailed features description, please refer to the manufacturer’s specifications
           or the User’s Manual.


1.3. Auxiliary Equipment Used During Test
Adapter              :   Manufacturer: ZTE
                         M/N: STC-A2050I1000USBA-C
                         S/N: 201202102100876
                         Input: 100-240V~ 50/60Hz, 0.3A
                         Output: DC 5V, 1000mA


Mobile Phone         :   iPhone 8


                                                                                  Code:AB-RF-05-a


Report No.: SZAWW190704002-01                          FCC ID: 2AGLG-TP007                   Page 5 of 27
1.4. Description of Test Modes
To investigate the maximum EMI emission characteristics generates from EUT, the test system was
pre-scanning tested base on the consideration of following EUT operation mode or test configuration
mode which possible have effect on EMI emission level. Each of these EUT operation mode(s) or test
configuration mode(s) mentioned above was evaluated respectively.


             Pretest Mode                                      Description
                 Mode 1                            Full load, Wireless charger module


                                         For Conducted Emission
            Final Test Mode                                    Description
                 Mode 1                            Full load, Wireless charger module


                                          For Radiated Emission
            Final Test Mode                                    Description
                 Mode 1                            Full load, Wireless charger module



Note: (1)Test channel is 0.1590MHz.
     (2)All the situation(full load, half load and empty load) has been tested,only the worst situation (full
         load) was recorded in the report.




                                                                                        Code:AB-RF-05-a


Report No.: SZAWW190704002-01                    FCC ID: 2AGLG-TP007         Page 6 of 27
1.5. Description Of Test Setup



  CE
                                                       USB


                                                                        AC Line
                                           E-1                  E-2
                                           EUT                Adapter             LISN

                                     Mobile Phone
0.8m




        Table
       Table

                                    1.5m




  RE

                                    USB


                                                                        AC Line
                         E-1                       E-2
                         EUT                     Adapter

                     Mobile Phone
0.8m




        Table
       Table

                                    1.5m




                                                                        Code:AB-RF-05-a


Report No.: SZAWW190704002-01                    FCC ID: 2AGLG-TP007               Page 7 of 27
1.6. Test Equipment List
                                                                                             Cal.
Item       Equipment         Manufacturer      Model No.      Serial No.      Last Cal.
                                                                                            Interval
            L.I.S.N.
 1.      Artificial Mains   Rohde & Schwarz     ENV216         100055       Nov. 26, 2018   1 Year
            Network
 2.    EMI Test Receiver    Rohde & Schwarz     ESPI3          101604       Nov. 05, 2018   1 Year
                              Compliance
 3.     RF Switching Unit                      RSU-M2          38303        Nov. 05, 2018   1 Year
                               Direction
 4.    Spectrum Analysis        Agilent         E4407B       US39390582     Nov. 05, 2018   1 Year
         MAX Spectrum
 5.                             Agilent         N9020A       MY51170037     Nov. 05, 2018   1 Year
            Analysis
                                              BK1G18G30
 6.       Preamplifier      SKET Electronic                   KD17503       Nov. 05, 2018   1 Year
                                                  D
       Double Ridged Horn     Instruments
 7.                                            GTH-0118        351600       Nov. 19, 2018   1 Year
            Antenna           corporation
        Bilog Broadband
 8.                          Schwarzbeck      VULB9163      VULB 9163-289   Nov. 19, 2018   1 Year
            Antenna
 9.      Loop Antenna        Schwarzbeck      FMZB1519B        00053        Nov. 19, 2018   1 Year
                                              LB-180400-K
 10.     Horn Antenna           A-INFO                       J211060628     Nov. 20, 2018   1 Year
                                                  F
 11.      Pre-amplifier        SONOMA            310N          186860       Nov. 05, 2018   1 Year
       EMI Test Software
 12.                           SHURPLE           N/A             N/A            N/A          N/A
            EZ-EMC
         RF Test Control
 13.                           YIHENG           YH3000        2017430       Nov. 05, 2018   1 Year
            System
 14.     Power Sensor           DAER          RPR3006W      15I00041SN045   Nov. 05, 2018   1 Year

 15.     Power Sensor           DAER          RPR3006W      15I00041SN046   Nov. 05, 2018   1 Year
         MXA Spectrum
 16.                            Agilent         N9020A       MY51170037     Nov. 05, 2018   1 Year
            Analysis
         MXG RF Vector
 17.                            Agilent         N5182A       MY48180656     Nov. 05, 2018   1 Year
        Signal Generator
 18.    Signal Generator        Agilent         E4421B       MY41000743     Nov. 05, 2018   1 Year

 19.    DC Power Supply           LW          TPR-6420D        374470       Oct. 31, 2018   1 Year
            Constant
                                              ZJ-KHWS80
 20.      Temperature         ZHONGJIAN                          N/A        Nov. 01, 2018   1 Year
                                                  B
       Humidity Chamber



                                                                              Code:AB-RF-05-a


Report No.: SZAWW190704002-01                          FCC ID: 2AGLG-TP007                      Page 8 of 27


1.7. Measurement Uncertainty
 Radiation Uncertainty             :   Ur = 3.9 dB (Horizontal)
                                       Ur = 3.8 dB (Vertical)


 Conduction Uncertainty            :   Uc = 3.4 dB


1.8. Description of Test Facility
The test facility is recognized, certified, or accredited by the following organizations:

FCC-Registration No.: 184111
Shenzhen Anbotek Compliance Laboratory Limited, EMC Laboratory has been registed and fully
described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter
from the FCC is maintained in our files. Registration No. 184111, September 30, 2018.

ISED-Registration No.: 8058A-1
Shenzhen Anbotek Compliance Laboratory Limited, EMC Laboratory has been registered and fully
described in a report filed with the (ISED) Innovation, Science and Economic Development Canada. The
acceptance letter from the ISED is maintained in our files. Registration 8058A-1, March 07, 2019.



Test Location
Shenzhen Anbotek Compliance Laboratory Limited.
1/F, Building D, Sogood Science and Technology Park, Sanwei community, Hangcheng Street, Bao'an
District, Shenzhen, Guangdong, China.518102




                                                                                            Code:AB-RF-05-a


Report No.: SZAWW190704002-01           FCC ID: 2AGLG-TP007       Page 9 of 27

2. Summary of Test Results
         Standard Section                Test Item               Result

   FCC Part 15, Paragraph 15.207   Conducted Emission Test       PASS
      FCC Part 15, Paragraph
                                      Spurious Emission          PASS
           15.209(a)(f)
             Part 15.203             Antenna Requirement         PASS




                                                              Code:AB-RF-05-a


Report No.: SZAWW190704002-01                               FCC ID: 2AGLG-TP007               Page 10 of 27

3. Conducted Emission Test
3.1. Test Standard and Limit
 Test Standard           FCC Part15 Section 15.207
                                                                  Maximum RF Line Voltage (dBuV)
                                Frequency
                                                          Quasi-peak Level             Average Level
 Test Limit                  150kHz~500kHz                    66 ~ 56 *                  56 ~ 46 *
                              500kHz~5MHz                         56                        46
                              5MHz~30MHz                          60                        50

 Remark: (1) *Decreasing linearly with logarithm of the frequency.
              (2) The lower limit shall apply at the transition frequency.

3.2. Test Setup




3.3. Test Procedure
The EUT system is connected to the power mains through a line impedance stabilization network
(L.I.S.N.). This provides a 50ohm coupling impedance for the EUT system. Please refer the block
diagram of the test setup and photographs. Both sides of AC line are checked to find out the maximum
conducted emission. In order to find the maximum emission levels, the relative positions of equipment
and all of the interface cables shall be changed according to FCC ANSI C63.10-2013 on Conducted
Emission Measurement.
The bandwidth of test receiver (ESCI) set at 9kHz.
The frequency range from 150kHz to 30MHz is checked.

3.4. Test Data
Please to see the following pages
                                                                                         Code:AB-RF-05-a


Report No.: SZAWW190704002-01                 FCC ID: 2AGLG-TP007       Page 11 of 27
Conducted Emission Test Data
Test Site:               1# Shielded Room
Operating Condition:     Mode 1
Test Specification:      AC 120V, 60Hz for adapter
Comment:                 Live Line
                         Tem.: 23.3℃ Hum.: 52%




                                                                    Code:AB-RF-05-a


Report No.: SZAWW190704002-01                 FCC ID: 2AGLG-TP007       Page 12 of 27
Conducted Emission Test Data
Test Site:               1# Shielded Room
Operating Condition:     Mode 1
Test Specification:      AC 120V, 60Hz for adapter
Comment:                 Neutral Line
                         Tem.: 23.3℃ Hum.: 52%




                                                                    Code:AB-RF-05-a


Report No.: SZAWW190704002-01                             FCC ID: 2AGLG-TP007                Page 13 of 27

4. Radiation Spurious Emission and Band Edge
4.1. Test Standard and Limit
Test Standard FCC Part15 C Section 15.209 and 15.205
                        Frequency              Field strength       Limit                     Measurement
                                                                                 Remark
                          (MHz)              (microvolt/meter)    (dBuV/m)                    distance (m)
                  0.009MHz~0.490MHz             2400/F(kHz)           -              -            300

                  0.490MHz-1.705MHz            24000/F(kHz)           -              -             30

                    1.705MHz-30MHz                   30               -             -              30

Test Limit           30MHz~88MHz                    100             40.0        Quasi-peak         3

                     88MHz~216MHz                   150             43.5        Quasi-peak         3

                    216MHz~960MHz                   200             46.0        Quasi-peak         3

                   960MHz~1000MHz                   500             54.0        Quasi-peak         3

                                                    500             54.0         Average           3
                     Above 1000MHz
                                                      -             74.0          Peak             3
Remark:
(1)The lower limit shall apply at the transition frequency.
(2) 15.35(b), Unless otherwise specified, the limit on peak radio frequency emissions is 20dB above the
maximum permitted average emission limit applicable to the equipment under test. This peak limit applies to
the total peak emission level radiated by the device.


4.2. Test Setup




                                            Figure 1. Below 30MHz


                                                                                         Code:AB-RF-05-a


Report No.: SZAWW190704002-01                      FCC ID: 2AGLG-TP007                 Page 14 of 27




                                      Figure 2. 30MHz to 1GHz




                                       Figure 3. Above 1 GHz


4.3. Test Procedure
For below 1GHz: The EUT is placed on a turntable, which is 0.8m above the ground plane.
For above 1GHz: The EUT is placed on a turntable, which is 1.5m above the ground plane.
The turn table can rotate 360 degrees to determine the position of the maximum emission level. The
EUT is set 3 meters away from the receiving antenna which is mounted on a antenna tower. The
antenna can be moved up and down from 1 to 4 meters to find out the maximum emission level. Rotated
the EUT through three orthogonal axes to determine the maximum emissions, both horizontal and
vertical polarization of the antenna are set on test. The EUT is tested in 9*6*6 Chamber. The device is
evaluated in xyz orientation.

                                                                                  Code:AB-RF-05-a


Report No.: SZAWW190704002-01                     FCC ID: 2AGLG-TP007         Page 15 of 27
For 9kHz to 150kHz, Set the spectrum analyzer as:
RBW = 200Hz, VBW =1kHz, Detector= Quasi-Peak, Trace mode= Max hold, Sweep- auto couple.

For 150kHz to 30MHz, Set the spectrum analyzer as:
RBW = 9KHz, VBW =30kHz, Detector= Quasi-Peak, Trace mode= Max hold, Sweep- auto couple.

For 30MHz to 1000MHz, Set the spectrum analyzer as:
RBW = 100kHz, VBW =300kHz, Detector= Quasi-Peak, Trace mode= Max hold, Sweep- auto couple.


4.4. Test Data
PASS

Note: The data is in TX mode, and this is the worst mode.




                                                                          Code:AB-RF-05-a


Report No.: SZAWW190704002-01                      FCC ID: 2AGLG-TP007                Page 16 of 27
Test Results
(Between 9KHz – 30MHz)
Job No.:            SZAWW190704002-01
Standard:           FCC PART15 C _3m           Power Source:           AC 120V, 60Hz for adapter
Test item:          Radiation Test            Temp.(C)/Hum.(%RH):      24.7℃/51%RH
Test Mode:          Mode 1                    Distance:                3m




Remark:According to FCC PART 15.209 (d), the emission limits for the frequency bands 9–90 kHz, 110–490
kHz and above 1000 MHz, Radiated emission limits in these three bands are based on measurements
employing an average detector.




                                                                                 Code:AB-RF-05-a


Report No.: SZAWW190704002-01        FCC ID: 2AGLG-TP007            Page 17 of 27
(Between 30MHz –1000 MHz)


Job No.:        SZAWW190704002-01   Polarization:          Horizontal
Standard:       FCC PART15 C _3m    Power Source:          AC 120V, 60Hz for adapter
Test item:      Radiation Test      Temp.(C)/Hum.(%RH):    22.2℃/57%RH
Test Mode:      Mode 1              Distance:              3m




                                                                Code:AB-RF-05-a


Report No.: SZAWW190704002-01       FCC ID: 2AGLG-TP007              Page 18 of 27



Job No.:        SZAWW190704002-01   Polarization:         Vertical
Standard:       FCC PART15 C _3m    Power Source:         AC 120V, 60Hz for adapter
Test item:      Radiation Test      Temp.(C)/Hum.(%RH):   22.2℃/57%RH
Test Mode:      Mode 1              Distance:             3m




                                                               Code:AB-RF-05-a


Report No.: SZAWW190704002-01                       FCC ID: 2AGLG-TP007                   Page 19 of 27

5. Antenna Requirement
5.1. Test Standard and Requirement
Test Standard     FCC Part15 Section 15.203
                  An intentional radiator shall be designed to ensure that no antenna other than that
                  furnished by the responsible party shall be used with the device. The use of a
Requirement
                  permanently attached antenna or of an antenna that uses a unique coupling to the
                  intentional radiator, the manufacturer may design the unit so that a broken antenna can



5.2. Antenna Connected Construction
The antenna is a Inductive loop coil Antenna which permanently attached, and the best case gain of the
antenna is 0 dBi. It complies with the standard requirement.



                                                                             Antenna




                                                                                     Code:AB-RF-05-a


Report No.: SZAWW190704002-01                   FCC ID: 2AGLG-TP007       Page 20 of 27

APPENDIX I -- TEST SETUP PHOTOGRAPH
                        Photo of Conducted Emission Measurement




                                Photo of Radiation Emission Test




                                                                      Code:AB-RF-05-a


Anbotek B2 ET F¢]]
eb e ELG4)           Anbotek Testing




Shenzhen Anbotek Compliance Laboratory Limited
Address: 1/F, Building—D, Sogood Science and Technology Park, SanweiCommunity,   @ Hotline
Hangcheng Street, Bac‘an District, Shenzhen, Guangdong, China.                   °/ 400—003—0500
Tel:(86)755—26066440.—~—   Fax:(86)755—26014772   Email:service@anbotek.com      www.anbotek.com


Report No.: SZAWW190704002-01   FCC ID: 2AGLG-TP007       Page 22 of 27

APPENDIX II -- EXTERNAL PHOTOGRAPH




                                                      Code:AB-RF-05-a


Cudach l 521¥lt i
 seAnbotek Testing




Shenzhen Anbotek Compliance Laboratory Limited
Address: 1/F, Building:—D, Sogood Science and Technology Park, SanweiCommunity,   @ Hotline
Hangcheng Street, Bac‘an District, Shenzhen, Guangdong, China.                     °/ 400—003—0500
Tel:(86)755—26066440        Fax:(86)755—26014772    Email:service @anbotek.com    www.anbotek.com


Cudach
 AooratseiiP
            l 521¥lti
              Anbotek Testing




                                                      9   10   11121314 15161718 1920 21222324252921   2028




 Shenzhen Anbotek Compliance Laboratory Limited
 Address: 1/F, Building:—D, Sogood Science and Technology Park, SanweiCommunity,                 @ Hotline
 Hangcheng Street, Bac‘an District, Shenzhen, Guangdong, China.                                   °/ 400—003—0500
 Tel:(86)755—26066440        Fax:(86)755—26014772    Email:service @anbotek.com                  www.anbotek.com


Anbotek B2 ETF¢]]
AooratseiiP          Anbotek Testing




                    in
                                                           i    I    1
                    * P 0      7 2 3 a 5   6   7   8    9 10 111213141516 171819 20 2122232428282 28783




Shenzhen Anbotek Compliance Laboratory Limited
Address: 1/F, Building—D, Sogood Science and Technology Park, SanweiCommunity,                 @ Hotline
Hangcheng Street, Bac‘an District, Shenzhen, Guangdong, China.                                 °/ 400—003—0500
Tel:(86)755—26066440.—~—   Fax:(86)755—26014772        Email:service@anbotek.com               www.anbotek.com


Report No.: SZAWW190704002-01   FCC ID: 2AGLG-TP007       Page 26 of 27

APPENDIX III -- INTERNAL PHOTOGRAPH




                                                      Code:AB-RF-05-a


Anbotek B2 ET F¢]]
AooratseiiP          Anbotek Testing




                                        Anbotek
                                          Product Safety




Shenzhen Anbotek Compliance Laboratory Limited
Address: 1/F, Building—D, Sogood Science and Technology Park, SanweiCommunity,   @ Hotline
Hangcheng Street, Bac‘an District, Shenzhen, Guangdong, China.                   °/ 400—003—0500
Tel:(86)755—26066440.—~—   Fax:(86)755—26014772   Email:service@anbotek.com      www.anbotek.com



Document Created: 2019-07-24 06:09:55
Document Modified: 2019-07-24 06:09:55

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC