18_TM156 RFExp

FCC ID: 2AGLG-TM156

RF Exposure Info

Download: PDF
FCCID_4257565

                                Dongguan Nore Testing Center Co., Ltd.
                                     Report No.: NTC1903162F-1
                                       FCC ID: 2AGLG-TM156




                          RF EXPOSURE EVALUATION
                              EUT Specification
EUT                          Dual Mode Vertical Mouse
Frequency band                 WLAN: 2.412GHz ~ 2.462GHz
(Operating)                    WLAN: 5.18GHz ~ 5.32GHz / 5.50GHz ~ 5.70GHz
                               WLAN: 5.745GHz ~ 5825GHz
                               Others(2403~2480MHz)
Device category                Portable (<20cm separation)
                               Mobile (>20cm separation)
                               Others ___
Antenna diversity              Single antenna
                               Multiple antennas
                               Tx diversity
                               Rx diversity
                               Tx/Rx diversity
Max. output power            98.98 dBuV/m (3.72dBm)( 2.36mW)
Antenna gain                 0dBi
Evaluation applied             SAR Exclusion Evaluation


                               Standard Requirement

Portable Device

According to §15.247(i) and §1.1307b(1), systems operating under the provisions of this section
shall be operated in a manner that ensures that the public is not exposed to radio frequency
energy levels in excess of the Commission’s guidelines. See KDB 447498 D01 General RF
Exposure Guidance v05, section 4.3.1.

The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation
distances ≤ 50 mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,16 where
·f(GHz) is the RF channel transmit frequency in GHz
·Power and distance are rounded to the nearest mW and mm before calculation17
·The result is rounded to one decimal place for comparison
The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm
and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test
separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion.


                              Dongguan Nore Testing Center Co., Ltd.
                                   Report No.: NTC1903162F-1
                                     FCC ID: 2AGLG-TM156




                               Measurement Result

   Channel      Max Output    Max Output         Max Output            Calculati   Threshold
  Frequency        power      power (dBm)        power (mW)            on Value      Value
                                                                        (Note 1)
    (MHz)        (dBuV/m)
     2403          97.65           2.39               1.73              0.536         3.0
     2441          92.67          -2.59               0.55              0.172         3.0
     2480          98.98           3.72               2.36              0.743         3.0




            EIRP= E-104.8+20logD=98.98-104.8+20log3=3.72dBm

Note 1: Calculation Value =[(max. power of channel, mW)/(min.
        test separation distance, mm)] ·[√f(GHz)].
        Fox example:2.36/5*√2.48=0.743 ≤ 3.0

According to KDB447498 D01 V06, threshold at which no SAR required is ≤3.0 for 1-g
SAR, separation distance is 5mm, and no simultaneous SAR measurement is required.



Document Created: 2019-04-26 16:12:36
Document Modified: 2019-04-26 16:12:36

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC