RF Exposure

FCC ID: 2AGGYCWAP

RF Exposure Info

Download: PDF
FCCID_4008846

                                                                                                               EMC Test Data
     Client: Thales Avionics, Inc.                                                                       Job Number:     JD101779
                                                                                                       T-Log Number:     T103414
     Model: CWAP
                                                                                                     Project Manager:    Irene Rademacher
  Contact: Marcus Madray                                                                          Project Coordinator:   -
 Standard: FCC 15.207, 15.209, 15.247, 15.407, RSS-247                                                         Class:    N/A


                                  Maximum Permissible Exposure / SAR Exclusion

Test Specific Details
                           The objective of this test session is to perform final qualification testing of the EUT with respect to the
              Objective:
                           specification listed above.
     Date of Evaluation: 3/9/2018
         Test Engineer: David Bare

General Test Configuration
Calculation uses the free space transmission formula:
                            S = (PG)/(4 πd2)
Where: S is power density (W/m2), P is output power (W), G is antenna gain relative to isotropic, d is separation distance from the
transmitting antenna (m).

Summary of Results

                Device complies with Power Density requirements at 20cm
                                                                                     No
                                                            separation:
                                 If not, required separation distance (in cm):       22


Modifications Made During Testing
No modifications were made to the EUT during testing

Deviations From The Standard
No deviations were made from the requirements of the standard.




T103414 Thales.xls                                                MPE Calc                                                          Page 1 of 3


                                                                                                           EMC Test Data
     Client: Thales Avionics, Inc.                                                                  Job Number:     JD101779
                                                                                                  T-Log Number:     T103414
     Model: CWAP
                                                                                                Project Manager:    Irene Rademacher
  Contact: Marcus Madray                                                                     Project Coordinator:   -
 Standard: FCC 15.207, 15.209, 15.247, 15.407, RSS-247                                                    Class:    N/A

FCC MPE Calculation
Use:     General
Antenna: 2.4 GHz - Integral 8.9 dBi (effective gain); 5 GHz - Integral 10.7 dBi (effective gain)

                        EUT            Cable Loss     Ant         Power                     Power Density (S)             MPE Limit
   Freq.               Power             Loss         Gain        at Ant       EIRP            at 22 cm
   MHz          dBm            mW*        dB          dBi          dBm         mW              mW/cm^2                    mW/cm^2
   2412         17.9           61.7        0          8.9          17.9       478.8              0.079                     1.000
   2437         22.9           193.9       0          8.9          22.9       1505.9             0.248                     1.000
   2462         15.5           35.5        0          8.9          15.5       275.5              0.045                     1.000

For the cases where S > the MPE Limit

   Freq.           S @ 22 cm                 MPE Limit              Distance where
   MHz             mW/cm^2                   mW/cm^2                S <= MPE Limit           % of MPE Limit
   2412              0.079                    1.000                      6.2cm                    7.9%
   2437              0.248                    1.000                     10.9cm                   24.8%
   2462              0.045                    1.000                      4.7cm                    4.5%

                        EUT            Cable Loss     Ant         Power                     Power Density (S)             MPE Limit
   Freq.               Power             Loss         Gain        at Ant       EIRP            at 22 cm
   MHz          dBm            mW*        dB          dBi          dBm         mW              mW/cm^2                    mW/cm^2
   5755         23.8           240.5       0          10.7         23.8       2819.8             0.464                     1.000
   5795         23.7           236.7       0          10.7         23.7       2775.4             0.456                     1.000
   5825         23.3           212.4       0          10.7         23.3       2490.7             0.410                     1.000

For the cases where S > the MPE Limit

               Power Density (S)             MPE Limit              Distance where
   Freq.          at 22 cm                   at 20 cm               S <= MPE Limit
   MHz            mW/cm^2                    mW/cm^2                      cm                 % of MPE Limit
   5755             0.464                     1.000                     15.0cm                   46.4%
   5795             0.456                     1.000                     14.9cm                   45.6%
   5825             0.410                     1.000                     14.1cm                   41.0%

Worst case RF exposure is the sum of the ratios for the two radios, 24.8% + 46.4% = 71.2 % of the limit.




T103414 Thales.xls                                             MPE Calc                                                      Page 2 of 3


                                                                                                          EMC Test Data
     Client: Thales Avionics, Inc.                                                                  Job Number:     JD101779
                                                                                                  T-Log Number:     T103414
     Model: CWAP
                                                                                                Project Manager:    Irene Rademacher
  Contact: Marcus Madray                                                                     Project Coordinator:   -
 Standard: FCC 15.207, 15.209, 15.247, 15.407, RSS-247                                                    Class:    N/A

Industry Canada MPE Calculation
Use:       General
Antenna: 2.4 GHz - Integral 8.9 dBi (effective gain); 5 GHz - Integral 10.7 dBi (effective gain)

USE THIS FOR 300-6000 MHz single transmitters (General use)
                   EUT          Cable Loss      Ant      Power                              Power Density (S)             MPE Limit
  Freq.           Power             Loss       Gain       at Ant                EIRP           at 22 cm
  MHz        dBm        mW*          dB         dBi        dBm                  mW             mW/cm^2                    mW/cm^2
  2412       17.9        61.7         0         8.9        17.9                478.76            0.079                     0.537
  2437       22.9       193.9         0         8.9        22.9               1505.88            0.248                     0.540
  2462       15.5        35.5         0         8.9        15.5                275.50            0.045                     0.544

For the cases where S > the MPE Limit

               Power Density (S)             MPE Limit              Distance where
   Freq.          at 22 cm                   at 20 cm               S <= MPE Limit
   MHz            mW/cm^2                    mW/cm^2                      cm                 % of MPE Limit
   2412             0.079                     0.537                       8.4                    14.7%
   2437             0.248                     0.540                      14.9                    45.8%
   2462             0.045                     0.544                       6.3                     8.3%


                        EUT            Cable Loss     Ant         Power                     Power Density (S)             MPE Limit
   Freq.               Power             Loss         Gain        at Ant       EIRP            at 22 cm
   MHz          dBm            mW*        dB          dBi          dBm          mW             mW/cm^2                    mW/cm^2
   5755         23.8           240.5       0          10.7         23.8       2819.82            0.464                     0.972
   5795         23.7           236.7       0          10.7         23.7       2775.37            0.456                     0.977
   5825         23.3           212.4       0          10.7         23.3       2490.70            0.410                     0.980

For the cases where S > the MPE Limit

               Power Density (S)             MPE Limit              Distance where
   Freq.          at 22 cm                   at 20 cm               S <= MPE Limit
   MHz            mW/cm^2                    mW/cm^2                      cm                 % of MPE Limit
   5755             0.464                     0.972                      15.2                    47.7%
   5795             0.456                     0.977                      15.0                    46.7%
   5825             0.410                     0.980                      14.2                    41.8%


Worst case RF exposure is the sum of the ratios for the two radios, 45.8% + 47.7% = 93.5% of the limit.

Worst case MPE value is 0.248 + 0.464 = 0.712 mW/cm2 (7.12 W/m2)




T103414 Thales.xls                                             MPE Calc                                                      Page 3 of 3



Document Created: 2018-09-13 14:46:50
Document Modified: 2018-09-13 14:46:50

© 2024 FCC.report