2AGBW9290012630X_MPE_Rev2

FCC ID: 2AGBW9290012630X

Test Report

Download: PDF
FCCID_3026387

Philips Lighting (China) Investment Co., Ltd.           FCC ID: 2AGBW9290012630X                                        Page 1 of 7




                                        Application for FCC Certification
                                                   On behalf of

                                  Philips Lighting (China) Investment Co., Ltd.

                                           Product Name: LED MODULE;

                                                Model No.: Hue Engine V1.0


                                         FCC ID: 2AGBW9290012630X

                                                   (MPE Calculation)




                               Prepared For : Philips Lighting (China) Investment Co., Ltd.
                                              Building 9#, Lane 888, Tianlin Road, Minhang District,
                                              Shanghai 200233, China



                               Prepared By : Audix Technology (Shanghai) Co., Ltd.
                                             3F and 4F, 34Bldg 680 Guiping Rd.,
                                             Caohejing Hi-Tech Park,
                                             Shanghai 200233, China


                                                 Tel: +86-21-64955500
                                                 Fax: +86-21-64955491




                                                 Report No.     :      ACI-F16054
                                                 Date of Test   :      Mar. 10, 2016
                                                 Date of Report :      Mar. 16, 2016



                                                                    Audix Technology (Shanghai) Co., Ltd.   Report No.: ACI-F16054


Philips Lighting (China) Investment Co., Ltd.                     FCC ID: 2AGBW9290012630X                                                Page 2 of 7




                                                   TABLE OF CONTENTS

                                                                                                                                      Page

     1 GENERAL INFORMATION.......................................................................................................... 4
       1.1 Description of Equipment Under Test........................................................................................ 4
       1.2 Description of Test Facility ........................................................................................................ 5
       1.3 Measurement Uncertainty .......................................................................................................... 5
     2 SUMMARY OF STANDARDS AND RESULTS .......................................................................... 6
       2.1 Applicable Standard ................................................................................................................... 6
       2.2 Specification Limits ................................................................................................................... 6
       2.3 MPE Calculation Method ........................................................................................................... 6
       2.4 Calculated Result ........................................................................................................................ 7




                                                                                Audix Technology (Shanghai) Co., Ltd.      Report No.: ACI-F16054


Philips Lighting (China) Investment Co., Ltd.         FCC ID: 2AGBW9290012630X                                      Page 3 of 7


                                 TEST REPORT FOR FCC CERTIFICATE

              Applicant             :    Philips Lighting (China) Investment Co., Ltd.
              EUT Description :          LED MODULE;
                                         (A) Model No.    :        Hue Engine V1.0
                                         (B) Power Supply :        DC 3.3V

              Test Procedure Used:

                                      FCC Part 1 Subpart I and Part 2 Subpart J
                                  KDB 447498 D01 General RF Exposure Guidance v06


              The device described above is tested by Audix Technology (Shanghai) Co., Ltd. to
              determine the maximum emission levels emanating from the device. The maximum
              emission levels are compared to the FCC Part2.
              The test results are contained in this test report and Audix Technology (Shanghai) Co.,
              Ltd. is assumed full responsibility for the accuracy and completeness of these
              measurements. This report also shows that the EUT (M/N: Refer to Sec2.1), which was
              tested on Mar. 10, 2016 is technically compliance with the FCC limits.
              This report applies to above tested sample only. This report shall not be reproduced in
              part without written approval of Audix Technology (Shanghai) Co., Ltd.

              This report must not be used by the client to claim product certification, approval, or
              endorsement by NVLAP, NIST, or any agency of the federal government.


             Date of Test :                     Mar. 10, 2016                  Date of Report :           Mar. 16, 2016

             Producer :
                                           ALAN HE / Assistant

             Review :
                                        SAMMY CHEN/ Manager




             Signatory :
                                 BYRON KWO/Assistant General Manager




                                                                Audix Technology (Shanghai) Co., Ltd.   Report No.: ACI-F16054


Philips Lighting (China) Investment Co., Ltd.         FCC ID: 2AGBW9290012630X                                      Page 4 of 7



          1 GENERAL INFORMATION


                 1.1 Description of Equipment Under Test

                         Description            :   LED MODULE;

                         Type of EUT                 Production     Pre-product  Pro-type

                         Model Number :             Hue Engine V1.0

                         Radio Tech             :   Zigbee

                         Channel Freq.          :   2405MHz, 2425MHz, 2450MHz, 2475MHz, 2480MHz

                         Tested Freq.           :   2412MHz, 2450MHz, 2480MHz

                         Modulation             :   O-QPSK

                         Antenna Gain           :   0 dBi

                         Applicant              :   Philips Lighting (China) Investment Co., Ltd.
                                                    Building 9#, Lane 888, Tianlin Road, Minhang District,
                                                    Shanghai 200233, China




                                                                Audix Technology (Shanghai) Co., Ltd.   Report No.: ACI-F16054


Philips Lighting (China) Investment Co., Ltd.     FCC ID: 2AGBW9290012630X                                      Page 5 of 7



                 1.2      Description of Test Facility
                        Site Description                 : Sept. 17, 1998 file on
                        (Semi-Anechoic Chamber)           Jan. 15, 2015 Renewed
                                                          Federal Communications Commission
                                                          FCC Engineering Laboratory
                                                          7435 Oakland Mills Road
                                                          Columbia, MD 21046, USA

                        Name of Firm                     : Audix Technology (Shanghai) Co., Ltd.

                        Site Location                    : 3F 34 Bldg 680 Guiping Rd.,
                                                           Caohejing Hi-Tech Park,
                                                           Shanghai 200233, China

                        FCC registration Number          : 91789

                        Accredited by NVLAP, Lab Code : 200371-0

                 1.3 Measurement Uncertainty
                        Output Power Expanded Uncertainty      : U = ±1.56 dB




                                                            Audix Technology (Shanghai) Co., Ltd.   Report No.: ACI-F16054


Philips Lighting (China) Investment Co., Ltd.         FCC ID: 2AGBW9290012630X                                    Page 6 of 7




          2 SUMMARY OF STANDARDS AND RESULTS

                 2.1 Applicable Standard
                       FCC Part1 §1.1310

                 2.2 Specification Limits
                       Limits for General Population/Uncontrolled Exposure
                       Frequency       Electric Field Magnetic Field Power            Averaging Time
                       Range           Strength (E)   Strength (H)     Density (S)    |E|2, |H|2 or S
                       (MHz)           (V/m)          (A/m)            (mW/cm2)       (minutes)
                       0.3-1.34        614            1.63             (100)*         30
                       1.34-30         824/f          2.19/f           (180/f2)*      30
                       30-300          27.5           0.073            0.2            30
                       300-1500        --             --               f/1500         30
                       1500-100,000 --                --               1.0            30
                       f = frequency in MHz              *Plane-wave equivalent power density

                       NOTE: General population/uncontrolled exposures apply in situations in which
                       the general public may be exposed, or in which persons that are exposed as a
                       consequence of their employment may not be fully aware of the potential for
                       exposure or can not exercise control over their exposure.

                       The limit value 1.0mW/cm2 is available for this EUT.

                 2.3 MPE Calculation Method

                       S = PG/(4πR2)
                                                0.5
                       R = [PG/(4πS)]

                       where: S = power density (in appropriate units, e.g. mW/ cm2)
                              P = power input to the antenna (in appropriate units, e.g., mW)
                              (the measured power value see Report: F16053 Section 5.6)
                              G = power gain of the antenna in the direction of interest relative to an
                              isotropic radiator
                              R = distance to the center of radiation of the antenna (appropriate units,
                              e.g., cm)




                                                              Audix Technology (Shanghai) Co., Ltd.   Report No.: ACI-F16054


Philips Lighting (China) Investment Co., Ltd.          FCC ID: 2AGBW9290012630X                                      Page 7 of 7




                 2.4 Calculated Result

                          2.4.1 Radio Frequency Radiation Exposure Evaluation
                             Peak       Output Power                                Power
          Frequency                                          Antenna Gain                                    Limit
                            Power        to Antenna                                Density
            (MHz)           (dBm)           (mW)           (dBi)       (Numeric) (mW/cm2)                 (mW/cm2)
             2405            1.192           1.32            0            1       0.000262                  1.0
             2450           -1.468              0.71         0               1           0.000142             1.0
             2480         -12.320        0.06                0               1           0.000018             1.0
                       Separation distance R= 20cm.


                             Peak       Output Power
          Frequency                                          Antenna Gain                  Limit           Distance
                            Power        to Antenna
            (MHz)           (dBm)           (mW)           (dBi)       (Numeric) (mW/cm2)                    (cm)
             2405            1.192           1.32            0            1        1.0                       0.32
             2450           -1.468              0.71         0               1               1.0             0.24
             2480         -12.320           0.06          0           1            1.0          0.07
                       The antenna used for this transmitter must be installed to provide a separation
                       distance of at least 0.32 cm from all persons.




                                                                 Audix Technology (Shanghai) Co., Ltd.   Report No.: ACI-F16054



Document Created: 2016-06-14 15:01:08
Document Modified: 2016-06-14 15:01:08

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC