Test Report

FCC ID: 2AGA7MW07L

Test Report

Download: PDF
FCCID_3944186

                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch.

No. 1 Workshop, M-10, Middle section, Science & Technology Park,
Shenzhen, Guangdong, China 518057
Telephone:            +86 (0) 755 2601 2053                                                                                        Report No.: SZEM180500464503
Fax:                  +86 (0) 755 2671 0594
                                                                                                                                   Page      : 1 of 19
Email:                ee.shenzhen@sgs.com


1 COVER PAGE

                                                                  FCC REPORT
        Application No. :                                          SZEM1805004645CR
        Applicant:                                                 NEW AUDIO LLC.
        Address of Applicant:                                      132 W. 31st 7th Floor New York, United States 10001
        Manufacturer/ Factory:                                     NEW AUDIO LLC.
        Address of Manufacturer/                                   132 W. 31st 7th Floor New York, United States 10001
        Factory:
        Product Name:                                              MW07 Truewireless Earphone
        Model No.(EUT):                                            MW07
        Trade Mark:                                                Master&Dynamic
        FCC ID:                                                    2AGA7MW07L
        Standards:                                                 47 CFR Part 15, Subpart C
        Date of Receipt:                                           2018-06-04
        Date of Test:                                              2018-06-12 to 2018-06-20
        Date of Issue:                                             2018-06-25
       Test Result:                                               PASS *
      * In the configuration tested, the EUT complied with the standards specified above.




                     Keny Xu
               EMC Laboratory Manager
The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report.
If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new
system complies with all relevant standards. Any mention of SGS International Electrical Approvals or testing done by SGS
International Electrical Approvals in connection with, distribution or use of the product described in this report must be approved by SGS
International Electrical Approvals in writing.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights
and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification
of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the
sample(s) tested and such sample(s) are retained for 30 days only.


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                                 Report No.: SZEM180500464503
                                                                                                                                 Page      : 2 of 19




2 Version
                                                                                           Revision Record
                Version                     Chapter                                         Date                                        Modifier                              Remark

                 01                                                                  2018-06-25                                                                               Original




       Authorized for issue by:




                                                                    Bill Chen /Project Engineer




                                                                    Eric Fu /Reviewer




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights
and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification
of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the
sample(s) tested and such sample(s) are retained for 30 days only.


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                                  Report No.: SZEM180500464503
                                                                                                                                  Page      : 3 of 19

2          Test Summary
                       Test Item                                        Test Requirement                                               Test method                                        Result
      Radiated Spurious                                          47 CFR Part 15, Subpart C
                                                                                                                                 ANSI C63.10 (2013)                                       PASS
      emissions                                                    Section 15.205/15.209

      20dB Occupied                                               47 CFR Part 15, Subpart C
                                                                                                                                  ANSI C63.10 (2013)                                      PASS
      Bandwidth                                                           Section




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation
of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its
intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery
or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report
refer only to the sample(s) tested and such sample(s) are retained for 30 days only.


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                                  Report No.: SZEM180500464503
                                                                                                                                  Page      : 4 of 19

3          Contents
                                                                                                                                                                                                    Page
1         COVER PAGE .......................................................................................................................................... 1

2         VERSION .................................................................................................................................................. 2

2         TEST SUMMARY ..................................................................................................................................... 3

3         CONTENTS .............................................................................................................................................. 4

4         GENERAL INFORMATION ...................................................................................................................... 5
     4.1       GENERAL DESCRIPTION OF EUT ............................................................................................................. 5
     4.2       TEST ENVIRONMENT AND MODE .............................................................................................................. 6
     4.3       DESCRIPTION OF SUPPORT UNITS ........................................................................................................... 6
     4.4       TEST LOCATION ...................................................................................................................................... 6
     4.5       TEST FACILITY ........................................................................................................................................ 7
     4.6       DEVIATION FROM STANDARDS ................................................................................................................. 7
     4.7       ABNORMALITIES FROM STANDARD CONDITIONS ........................................................................................ 7
     4.8       OTHER INFORMATION REQUESTED BY THE CUSTOMER ............................................................................. 7
     4.9       EQUIPMENT LIST ..................................................................................................................................... 8
5         TEST RESULTS AND MEASUREMENT DATA ...................................................................................... 9
     5.1       RADIATED EMISSION ............................................................................................................................... 9
     5.2       20DB OCCUPY BANDWIDTH ................................................................................................................... 16
6         PHOTOGRAPHS - EUT TEST SETUP .................................................................................................. 18
     6.1       RADIATD EMISSION (30MHZ-1000MHZ) ................................................................................................ 18
     6.2       RADIATED SPURIOUS EMISSION (BELOW 30MHZ) .................................................................................. 19




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation
of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its
intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery
or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report
refer only to the sample(s) tested and such sample(s) are retained for 30 days only.


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                                  Report No.: SZEM180500464503
                                                                                                                                  Page      : 5 of 19

4           General Information
4.1 General Description of EUT
           Power supply:                                             Left ear: Li-ion rechargeable battery DC 3.7V
           Cable:                                                    Type C cable:96cm unshielded
         Operation Frequency:                                        10.54MHz
         Antenna Type:                                               Loop Antenna




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation
of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its
intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery
or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report
refer only to the sample(s) tested and such sample(s) are retained for 30 days only.


                            SGS—CSTC Standards Technical Services Co., Ltd.
                            Shenzhen Branch
                                                              Report No.: SZEM1s0s004s4503
                                                              Page        sot 19


4.2 Test Environment and Mode
    Operating Environment
    Temperature                mo‘o
     Homay                     s57.m
    Amospharic Fressure:       1010 mbar
    Test mode:
    T mode                     Keep te EUT inransmiting mode
4.3 Description of Support Units
    "The EUT has been tested wih ascocited equipment below
           Deseripton              Manutacturer                 Model No:
             Adapter                   Accle                 »i57 worntost

4.4 Test Location
    Alltests were perfomed at
    868—08TG Standards Technial Services Co., Lid. Shonzhen Branch
    No. 1 Workshap, M—10, MSecton, Science & Technology Park,Shenzhen, Guangdong, Chine.
    steosr.
    Tok +8755 2e01 2089 Fax «85 7os 2eriosna




rnnonptsmntersorenc
Ipuoredommone         un e orctnc ninrnconomvimon
                    nimointome       mtpoounool   oconormntercmmnrc
                                                     leceecemen     ecncetname
                                                                       temiel


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                                  Report No.: SZEM180500464503
                                                                                                                                  Page      : 7 of 19



4.5 Test Facility
            The test facility is recognized, certified, or accredited by the following organizations:
            • CNAS (No. CNAS L2929)
            CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
            Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
            Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
            Laboratories) for the competence in the field of testing.
            • A2LA (Certificate No. 3816.01)
            SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
            American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
            • VCCI
            The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz,
            Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
            Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have been
            registered in accordance with the Regulations for Voluntary Control Measures with Registration No.: G-
            20026, R-14188, C-12383 and T-11153 respectively.
            • FCC –Designation Number: CN1178
            SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
            as an accredited testing laboratory.
            Designation Number: CN1178. Test Firm Registration Number: 406779.
            • Industry Canada (IC)
            Two 3m Semi-anechoic chambers and the 10m Semi-anechoic chamber of SGS-CSTC Standards
            Technical Services Co., Ltd. Shenzhen Branch EMC Lab have been registered by Certification and
            Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 4620C-1,
            4620C-2, 4620C-3.

4.6 Deviation from Standards
           None.


4.7 Abnormalities from Standard Conditions
           None.

4.8 Other Information Requested by the Customer
           None.




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation
of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its
intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery
or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report
refer only to the sample(s) tested and such sample(s) are retained for 30 days only.


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                                  Report No.: SZEM180500464503
                                                                                                                                  Page      : 8 of 19

4.9 Equipment List

RE in Chamber
                                                                                                                                                          Cal. Date                  Cal. Due date
         Test Equipment                               Manufacturer                           Model No.                      Inventory No.
                                                                                                                                                        (yyyy-mm-dd)                 (yyyy-mm-dd)
  10m Semi-Anechoic
                          SAEMC          FSAC1018                                                                            SEM001-03                    2018-03-31                   2021-03-30
        Chamber
   EMI Test Receiver
                      Rohde & Schwarz      ESR                                                                               SEM004-03                    2018-04-02                   2019-04-01
       (9k-7GHz)
   Trilog-Broadband
        Antenna         Schwarzbeck      VULB9168                                                                            SEM003-18                    2016-06-29                   2019-06-28
      (30M-1GHz)
     Pre-amplifier        Sonoma
                                           310N                                                                              SEM005-04                    2018-04-13                   2019-04-12
     (9kHz-1GHz)       Instrument Co
    Loop Antenna
                       ETS-Lindgren        6502                                                                              SEM003-08                    2017-08-22                   2020-08-21
    (9kHz-30MHz)
 Measurement Software      AUDIX      e3 V8.2014-6-27                                                                           N/A                          N/A                          N/A
    Coaxial Cable           SGS             N/A                                                                              SEM029-01                    2017-07-13                   2018-07-12

Conducted
             Equipment                                   Manufacturer                            Model No                   Inventory No                     Cal Date                Cal Due Date
     DC Power Supply                       RXN-305D     ZhaoXin                                                              SEM011-02                    2017-09-27                  2018-09-26
     Spectrum Analyzer                         FSP  Rohde & Schwarz                                                          SEM004-06                    2017-09-27                  2018-09-26
                                            JS1120-2
 Measurement Software    JS Tonscend                                                                                                N/A                          N/A                          N/A
                                           BT/WIFI V2.
    Coaxial Cable            SGS               N/A                                                                           SEM031-02                    2017-07-13                  2018-07-12
      Attenuator      Weinschel Associates    WA41                                                                           SEM021-09                       N/A                         N/A
   Signal Generator       KEYSIGHT           N5173B                                                                          SEM006-05                    2017-09-27                  2018-09-26
     Power Meter       Rohde & Schwarz        NRVS                                                                           SEM014-02                    2017-09-27                  2018-09-26



General used equipment
             Equipment                                   Manufacturer                            Model No                   Inventory No                     Cal Date                Cal Due Date
                                                         Shanghai
  Humidity/ Temperature
                                                       Meteorological                              ZJ1-2B                    SEM002-03                    2017-09-29                  2018-09-28
        Indicator
                                                      Industry Factory
                                                         Shanghai
  Humidity/ Temperature
                                                       Meteorological                              ZJ1-2B                    SEM002-04                    2017-09-29                  2018-09-28
        Indicator
                                                      Industry Factory
  Humidity/ Temperature
                                                               Mingle                                 N/A                    SEM002-08                    2017-09-29                  2018-09-28
        Indicator
                                                        Changchun
              Barometer                                Meteorological                               DYM3                     SEM002-01                    2018-04-08                  2019-04-07
                                                      Industry Factory


This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation
of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its
intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery
or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report
refer only to the sample(s) tested and such sample(s) are retained for 30 days only.


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                                  Report No.: SZEM180500464503
                                                                                                                                  Page      : 9 of 19

5           Test results and Measurement Data

5.1 Radiated Emission
           Test Requirement:                         47 CFR Part 15C Section 15.209 and 15.205
           Test Method:                              ANSI C63.10: 2013
           Test Site:                                Measurement Distance: 10m (Semi-Anechoic Chamber)
           Receiver Setup:                                   Frequency                          Detector                    RBW                   VBW                           Remark
                                                          30MHz-1GHz                         Quasi-peak                   100kHz                300kHz                 Quasi-peak Value
                                                           Above 1GHz                              Peak                     1MHz                 3MHz                        Peak Value
           Limit:                                                                                   Field strength   Limit                                                        Measurement
                                                                 Frequency                                                                                  Remark
                                                                                                 (microvolt/meter) (dBuV/m)                                                       distance (m)
                                                       0.009MHz-0.490MHz                              2400/F(kHz)                           -                      -                        300
                                                       0.490MHz-1.705MHz                             24000/F(kHz)                           -                      -                         30
                                                          1.705MHz-30MHz                                       30                           -                      -                         30
                                                             30MHz-88MHz                                      100                       40.0              Quasi-peak                          3
                                                            88MHz-216MHz                                      150                       43.5              Quasi-peak                           3
                                                           216MHz-960MHz                                      200                       46.0              Quasi-peak                           3
                                                             960MHz-1GHz                                      500                       54.0              Quasi-peak                           3
                                                               Above 1GHz                                     500                       54.0                Average                           3
           Test Procedure:                           a. For below 1GHz, the EUT was placed on the top of a rotating table 0.8
                                                        meters above the ground at a 3 and 10 meter semi-anechoic chamber. The
                                                        table was rotated 360 degrees to determine the position of the highest
                                                        radiation.
                                                     b. For above 1GHz, the EUT was placed on the top of a rotating table 1.5
                                                        meters above the ground at a 3 meter full-anechoic chamber. The table was
                                                        rotated 360 degrees to determine the position of the highest radiation.
                                                     c.      The EUT was set 3 or 10 meters away from the interference-receiving
                                                             antenna, which was mounted on the top of a variable-height antenna tower.
                                                     d. The antenna height is varied from one meter to four meters above the ground
                                                        to determine the maximum value of the field strength. Both horizontal and
                                                        vertical polarizations of the antenna are set to make the measurement.
                                                     e. For each suspected emission, the EUT was arranged to its worst case and
                                                        then the antenna was tuned to heights from 1 meter to 4 meters (for the test
                                                        frequency of below 30MHz, the antenna was tuned to heights 1 meter) and
                                                        the rotatable table was turned from 0 degrees to 360 degrees to find the
                                                        maximum reading.
                                                     f.      The test-receiver system was set to Peak Detect Function and Specified
                                                             Bandwidth with Maximum Hold Mode.
                                                     g. If the emission level of the EUT in peak mode was 10dB lower than the limit
                                                        specified, then testing could be stopped and the peak values of the EUT
                                                        would be reported. Otherwise the emissions that did not have 10dB margin
                                                        would be re-tested one by one using peak, quasi-peak or average method as
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation
of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its
intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery
or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report
refer only to the sample(s) tested and such sample(s) are retained for 30 days only.


                                                            SGS-CSTC Standards Technical Services Co., Ltd.
                                                            Shenzhen Branch
                                                                                                                                   Report No.: SZEM180500464503
                                                                                                                                   Page      : 10 of 19
                                                              specified and then reported in a data sheet.
                                                      h. The radiation measurements are performed in X, Y, Z axis positioning for
                                                         Transmitting mode, and found the X axis positioning which it is the worst
                                                         case.
                                                      i.      Repeat above procedures until all frequencies measured was complete.
            Test Setup:




                                                                                Figure 1. 30MHz to 1GHz
            Instruments Used:                         Refer to section 4.10 for details
            Test Mode:                                NFMI mode
            Test Results:                             Pass

 Field Strength Of The Fundamental Signal
                                              Antenna              Preamp                Read                Level                   Level                 Limit Line                Over
Frequency               Cable                                                                                                                                                                        Polari
                                               Factor               Factor               Level               @10m                   @ 30m                   @ 30m                    Limit
  (MHz)               Loss (dB)                                                                                                                                                                      zation
                                               (dB/m)                (dB)               (dBuV)             (dBuV/m)                (dBuV/m)                (dBuV/m)                  (dB)
  10.54                    0.50                 10.66                32.90               55.05                33.31                     4.69                    29.5               -24.81                H
  10.54                    0.50                 10.66                32.90               53.84                32.10                     3.48                    29.5               -26.02                V




 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
 electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation
 of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its
 intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
 their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery
 or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report
 refer only to the sample(s) tested and such sample(s) are retained for 30 days only.


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                                  Report No.: SZEM180500464503
                                                                                                                                  Page      : 11 of 19

Below 30MHz
QP value:0.009MHz-0.15MHz




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation
of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its
intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery
or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report
refer only to the sample(s) tested and such sample(s) are retained for 30 days only.


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                                  Report No.: SZEM180500464503
                                                                                                                                  Page      : 12 of 19

QP value:0.15MHz-30MHz




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation
of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its
intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery
or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report
refer only to the sample(s) tested and such sample(s) are retained for 30 days only.


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                                  Report No.: SZEM180500464503
                                                                                                                                  Page      : 13 of 19


QP value: 30MHz~1GHz
Horizontal




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation
of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its
intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery
or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report
refer only to the sample(s) tested and such sample(s) are retained for 30 days only.


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                                  Report No.: SZEM180500464503
                                                                                                                                  Page      : 14 of 19


Vertical




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation
of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its
intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery
or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report
refer only to the sample(s) tested and such sample(s) are retained for 30 days only.


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                                  Report No.: SZEM180500464503
                                                                                                                                  Page      : 15 of 19
Below 1GHz
The test was performed at a 10m test site. According to below formulate and the test data at 10m test
distance,
     L3 / L10 = D10 / D3
          Note:
          L3: Level @ 3m distance. Unit: uV/m;
          L10: Level @ 10m distance. Unit: uV/m;
          D3: 3m distance. Unit: m
          D10: 10m distance. Unit: m
The level at 3m test distance is below:
                             Level @
 Frequency                                           Level @   Level @ 3m Level @ 3m Limit @ 3m                Ant.
                               10m                                                              Margin (dB)
   (MHz)                                            10m (uV/m)   (uV/m)    (dBuV/m)   (dBuV/m)              Polarization
                            (dBuV/m)
      41.86                     13.89                      4.95                     16.50                     24.35                     40.00                     -15.65                        H

     167.24                     14.38                      5.24                     17.45                     24.84                     43.50                     -18.66                        H

     301.42                     16.10                      6.38                     21.28                     26.56                     46.00                     -19.44                        H

     497.68                     20.12                     10.14                     33.80                     30.58                     46.00                     -15.42                        H

     645.12                     23.81                     15.51                     51.69                     34.27                     46.00                     -11.73                        H

     903.31                     27.38                     23.39                     77.96                     37.84                     46.00                      -8.16                        H
      39.16                     21.09                     11.34                     37.79                     31.55                     40.00                      -8.45                        V

      46.34                     20.82                     10.99                     36.63                     31.28                     40.00                      -8.72                        V

     168.41                     20.02                     10.02                     33.41                     30.48                     43.50                     -13.02                        V

     199.29                     19.88                      9.86                     32.88                     30.34                     43.50                     -13.16                        V

     227.69                     20.15                     10.17                     33.91                     30.61                     46.00                     -15.39                        V

     303.54                     24.52                     16.83                     56.09                     34.98                     46.00                     -11.02                        V


  Remark:
1)The field strength is calculated by adding the Antenna Factor, Cable Factor & Preamplifier. The basic
  equation with a sample calculation is as follows:
2)Final Test Level =Receiver Reading + Antenna Factor + Cable Factor – Preamplifier Factor
3)Emissions from 9kHz to 30 MHz is too low to be find, so it is not reported.




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation
of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its
intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery
or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report
refer only to the sample(s) tested and such sample(s) are retained for 30 days only.


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                                  Report No.: SZEM180500464503
                                                                                                                                  Page      : 16 of 19



5.2 20dB Occupy Bandwidth
           Test Requirement:                                47 CFR Part 15C
           Test Method:                                     ANSI C63.10:2013 Section 7.8.7
           Test Setup:




           Limit:                                           NA
          Final Test Mode:                                  Transmitting mode
           Instruments Used:                                Refer to section 5.10 for details
           Test Results:                                    Pass




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation
of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its
intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery
or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report
refer only to the sample(s) tested and such sample(s) are retained for 30 days only.


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                                  Report No.: SZEM180500464503
                                                                                                                                  Page      : 17 of 19

Measurement Data

          Test channel                                                                              20dB Occupy Bandwidth (kHz)

             10.54MHz                                                                                                         548


                                                                                                    * RBW 10 kHz                  Delta 1 [T1 ]
                                                                                                    * VBW 30 kHz                             -0.16 dB
                      Ref -20 dBm                                  * Att        0 dB                  SWT 10 ms                      548.000000000 kHz
                       -20                                                                                                        Marker 1 [T1 ]
                                                                                                                                            -67.83                    dBm
                                                                                                                                      10.302000000                    MHz        A
                       -30
                                                                                                                                  Marker 2 [T1 ]
           1 PK
                                                                                                                                            -46.99                    dBm
           VIEW
                       -40                                                                                                            10.501000000                    MHz
                                                                                           2

                       -50



                       -60

                                                1                                                                                               1
                                     D1 -66.99 dBm
                       -70

                                                                                                                                                                               3DB
                       -80



                       -90



                       -100



                       -110


                       -120

                      Center 10.54 MHz                                                    100 kHz/                                                      Span 1 MHz




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation
of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its
intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery
or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report
refer only to the sample(s) tested and such sample(s) are retained for 30 days only.


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                                  Report No.: SZEM180500464503
                                                                                                                                  Page      : 18 of 19

6          Photographs - EUT Test Setup
6.1 Radiatd Emission (30MHz-1000MHz)




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation
of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its
intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery
or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report
refer only to the sample(s) tested and such sample(s) are retained for 30 days only.


                                                           SGS-CSTC Standards Technical Services Co., Ltd.
                                                           Shenzhen Branch
                                                                                                                                  Report No.: SZEM180500464503
                                                                                                                                  Page      : 19 of 19



6.2 Radiated Spurious Emission (Below 30MHz)




                                                                                   - End of the Report -




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation
of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its
intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all
their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery
or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report
refer only to the sample(s) tested and such sample(s) are retained for 30 days only.



Document Created: 2018-07-27 02:14:48
Document Modified: 2018-07-27 02:14:48

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC