Test Report

FCC ID: 2AG8M-SP13

Test Report

Download: PDF
FCCID_4355554

                                  SGS-CSTC Standards Technical Services Co., Ltd.
                                  Shenzhen Branch




                                                                     Report No.: SZEM190601492902
                                                                     Page:        1 of 30


                                    TEST REPORT
Application No.:                SZEM1906014929CR
Applicant:                      Shenzhen Trainertec Electronic Co., Ltd
Address of Applicant:           4F, 1Blg, Dezhong Industry Park, Bantian District, Shenzhen, China
Manufacturer:                   Shenzhen Trainertec Electronic Co., Ltd
Address of Manufacturer:        4F, 1Blg, Dezhong Industry Park, Bantian District, Shenzhen, China
Equipment Under Test (EUT):
EUT Name:                       remote spray dog training collar
Model No.:                      SP13, SP14, SP15      ♣
♣                               Please refer to section 2 of this report which indicates which model was
                                actually tested and which were electrically identical.
FCC ID:                         2AG8M-SP13
Standard(s) :                   47 CFR Part 15, Subpart C 15.231
Date of Receipt:                2019-06-06
Date of Test:                   2019-06-07 to 2019-06-14
Date of Issue:                  2019-06-18
Test Result:                    Pass*
* In the configuration tested, the EUT complied with the standards specified above.




             Keny Xu
       EMC Laboratory Manager


                           SGS-CSTC Standards Technical Services Co., Ltd.
                           Shenzhen Branch
                                                           Report No.: SZEM190601492902
                                                           Page:       2 of 30



                                        Revision Record
     Version       Chapter               Date                 Modifier       Remark

     01                              2019-06-18                              Original




Authorized for issue by:




                             Bill Chen /Project Engineer




                             Eric Fu /Reviewer


                              SGS-CSTC Standards Technical Services Co., Ltd.
                              Shenzhen Branch
                                                                 Report No.: SZEM190601492902
                                                                 Page:       3 of 30



2   Test Summary
    Radio Spectrum Technical Requirement
             Item               Standard              Method                 Requirement           Result
                        47 CFR Part 15,                                 47 CFR Part 15, Subpart
    Antenna Requirement                                  N/A                                        Pass
                        Subpart C 15.231                                      C 15.203
    N/A: Not applicable

    Radio Spectrum Matter Part
             Item               Standard              Method                 Requirement           Result
                             47 CFR Part 15,    ANSI C63.10 (2013)      47 CFR Part 15, Subpart
       20dB Bandwidth                                                                               Pass
                             Subpart C 15.231      Section 6.9               C 15.231(c)
         Dwell Time          47 CFR Part 15,    ANSI C63.10 (2013)      47 CFR Part 15, Subpart
                                                                                                    Pass
         (15.231(a))         Subpart C 15.231     Section 7.8.4              C 15.231(a)
     Field Strength of the
                             47 CFR Part 15,    ANSI C63.10 (2013)     47 CFR Part 15C Section
     Fundamental Signal                                                                             Pass
                             Subpart C 15.231      Section 6.5               15.231(b)
          (15.231(b))
                             47 CFR Part 15,    ANSI C63.10 (2013)     47 CFR Part 15C Section
     Radiated Emissions                                                                             Pass
                             Subpart C 15.231   Section 6.4&6.5&6.6      15.231(b) and 15.209
    N/A: Not applicable

    Declaration of EUT Family Grouping:
    Model No.: SP13, SP14, SP15
    Only the model SP13 was tested, since the electrical circuit design, layout, components used, internal
    wiring and functions were identical for the above models, with only difference on appearance with color
    and logo(trade mark).


                                                            SGS—CSTC Standards Technical Services Co., Ltd.
                                                            Shenzhen Branch

                                                                                                                               Report No.: SZEM190601492902
                                                                                                                               Page:                    4 of 30



3              Contents
                                                                                                                                                                                             Page
1           COVER PAGE ...... ... cccncneeeenener en en nererereeen en en nen en eb nen en en nen en en nenenerereenen en e neneneeenenen en en nen en en nen en en nenennnn 1

2           TEST SUMMARY .... ... cce 00e 6e6ereerererere e en erereerererereerer en en nen en en nenenerereenen enb nen en en en nen en en nen en en nen en en nene 3

3           CONTENTS.

4           GENERAL INFORMATION ......... o0 eeeremreereereeermereeermereeermereeermerereeneneereeenmeereeenmeereennnenrenrnne 5
      4.1           DETAILS OF E—ULT ; .. 220 en en en en m en eere en en e en en en en en en en en en en en en en eneve en en evee en enevee en enevneeenenenee n 5
      4.2           Description or Support Units                                                                                                                  .5
      4.3           MEASUREMENT UNCERTAINTY .....                                                                                                                 .5
      4.4           TEST LOCATION                                                                                                                                 .6
      4.5           TEest Faciuty..                                                                                                                               .6
      4.6           DEVIATION FROM STANDARDS.                                                                                                                     .6
      4.7           ABNORMALITIES FROM STANDARD CONDITIONS ..... .. ... . en en en eene m en en en en en en en en en en en en enevnenenenene 6
5           EQUIPMENT LIST ...... .ce eeeremreermmereeermereeermereeermereeermereeermerereenereeenmeeneereeenmeereennmeereeennnenre en 7

6           RADIO SPECTRUM TECHNICAL REQUIREMENT .........0.000000 0e eeermeereeermeeneereennmeerereennmerennmeeren n 9
      6.1           ANTENNA REQUIREMENT ..                                                                                                                                                      .9
            6.1.1        Test Requirement:.....                                                                                                                                                 .9
            6.1.2         CONGIUSION ............l.ccsceereeememereveveerereeeenrereeenerereeenerereeenerereveeneneneneenenennenev en neneveenenenevnenenenevee n 9
7           RADIO SPECTRUM MATTER TEST RESULTS .......... cce eememmeeermnereeermereeermeneereeenmnmeereenmeereennmenrenee 10
      7.1           200B BANDWIDTH....
            7.1.1       EU.T. Operation
            7.1.2     Test S@tup Di@graM ....c.c.cclll
            7.1.3     Measurement Procedure and Data.
      7.2           DweLL Time (15.231(A))
            7.2.1       E.U.T. Operation..
            7.2.2        Test Setup Diagram
            7.2.3      Measurement Procedure and Data.
      7.3           DUTY CYOE .cesn en mm emeenemeemeeennenenee.
      7.4           FIELD STRENGTH OF THE FUNDAMENTAL SighaL (15.231(B)).
            7.4.1       E.U.T. Operation..
            7.4.2        Test Setup Diagram
            7.4.3     Measurement Procedure and Data.
      7.5           RADIATED EMISSIONS ........c.c cce
            7.5.1       EU.T. Operation.....
            7.5.2        Test Setup Diagram                                                                                                 ..
            7.5.3        M@ASUF@M@Nt PrOCB@UU@ @MQ DBIA................cccccceeemerememeemereremeenerereneeneeneneneneneeneneneeneneneneree n 23

8           PHOTOGRAPHS........ ... cecenneeeererererereerererereerererereerererereeren en en nen en en nen en en en nen en nennen en en nenenennenennvnenenennene 30
      8.1           TEST SETUP ... cessn en en eeenenenenrneenen en
      8.2           EUT ConstructionaL DetaiLs (EUT PHotos)



                                           Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed
                                           overleaf, available on request or accessible at http/www.sqs.comen/Terms—and—Conditions.aspx and, for electronic format documents,
                                           Subjectis Tarms and Gonditions for Rleattonte Doouments at MipuJwin.age.comen/Tensang:Gondliionsrterms—0—Dceument.aaps.
                                           Attention is drawn to the limitation of lability, indamnification and Jurisdiction issues defined therein. Any holder of this document is
                                           advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the limits of
                                           Client‘s instructions, If any. The Company‘s sole responsibility is to its Client and this document does not exonerate parties to a
                                           transaction from exereising all their rights and obligations under the transaction documents. This document cannot be reproduced
                                           except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
                        tug 7.             appearance of this document is unlawiul and offendars may be prosecuted to the fullest extent of the law. Unlss otherwise stated the
                         ng Sevicss §      results shown in this test report !eferonl¥lo the sample(s) tested and such sample(s) are retained for 30 days only.
                                           Attention: To check the authenticity of testing /inspection report & certificate, please contact us at telephone: (06—755) 8307 1443
                                 2/
                                  ‘   ds
                                           or email: CN.Doccheck@sgs.com
                                               No.t Wortshop, —10,e Secton, Science 8 Technology Pars Shenzhen, Clina 518057   t (86—755) 26012053 1 (86—758)26710504   wimsgsgroup.com.en
    StowbenBont               Clatormioy       MB +2001— AARchEN—108—S1B                                    #B4i: 518057       t (B6—758)26012053 1 (@6—755) 26710504   sos china@sys.com
                                           t
                                                                                                                                                 Member of the SGS Group (SGS SA)


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                               Report No.: SZEM190601492902
                                                               Page:       5 of 30


4   General Information
4.1 Details of E.U.T.
    Power supply:            Tx:DC 3.0V by 1.5V x 2"AAA" batteries
    Operation Frequency:     433.91MHz
    Modulation Type:         FSK
    Sample Type:             Portable production
    Antenna Type:            Spring Antenna
    Antenna Gain:            1.5dBi


4.2 Description of Support Units
    The EUT has been tested as an independent unit.


4.3 Measurement Uncertainty

      No.                             Item                           Measurement Uncertainty
       1                         Duty cycle                                  ± 0.37%
       2                      20dB Bandwidth                                  ± 3%
       3                         Dwell Time                                   ± 3%
       4                           E-Field                             ± 4.5dB (Below 1GHz)
       5                      RF power density                               ± 2.84dB
                                                                       ± 4.5dB (Below 1GHz)
       6               Radiated Spurious emission test
                                                                       ± 4.8dB (Above 1GHz)
       7                      Temperature test                                ± 1°C
       8                        Humidity test                                 ± 3%
       9                      Supply voltages                                ± 1.5%
       10                             Time                                    ± 3%


                            SGS-CSTC Standards Technical Services Co., Ltd.
                            Shenzhen Branch
                                                               Report No.: SZEM190601492902
                                                               Page:       6 of 30


4.4 Test Location
    All tests were performed at:
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Branch
    No. 1 Workshop, M-10, Middle Section, Science & Technology Park, Shenzhen, Guangdong, China.
    518057.
    Tel: +86 755 2601 2053        Fax: +86 755 2671 0594
    No tests were sub-contracted.
4.5 Test Facility
    The test facility is recognized, certified, or accredited by the following organizations:
    • CNAS (No. CNAS L2929)
    CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
    Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
    Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
    Laboratories) for the competence in the field of testing.
    • A2LA (Certificate No. 3816.01)
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
    American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
    • VCCI
    The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz,
    Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
    Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have
    been registered in accordance with the Regulations for Voluntary Control Measures with Registration
    No.: G-20026, R-14188, C-12383 and T-11153 respectively.
    • FCC –Designation Number: CN1178
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    as an accredited testing laboratory.
    Designation Number: CN1178. Test Firm Registration Number: 406779.
    • Innovation, Science and Economic Development Canada
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    by ISED as an accredited testing laboratory.
    CAB identifier: CN0006.
    IC#: 4620C.
4.6 Deviation from Standards
    None
4.7 Abnormalities from Standard Conditions
    None


                              SGS-CSTC Standards Technical Services Co., Ltd.
                              Shenzhen Branch
                                                                  Report No.: SZEM190601492902
                                                                  Page:       7 of 30



5     Equipment List
20dB Bandwidth
       Equipment            Manufacturer         Model No       Inventory No    Cal Date    Cal Due Date
    DC Power Supply            ZhaoXin           RXN-305D       SEM011-02      2018-09-25    2019-09-24
    Spectrum Analyzer     Rohde & Schwarz           FSP         SEM004-06      2018-09-27    2019-09-26
                                                 JS1120-2
Measurement Software         JS Tonscend                            N/A           N/A           N/A
                                                BT/WIFI V2.
      Coaxial Cable             SGS                 N/A         SEM031-02      2018-07-12    2019-07-11
        Attenuator       Weinschel Associates      WA41         SEM021-09         N/A           N/A
     Signal Generator        KEYSIGHT             N5173B        SEM006-05      2018-09-27    2019-09-26
       Power Meter        Rohde & Schwarz          NRVS         SEM014-02      2018-09-25    2019-09-24


Dwell Time (15.231(a))
       Equipment            Manufacturer         Model No       Inventory No    Cal Date    Cal Due Date
    DC Power Supply            ZhaoXin           RXN-305D       SEM011-02      2018-09-25    2019-09-24
    Spectrum Analyzer     Rohde & Schwarz           FSP         SEM004-06      2018-09-27    2019-09-26
                                                 JS1120-2
Measurement Software         JS Tonscend                            N/A           N/A           N/A
                                                BT/WIFI V2.
      Coaxial Cable             SGS                 N/A         SEM031-02      2018-07-12    2019-07-11
        Attenuator       Weinschel Associates      WA41         SEM021-09         N/A           N/A
     Signal Generator        KEYSIGHT             N5173B        SEM006-05      2018-09-27    2019-09-26
       Power Meter        Rohde & Schwarz          NRVS         SEM014-02      2018-09-25    2019-09-24


Field Strength of the Fundamental Signal (15.231(b))
       Equipment            Manufacturer         Model No       Inventory No    Cal Date    Cal Due Date
    3m Semi-Anechoic
                           ETS-LINDGREN             N/A         SEM001-01      2017-08-05    2020-08-04
        Chamber
                                                e3 V8.2014-6-
Measurement Software           AUDIX                                N/A           N/A           N/A
                                                     27
      Coaxial Cable             SGS                 N/A         SEM025-01      2018-07-12    2019-07-11
    EMI Test Receiver    Agilent Technologies     N9038A        SEM004-05      2018-09-25    2019-09-24
    BiConiLog Antenna
                           ETS-LINDGREN            3142C        SEM003-01      2017-06-27    2020-06-26
      (26-3000MHz)
      Pre-amplifier
                         Agilent Technologies      8447D        SEM005-01      2019-04-01    2020-03-31
     (0.1-1300MHz)


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                                 Report No.: SZEM190601492902
                                                                 Page:       8 of 30



RE in Chamber
   Test Equipment          Manufacturer         Model No.      Inventory No.   Cal. Date    Cal. Due date
  3m Semi-Anechoic
                         ETS-LINDGREN              N/A          SEM001-01      2017-08-05    2020-08-04
      Chamber
  MXE EMI Receiver
                        Agilent Technologies     N9038A         SEM004-05      2018-09-25    2019-09-24
   (20Hz-8.4GHz)
  BiConiLog Antenna
                         ETS-LINDGREN             3142C         SEM003-01      2017-06-27    2020-06-26
    (26-3000MHz)
     Pre-amplifier
                        Agilent Technologies      8447D         SEM005-01      2019-04-01    2020-03-31
    (0.1-1300MHz)
                                               e3 V8.2014-6-       N/A
Measurement Software          AUDIX                                               N/A           N/A
                                                    27
    Coaxial Cable              SGS                 N/A          SEM025-01      2018-07-12    2019-07-11


General used equipment
     Equipment             Manufacturer         Model No       Inventory No     Cal Date    Cal Due Date
                             Shanghai
Humidity/ Temperature
                           Meteorological         ZJ1-2B        SEM002-03      2018-09-27    2019-09-26
      Indicator
                          Industry Factory
                             Shanghai
Humidity/ Temperature
                           Meteorological         ZJ1-2B        SEM002-04      2018-09-27    2019-09-26
      Indicator
                          Industry Factory
Humidity/ Temperature
                              Mingle               N/A          SEM002-08      2018-09-27    2019-09-26
      Indicator
                            Changchun
      Barometer            Meteorological         DYM3          SEM002-01      2019-04-04    2020-04-03
                          Industry Factory


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Shenzhen Branch
                                                                  Report No.: SZEM190601492902
                                                                  Page:       9 of 30



6    Radio Spectrum Technical Requirement
6.1 Antenna Requirement
6.1.1 Test Requirement:
      47 CFR Part 15, Subpart C 15.203

6.1.2 Conclusion
      Standard Requirement:
      An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
      responsible party shall be used with the device. The use of a antenna that uses a unique coupling to
      the intentional radiator, the manufacturer may design the unit permanently attached antenna or of an
      so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or
      electrical connector is prohibited.

      EUT Antenna:

      The antenna is integrated on the main PCB and no consideration of replacement. The best case gain
      of the antenna is 1.5dBi

      Antenna location: Refer to Appendix(Internal photos)


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                               Report No.: SZEM190601492902
                                                               Page:       10 of 30



7    Radio Spectrum Matter Test Results
7.1 20dB Bandwidth
     Test Requirement        47 CFR Part 15, Subpart C 15.231(c)
     Test Method:            ANSI C63.10 (2013) Section 6.9
     Limit:

           Frequency range(MHz)                                      Limit
                   70-900                         No wider than 0.25% of the center frequency
                 Above 900                         No wider than 0.5% of the center frequency



7.1.1 E.U.T. Operation
      Operating Environment:
      Temperature:      24.6 °C      Humidity: 53.5 % RH           Atmospheric Pressure: 1005   mbar
      Test mode         a:TX mode_Keep the EUT in transmitting with modulation mode.
7.1.2 Test Setup Diagram




7.1.3 Measurement Procedure and Data


                                     SGS-CSTC Standards Technical Services Co., Ltd.
                                     Shenzhen Branch
                                                                                 Report No.: SZEM190601492902
                                                                                 Page:       11 of 30



       Test channel                        20dB Bandwidth (KHz)                      Limit (KHz)              Results
        433.91MHz                                86.218                               1084.775                 Pass

Mode:a
                                                        * RBW 3 kHz            Delta 1 [T1 ]
                                                        * VBW 10 kHz                       0.02 dB
       Ref    10 dBm               * Att    10 dB         SWT 25 ms                86.217948720 kHz

        10                                                                     Marker 1 [T1 ]
                                                                                         -34.79   dBm
        0
                                                                                  433.865710256   MHz   A
                                                                               Marker 2 [T1 ]
1 PK                                                                                     -14.50   dBm
VIEW
        -10                                                                       433.944235897   MHz
                                                                       2


        -20



        -30
                               1                                           1
                D1 -34.5 dBm

        -40

                                                                                                        3DB
        -50



        -60



        -70



        -80


        -90

       Center   433.9093 MHz                        20 kHz/                           Span   200 kHz


                                SGS-CSTC Standards Technical Services Co., Ltd.
                                Shenzhen Branch
                                                                    Report No.: SZEM190601492902
                                                                    Page:       12 of 30



7.2 Dwell Time (15.231(a))
      Test Requirement         47 CFR Part 15, Subpart C 15.231(a)
      Test Method:             ANSI C63.10 (2013) Section 7.8.4
      Limit:

                     Device type                                               Limit
                                                             The switch automatically deactivate the
            Manually operated transmitter                 transmitter within not more than 5 seconds of
                                                                          being released
                                                            Cease transmission within 5 seconds after
           Automatically actived transmitter
                                                                             activation
Periodic transmissions to determine system integrity of    The total transmission time does not exceed
  transmitters used in security or safety applications                  2 seconds per hour



7.2.1 E.U.T. Operation
      Operating Environment:
      Temperature:      24.6 °C      Humidity: 53.5 % RH           Atmospheric Pressure: 1005             mbar
      Test mode         a:TX mode_Keep the EUT in transmitting with modulation mode.
7.2.2 Test Setup Diagram




7.2.3 Measurement Procedure and Data


                                               SGS—CSTC Standards Technical Services Co., Ltd.
                                               Shenzhen Branch

                                                                                                                  Report No.:              SZEM190601492902
                                                                                                                  Page:                    13 of 30

                Test item                                                        Limit (MHz)                                                           Results
             Transmitting time                                                        <55                                                                  Pass


®                                                                              rew 1 nz
                                                                            *vBw       3    Miz
       Ref     10   dBm                    att          10    ds               SwT     10    s

        10


       Eo                                                                                                                                         jEs
                                                                                                                                                    sor

BB >
       bE—ro

       F—20




                                                                                                                                                    30B




       bozo                                paroureAc antiytovl ulc sAupudt udhlucntnicer


       ——80



        ~80

       Center    433.9093   MHz                                         1   s/




                             Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed
                             overleaf, available on request or accessible at http/www.sqs.comen/Terms—and—Conditions.aspx and, for electronic format documents,
                             Subjectis Tarms and Gonditions for Rleattonte Doouments at MipuJwin.age.comen/Tens ang: Gondliionsrterms—0—             Dceument.aaps.
                             Aitanton is draen to the Imitation or eptly, indamniization and juredieton ‘esuse deined therein, Any holder of this dooumant is
                             advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the limits of
                             Client‘s instructions, if any. The Company‘s sole responsibilty is to its Client and this document does not exonerate parties to a
                             transaction from exereising all their rights and obligations under the transaction documents. This document cannot be reproduced
                             except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
                             appearanceof this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the
                             results shown in this test report refer only to the sample() tested and such sample(s) are retained for 30 days only.
                             Attention: To check the authenticity of testing /inspection report & certificate, please contact us at telephone: (06—755) 8307 1443
                             or email: CN.Doccheck@sgs.com
                                  No.t Wortshop, —10,e Secton, Science 8 Technology Pars Shenzhen, Clina 518057   t (86—755) 26012053 1 (86—758)26710504    wimsgsgroup.com.en
                                  B —R0l— ARBRdhEN—108—S1B                                       #B4i: s18057__t (€6—755)26012050_f (@6—755) 26710504       sqschina@sgs.com
                              I
                                                                                                                                    Member of the SGS Group (SGS SA)


                        SGS-CSTC Standards Technical Services Co., Ltd.
                        Shenzhen Branch
                                                            Report No.: SZEM190601492902
                                                            Page:       14 of 30



7.3 Duty Cycle
    Test Requirement:   47 CFR Part 15C Section 15.35 (c)
    Test Method:        ANSI C63.10:2013
    Test Setup:




    Limit:              N/A
    Test Mode:          Transmitting mode
    Instruments Used:   Refer to section 5 for details
    Test Results:       Pass


                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                             Shenzhen Branch
                                                                                                 Report No.: SZEM190601492902
                                                                                                 Page:       15 of 30



Test plot as follows:
Duty cycle numbers
                                                       RBW 3 MHz
                                                       VBW 10 MHz
         Ref   10 dBm          * Att       10 dB       SWT 200 ms

         10


                                                                                                  A
         0
                                                                                                 SGL
1 PK *
VIEW
         -10



         -20



         -30



         -40

                                                                                                 3DB
         -50



         -60



         -70



         -80


         -90

         Center 433.9093 MHz                       20 ms/




                                                        RBW 3 MHz        Delta 1 [T1 ]
                                                        VBW 10 MHz                  -0.02 dB
         Ref   10 dBm          * Att       10 dB        SWT 100 ms              49.839744 ms

         10                                                              Marker 1 [T1 ]
                                                                                   -17.94   dBm
         0
                                                                                19.230769   ms     A
                                                                         Delta 2 [T1 ]            SGL
1 PK *                                                                              -1.09   dB
VIEW
         -10                                                                    15.705128   ms

                        1              2                             1

         -20



         -30



         -40

                                                                                                  3DB
         -50



         -60



         -70



         -80


         -90

         Center 433.9093 MHz                       10 ms/


                              SGS-CSTC Standards Technical Services Co., Ltd.
                              Shenzhen Branch
                                                                 Report No.: SZEM190601492902
                                                                 Page:       16 of 30



7.4 Field Strength of the Fundamental Signal (15.231(b))
     Test Requirement      47 CFR Part 15, Subpart C 15.231(b)
     Test Method:          ANSI C63.10 (2013) Section 6.5
     Measurement Distance: 3m
     Limit:

        Fundamental                   Field strength of              Field strength of spurious
      frequency(MHz)            fundamental(microvolts/meter)       emissions(microvolts/meter)
        40.66-40.70                           2250                               225
          70-130                              1250                               125
          130-174                         1250 to 3750                        125 to 375
          174-260                             3750                               375
          260-470                        3750 to 12500                       375 to 1250
          Above 470                            12500                            1250
Remark: the emission limit is based on measurement instrumentation employing an average detector
at a distance of 3 meters. The frequencies above 1000MHz are based on average limits. However, the
peak field strength of any emission shall not exceed the maximum permitted average limits specified
above by more than 20 dB under any condition of modulation.


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                              Report No.: SZEM190601492902
                                                              Page:       17 of 30




7.4.1 E.U.T. Operation
      Operating Environment:
      Temperature:      23.7 °C      Humidity: 54.1 % RH           Atmospheric Pressure: 1005   mbar
      Test mode         a:TX mode_Keep the EUT in transmitting with modulation mode.
7.4.2 Test Setup Diagram


                                SGS-CSTC Standards Technical Services Co., Ltd.
                                Shenzhen Branch
                                                                   Report No.: SZEM190601492902
                                                                   Page:       18 of 30

7.4.3 Measurement Procedure and Data
      a. For below 1GHz, the EUT was placed on the top of a rotating table 0.8 meters above the ground at
      a 3 or 10 meter semi-anechoic chamber. The table was rotated 360 degrees to determine the position
      of the highest radiation.
      b. For above 1GHz, the EUT was placed on the top of a rotating table 1.5 meters above the ground at
      a 3 meter fully-anechoic chamber. The table was rotated 360 degrees to determine the position of the
      highest radiation.
      c. The EUT was set 3 or 10 meters away from the interference-receiving antenna, which was
      mounted on the top of a variable-height antenna tower.
      d. The antenna height is varied from one meter to four meters above the ground to determine the
      maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set
      to make the measurement.
      e. For each suspected emission, the EUT was arranged to its worst case and then the antenna was
      tuned to heights from 1 meter to 4 meters (for the test frequency of below 30MHz, the antenna was
      tuned to heights 1 meter) and the rotatable table was turned from 0 degrees to 360 degrees to find
      the maximum reading.
      f. The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum
      Hold Mode.
      g. If the emission level of the EUT in peak mode was 10dB lower than the limit specified, then testing
      could be stopped and the peak values of the EUT would be reported. Otherwise the emissions that
      did not have 10dB margin would be re-tested one by one using peak, quasi-peak or average method
      as specified and then reported in a data sheet.
      h. The radiation measurements are performed in X, Y, Z axis positioning. And found the X axis
      positioning which it is worse case, only the test worst case mode is recorded in the report.
      Remark: Level= Read Level+ Cable Loss+ Antenna Factor- Preamp Factor


                                                      SGS—CSTC Standards Technical Services Co., Ltd.
                                                      Shenzhen Branch

                                                                                                                         Report No.:               SZEM190601492902
                                                                                                                         Page:                     19 of 30


Average value:
                                Average value=Peak value + PDCF
Calculate Formula:               PDCF=20 log(Duty cycle)= 20 log(15.71/49.84)
                                 Duty cycle= T on time / T period
                                Ton time = 15.71ms
    Test data:
                                T period =49.84ms
                                                               new s ane
                                                               vaw 20 w
                                *ace          10 as            sut 200 me




    «s
   Canter 433.9093 iz                                   20 me/




                                                                rew 3 uns                berta 1 (mi j
                                                                vem 10 ie                           ~0.02 as
   Rree   10 azn                 tare          20 as            swz 200 ns                      49.839744 me
                                                                                         wanefs 2 (m])
                                                                                                   —r]. 94

                                                                                                  2 m
                                                                                                         —]. o




    —so
   Center 433,0093 imz                                    10 me/



                                     Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed
                                     overieaf, available on request or accessible at hitp:\wiww.sgs.comen/Terms—and—Conditions.aspx and, for electronic format documents,
                                     Subjectis Tarms and Gonditions for RleattonteMipuJwin.age.comen/Tens
                                                                                            Doouments at                             ang:Gondliionsrterms—0—Dceument.aaps.
                                     Attention is drawn to the limitation of lability, indemnification and jurisdiction issues defined therein. Any holder of this document is
                                     advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the limits of
                                     Client‘s instructions, if any. The Company‘s sole responsibility is to its Client and this document does not exonerate parties to a
                                     fransaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced
                                     except in full, without prior written approval of the Gompany. Any unauthorized alteration, forgery or falsification of the content or
                                     appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the
                                     results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only.
                                     Aftention: To check the authenticity of testing /inspection report & certificate, please contact us at telephone: (86—755) 8307 1443
                                     or email: CN.Doccheck@sgs.com
                               Lid       No.t Wortshap, —10,e Secton, Science 8 Technology Pars Shenzhen, China 518057   t (86—755) 26012053 1 (86—758) 26710504   wimsgsgroup.com.en
                   Clatomioy             MB +2001— AARchEN—108—S1B                                    AB#: s1a057        t (B6—758) 28012058 1 (86—755)26710504    sgs.china@sys.com
                                     t
                                                                                                                                            Member of the SGS Group (SGS SA)


                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                 Shenzhen Branch
                                                                      Report No.: SZEM190601492902
                                                                      Page:       20 of 30


Peak value:
              Cable   Antenna        Preamp       Read                                   Over
Frequency                                                     Level       Limit Line
              Loss     Factor         Factor      Level                                  Limit    Polarization
  (MHz)                                                     (dBuV/m)      (dBuV/m)
               (dB)    (dB/m)          (dB)      (dBuV)                                  (dB)
  433.91      2.35        23.2        27.57      89.85        87.83        100.82        -12.99    Horizontal
  433.91      2.35        23.2        27.57      80.17        78.15        100.82        -22.67      Vertical
Average Value:
Frequency                        Average Level
                 PCDF                             Limit Line (dBuV/m)      Over Limit (dB)        Polarization
  (MHz)                            (dBuV/m)
  433.91                             77.8                 80.82                  -3.02            Horizontal
                 -10.03
  433.91                            68.12                 80.82                  -12.7              Vertical


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                               Report No.: SZEM190601492902
                                                               Page:       21 of 30



7.5 Radiated Emissions
     Test Requirement        47 CFR Part 15, Subpart C Section 15.231 (b)/15.209
     Test Method:          ANSI C63.10 (2013) Section 6.4&6.5&6.6
     Measurement Distance: 3m
     Limit:

                                            Field                         Measurement
       Frequency(MHz)
                                  strength(microvolts/meter)            distance(meters)
         0.009-0.490                      2400/F(kHz)                         300
         0.490-1.705                     24000/F(kHz)                          30
          1.705-30.0                          30                               30
            30-88                             100                                  3
           88-216                             150                                  3
           216-960                            200                                  3
           Above 960                            500                                 3
Remark: The emission limits shown in the above table are based on measurements employing a
CISPR quasi-peak detector except for the frequency bands 9-90kHz, 110-490kHz and above 1000
MHz. Radiated emission limits in these three bands are based on measurements employing an
average detector, the peak field strength of any emission shall not exceed the maximum permitted
average limits specified above by more than 20 dB under any condition of modulation.


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                              Report No.: SZEM190601492902
                                                              Page:       22 of 30


7.5.1 E.U.T. Operation
      Operating Environment:
      Temperature:      20 °C        Humidity: 54 % RH             Atmospheric Pressure: 1005   mbar
      Test mode         a:TX mode_Keep the EUT in transmitting with modulation mode.
7.5.2 Test Setup Diagram


                                SGS-CSTC Standards Technical Services Co., Ltd.
                                Shenzhen Branch
                                                                   Report No.: SZEM190601492902
                                                                   Page:       23 of 30

7.5.3 Measurement Procedure and Data
      a. For below 1GHz, the EUT was placed on the top of a rotating table 0.8 meters above the ground at
      a 3 or 10 meter semi-anechoic chamber. The table was rotated 360 degrees to determine the position
      of the highest radiation.
      b. For above 1GHz, the EUT was placed on the top of a rotating table 1.5 meters above the ground at
      a 3 meter fully-anechoic chamber. The table was rotated 360 degrees to determine the position of the
      highest radiation.
      c. The EUT was set 3 or 10 meters away from the interference-receiving antenna, which was
      mounted on the top of a variable-height antenna tower.
      d. The antenna height is varied from one meter to four meters above the ground to determine the
      maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set
      to make the measurement.
      e. For each suspected emission, the EUT was arranged to its worst case and then the antenna was
      tuned to heights from 1 meter to 4 meters (for the test frequency of below 30MHz, the antenna was
      tuned to heights 1 meter) and the rotatable table was turned from 0 degrees to 360 degrees to find
      the maximum reading.
      f. The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum
      Hold Mode.
      g. If the emission level of the EUT in peak mode was 10dB lower than the limit specified, then testing
      could be stopped and the peak values of the EUT would be reported. Otherwise the emissions that
      did not have 10dB margin would be re-tested one by one using peak, quasi-peak or average method
      as specified and then reported in a data sheet.
      h. The radiation measurements are performed in X, Y, Z axis positioning. And found the X axis
      positioning which it is worse case, only the test worst case mode is recorded in the report.
      Remark: Level= Read Level+ Cable Loss+ Antenna Factor- Preamp Factor


                                                          SGS—CSTC Standards Technical Services Co., Ltd.
                                                          Shenzhen Branch

                                                                                                                                 Report No.:              SZEM190601492902
                                                                                                                                 Page:                    24 of 30



Average value:
                                   Average value=Peak value + PDCF
Calculate Formula:                  PDCF=20 log(Duty cycle)= 20 log(15.71/49.84)=—10.03
                                   Duty cycle= T on time / T period
                                   Ton time = 15.71ms
    Test data:
                                   T period =49.84ms
                                                              son 3 mue
                                                              ver 10 mue
  aet   10 dsn                   rase        10 ce            sez 200 ns




   cso
  Gentee 433. 0003 ie                                  20 ma/

                                                               san 3 ie                oersa i pri d
                                                               vae 10 ine                          —o.02 as
  ses    10 ssn                  tase         10 ce            swz 100 ns                     as.e30704. ns
                                                                                       made   i mJ
                                                                                                  caf.es

                                                                                                   im
                                                                                                        —].0s




   css
  Center 433.0003 ue                                    10 may




                                        Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed
                                        overieaf, available on request or accessible at hitp:\wiww.sgs.comen/Terms—and—Conditions.aspx and, for electronic format documents,
                                        Subjectis Tarms and Gonditions for RleattonteMipuJwin.age.comen/Tens
                                                                                               Doouments at                               ang: Gondliionsrterms—0—    Dceument.aaps.
                                        Aitanton is draen to the Imitation or eptly, indamniization and     therein,
                                                                                                                juredieton ‘esuse deined              Any holder of this dooumant is
                                        advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the limits of
                                        Client‘s instructions, if any. The Company‘s sole responsibility is to its Client and this document does not exonerate parties to a
                                        fransaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced
                                        except in full, without prior written approval of the Gompany. Any unauthorized alteration, forgery or falsification of the content or
   4 eb                                 appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the
                                        results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only.
   P/\msmclm& T!s(mg Seviess J          Aftention: To check the authenticity of testing /inspection report & certificate, please contact us at telephone: (86—755) 8307 1443
                                        or email: CN.Doccheck@sas.com
   Ny                             Lt        No.t Wortshop, M—10, Midde Secton, Scince 8 Technology Par: Shenzhen, Clina 518057
                                            MB +2001— AARchEN—108—S1B                                        AB#: s1a057
                                                                                                                                 t (€6—758)26012058 1 (86—755) 26710504
                                                                                                                                 t (€6—758) 260120581 (@6—755) 26710504
                                                                                                                                                                          winsgegroup.comn
                                                                                                                                                                          sqschina@sgs.com
                                        t
                                                                                                                                                   Member of the SGS Group (SGS SA)


                                SGS-CSTC Standards Technical Services Co., Ltd.
                                Shenzhen Branch
                                                      Report No.: SZEM190601492902
                                                      Page:       25 of 30

30MHz~1GHz
QP value:
Mode: a; Polarization: Horizontal


                                  SGS-CSTC Standards Technical Services Co., Ltd.
                                  Shenzhen Branch
                                                        Report No.: SZEM190601492902
                                                        Page:       26 of 30


Mode: a; Polarization: Vertical


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                   Report No.: SZEM190601492902
                                                   Page:       27 of 30

Above 1GHz
     Mode:a; Polarization:Horizontal


                                SGS-CSTC Standards Technical Services Co., Ltd.
                                Shenzhen Branch
                                                      Report No.: SZEM190601492902
                                                      Page:       28 of 30



Mode:a; Polarization:Vertical


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                                Report No.: SZEM190601492902
                                                                Page:       29 of 30

Remark:
1) The field strength is calculated by adding the Antenna Factor, Cable Factor & Preamplifier. The basic
equation with a sample calculation is as follows:
Final Test Level =Receiver Reading + Antenna Factor + Cable Factor – Preamplifier Factor

2) Scan from 9kHz to 5GHz, the disturbance below 30MHz was very low, and the above harmonics were
the highest point could be found when testing, so only the above harmonics had been displayed. The
amplitude of spurious emissions from the radiator which are attenuated more than 20dB below the limit
need not be reported.
3) As shown in this section, for frequencies above 1GHz, the field strength limits are based on average
limits. However, the peak field strength of any emission shall not exceed the maximum permitted average
limits specified above by more than 20 dB under any condition of modulation. So, only the peak
measurements were shown in the report.


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Shenzhen Branch
                                                                    Report No.: SZEM190601492902
                                                                    Page:       30 of 30



8    Photographs
8.1 Test Setup
Refer to Setup Photos

8.2 EUT Constructional Details (EUT Photos)
Refer to EUT external and internal photos


                                            - End of the Report -



Document Created: 2019-07-11 08:01:32
Document Modified: 2019-07-11 08:01:32

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC