RF Exposure Info 081419

FCC ID: 2AG32MBS31001

RF Exposure Info

Download: PDF
FCCID_4447242

Baicells Technologies Co., Ltd.                                       FCC ID: 2AG32MBS31001



 Environmental evaluation and exposure limit according to FCC CFR
                    47part 1, §1.1307, §1.1310

The calculation was completed to confirm the required safe distance for fixed device.

Based on the calculated r in 2) below, General public cannot be exposed to harmful RF
level in the case of a fixed device is located at least 2 m safe distance from the persons.


Limit for Maximum Permissible Exposure (MPE) to radiofrequency electromagnetic
fields for general population/uncontrolled exposure is 1.0 mW/cm2 (P) for 1,500 -
100,000 MHz frequency range:

The power density P (mW/cm2) = PT / 4𝝅r2, where PT is the maximum equivalent
isotropically radiated power (EIRP).

1) In the transmit mode of 2 carriers with all 4 ports in transmission, the peak output
power of 35.83 dBm with 9 dBi total antenna gain (please refer to Test A.1/A.2 of the
test report 2477ERM.001)

        PT = 35.83 dBm + 9.00 dBi = 44.83 dBm, which is equal to 30,409 mW

The minimum safe distance “r”, where RF exposure does not exceed FCC permissible
limit, is

        r = sqrt {PT / (Px4𝜋)} = sqrt {30,409 / 12.56} = 49.2 cm



Document Created: 2019-09-03 16:34:01
Document Modified: 2019-09-03 16:34:01

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC