RF Exposure Info

FCC ID: 2AG32MBS110596

RF Exposure Info

Download: PDF
FCCID_4472458

Baicells Technologies Co., Ltd.                                      FCC ID: 2AG32MBS110596



 Environmental evaluation and exposure limit according to FCC CFR
                    47part 1, §1.1307, §1.1310

The calculation was completed to confirm the required safe distance for fixed device.

Based on the calculated r in 1) below, General public cannot be exposed to harmful RF
level in the case of a fixed device is located at least 2 m safe distance from the persons.


Limit for Maximum Permissible Exposure (MPE) to radiofrequency electromagnetic
fields for general population/uncontrolled exposure is 1.0 mW/cm2 (P) for 1,500 -
100,000 MHz frequency range:

The power density P (mW/cm2) = PT / 4𝝅r2, where PT is the maximum equivalent
isotropically radiated power (EIRP).

1) The peak output power of 29.65 dBm with 17 dBi total antenna gain (please refer to
Test A.1/A.2 of the test report 2477ERM.005)

        PT = 29.65 dBm + 17.00 dBi = 46.65 dBm, which is equal to 46,238 mW

The minimum safe distance “r”, where RF exposure does not exceed FCC permissible
limit, is

        r = sqrt {PT / (Px4𝜋)} = sqrt {46238 / 12.56} = 61 cm



Document Created: 2019-08-23 19:31:35