                                                                  Report No.: SET2018-12988




             EMC TEST REPORT
      Report No.: SET2018-12988

 Product Name:       PoE Router

          FCC ID: 2AG32EP3011

      Model No. : EP3011

       Applicant: Baicells Technologies Co., Ltd.

                     3F, Hui Yuan Development Building, No.1 Shangdi Information
         Address:
                     Industry Base, Haidian Dist., Beijing, China
  Received Date: 2018-09-21

     Tested Date: 2018-09-25—2018-10-19

       Issued by: CCIC Southern Electronic Product Testing (Shenzhen) Co., Ltd.

   Lab Location: Building 28/29, East of Shigu Xili Industrial Zone, Nanshan District
                 Shenzhen, Guangdong 518055, China
                 Tel: 86 755 26627338      Fax: 86 755 26627238




    This test report consists of 20 pages in total. It may be duplicated completely for legal
use with the approval of the applicant. It should not be reproduced except in full, without
the written approval of our laboratory. The client should not use it to claim product
endorsement by CCIC-SET. The test results in the report only apply to the tested sample.
The test report shall be invalid without all the signatures of testing engineers, reviewer and
approver. Any objections must be raised to CCIC-SET within 15 days since the date when
the report is received. It will not be taken into consideration beyond this limit.




CCIC-SET/T(00)                                                                  Page 1 of 18


                                                                             Report No.: SET2018-12166



                                                 Test Report

Product Name ...................... : PoE Router

Model No. ........................... : EP3011

Applicant .............................. : Baicells Technologies Co., Ltd.

Applicant Address ............... : 3F, Hui Yuan Development Building, No.1 Shangdi
                                           Information Industry Base, Haidian Dist., Beijing, China

Manufacturer........................ : Baicells Technologies Co., Ltd.

Manufacturer Address ........ : 3F, Hui Yuan Development Building, No.1 Shangdi
                                           Information Industry Base, Haidian Dist., Beijing, China

Test Standards ..................... : 47 CFR Part 15 Subpart B: Radio Frequency Devices

Test Result ........................... : PASS
                                                                     2018.10.19
Tested by ............................ :

                                           Yun Lei Fang, Test Engineer
                                                                     2018.10.19
Reviewed by......................... :

                                           Chris You,   Senior Engineer

Approved by ........................ :                               2018.10.19


                                           Zhu Qi, Manager




CCIC-SET/T(00)                                                                           Page 2 of 18


                                                                                                            Report No.: SET2018-12166


                                                    TABLE OF CONTENTS
1.      GENERAL INFORMATION ....................................................................................................4

1.1     EUT Description .........................................................................................................................4
1.2     Test Standards and Results ........................................................................................................5
1.3     Facilities and Accreditations ......................................................................................................6
1.3.1      Facilities ....................................................................................................................................6
1.3.2      Test Environment Conditions ....................................................................................................6
1.3.3      Measurement Uncertainty .........................................................................................................6

2.      TEST CONDITIONS SETTING...............................................................................................7

2.1     Test Peripherals ..........................................................................................................................7
2.2     Test Mode ....................................................................................................................................7
2.3     Test Setup and Equipments List ................................................................................................7
2.3.1      Conducted Emission..................................................................................................................7
2.3.2      Radiated Emission .....................................................................................................................9

3.      47 CFR PART 15B REQUIREMENTS .................................................................................. 11

3.1     Conducted Emission ................................................................................................................. 11
3.1.1      Requirement ............................................................................................................................ 11
3.1.2      Test Description ...................................................................................................................... 11
3.1.3      Test Result ............................................................................................................................... 11
3.2     Radiated Emission ....................................................................................................................14
3.2.1      Requirement ............................................................................................................................14
3.2.2      Test Description ......................................................................................................................15
3.2.3      Test Result ...............................................................................................................................15


                                                                Change History
        Issue                   Date                                                      Reason for change
         1.0                 2018.10.19                                                     First edition




CCIC-SET/T(00)                                                                                                                       Page 3 of 18


                                                                       Report No.: SET2018-12166



1.          GENERAL INFORMATION

1.1         EUT Description
EUT Name ........................... :       PoE Router
FCC ID ................................. :   2AG32EP3011
Trade Name………………..:
                                             BaiCells
Brand Name…………………:
                                      BaiCells
Hardware Version ................. : V1
Software Version .................. : BCE-AP-2.3C
Note1: The EUT is a PoE Router;
Note 2:For a more detailed description, please refer to Specification or User’s Manual supplied by the
       applicant and/or manufacturer.




CCIC-SET/T(00)                                                                          Page 4 of 18


                                                                        Report No.: SET2018-12166


1.2        Test Standards and Results
The objective of the report is to perform testing according to 47 CFR Part 15 Subpart B:

          No.        Identity                       Document Title
          1          47 CFR Part 15                 Radio Frequency Devices
                     Subpart B 2016

Test detailed items/section required by FCC rules and results are as below:

          No.   Section     Description                                              Result
          1     15.107      Conducted Emission                                       PASS
          2     15.109      Radiated Emission                                        PASS

NOTE:

      (1) The EUT has been tested according to 47 CFR Part 15 Subpart B,Class B.The test procedure
      is according to ANSI C63.4:2014.




CCIC-SET/T(00)                                                                             Page 5 of 18


                                                                      Report No.: SET2018-12166


1.3     Facilities and Accreditations

1.3.1   Facilities

CNAS-Lab Code: L1659
CCIC Southern Electronic Product Testing (Shenzhen) Co., Ltd. CCIC is a third party testing
organization accredited by China National Accreditation Service for Conformity Assessment (CNAS)
according to ISO/IEC 17025. The accreditation certificate number is L1659. A 12.8*6.8*6.4 (m) fully
anechoic chamber was used for the radiated spurious emissions test.
FCC-Registration No.: CN5031

CCIC Southern Electronic Product Testing (Shenzhen) Co., Ltd. EMC Laboratory has been registered
and fully described in a report filed with the FCC (Federal Communications Commission). The
acceptance letter from the FCC is maintained in our files. Designation Number: CN5031, valid time
is until December 31, 2018.

NVLAP Lab Code: 201008-0

CCIC-SET is a third party testing organization accredited by NVLAP according to ISO/IEC 17025.
The accreditation certificate number is 201008-0.



1.3.2   Test Environment Conditions

During the measurement, the environmental conditions were within the listed ranges:

 Temperature (°C):                      15°C - 35°C
 Relative Humidity (%):                 25% -75%
 Atmospheric Pressure (kPa):            86kPa-106kPa

1.3.3   Measurement Uncertainty

The uncertainty is calculated using the methods suggested in the "Guide to the Expression of
Uncertainty in Measurement" (GUM) published by ISO.

 Uncertainty of Conducted Emission:     Uc = 3.6 dB (k=2)
 Uncertainty of Radiated Emission:      Uc = 4.5 dB (k=2)




CCIC-SET/T(00)                                                                        Page 6 of 18


                                                                                   Report No.: SET2018-12166



2.      TEST CONDITIONS SETTING

2.1     Test Peripherals
The following is a listing of the EUT and peripherals utilized during the performance of EMC test:

Support Equipment:

            Description            Brand name             Model              Serial No.           FCCID
             Notebook                   ThinkPad          E430C              A131101550            N/A
           Micro SD card                SanDisk               N/A                  N/A             N/A
               Mouse                    Logitech          M100r               25011051             DOC
             POE Load                   BaiCells              N/A                  N/A             N/A

Support Cable:

                    Description               Shield Type           Ferrite Core         Length
               PC Power adapter Cable         Un- shielding             No                1.2m
                    Mouse Cable               Un- shielding             No                1m

2.2     Test Mode
          The EUT configuration of the emission tests is EUT + PC+Power Supply+POE load.

2.3     Test Setup and Equipments List

2.3.1   Conducted Emission




CCIC-SET/T(00)                                                                                    Page 7 of 18


                                                                     Report No.: SET2018-12166




A. Test Setup:



      < 40cm >                 < 80cm >
                                                                          Common
                                                                          Antenna



                   EUT

                                                              Pulse Limiter
     < 80cm >                                      LISN
                                                                          Receiver


                                                                           System
                                                                          Simulator

The EUT is placed on a 0.8m high insulating table, which stands on the grounded conducting floor,
and keeps 0.4m away from the grounded conducting wall. The EUT is connected to the power mains
through a LISN which provides 50Ω/50µH of coupling impedance for the measuring instrument. The
Common Antenna is used for the call between the EUT and the System Simulator (SS). A Pulse
Limiter is used to protect the measuring instrument. The factors of the whole test system are
calibrated to correct the reading.

B. Equipments List:

                                                                       Calibration     Calibration
  Description         Manufacturer         Model        Serial No.
                                                                          Date         Due. Date
 Test Receiver        KEYSIGHT            N9038A      A141202036       2017.12.13      2018.12.13
     LISN        ROHDE&SCHWARZ            ENV216      A140701847       2018.01.08      2019.01.08
     Cable        MATCHING PAD              W7            /            2018.04.01      2019.04.01




CCIC-SET/T(00)                                                                        Page 8 of 18


                                                                    Report No.: SET2018-12166


2.3.2   Radiated Emission

A. Test Setup:

    1) For radiated emissions from 30MHz to1GHz




B. Test Procedure

    The test is performed in a 3m Semi-Anechoic Chamber; the antenna factor, cable loss and so on
    of the site (factors) is calculated to correct the reading. The EUT is placed on a 0.8m high
    insulating Turn Table, and keeps 3m away from the Test Antenna, which is mounted on a
    variable-height antenna master tower.

    For the test Antenna:

1) In the frequency range above 30MHz, Bi-Log Test Antenna (30MHz to 1GHz) and Horn Test
   Antenna (above 1GHz) are used. Test Antenna is 3m away from the EUT. Test Antenna height is
   varied from 1m to 4m above the ground to determine the maximum value of the field strength.
   The emission levels at both horizontal and vertical polarizations should be tested.




CCIC-SET/T(00)                                                                     Page 9 of 18


                                                                 Report No.: SET2018-12166


C. Equipments List:

                                                                     Calibration   Calibration
 Description          Manufacturer         Model        Serial No.
                                                                        Date       Due. Date
 Test Receiver   ROHDE&SCHWARZ            ESIB7        A0501375      2018.08.05    2019.08.05
Semi-Anechoic
                       Albatross        9m*6m*6m       A0412372      2018.05.09    2019.05.09
   Chamber
Test Antenna -
                         ETC            MCTD 2786      A150402239    2018.06.10    2019.06.10
    Bi-Log
Test Antenna –
                 ROHDE&SCHWARZ            HF906        A0304225      2018.05.26    2019.05.26
     Horn
                                        SAC-5MAC
  Anechoic
                       Albatross        12.8x6.8x6.4   A0304210      2018.05.09    2019.05.09
  Chamber
                                             m
                                          MITEQ
  Amplifier
                 ROHDE&SCHWARZ          AFS42-0010     A0509366      2018.06.04    2019.06.04
 1G~18GHz
                                            1800
  Amplifier      Compliance Direction
                                        PAP-0203H      A0509377      2018.06.04    2019.06.04
 20M~3GHz              System
                                        SUCOFLEX
    Cable             SUNHNER                               /        2018.06.04    2019.06.04
                                           100
                                        SUCOFLEX
    Cable             SUNHNER                          MY1758/4      2018.06.04    2019.06.04
                                           104




CCIC-SET/T(00)                                                                 Page 10 of 18


                                                                       Report No.: SET2018-12166



3.       47 CFR PART 15B REQUIREMENTS

3.1      Conducted Emission

3.1.1    Requirement

According to FCC section 15.107, the radio frequency voltage that is conducted back onto the AC
power line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the
following table, as measured using a 50µH/50Ω line impedance stabilization network (LISN).

                                                    Conducted Limit (dBµV)
 Frequency range (MHz)
                                       Quasi-peak                              Average
        0.15 - 0.50                     66 to 56                               56 to 46
         0.50 - 5                          56                                     46
          5 - 30                           60                                     50
Note:
a) The limit subjects to the Class B digital device.
b) The lower limit shall apply at the band edges.
c) The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50MHz.

3.1.2    Test Description

See section 2.3.1 of this report.

3.1.3    Test Result

The maximum conducted interference is searched using Peak (PK), Quasi-peak (QP) and Average
(AV) detectors; the emission levels more than the AV and QP limits, and that have narrow margins
from the AV and QP limits will be re-measured with AV and QP detectors. Tests for both L phase and
N phase lines of the power mains connected to the EUT are performed. All test modes are considered,
refer to recorded points and plots below.

Note:
  Devices subject to Part 15 must be tested for all available U.S. voltages and frequencies (such as a
Nominal 120V AC,50/60Hz) for which the device is capable of operation. A device rated for 50/60
Hz operation need not be tested at both frequencies provided the radiated and line conducted
emissions are the same at both frequencies.




CCIC-SET/T(00)                                                                        Page 11 of 18


                                                                                            Report No.: SET2018-12166


Test voltage and frequency (120V AC,60Hz)

A. Mains terminal disturbance voltage, L phase



         Level in dB¦Ì
        100

         90       177.000 kHz                                                               213.000 kHz
                  47.720 dB¦Ì                           339.000 kHz                         47.845 dB¦Ì
         80                                             48.168 dB¦Ì


         70

                                                                           FCC Part 15 Class B Voltage on Mains QP
         60

                                                                           FCC Part 15 Class B Voltage on Mains AV
         50

         40

         30

         20

         10

          0                                                                              1.014000 MHz
                  505.500 kHz                         685.500 kHz
                  35.606 dB¦Ì                         33.215 dB¦Ì                         31.230 dB¦Ì
         -10



          150k           300   400 500     800 1M           2M        3M    4M 5M 6       8 10M            20M       30M
                                                       Frequency in Hz



                                                    (Plot A: L Phase)

                                Conducted Disturbance at Mains Terminals
                                                      L Test Data
                         QP                                                                    AV
   Frequen                Measurem                               Frequen                        Measurem
                  Limits                        Margin                             Limits                             Margin
      cy                  ent Value                                 cy                           ent Value
                 (dBV)                          (dB)                             (dBV)                               (dB)
    (MHz)                  (dBV)                                 (MHz)                           (dBV)
    0.1770        64.60     44.29                   20.34           0.1770          54.60          35.35               19.28
    0.2130        63.10     45.77                   17.32           0.2130          53.10          38.53               14.56
    0.3390        59.20     46.04                   13.19           0.3390          49.20          38.44               10.79
    0.5055       56.00             32.34            23.66           0.5055          46.00            24.64             21.36
    0.6855       56.00             31.12            24.88           0.6855          46.00            23.79             22.21
    1.0140       56.00             29.73            26.27           1.0140          46.00            22.67             23.33


CCIC-SET/T(00)                                                                                                   Page 12 of 18


                                                                                             Report No.: SET2018-12166


B. Mains terminal disturbance voltage, N phase



         Level in dB¦Ì
         100

                    348.000 kHz                         177.000 kHz
          90                                                                            204.000 kHz
                    41.602 dB¦Ì                         45.848 dB¦Ì                     44.615 dB¦Ì
          80

          70

                                                                            FCC Part 15 Class B Voltage on Mains QP
          60

                                                                            FCC Part 15 Class B Voltage on Mains AV
          50

          40

          30

          20

          10

            0
                   622.500 kHz                    685.500 kHz                                  973.500 kHz
                   30.674 dB¦Ì                    31.007 dB¦Ì                                  30.218 dB¦Ì
         -10



            150k           300    400 500    800 1M           2M       3M    4M 5M 6       8 10M             20M      30M
                                                         Frequency in Hz



                                                  (Plot B: N Phase)

                                   Conducted Disturbance at Mains Terminals
                                                       N Test Data
                        QP                                                          AV
  Frequen                Measureme                                                   Measureme
                 Limits                           Margin           Frequency Limits             Margin
     cy                   nt Value                                                     nt Value
                (dBV)                             (dB)              (MHz)   (dBV)              (dB)
   (MHz)                   (dBV)                                                      (dBV)
   0.1770        64.60      42.08                     22.55          0.1770   54.60     31.75    22.88
   0.2040          63.40             41.25            22.20           0.2040           53.40           31.34                22.11
   0.3480          59.00             40.10            18.91           0.3480           49.00           34.16                14.85
   0.6225          56.00             27.08            28.92           0.6225           46.00           20.02                25.98
   0.6855          56.00             27.79            28.21           0.6855           46.00           20.46                25.54
    0.9735     56.00                 25.33            30.67           0.9735           46.00           18.26                27.74
Test Result: PASS


CCIC-SET/T(00)                                                                                                     Page 13 of 18


                                                                         Report No.: SET2018-12166


3.2        Radiated Emission

3.2.1      Requirement

According to FCC section 15.109, the field strength of radiated emissions from unintentional
radiators at a distance of 3 meters shall not exceed the following values:

        Frequency           Field Strength          Field Strength Limitation at 3m Measurement Dist
      range (MHz)          µV/m            Dist             (uV/m)                  (dBuV/m)
      0.009 - 0.490     2400/F(kHz)       300m       10000* 2400/F(kHz)      20log 2400/F(kHz) + 80
      0.490 - 1.705     2400/F(kHz)        30m        100* 2400/F(kHz)       20log 2400/F(kHz) + 40
      1.705 - 30.00         30             30m              100*30                 20log 30 + 40
       30.0 - 88.0          100             3m                100                    20log 100
       88.0 - 216.0         150             3m                150                    20log 150
      216.0 - 960.0         200             3m                200                    20log 200
      Above 960.0           500             3m                500                    20log 500

      a)     As shown in FCC section 15.35(b), for frequencies above 1000MHz, the field strength
           limits are based on average detector. When average radiated emission measurements are
           specified in this part, including emission measurements below 1000MHz, there also is a limit
           on the radio frequency emissions, as measured using instrumentation with a peak detector
           function, corresponding to 20dB above the maximum permitted average limit for the
           frequency being investigated unless a different peak emission limit is otherwise specified in
           the rules.

      b)    Test Antenna is 3m away from the EUT. Test Antenna height is varied from 1m to 4m
           above the ground to determine the maximum value of the field strength.

      c) For below 1G :QP detector RBW 120kHz ,VBW 300kHz.

      d) For Above 1G: PK detector RBW 1MHz,VBW 3MHz for PK value ;AV detector RBW
         1MHz, VBW 10Hz for AV value.

Note:
1) The tighter limit shall apply at the boundary between two frequency range.
2) Limitation expressed in dBuV/m is calculated by 20log Emission Level(uV/m).
3) If measurement is made at 3m distance, then F.S Limitation at 3m distance is adjusted by using
   the formula of Ld1 = Ld2 * (d2/d1)2.
   Example:
   F.S Limit at 30m distance is 30uV/m, then F.S Limitation at 3m distance is adjusted as
   Ld1 = L1 = 30uV/m * (10)2 = 100 * 30uV/m.




CCIC-SET/T(00)                                                                          Page 14 of 18


                                                                         Report No.: SET2018-12166


3.2.2    Test Description

See section 2.3.2 of this report.

3.2.3    Test Result

The maximum radiated emission is searched using PK, QP and AV detectors; the emission levels
more than the limits, and that have narrow margins from the limits will be re-measured with AV and
QP detectors. Both the vertical and the horizontal polarizations of the Test Antenna are considered to
perform the tests. All test modes are considered, refer to recorded points and plots below.

The amplitude of spurious emissions which are attenuated more than 20 dB below the permissible
value need not be reported.

Note: All radiated emission tests were performed in X, Y, Z axis direction, and only the worst axis test
condition was recorded in this test report.




CCIC-SET/T(00)                                                                          Page 15 of 18


                                                                                            Report No.: SET2018-12166


C. Radiation disturbances, antenna polarization:Vertical

    Marker:                     37.775551 MHz                            37.26 dBµV/m

     Level [dBµV/m]
   80

   70

   60

   50

   40

   30

   20

   10

     0
          30M         50M         70M        100M                     200M       300M          500M        700M        1G
                                                Frequency [Hz]

          MES 18-15100 V2
          LIM FCC Cl.B F QP/AV           FCC ClassB, field strength




                                     (Plot C: Test Antenna Vertical 30M - 1G)


                                                       Antenna
        Frequency     QuasiPeak         Bandwidth                       Limit      Margin
                                                        height                                  Antenna           Verdict
          (MHz)       (dBμV/m)            (kHz)                       (dBμV/m)      (dB)
                                                         (cm)

          30.41         35.66            120.000         208.0          40.00       4.34        Vertical           Pass

          44.07         31.03            120.000         129.0          40.00       8.97        Vertical           Pass

          70.82         32.88            120.000         147.0          43.50       10.62       Vertical           Pass

         148.58         32.51            120.000         241.0          43.50       10.99       Vertical           Pass

         335.19         35.22            120.000         169.0          46.00       10.78       Vertical           Pass

         931.96         37.24            120.000         207.0          46.00       8.76        Vertical           Pass




CCIC-SET/T(00)                                                                                              Page 16 of 18


                                                                                            Report No.: SET2018-12166


D. Radiation disturbances, antenna polarization: Horizontal

    Marker:                 560.681363 MHz                               36.24 dBµV/m

     Level [dBµV/m]
   80

   70

   60

   50

   40

   30

   20

   10

     0
          30M         50M         70M        100M                     200M       300M          500M         700M        1G
                                                Frequency [Hz]

          MES 18-15100 H2
          LIM FCC Cl.B F QP/AV           FCC ClassB, field strength




                                  (Plot D:          Test Antenna Horizontal 30M - 1G)



                                                       Antenna
        Frequency     QuasiPeak         Bandwidth                       Limit      Margin
                                                        height                                  Antenna            Verdict
          (MHz)       (dBμV/m)            (kHz)                       (dBμV/m)      (dB)
                                                         (cm)

          30.00         32.08            120.000         223.0          40.00       7.92       Horizontal           Pass

          72.77         27.79            120.000         209.0          43.50       15.71      Horizontal           Pass

         276.87         29.76            120.000         126.0          43.50       13.74      Horizontal           Pass

         337.13         32.02            120.000         268.0          46.00       13.98      Horizontal           Pass

         560.68         31.55            120.000         214.0          46.00       14.45      Horizontal           Pass

         657.88         36.24            120.000         364.0          46.00       9.76       Horizontal           Pass




Test Result: PASS




CCIC-SET/T(00)                                                                                               Page 17 of 18


                                                                      Report No.: SET2018-12166


E. Radiation disturbances, antenna polarization: Horizontal




                          (Plot E: Test Antenna Horizontal 1G – 18G)

F. Radiation disturbances, antenna polarization: Vertical




                           (Plot F: Test Antenna Vertical 1G – 18G)




CCIC-SET/T(00)                                                                     Page 18 of 18



Document Created: 2018-10-19 17:33:59
Document Modified: 2018-10-19 17:33:59

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC