RF Exposure

FCC ID: 2AG32EG7035LM11

RF Exposure Info

Download: PDF
FCCID_3961821

                                                TEST REPORT
  Reference No. ....................        :   WTS18S07118477-3W

  FCC ID ................................   :   2AG32EG7035LM11

  Applicant ............................    :   Baicells Technologies Co., Ltd.

  Address ..............................    :   3F, Hui Yuan Development Building, No.1 Shangdi Information
                                                Industry Base, Haidian Dist., Beijing, China
  Manufacturer ....................         :   The same as above

  Address ..............................    :   The same as above

  Product...............................    :   LTE Outdoor CPE

  Model(s). ............................    :   EG7035L-M11

  Brand Name .......................        :   BaiCells

  Standards...........................      :   FCC 1.1307

  Date of Receipt sample ....               :   2018-07-18

  Date of Test .......................      :   2018-07-19 to 2018-07-31

  Date of Issue ......................      :   2018-08-03
  Test Result .........................     :   Pass


  Remarks:
  The results shown in this test report refer only to the sample(s) tested, this test report cannot be
  reproduced, except in full, without prior written permission of the company. The report would be invalid
  without specific stamp of test institute and the signatures of compiler and approver.

                                               Prepared By:
                                   Waltek Services (Shenzhen) Co., Ltd.
          Address: 1/F., Fukangtai Building, West Baima Road, Songgang Street, Baoan District,
                                      Shenzhen, Guangdong, China
                                          Tel :+86-755-83551033
                                          Fax:+86-755-83552400

          Compiled by:                                                      Approved by:




          Ford Wang / Project Engineer                                      Philo Zhong / Manager




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn                                   Page 1 of 9


Reference No.: WTS18S07118477-3W                  Page 2 of 9




2     Laboratories Introduction
Waltek Services (Shenzhen) Co., Ltd is a professional third-party testing and certification laboratory with
multi-year product testing and certification experience, established strictly in accordance with ISO/IEC 17025
requirements, and accredited by ILAC (International Laboratory Accreditation Cooperation) member. A2LA
(American Association for Laboratory Accreditation) of USA, Meanwhile, Waltek has got recognition as
registration and accreditation laboratory from EMSD (Electrical and Mechanical Services Department), and
American Energy star, FCC(The Federal Communications Commission), CEC(California energy efficiency),
IC(Industry Canada). It’s the strategic partner and data recognition laboratory of international authoritative
organizations, such as Intertek(ETL-SEMKO), TÜV Rheinland, TÜV SÜD, etc.




Waltek Services (Shenzhen) Co., Ltd is one of the largest and the most comprehensive third party testing
laboratory in China. Our test capability covered four large fields: safety test. Electro Magnetic Compatibility
(EMC), and energy performance, wireless radio. As a professional, comprehensive, justice international test
organization, we still keep the scientific and rigorous work attitude to help each client satisfy the international
standards and assist their product enter into globe market smoothly.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS18S07118477-3W             Page 3 of 9




Test Facility:


      A. Accreditations for Conformity Assessment (International)


        Country/Region        Accreditation Body           Scope                Note
        USA                                                FCC ID \ DOC \ VOC   1
        Canada                                             IC ID \ VOC          2
        Japan                                              MIC-T \ MIC-R        -
                              A2LA
        Europe                                             EMCD \ RED           -
                              (Certificate No.: 4243.01)
        Taiwan                                             NCC                  -
        Hong Kong                                          OFCA                 -
        Australia                                          RCM                  -
        India                                              WPC                  -
        Thailand              International Services       NTC                  -
        Singapore                                          IDA                  -
        Note:
        1.   FCC Designation No.: CN1201. Test Firm Registration No.: 523476.
        2.   IC Canada Registration No.: 7760A

      B. TCBs and Notify Bodies Recognized Testing Laboratory.


        Recognized Testing Laboratory of …                 Notify body number
        TUV Rheinland
        Intertek
                                                           Optional.
        TUV SUD
        SGS
        Phoenix Testlab GmbH                               0700
        Element Materials Technology Warwick Ltd           0891
        Timco Engineering, Inc.                            1177
        Eurofins Product Service GmbH                      0681




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS18S07118477-3W                                         Page 4 of 9



3     Contents
                                                                                                                                                                 Page
1    COVER PAGE ........................................................................................................................................... 1
2    LABORATORIES INTRODUCTION ................................................................................................................... 2
3    CONTENTS ............................................................................................................................................................ 4
4    REVISION HISTORY ............................................................................................................................................ 5
5    GENERAL INFORMATION .................................................................................................................................. 6
     5.1     GENERAL DESCRIPTION OF E.U.T. ................................................................................................................ 6
     5.2     DETAILS OF E.U.T. ......................................................................................................................................... 6
6    TEST SUMMARY .................................................................................................................................................. 7
7    RF EXPOSURE ...................................................................................................................................................... 8
     7.1     REQUIREMENTS............................................................................................................................................... 8
     7.2     THE PROCEDURES / LIMIT................................................................................................................................ 8
     7.3     MPE CALCULATION METHOD ......................................................................................................................... 9




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS18S07118477-3W            Page 5 of 9




4     Revision History

                    Date of
                                                  Date of
Test report No.     Receipt      Date of Test                Purpose    Comment   Approved
                                                   Issue
                    sample

                                  2018-07-19
WTS18S07118
                   2018-07-18     to 2018-07-   2018-08-03   original      -        Valid
    477-3W                             31




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS18S07118477-3W              Page 6 of 9




5     General Information
5.1   General Description of E.U.T.

      Product:                   LTE Outdoor CPE

      Model(s):                  EG7035L-M11

      Model Description:         N/A

      Storage Location:          Internal Storage

      Note:                      N/A

5.2   Details of E.U.T.
                                 LTE Band 43: 3652.5~3697.5MHz
      Operation Frequency:
                                 WiFi 802.11b/g/n HT20: 2412~2462MHz
                                 LTE: QPSK, 16QAM
      Type of Modulation:
                                 WiFi: CCK, OFDM
                                 LTE: Internal antenna
      Antenna installation:
                                 WiFi: Internal antenna
                                 LTE: 10dBi
      Antenna Gain:
                                 WiFi: 0dBi
      Ratings:                   DC 24V, 0.5A




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS18S07118477-3W              Page 7 of 9




6     Test Summary


                      Test Items                        Test Requirement   Result

            Maximum Permissible Exposure
                                                            1.1307(b)(1)   PASS
          (Exposure of Humans to RF Fields)




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS18S07118477-3W                Page 8 of 9




7      RF Exposure
      Test Requirement:                 FCC Part 1.1307
      Test Mode:                        The EUT work in test mode(Tx).
7.1    Requirements

      Systems operating under the provisions of this section shall be operated in a manner that ensures that
      the public is not exposed to radio frequency energy levels in excess limit for maximum permissible
      exposure. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been
      defined as a mobile device whereby a distance of 0.2m normally can be maintained between the user
      and the device.
7.2    The procedures / limit

      FCC Part 1.1307:
      (A) Limits for Occupational / Controlled Exposure
                                                Magnetic Field                       Averaging Time
      Frequency Range       Electric Field                       Power Density (S)
                                                 Strength (H)                          |E|2,|H|2or S
            (MHz)        Strength (E) (V/m)                         (mW/ cm2)
                                                    (A/m)                               (minutes)
           0.3-3.0               614                1.63                 (100)*              6
            3.0-30             1842 / f            4.89 / f          (900 / f)*              6
           30-300                61.4              0.163                  1.0                6
          300-1500                                                       F/300               6
        1500-100,000                                                       5                 6

       (B) Limits for General Population / Uncontrolled Exposure
                                               Magnetic Field                        Averaging Time
      Frequency Range        Electric Field                      Power Density (S)
                                                Strength (H)                          |E|2,|H|2 or S
            (MHz)         Strength (E) (V/m)                        (mW/ cm2)
                                                    (A/m)                               (minutes)
           0.3-1.34              614                1.63                 (100)*             30
           1.34-30              824/f              2.19/f             (180/f)*              30
           30-300                27.5              0.073                  0.2               30
          300-1500                                                    F/1500                30
        1500-100,000                                                      1.0               30
        Note: f = frequency in MHz ;
        *Plane-wave equivalent power density




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS18S07118477-3W                 Page 9 of 9




7.3     MPE Calculation Method

Predication of MPE limit at a given distance




S = power density (in appropriate units, e.g. mW/cm2)
P = power input to the antenna (in appropriate units, e.g., mW).
G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain
factor, is normally numeric gain.
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)


From the peak EUT RF output power, the minimum mobile separation distance, d=30cm, as well as the
gain of the used antenna, the RF power density can be obtained
Remark:


       FCC Part 1.1307:
Mode        Antenna       Antenna Gain Max.Peak Output Peak Output Power Density              Limit of Power
           Gain (dBi)      (numeric)    Power (dBm)    Power (mW)   (mW/cm2)                 Density (mW/cm2)

LTE          10.00          10.000             23.65           231.74          0.205                  1
WiFi          0.00           1.000             14.42            27.67          0.002                  1