Test Report

FCC ID: 2AG32CN6671

Test Report

Download: PDF
FCCID_3088179

                                  FCC PART 15B, CLASS B

                                               TEST REPORT
                                                              For

                            Baicells Technologies Co., Ltd.
  3F, Hui Yuan Development Building, No.1 Shangdi Information Industry Base, Haidian Dist.,
                                      Beijing, China


                                         FCC ID: 2AG32CN6671


              Report Type:                                       Product Type:
              Original Report                                    LTE Indo or CPE



                      Test Engineer:         Rocky Kang


                    Report Number:           RSZ160525009-00A


                        Report Date:         2016-06-16

                                             Bell Hu

                       Reviewed By:          RF Engineer

                        Prepared By:         Bay Area Compliance Laboratories Corp. (Shenzhen)
                                             6/F, the 3rd Phase of WanLi Industrial Building
                                             ShiHua Road, FuTian Free Trade Zone
                                             Shenzhen, Guangdong, China
                                             Tel: +86-755-33320018
                                             Fax: +86-755-33320008
                                             www.baclcorp.com.cn



Note: This test report is prepared for the customer shown above and for the equipment described herein. It may not be duplicated
or used in part without prior written consent from Bay Area Compliance Laboratories Corp.


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                                          Report No.: RSZ160525009-00A




                                                       TABLE OF CONTENTS


GENERAL INFORMATION .......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 TEST FACILITY .............................................................................................................................................................4
SYSTEM TEST CONFIGURATION ..........................................................................................................................5
  DESCRIPTION OF TEST CONFIGURATION ......................................................................................................................5
  EUT EXERCISE SOFTWARE ..........................................................................................................................................5
  SPECIAL ACCESSORIES .................................................................................................................................................5
  EQUIPMENT MODIFICATIONS .......................................................................................................................................5
  SUPPORT EQUIPMENT LIST AND DETAILS ....................................................................................................................5
  EXTERNAL I/O CABLE..................................................................................................................................................6
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................6
SUMMARY OF TEST RESULTS ...............................................................................................................................7
FCC §15.107 – AC LINE CONDUCTED EMISSIONS .............................................................................................8
  APPLICABLE STANDARD ..............................................................................................................................................8
  MEASUREMENT UNCERTAINTY ....................................................................................................................................8
  EUT SETUP ..................................................................................................................................................................8
  EMI TEST RECEIVER SETUP .........................................................................................................................................9
  TEST PROCEDURE ........................................................................................................................................................9
  TEST EQUIPMENT LIST AND DETAILS ...........................................................................................................................9
  CORRECTED FACTOR & MARGIN CALCULATION .........................................................................................................9
  TEST RESULTS SUMMARY ..........................................................................................................................................10
  TEST DATA ................................................................................................................................................................10
FCC §15.109 - RADIATED EMISSIONS .................................................................................................................13
  APPLICABLE STANDARD ............................................................................................................................................13
  MEASUREMENT UNCERTAINTY ..................................................................................................................................13
  EUT SETUP ................................................................................................................................................................13
  EMI TEST RECEIVER SETUP .......................................................................................................................................14
  TEST PROCEDURE ......................................................................................................................................................14
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................15
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................15
  TEST RESULTS SUMMARY ..........................................................................................................................................16
  TEST DATA ................................................................................................................................................................16




FCC Part 15B, Class B                                                                                                                                  Page 2 of 17


Bay Area Compliance Laboratories Corp. (Shenzhen)                           Report No.: RSZ160525009-00A

GENERAL INFORMATION
Product Description for Equipment under Test (EUT)
The Baicells Technologies Co., Ltd.’s product, model number: CN6671(FCC ID: 2AG32CN6671) or the
"EUT" in this report was a LTE Indoor CPE, which was measured approximately: 188 mm (L) x 168 mm
(W) x 75 mm (H), rated with input voltage: DC 12 V from adapter. The highest operation frequency is
3700 MHz.

Adapter Information:
Model: RD1201000-C55-HMG
Input: 100-240V, 50/60Hz, 0.6A Max
Output: 12V-1A

* All measurement and test data in this report was gathered from production sample serial number:
1203000001156TP0069 (Assigned by Applicant). The EUT supplied by the applicant was received on 2016-05-25.


Objective
This test report is prepared on behalf of Baicells Technologies Co., Ltd. in accordance with Part 2-Subpart
J, Part 15-Subparts A and B of the Federal Communication Commissions rules.

The objective of the manufacturer is to determine the compliance of the EUT with FCC Part 15 B.


Related Submittal(s)/Grant(s)
FCC Part 90 TNB and FCC Part 15.247 DTS submissions with FCC ID: 2AG32CN6671.


Test Methodology
All measurements contained in this report were conducted with ANSI C63.4-2014, American National
Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and
Electronic Equipment in the range of 9 kHz to 40 GHz.

All emissions measurement was performed at Bay Area Compliance Laboratories Corp. (Shenzhen). The
radiated testing was performed at an antenna-to-EUT distance of 3 meters.

Measurement uncertainty with radiated emission is 5.81 dB for 30MHz-1GHz, and 4.88 dB for above
1GHz, 1.95dB for conducted measurement.




FCC Part 15B, Class B                                                                         Page 3 of 17


Bay Area Compliance Laboratories Corp. (Shenzhen)                          Report No.: RSZ160525009-00A

Test Facility

The test site used by Bay Area Compliance Laboratories Corp. (Shenzhen) to collect test data is located on
the 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen,
Guangdong, China.

Test site at Bay Area Compliance Laboratories Corp. (Shenzhen) has been fully described in reports
submitted to the Federal Communication Commission (FCC). The details of these reports have been found
to be in compliance with the requirements of Section 2.948 of the FCC Rules on October 31, 2013. The
facility also complies with the radiated and AC line conducted test site criteria set forth in ANSI C63.4-
2014.

The Federal Communications Commission has the reports on file and is listed under FCC Registration No.:
382179. The test site has been approved by the FCC for public use and is listed in the FCC Public Access
Link (PAL) database.




FCC Part 15B, Class B                                                                       Page 4 of 17


Bay Area Compliance Laboratories Corp. (Shenzhen)                            Report No.: RSZ160525009-00A

SYSTEM TEST CONFIGURATION
Description of Test Configuration
The system was configured for testing in a manufacturer testing fashion.
EUT operation mode: working (data transfer+talking)


EUT Exercise Software
No exercise software was used.


Special Accessories
No special accessory.


Equipment Modifications
No modification was made to the EUT tested.


Support Equipment List and Details


       Manufacturer          Description               Model                    Serial Number

           DELL                   PC                VOSTRO 220S                   127BP2X
           DELL             LCD Monitor              E178WFPC         CN-OWY564-64180-7C4-2SQH
           DELL               Keyboard                 L100                CNORH656658907BL05DC
           DELL                  Mouse               MOC5UO                      G1900NKD
           SAST                  Modem               AEM-2100                       0293
          BULL                Receptacle                N/A                         N/A
          Kinhao                 Phone                  N/A                         N/A




FCC Part 15B, Class B                                                                        Page 5 of 17


    Bay Area Compliance Laboratories Corp. (Shenzhen)                                   Report No.: RSZ160525009-00A

    External I/O Cable

                    Cable Description                 Length (m)                From/Port                     To

           Un-shielding Detachable Mouse Cable               1.5                 Host PC                  Mouse

             Shielding Detachable Serial Cable               1.2                 Host PC                  Modem

             Shielding Detachable K/B Cable                  1.5                 Host PC                 Keyboard

             Shielding Detachable VGA Cable                  1.5                 Host PC               LCD Monitor

           Un-shielding Detachable RJ45 Cable                1.0                  EUT                         PC

           Un-shielding Detachable RJ11 Cable                1.5                  EUT                     Phone

            Un-shielding Detachable DC Cable                 1.0                 Modem                Adater of Modem

            Un-shielding Detachable DC Cable                 1.5                  EUT                     Adater


    Block Diagram of Test Setup
    For conducted emission:


AC Mains
                                                                                                                             LISN


               Phone   10cm   Modem           Modem           Monitor            PC            EUT
                              Adapter 10cm            10cm               10cm           10cm           10cm



                                                                                                               Receptacle
                                                                                            Adapter
                                                                                                                            1.0 meter




               Non-Conductive Table
               80 cm above Ground Plane                       Keyboard          Mouse
                                                                         10cm
                                                        1.5 meters




    FCC Part 15B, Class B                                                                                     Page 6 of 17


Bay Area Compliance Laboratories Corp. (Shenzhen)                       Report No.: RSZ160525009-00A

SUMMARY OF TEST RESULTS


                FCC Rules                      Description of Test              Results

                  §15.107                 AC Line Conducted Emissions         Compliance

                  §15.109                      Radiated Emissions             Compliance




FCC Part 15B, Class B                                                                     Page 7 of 17


Bay Area Compliance Laboratories Corp. (Shenzhen)                         Report No.: RSZ160525009-00A

FCC §15.107 – AC LINE CONDUCTED EMISSIONS
Applicable Standard
According to FCC §15.107


Measurement Uncertainty
Input quantities to be considered for conducted disturbance measurements maybe receiver reading,
attenuation of the connection between LISN/ISN and receiver, LISN/ISN voltage division factor,
LISN/ISN VDF frequency interpolation and receiver related input quantities, etc.

Based on CISPR 16-4-2:2011, the expended combined standard uncertainty of conducted disturbance test
at Bay Area Compliance Laboratories Corp. (Shenzhen) is shown as below. And the uncertainty will not
be taken into consideration for the test data recorded in the report

                          Port                             Measurement uncertainty

                        AC Mains                      3.34 dB (k=2, 95% level of confidence)
                         CAT 3                        3.72 dB (k=2, 95% level of confidence)
                         CAT 5                        3.74 dB (k=2, 95% level of confidence)
                         CAT 6                        4.54 dB (k=2, 95% level of confidence)


EUT Setup




The measurement procedure of EUT setup is according with per ANSI C63.4-2014. The related limit was
specified in FCC Part 15.107 Class B.

The spacing between the peripherals was 10 cm.

FCC Part 15B, Class B                                                                          Page 8 of 17


Bay Area Compliance Laboratories Corp. (Shenzhen)                                Report No.: RSZ160525009-00A

EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

                                Frequency Range                         IF B/W
                               150 kHz – 30 MHz                          9 kHz


Test Procedure
During the conducted emission test, the Adater was connected to the first LISN and the other relevant
equipments were conncected to the second LISN.

Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All data was recorded in the Quasi-peak and average detection mode.

Test Equipment List and Details

                                                                                   Calibration    Calibration
    Manufacturer            Description          Model        Serial Number
                                                                                      Date         Due Date
   Rohde & Schwarz       EMI Test Receiver      ESCS30            100176           2016-06-01      2017-05-31
                                                               3560.6650.12-
   Rohde & Schwarz            LISN 1            ENV216                             2015-12-15      2016-12-14
                                                                101613-Yb
    COM-POWER                 LISN 2             LI-200           12208            2015-12-15      2016-12-14
   Rohde & Schwarz       Transient Limiter      ESH3Z2           DE25985           2016-05-14      2017-05-14
   Rohde & Schwarz       CE Test software       EMC 32             V8.53              NCR             NCR
      Ducommun          Conducted Emission
                                                RG-214             CB031           2015-06-15      2016-06-15
     technologies             Cable

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have
been performed in accordance to requirements that traceable to National Primary Standards and International System
of Units (SI).


Corrected Factor & Margin Calculation
The Corrected factor is calculated by adding LISN/ISN VDF (Voltage Division Factor), Cable Loss and
Transient Limiter Attenuation. The basic equation is as follows:
      Correction Factor = LISN VDF + Cable Loss + Transient Limiter Attenuation
The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7 dB means the emission is 7 dB below the limit. The equation for margin
calculation is as follows:
      Margin = Limit – Corrected Amplitude




FCC Part 15B, Class B                                                                             Page 9 of 17


Bay Area Compliance Laboratories Corp. (Shenzhen)                               Report No.: RSZ160525009-00A

Test Results Summary
According to the recorded data in following table, the EUT complied with the FCC Part 15.107, the worst
margin as below:
                           12.7 dB at 0.325110 MHz in the Line conducted mode

Refer to CISPR16-4-2:2011 and CISPR 16-4-1:2009, the measured level is in compliance with the limit if

                                            Lm + U(Lm) ≤ Llim + Ucispr

In BACL., U(Lm) is less than Ucispr, if Lm is less than Llim, it implies that the EUT complies with the limit.

Test Data
     Environmental Conditions

               Temperature:                25℃
          Relative Humidity:               53%
              ATM Pressure:              101.0 kPa

      The testing was performed by Rocky Kang on 2016-06-03.




FCC Part 15B, Class B                                                                             Page 10 of 17


Bay Area Compliance Laboratories Corp. (Shenzhen)                                              Report No.: RSZ160525009-00A


      EUT Operation Mode: working (data transfer+talking)

     AC 120V/60 Hz, Line:


                                                             EMI Auto Test L


                           90

                           80

                           70
                                                                                                                QP
                           60
                                                                                                                AV
            Level in dBμ




                           50

                           40

                           30

                           20

                           10

                           0
                           150k    300   400 500   800 1M           2M     3M     4M 5M 6     8 10M      20M    30M
                                                               Frequency in Hz



                                  Corrected        Correction
         Frequency                                                        Limit             Margin       Detector
                                  Amplitude         Factor
           (MHz)                                                         (dBμV)              (dB)      (PK/Ave./QP)
                                   (dBμV)            (dB)
          0.150000                   50.7             20.0                66.0               15.3              QP
          0.150000                   37.7             20.0                56.0               18.3          Ave.
          0.197500                   44.4             20.0                63.7               19.3              QP
          0.197500                   34.5             20.0                53.7               19.2          Ave.
          0.205500                   45.9             20.0                63.4               17.5              QP
          0.205500                   38.8             20.0                53.4               14.6          Ave.
          0.297470                   41.2             19.9                60.3               19.1              QP
          0.297470                   35.7             19.9                50.3               14.6          Ave.
          0.325110                   41.5             19.9                59.6               18.1              QP
          0.325110                   36.8             19.9                49.5               12.7          Ave.
          1.049510                   34.2             20.0                56.0               21.8              QP
          1.049510                   28.9             20.0                46.0               17.1          Ave.




FCC Part 15B, Class B                                                                                           Page 11 of 17


Bay Area Compliance Laboratories Corp. (Shenzhen)                                             Report No.: RSZ160525009-00A


     AC 120V/60 Hz, Neutral:

                                                            EMI Auto Test N


                           90

                           80

                           70
                                                                                                               QP
                           60
                                                                                                               AV
            Level in dBμ




                           50

                           40

                           30

                           20

                           10

                           0
                           150k    300   400 500   800 1M          2M     3M     4M 5M 6     8 10M      20M    30M
                                                              Frequency in Hz



                                  Corrected        Correction
         Frequency                                                       Limit             Margin       Detector
                                  Amplitude         Factor
           (MHz)                                                        (dBμV)              (dB)      (PK/Ave./QP)
                                   (dBμV)            (dB)
          0.150000                   50.3             20.0               66.0               15.7              QP
          0.150000                   38.4             20.0               56.0               17.6          Ave.
          0.185500                   45.6             20.0               64.2               18.6              QP
          0.185500                   35.6             20.0               54.2               18.6          Ave.
          0.301500                   42.1             19.9               60.2               18.1              QP
          0.301500                   36.7             19.9               50.2               13.5          Ave.
          0.321110                   40.9             19.9               59.7               18.8              QP
          0.321110                   36.4             19.9               49.7               13.3          Ave.
          1.034550                   35.3             20.0               56.0               20.7              QP
          1.034550                   29.6             20.0               46.0               16.4          Ave.
          1.176390                   32.1             20.0               56.0               23.9              QP
          1.176390                   26.9             20.0               46.0               19.1          Ave.

     Note:
     1) Correction Factor =LISN VDF (Voltage Division Factor) + Cable Loss + Transient Limiter Attenuation
     2) Corrected Amplitude = Reading + Correction Factor
     3) Margin = Limit – Corrected Amplitude




FCC Part 15B, Class B                                                                                          Page 12 of 17


Bay Area Compliance Laboratories Corp. (Shenzhen)                            Report No.: RSZ160525009-00A

FCC §15.109 - RADIATED EMISSIONS
Applicable Standard
According to FCC§15.109


Measurement Uncertainty
All measurements involve certain levels of uncertainties, especially in field of EMC. The factors
contributing to uncertainties are spectrum analyzer, cable loss, antenna factor calibration, antenna
directivity, antenna factor variation with height, antenna phase center variation, antenna factor frequency
interpolation, measurement distance variation, site imperfections, mismatch (average), and system
repeatability.

Based on CISPR 16-4-2:2011, the expended combined standard uncertainty of radiation emissions at Bay
Area Compliance Laboratories Corp. (Shenzhen) is 5.81 dB for 30MHz-1GHz and 4.88 dB for above
1GHz, 1.95dB for conducted measurement at antenna port. And the uncertainty will not be taken into
consideration for the test data recorded in the report.

           Frequency                          Polarity                     Measurement uncertainty

                                             Horizontal              4.04 dB (k=2, 95% level of confidence)
        30 MHz~200 MHz
                                               Vertical              4.52 dB (k=2, 95% level of confidence)
                                             Horizontal              4.72 dB (k=2, 95% level of confidence)
         200 MHz~1 GHz
                                               Vertical              5.81 dB (k=2, 95% level of confidence)
          1 GHz~6 GHz                    Horizontal/Vertical         4.64 dB (k=2, 95% level of confidence)
          Above 6 GHz                    Horizontal/Vertical         4.88 dB (k=2, 95% level of confidence)


EUT Setup
Below 1GHz:




FCC Part 15B, Class B                                                                          Page 13 of 17


Bay Area Compliance Laboratories Corp. (Shenzhen)                              Report No.: RSZ160525009-00A


Above 1GHz:




The radiated emission tests were performed in the 3 meters chamber test site, using the setup accordance
with the ANSI C63.4-2014. The specification used was the FCC Part 15.109 Class B limits.

The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the
middle.

The spacing between the peripherals was 10 cm.

EMI Test Receiver Setup
According to FCC 15.33 requirements, the EUT system was measured from 30 MHz to 18.5 GHz.

During the radiated emission test, the EMI test receiver Setup was set with the following configurations:

          Frequency Range            RBW            Video B/W          IF B/W             Detector

         30 MHz – 1000 MHz         100 kHz           300 kHz           120 kHz              QP
                                    1MHz              3 MHz                /                PK
            Above 1 GHz
                                    1MHz               10 Hz               /                Ave.


Test Procedure

Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.
All data was recorded in the Quasi-peak detector mode from 30 MHz to 1 GHz and PK and average
detector modes for frequencies above 1 GHz.




FCC Part 15B, Class B                                                                          Page 14 of 17


Bay Area Compliance Laboratories Corp. (Shenzhen)                               Report No.: RSZ160525009-00A

Test Equipment List and Details

                                                                     Serial        Calibration     Calibration
   Manufacturer             Description             Model
                                                                    Number            Date          Due Date
         HP                 Amplifier            HP8447E          1937A01046        2016-05-06     2017-05-06
  Rohde & Schwarz       EMI Test Receiver           ESCI             101120         2015-12-15     2016-12-14
   Sunol Sciences        Bi-log Antenna             JB1            A040904-2        2014-12-07     2017-12-06
        Mini                Amplifier          ZVA-183-S+         5969001149        2016-04-23     2017-04-23
    A.H. System           Horn Antenna         SAS-200/571             135          2015-08-18     2018-08-17
   Sunol Sciences         Horn Antenna           DRH-118            A052304         2015-12-01     2016-11-30
  Rohde & Schwarz        Signal Analyzer          FSIQ26          8386001028        2015-12-11     2016-12-11
        TDK                  Chamber            Chamber A              2#           2013-10-15     2016-10-15
        TDK                  Chamber            Chamber B              1#           2015-07-23     2016-07-22
         R&S            Auto test Software       EMC32               V9.10             NCR            NCR
      Ducommun                                 UFA210A-1-          MFR64369
                            RF Cable                                                2015-06-15     2016-06-15
     technologies                              4724-30050U         223410-001
      Ducommun
                            RF Cable              104PEA           218124002        2015-06-15     2016-06-15
     technologies
      Ducommun
                            RF Cable              RG-214                1           2015-06-15     2016-06-15
     technologies
      Ducommun
                            RF Cable              RG-214                2           2015-06-15     2016-06-15
     technologies

 * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations
 have been performed in accordance to requirements that traceable to National Primary Standards and International
 System of Units (SI).


Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:

        Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

        Margin = Limit – Corrected Amplitude




FCC Part 15B, Class B                                                                              Page 15 of 17


Bay Area Compliance Laboratories Corp. (Shenzhen)                                    Report No.: RSZ160525009-00A

Test Results Summary
According to the recorded data in following table, the worst margin reading as below:

                                 8.24 dB at 600.01 MHz in the Vertical polarization


Refer to CISPR16-4-2:2011 and CISPR 16-4-1:2009, the measured level complies with the limit if

                                               Lm + U(Lm) ≤ Llim + Ucispr

In BACL., U(Lm) is less than Ucispr, if Lm is less than Llim, it implies that the EUT complies with the limit.


Test Data
     Environmental Conditions

                  Temperature:               25℃
              Relative Humidity:              53%
                 ATM Pressure:             101.0 kPa

     The testing was performed by Rocky Kang on 2016-06-06.

        Operating Mode: Working (data transfer + talking)
30 MHz to 18.5 GHz

                            Receiver            Rx Antenna Corrected Corrected FCC Part 15B
 Frequency                            Turntable
                  Reading  Detector                         Factor Amplitude
   (MHz)                               Degree Height Polar                     Limit  Margin
                  (dBμV) (PK/QP/Ave.)           (m) (H/V) (dB/m) (dBμV/m) (dBμV/m) (dB)
    30.65           31.06          QP           33       1.2      V          -0.5      30.56       40          9.44
    38.97           36.03          QP           33       1.1      V          -6.7      29.33       40         10.67
    58.70           39.02          QP          311       1.2      V         -13.9      25.12       40         14.88
   104.73           36.73          QP          120       1.0      V          -9.4      27.33      43.5        16.17
   149.99           37.75          QP          264       1.0      V          -7.8      29.95      43.5        13.55
   600.01           40.16          QP          250       2.1      V          -2.4      37.76       46          8.24
   1532.7           43.14          PK          227       1.4      H         -10.41     32.73       74         41.27
   1532.7           30.35          Ave.        227       1.4      H         -10.41     19.94       54         34.06

Note:
         1)   Corrected Amplitude = Meter Reading + Correction Factor
         2)   Correction Factor = Antenna Factor + Cable Loss - Amplifier Gain
         3)    Margin = Limit – Corrected Amplitude
         4)    The data below 20dB to the limit was not recorded.


                                          ***** END OF REPORT *****