Test Report_NFC

FCC ID: 2AFZZC3XG

Test Report

Download: PDF
FCCID_4483046

                     Test Report No.: RF190828N005-2


                                                             TEST REPORT
     Applicant                     Xiaomi Communications Co., Ltd.

                                   The Rainbow City of China Resources, NO.68, Qinghe Middle Street, Haidian
     Address
                                   District, Beijing, China


     Manufacturer or
                                   Xiaomi Communications Co., Ltd.
     Supplier

                                   The Rainbow City of China Resources, NO.68, Qinghe Middle Street, Haidian
     Address
                                   District, Beijing, China

     Product                       Mobile Phone

     Brand Name                    Redmi

     Model                         M1908C3XG

     Additional Model &
                        N/A
     Model Difference

     Date of tests                 Aug. 28, 2019 ~ Sep. 24, 2019

     the tests have been carried out according to the requirements of the following standards:

          FCC Part 15, Subpart C, Section 15.225

     CONCLUSION: The submitted sample was found to COMPLY with the test requirement

                           Tested by Andy Zhu                                                           Approved by Glyn He
                   Project Engineer / EMC Department                                            Assistant Manager / EMC Department




                                                                                                             Date: Sep. 26, 2019
     This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at
     http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or
     replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This
     report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or
     representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and
     expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us.
     Measurement uncertainty is only provided upon request for accredited tests. You have 60 days from date of issuance of this report to notify us of any
     material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing
     and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute you unqualified
     acceptance of the completeness of this report, the tests conducted and the correctness of the report contents.



                                                         No. 34, Chenwulu Section, Guantai Rd., Houjie              Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                         Town, Dongguan City,                                       Fax: +86 769 8593 1080
Dongguan Branch
                                                         Guangdong 523942, China                                    Email: customerservice.dg@cn.bureauveritas.com
                                                                             Page 1 of 28                                                              Report Version 1


                     Test Report No.: RF190828N005-2




                                                     TABLE OF CONTENTS
          RELEASE CONTROL RECORD ..................................................................................................... 4
          1     SUMMARY OF TEST RESULTS ............................................................................................. 5
          2      MEASUREMENT UNCERTAINTY ......................................................................................... 5
          3      GENERAL INFORMATION ..................................................................................................... 6
              3.1     GENERAL DESCRIPTION OF EUT .................................................................................... 6
              3.2     DESCRIPTION OF TEST MODES ...................................................................................... 7
                     3.2.1.   CONFIGURATION OF SYSTEM UNDER TEST ...................................................... 7
                     3.2.2.   TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL ........................... 7
              3.3     GENERAL DESCRIPTION OF APPLIED STANDARDS ..................................................... 9
              3.4     DESCRIPTION OF SUPPORT UNITS ................................................................................ 9
          4      TEST TYPES AND RESULTS .............................................................................................. 10
              4.1.       CONDUCTED EMISSION MEASUREMENT ............................................................... 10
                     4.1.1    LIMITS OF CONDUCTED EMISSION MEASUREMENT....................................... 10
                     4.1.2    TEST INSTRUMENTS ............................................................................................ 10
                     4.1.3    TEST PROCEDURES..............................................................................................11
                     4.1.4    DEVIATION FROM TEST STANDARD ....................................................................11
                     4.1.5    TEST SETUP .......................................................................................................... 12
                     4.1.6    EUT OPERATING CONDITIONS ........................................................................... 12
                     4.1.7    TEST RESULTS ...................................................................................................... 13
              4.2.       RADIATED EMISSION AND BANDEDGE MEASUREMENT ....................................... 15
                    4.2.1     LIMITS OF RADIATED EMISSION AND BANDEDGE MEASUREMENT .............. 15
                    4.2.2     TEST INSTRUMENTS ............................................................................................ 16
                    4.2.3     TEST PROCEDURES............................................................................................. 17
                    4.2.4     DEVIATION FROM TEST STANDARD ................................................................... 17
                    4.2.5     TEST SETUP .......................................................................................................... 18
                    4.2.6     EUT OPERATING CONDITIONS ........................................................................... 19
                    4.2.7     TEST RESULTS ...................................................................................................... 19
              4.3.       FREQUENCY TOLERANCE ......................................................................................... 21
                    4.3.1.     LIMIT OF FREQUENCY TOLERANCE ................................................................. 21
                    4.3.2.     TEST INSTRUMENTS ........................................................................................... 21
                    4.3.3.     TEST PROCEDURES ............................................................................................ 22
                    4.3.4.     DEVIATION FROM TEST STANDARD .................................................................. 22
                    4.3.5.     TEST SETUP ......................................................................................................... 22
                    4.3.6.     EUT OPERATING CONDITIONS .......................................................................... 23
                                                      No. 34, Chenwulu Section, Guantai Rd., Houjie              Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                      Town, Dongguan City,                                       Fax: +86 769 8593 1080
Dongguan Branch
                                                      Guangdong 523942, China                                    Email: customerservice.dg@cn.bureauveritas.com
                                                                          Page 2 of 28                                                              Report Version 1


                      Test Report No.: RF190828N005-2


                  4.3.7.       TEST RESULTS ..................................................................................................... 23
               4.4.      20dB BANDWIDTH ....................................................................................................... 24
                  4.4.1       LIMITS OF 20dB BANDWIDTH .............................................................................. 24
                  4.4.2       TEST INSTRUMENTS ............................................................................................ 24
                  4.4.3       TEST PROCEDURE ............................................................................................... 25
                  4.4.4       DEVIATION FROM TEST STANDARD ................................................................... 25
                  4.4.5       TEST SETUP .......................................................................................................... 25
                  4.4.6       EUT OPERATING CONDITION .............................................................................. 26
                  4.4.7       TEST RESULTS ...................................................................................................... 26
          5.     PHOTOGRAPHS OF THE TEST CONFIGURATION ........................................................... 27
          6.     APPENDIX A - MODIFICATIONS RECORDERS FOR                                          ENGINEERING CHANGES TO
                  THE EUT BY THE LAB ......................................................................................................... 28




                                                      No. 34, Chenwulu Section, Guantai Rd., Houjie              Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                      Town, Dongguan City,                                       Fax: +86 769 8593 1080
Dongguan Branch
                                                      Guangdong 523942, China                                    Email: customerservice.dg@cn.bureauveritas.com
                                                                          Page 3 of 28                                                              Report Version 1


                  Test Report No.: RF190828N005-2




                                    RELEASE CONTROL RECORD

            ISSUE NO.               REASON FOR CHANGE                                                  DATE ISSUED

            RF190828N005-2          Original release                                                   Sep. 26, 2019




                                             No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                             Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                             Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                             Page 4 of 28                                                       Report Version 1


                         Test Report No.: RF190828N005-2



          1 SUMMARY OF TEST RESULTS
          The EUT has been tested according to the following specifications:

                                    APPLIED STANDARD: FCC Part 15, Subpart C
           STANDARD
                        TEST TYPE AND LIMIT                            RESULT                      REMARK
            SECTION
          15.207    AC Power Conducted Emission                          PASS      Meet the requirement of limit.
          15.225              The field strength of any
                                                                         PASS      Meet the requirement of limit.
          (a)&(b)&(c)         emissions within the band
                              The field strength of any
          15.225 (d)          emissions appearing outside of             PASS      Meet the requirement of limit.
                              the 13.110-14.010 MHz band

          15.225 (e)          Frequency tolerance                        PASS      Meet the requirement of limit.

          15.215 (c)          20dB Bandwidth                             PASS      Meet the requirement of limit.

          15.203              Antenna Requirement                        PASS      No antenna connector is used.



          2 MEASUREMENT UNCERTAINTY
          Where relevant, the following measurement uncertainty levels have been estimated for
          tests performed on the EUT as specified in CISPR 16-4-2:
                       MEASUREMENT                            FREQUENCY                           UNCERTAINTY
                     Conducted emissions                      9kHz~30MHz                                 2.70dB
                                                             9KHz ~ 30MHz                                2.16dB
                                                            30MHz ~ 1GMHz                                3.83dB
                      Radiated emissions
                                                             1GHz ~ 18GHz                                4.66dB
                                                            18GHz ~ 40GHz                                4.67dB
          This uncertainty represents an expanded uncertainty expressed at approximately the
          95% confidence level using a coverage factor of k=2.




                                          No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                          Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                          Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 5 of 28                                                       Report Version 1


                         Test Report No.: RF190828N005-2



          3 GENERAL INFORMATION

          3.1 GENERAL DESCRIPTION OF EUT
            PRODUCT                                 Mobile Phone
            MODEL NO.                               M1908C3XG
            FCC ID                2AFZZC3XG
            POWER SUPPLY          DC 3.85V from Li-ion Battery or DC 5V from Adapter
            MODULATION TECHNOLOGY NFC
            MODULATION TYPE                         ASK
            OPERATING FREQUENCY                     13.56MHz
            NUMBER OF CHANNEL                       1
            ANTENNA TYPE                            Fixed Internal Antenna
            I/O PORTS                               Refer to user’s manual
                                                    Earphone: Unshielded, Detachable 125cm;
            CABLE SUPPLIED
                                                    USB Cable: Shielded, Detachable 100cm
           NOTES:
          1. For a more detailed features description, please refer to the manufacturer’s specifications or the
             user's manual.
          2. For the test results, the EUT had been tested with all conditions. But only the worst case was shown
             in test report.
          3. The EUT uses following adapters.
                Adapter 1: Manufactured: chenyang
                Brand                MI
                Model                MDY-10-ED
                Input Power          AC 100-240V, 50-60Hz, 0.5A
                Output Power         DC 5V 3A / DC 9V 2A / DC 12V 1.5A
                Power Line           N/A




                                           No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                           Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                           Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                           Page 6 of 28                                                       Report Version 1


                            Test Report No.: RF190828N005—2



          3.2        DESCRIPTION OF TEST MODES

          The EUT only have one channel.
         |        CHANNEL           _| FREQUENCY (MHz) |
         |           4              |       13.56      |

          3.2.1. CONFIGURATION OF SYSTEM UNDER TEST
                      Please see section 5 photograph of the test configuration for reference.


          3.2.2. TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL
          Pre—Scan has been conducted to determine the worst—case mode from all possible
          combinations between available modulations, data rates, XYZ axis and antenna ports
          The worst case was found when positioned on X axis for radiated emission. Following
          channel(s) was (were) selected for the final test as listed below:

                 EUT CONFIGURE |             APPLICABLE TO
                                                                                                                             DESCRIPTION
                     MODE       |   RE   |    FT       | PLC | BW |
             |         A        |   \    |     \       |        V     |        \         |                         Power by Adapter with NFC                              |

                    Where    RE: Radiated Emission                                               FT: Frequency tolerance
                             PLC: Power Line Conducted Emission                                   BW: 20dB Bandwidth




         RADIATED EMISSION TEST:
          K         —Pre—Scan has been conducted to determine the worst—case mode from all possible combinations
                    between available modulations, XYZ axis, antenna ports (if EUT with antenna diversity architecture)
                    and packet type.
          K         Following channel(s) was (were) selected for the final test as listed below.

                         EUT
                     coNnFiguRrE| TtEstED channeL "ES"ED Im;QUENCY                                         MODULATION TYPE                             AxIS
                        MODE                            (MHZ)
                          A      |        4              13.56     |                                                         ASK               |         x           |




                                                   No.     34, Ch         lu       Section,     Guantai Rd., Houji
Bureau Veritas Shenzhen Co., Ltd.                      o. 34,       Chenwulu         Section,    Guantai    Rd.,    Houlle     Tej;. 1g6 769 8998 2098
                                                   T        D                  Cit                                             Fax:. +86 769 8593 1080
Dongguan Branch                                    own, Zongguan Wity, _
                                                   Guangdong 523942, China                                                     Email: customerservice.dg@en.bureauveritas.com

                                                                               Page 7 of 28                                                                       Report Version 1


                         Test Report No.: RF190828N005—2



          FREQUENCY TOLERANCE:

          K     This item includes all test value of each mode, but only includes spectrum plot of worst value of
                each mode.
          K     Pre—Scan has been conducted to determine the worst—case mode from all possible combinations
                between available modulations, antenna ports (if EUT with antenna diversity architecture), and
                packet types.
          KX    —Following channel(s) was (were) selected for the final test as listed below.

                      EUT
                  conFigcurE| TtEstED cHanneL "ES"ED ;RH';QUENCY                          MODULATION TYPE                     AxIS
                     MODE                           (MHZ)
                       A     |        4              13.56       |                                  ASK               |         x           |




          POWER LINE CONDUCTED EMISSION TEST:

          K     —This item includes all test value of each mode, but only includes spectrum plot of worst value of
                each mode.
          K     Pre—Scan has been conducted to determine the worst—case mode from all possible combinations
                between available modulations, antenna ports (if EUT with antenna diversity architecture), and
                packet types.
          KX    —Following channel(s) was (were) selected for the final test as listed below.

                      EUT
                  CconFIguRE| TtEstED cHanneL ES"EP IGRH';QUENCY                          MODULATION TYPE                     AxIS
                     MODE                          (MHZ)
                       A     |        4             13.56        |                                  ASK               |         x           |



          20dB_ BANDWIDTH:

          K     —This item includes all test value of each mode, but only includes spectrum plot of worst value of
                each mode.
          K     Pre—Scan has been conducted to determine the worst—case mode from all possible combinations
                between available modulations, antenna ports (if EUT with antenna diversity architecture), and
                packet types.
          K     Following channel(s) was (were) selected for the final test as listed below.

                      EUT
                  CconFIguRE| TtEstED cHanneL ES"EP I\';RH';QUENCY                        MODULATION TYPE                     AxIS
                     MODE                          (MHZ)
                       A     |        4             13.56          |                                ASK               |         x           |




                                           No. 34, Ch       lu    Section, Guantai Rd., Houji
Bureau Veritas Shenzhen Co., Ltd.              o        enwu‘u      Section,   CGuantal     OUJIC     Tel:. +86 769 8998 2098
                                           T       D             City,                                Fax:. +86 769 8593 1080
Dongguan Branch                             own, Zongguan Wity,          _
                                           Guangdong 523942, China                                    Email: customerservice.dg@en.bureauveritas.com

                                                                 Page 8 of 28                                                            Report Version 1


                         Test Report No.: RF190828N005-2


          TEST CONDITION:

                                                                       TEST VOLTAGE
                 APPLICABLE TO      ENVIRONMENTAL CONDITIONS                                   TESTED BY
                                                                         (SYSTEM)
                        RE               21deg. C, 63%RH             DC 5V From Adapter           Walker
                        FT               25deg. C, 60%RH             DC 5V From Adapter       Robert Cheng
                        PLC              25deg. C, 55%RH             DC 5V From Adapter           Dragon
                        BW               25deg. C, 60%RH             DC 5V From Adapter       Robert Cheng




          3.3      GENERAL DESCRIPTION OF APPLIED STANDARDS

          The EUT is a RF Product. According to the specifications of the manufacturer, it must
          comply with the requirements of the following standards:


          FCC Part 15, Subpart C. Section 15.225
          ANSI C63.10-2013

          All test items have been performed and recorded as per the above standards.
          NOTE: 1. All test items have been performed and recorded as per the above standards.
                       2. It has been verified to comply with the requirements of FCC Part 15, Subpart B, Class B
                          (sDOC). The test report has been issued separately.



          3.4      DESCRIPTION OF SUPPORT UNITS
          The EUT has been tested as a dependent unit together with other necessary
          accessories or support units. The following support units or accessories were used to
          form a representative test configuration during the tests.

           NO.         PRODUCT          BRAND            MODEL NO.                   SERIAL NO.                      FCC ID
            1            N/A              N/A                  N/A                         N/A                          N/A


           NO.                          DESCRIPTION OF THE ABOVE SUPPORT UNITS
            1    N/A




                                           No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                           Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                           Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                           Page 9 of 28                                                       Report Version 1


                         Test Report No.: RF190828N005-2



          4 TEST TYPES AND RESULTS

          4.1. CONDUCTED EMISSION MEASUREMENT

          4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT

             FREQUENCY OF EMISSION (MHz)                                 CONDUCTED LIMIT (dBµV)

                                                                  Quasi-peak                             Average
                             0.15 ~ 0.5                              66 to 56                            56 to 46
                              0.5 ~ 5                                  56                                  46
                               5 ~ 30                                  60                                  50
           NOTES: 1.The lower limit shall apply at the transition frequencies.
                2. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to
                    0.50MHz.
                    3. All emanations from a class A/B digital device or system, including any network of
                       conductors and apparatus connected thereto, shall not exceed the level of field strengths
                       specified above.



          4.1.2 TEST INSTRUMENTS
          Equipment                 Manufacturer      Model No.          Serial No.       Last Cal.          Next Cal.
          EMI Test Receiver        Rohde&Schwarz ESR7                    101494           Mar. 12,19         Mar. 11,20
          Artificial Mains Network Rohde&Schwarz ENV216                  101173           Mar. 12,19         Mar. 11,20
          Artificial Mains Network Rohde&Schwarz ESH3-Z5                 100317           Mar. 13,19         Mar. 12,20
                                   SCHWARZBEC
          Voltage probe                          TK 9421                 TK 9421-176 Jan. 17,19              Jan. 16,20
                                   K
                                                 ADT_Cond_V
          Test software            ADT                                   N/A              N/A                N/A
                                                 7.3.7
           NOTE:
              1. The test was performed in shielded room 553.
              2. The calibration interval of the above test instruments is 12 months. And the calibrations are
                 traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.




                                          No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                          Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                          Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 10 of 28                                                       Report Version 1


                         Test Report No.: RF190828N005-2



          4.1.3 TEST PROCEDURES


            a. The EUT was placed 0.4 meters from the conducting wall of the shielded room
               with EUT being connected to the power mains through a line impedance
               stabilization network (LISN). Other support units were connected to the power
               mains through another LISN. The two LISNs provide 50 ohm/ 50uH of coupling
               impedance for the measuring instrument.

            b. Both lines of the power mains connected to the EUT were checked for maximum
               conducted interference.

            c. The frequency range from 150kHz to 30MHz was searched. Emission levels under
               (Limit - 20dB) was not recorded.

           NOTE: All modes of operation were investigated and the worst-case emissions are reported.



          4.1.4 DEVIATION FROM TEST STANDARD


           No deviation.




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                        Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                        Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 11 of 28                                                       Report Version 1


                         Test Report No.: RF190828N005-2



          4.1.5 TEST SETUP


                                      V e r tic a l G r o u n d
                                      R e f e r e n c e P la n e                                           Te s t R e c e iv e r


                                       EUT
                     40cm




                                                                      80cm
                      L IS N



                                                                                      H o r iz o n ta l G r o u n d
                                                                                       R e f e r e n c e P la n e

                       N o t e : 1 .S u p p o r t u n its w e r e c o n n e c te d t o s e c o n d L IS N .
                                2 .B o t h o f L IS N s ( A M N ) a r e 8 0 c m f r o m E U T a n d a t le a s t 8 0
                                    f r o m o th e r u n its a n d o t h e r m e ta l p la n e s



           For the actual test configuration, please refer to the attached file (Test Setup Photo).




          4.1.6 EUT OPERATING CONDITIONS

              a.     Turned on the power and connected of all equipment.
              b.     EUT was operated according to the type used was description in
                     manufacturer’s specifications or the User's Manual.




                                              No. 34, Chenwulu Section, Guantai Rd., Houjie    Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                              Town, Dongguan City,                             Fax: +86 769 8593 1080
Dongguan Branch
                                              Guangdong 523942, China                          Email: customerservice.dg@cn.bureauveritas.com
                                                              Page 12 of 28                                                       Report Version 1


                         Test Report No.: RF190828N005-2


          4.1.7 TEST RESULTS
           CONDUCTED WORST-CASE DATA:
             PHASE                          Line                              6dB BANDWIDTH                  9kHz



                                 Corr.        Reading Value       Emission Level                 Limit                    Margin
                     Freq.
              No                Factor          [dB (uV)]           [dB (uV)]                  [dB (uV)]                   (dB)
                     [MHz]
                                 (dB)
                                               Q.P.      AV.       Q.P.        AV.        Q.P.          AV.         Q.P.          AV.
               1    0.16800         10.21     33.74      9.93     43.95       20.14      65.06         55.06       -21.11       -34.92
               2    0.22445         10.21     30.90     12.03     41.11       22.24      62.65         52.65       -21.54       -30.41
               3    0.50484         10.22     25.03      7.45     35.25       17.67      56.00         46.00       -20.75       -28.33
               4    0.55959         10.22     26.76     12.28     36.98       22.50      56.00         46.00       -19.02       -23.50
               5    1.63275         10.23     17.24      7.75     27.47       17.98      56.00         46.00       -28.53       -28.02
               6    2.07861         10.22     20.65     11.24     30.87       21.46      56.00         46.00       -25.13       -24.54


          REMARKS: 1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
                  2. "-": The Quasi-peak reading value also meets average limit and
                      measurement with the average detector is unnecessary.
                  3. The emission levels of other frequencies were very low against the limit.
                  4. Margin value = Emission level - Limit value
                  5. Correction factor = Insertion loss + Cable loss
                  6. Emission Level = Correction Factor + Reading Value.




                               Is fundamental frequency signal which can be ignored.




                                               No. 34, Chenwulu Section, Guantai Rd., Houjie    Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                               Town, Dongguan City,                             Fax: +86 769 8593 1080
Dongguan Branch
                                               Guangdong 523942, China                          Email: customerservice.dg@cn.bureauveritas.com
                                                              Page 13 of 28                                                        Report Version 1


                         Test Report No.: RF190828N005-2




             PHASE                       Neutral                          6dB BANDWIDTH                   9kHz



                                 Corr.      Reading Value Emission Level                    Limit                       Margin
                     Freq.
              No                Factor        [dB (uV)]     [dB (uV)]                     [dB (uV)]                      (dB)
                     [MHz]
                                 (dB)
                                              Q.P.      AV.       Q.P.        AV.       Q.P.        AV.           Q.P.           AV.
               1    0.16743         10.00    34.70     14.79     44.70       24.79     65.09       55.09         -20.39        -30.30
               2    0.22386         10.00    30.20     17.26     40.20       27.26     62.67       52.67         -22.47        -25.41
               3    0.33675         10.01    25.00     14.80     35.01       24.81     59.28       49.28         -24.27        -24.47
               4    0.44474         10.02    11.39      0.72     21.41       10.74     56.97       46.97         -35.56        -36.23
               5    0.49039         10.02    11.90     -0.72     21.92        9.30     56.16       46.16         -34.24        -36.86
               6    0.96148         10.03    14.79      3.95     24.82       13.98     56.00       46.00         -31.18        -32.02

          REMARKS: 1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
                  2. "-": The Quasi-peak reading value also meets average limit and
                      measurement with the average detector is unnecessary.
                  3. The emission levels of other frequencies were very low against the limit.
                  4. Margin value = Emission level - Limit value
                  5. Correction factor = Insertion loss + Cable loss
                  6. Emission Level = Correction Factor + Reading Value.




                                    Is fundamental frequency signal which can be ignored.




                                              No. 34, Chenwulu Section, Guantai Rd., Houjie    Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                              Town, Dongguan City,                             Fax: +86 769 8593 1080
Dongguan Branch
                                              Guangdong 523942, China                          Email: customerservice.dg@cn.bureauveritas.com
                                                             Page 14 of 28                                                        Report Version 1


                         Test Report No.: RF190828N005-2



          4.2. RADIATED EMISSION AND BANDEDGE MEASUREMENT

          4.2.1 LIMITS OF RADIATED EMISSION AND BANDEDGE MEASUREMENT

              The field strength of any emissions shall not exceed the following limits:
              (a)15.848mV/m(84dBuV/m) at 30m, within the band 13.553-13.567 MHz;
              (b)334uV/m(50.5dBuV/m) at 30m, within the band 13.410-13.553 MHz and
                13.567-13.710MHz;
              (c)106uV/m(40.5dBuV/m) at 30m, within the band 13.110-13.410 MHz and
                 13.710-14.010MHz;

              The field strength of any emissions appearing outside of the 13.110-14.010 MHz
              band shall not exceed the general radiated emission limits in § 15.209.

                                                 FIELD STRENGTH                  MEASUREMENT DISTANCE
                 FREQUENCIES (MHz)
                                                 (microvolts/meter)                    (meters)

                       0.009 ~ 0.490                  2400/F(kHz)                                  300
                       0.490 ~ 1.705                 24000/F(kHz)                                   30
                        1.705 ~ 30.0                        30                                      30
                           30 ~ 88                         100                                       3
                          88 ~ 216                         150                                       3
                         216 ~ 960                         200                                       3
                         Above 960                         500                                       3
              NOTES:
              1. The lower limit shall apply at the transition frequencies.
              2. Emission level (dBuV/m) = 20 log Emission level (uV/m).
              3. As shown in 15.35(b), for frequencies above 1000MHz, the field strength limits are based on
                 average detector, however, the peak field strength of any emission shall not exceed the maximum
                 permitted average limits, specified above by more than 20dB under any condition of modulation.
               4. The measured field strength was extrapolated to distance 30 meters, using the formula that the
                  limit of field strength varies as the inverse distance square (40dB per decade of distance)

                 Example:
                 13.56MHz = 15848uV/m                         30m
                          = 84dBuV/m                          30m
                          = 84+20log(30/3)2                   3m
                               =    124dBuV/m



                                           No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                           Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                           Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 15 of 28                                                       Report Version 1


                          Test Report No.: RF190828N005-2



          4.2.2 TEST INSTRUMENTS

           9KHz~30MHz
        Equipment                   Manufacturer       Model No.           Serial No.          Last Cal.            Next Cal.
        EMI Test Receiver   Rohde&Schwarz ESR7                             101564              Mar. 12,19           Mar. 11,20
        Active Loop Antenna SCHWARZBECK FMZB 1519B                         1519B-045           May 28,19            May 27,20
        Amplifier           Burgeon       BPA-530                          100210              Apr. 21,19           Apr. 20,20
                                          ADT_Radiated
        Test Software       ADT                                            N/A                 N/A                  N/A
                                          _V8.7.07
             NOTE: 1. The calibration interval of the above test instruments is 12 months and the calibrations are
                         traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.
                      2. The test was performed in 10m Chamber
                      3. The FCC Site Registration No. is 749762.


          30MHz~1GHz
          Equipment                  Manufacturer              Model No.         Serial No.           Last Cal.          Next Cal.
          EMI Test Receiver          Rohde&Schwarz             ESU40             100449               Mar. 12,19 Mar. 11,20
          Bilog Antenna              Teseq                     CBL 6111D         30643                Jun. 23,19 Jun. 22,20
          Amplifier                  Burgeon                   BPA-530           100220               Apr. 21,19 Apr. 20,20
          3m Semi-anechoic
                                     ETS-LINDGREN              9m*6m*6m          NSEMC003             Apr. 21,19 Apr. 20,20
          Chamber
                                                               ADT_Radiated
          Test software              ADT                                    N/A                       N/A                N/A
                                                               _V7.6.15.9.2
          NOTES:
             1. The test was performed in 966 Chamber (a 3m Semi-anechoic chamber).
             2. The calibration interval of the above test instruments are 12 months and the calibrations are
                traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.
             3. The horn antenna is used only for the measurement of emission frequency above1GHz if tested.
               4. The FCC Site Registration No. is 749762.




                                               No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                               Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                               Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                              Page 16 of 28                                                       Report Version 1


                         Test Report No.: RF190828N005-2



          4.2.3 TEST PROCEDURES

          a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a
             3&10 meter semi-anechoic chamber. The table was rotated 360 degrees to
             determine the position of the highest radiation.
          b. The EUT was set 3 meters away from the interference-receiving antenna, which was
             mounted on the top of a variable-height antenna tower.
          c. The antenna is a broadband antenna, and its height is varied from one meter to four
             meters above the ground to determine the maximum value of the field strength. Both
             horizontal and vertical polarizations of the antenna are set to make the
             measurement.
          d. For each suspected emission, the EUT was arranged to its worst case and then the
             antenna was tuned to heights from 1 meter to 4 meters and the rotatable table was
             turned from 0 degrees to 360 degrees to find the maximum reading.
          e. The test-receiver system was set to quasi-peak detect function and specified
             bandwidth with maximum hold mode when the test frequency is below 1 GHz.
          f. During the test, each emission was maximized by: having the EUT continuously
             working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and
             considered typical configuration to obtain worst position, manipulating
             interconnecting cables, For battery operated equipment, the equipment tests shall be
             perform using fresh batteries. The turntable was rotated to maximize the emission
             level.
          g. For below 30MHz, a loop antenna with its vertical plane is place 3m from the EUT
             and rotated about its vertical axis for maximum response at each azimuth about the
             EUT. And the centre of the loop shall be 1m above the ground.

          NOTES:
          1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz for
             Quasi-peak detection at frequency below 1GHz.
          2. The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and video bandwidth is 3MHz
             for Peak detection at frequency above 1GHz.
          3. All modes of operation were investigated and the worst-case emissions are reported.



          4.2.4 DEVIATION FROM TEST STANDARD

          No deviation.

                                         No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                         Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                         Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 17 of 28                                                       Report Version 1


                         Test Report No.: RF190828N005-2




          4.2.5 TEST SETUP

          Below 30MHz test setup




          Below 1GHz test setup

                                                                           Ant. Tower
                                                                                                         1-4m
                                                          3m
                                    EUT

                                                   Turn Table

                            0.8m


                                                        Ground Plane

                                                        Spectrum




          Note: For the actual test configuration, please refer to the attached file (Test Setup Photo).




                                           No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                           Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                           Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 18 of 28                                                       Report Version 1


                         Test Report No.: RF190828N005-2



          4.2.6 EUT OPERATING CONDITIONS

          Set the EUT under transmission condition continuously at specific channel frequency.


          4.2.7 TEST RESULTS

          FIELD STRENGTH (BELOW 30MHZ AT 3M)
                                    Correction     Raw           Emission
                        Freq.                                                      Polarity        Limit                Margin
             No.                     Factor        Value           Level
                       (MHz)                                                      (0° / 90°)     (dBuV/m)                (dB)
                                     (dB/m)       (dBuV)         (dBuV/m)
              1     *13.56(QP)        -10.79       49.31            38.52            0°              124                 -85.48
              2      27.12(QP)        -10.05       40.13            30.08            0°              69.5                -39.42
              3     *13.56(QP)        -10.79        56.9            46.11            90°             124                 -77.89
              4      27.12(QP)        -10.05       39.76            29.71            90°             69.5                -39.79

              REMARKS: 1. Emission level (dBuV/m) = Raw Value (dBuV) + Correction Factor (dB/m).
                       2. Correction Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB).
                            3. The other emission levels were very low against the limit.
                            4. Margin value = Emission level – Limit value.
                            5. " * ": Fundamental frequency.
                            6. For the test results, both 0° and 90° polarizations of the antenna are set to make the
                               measurement, but only the worst case was shown in test report.


                                                               TEST PLOT
            0°                                                         90°




                                           No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                           Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                           Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                          Page 19 of 28                                                       Report Version 1


                           Test Report No.: RF190828N005-2




          BELOW 1GHz WORST-CASE DATA:

          CHANNEL                     Channel 1                   DETECTOR
                                                                                                   Quasi-Peak (QP)
          FREQUENCY RANGE             9KHz ~ 1GHz                 FUNCTION


                             ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                              EMISSION                               ANTENNA          TABLE              RAW          CORRECTION
                  FREQ.                     LIMIT       MARGIN
          NO.                  LEVEL                                  HEIGHT          ANGLE             VALUE           FACTOR
                  (MHz)                   (dBuV/m)       (dB)
                              (dBuV/m)                                  (m)          (Degree)           (dBuV)           (dB/m)
            1      31.39       31.16 QP    40.00          -8.84        2.00 H             209            42.99             -11.83
            2     163.03       21.20 QP    43.50         -22.30        2.00 H             271            38.11            -16.91
            3     201.83       21.53 QP    43.50         -21.97        2.00 H             344            38.65            -17.12
            4     332.09       28.62 QP    46.00         -17.38        2.00 H             345            39.70             -11.08
            5     379.20       25.64 QP    46.00         -20.36        2.00 H             202            35.60             -9.96
            6     424.93       22.46 QP    46.00         -23.54        2.00 H             342            31.37             -8.91
                               ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                              EMISSION                               ANTENNA          TABLE              RAW          CORRECTION
                  FREQ.                     LIMIT       MARGIN
          NO.                  LEVEL                                  HEIGHT          ANGLE             VALUE           FACTOR
                  (MHz)                   (dBuV/m)       (dB)
                              (dBuV/m)                                  (m)          (Degree)           (dBuV)           (dB/m)
            1      34.16       34.07 QP    40.00          -5.93        1.00 V             348            46.37            -12.30
            2      86.81       26.11 QP    40.00         -13.89        1.00 V             119            46.28            -20.17
            3     158.87       23.50 QP    43.50         -20.00        1.00 V             250            40.00            -16.50
            4     315.46       24.17 QP    46.00         -21.83        1.00 V             356            35.67             -11.50
            5     345.94       25.49 QP    46.00         -20.51        1.00 V             103            36.02            -10.53
            6     419.39       25.89 QP    46.00         -20.11        1.00 V             286            34.73             -8.84
          REMARKS:
                 1. Emission level (dBuV/m) = Raw Value (dBuV) + Correction Factor (dB/m).
                 2. Correction Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB).
                 3. The emission levels of other frequencies were less than 20dB margin against the limit.
                 4. Margin value = Emission level – Limit value.




                                          No. 34, Chenwulu Section, Guantai Rd., Houjie     Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                          Town, Dongguan City,                              Fax: +86 769 8593 1080
Dongguan Branch
                                          Guangdong 523942, China                           Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 20 of 28                                                         Report Version 1


                         Test Report No.: RF190828N005-2



          4.3. FREQUENCY TOLERANCE
          4.3.1. LIMIT OF FREQUENCY TOLERANCE
           The frequency tolerance of the carrier signal shall be maintained within +/- 0.01% of
           the operating frequency over a temperature variation of –20 degrees to 50 degrees C
           at normal supply voltage, and for a variation in the primary supply voltage from 85% to
           115% of the rated supply voltage at a temperature of 20 degrees C.

          4.3.2. TEST INSTRUMENTS

          Equipment                 Manufacturer          Model No.        Serial No.         Last Cal.          Next Cal.
          Power Sensor              Keysight              U2021XA          MY55060016         May 22,19          May 21,20
          Power Sensor              Keysight              U2021XA          MY55060018         May 22,19          May 21,20
          Power Meter               Anritsu               ML2495A          1139001            Mar. 12,19         Mar. 11,20
          Power Sensor              Anritsu               MA2411B          1531155            Mar. 12,19         Mar. 11,20
          Digital Multimeter        FLUKE                 15B              A1220010DG         Oct. 17, 18        Oct.16, 19
          Humid & Temp
                                    Haida                 HD-2257          110807201          Nov.15,18          Nov. 14,19
          Programmable Tester
          Oscilloscope              Agilent         DSO9254A               MY51260160         Nov. 09,18         Nov. 08,19
          Signal Analyzer           Rohde & Schwarz FSV7                   102331             May 22,19          May 21,20
          Signal Generator          Agilent               N5183A           MY50140980         Dec. 07,18 Dec. 06,19
          Agile Signal
                                    Agilent               8645A            Agilent            Oct.27, 18         Oct.26, 19
          Generator
          Spectrum Analyzer         Keysight              N9020A           MY55400499         Mar. 12,19         Mar. 11,20
          MXG-B RF Vector
                                    Keysight              N5182B           MY56200288         Dec. 07, 18 Dec. 06, 19
          Signal Generator
          BLUETOOTH
                                    Rohde&Schwarz CBT32                    100811             May 20,19          May 19,20
          TESTER
          Attenuator                MINI                  BW-S10W2+ S130129FGE2 N/A                              N/A
          DC Source                 Keysight              E3642A           MY56146098         N/A                N/A
          NOTES:
             1. The test was performed in RF Oven room.
             2. The calibration interval of the above test instruments is 12 months and the calibrations are
                traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.




                                              No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                              Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                              Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                             Page 21 of 28                                                       Report Version 1


                         Test Report No.: RF190828N005-2




          4.3.3. TEST PROCEDURES

          a) The EUT was placed inside the environmental test chamber and powered by
             nominal DC voltage.
          b) Turn the EUT on and couple its output to a spectrum analyzer.
          c) Turn the EUT off and set the chamber to the highest temperature specified.
          d) Allow sufficient time (approximately 30 min) for the temperature of the chamber to
             stabilize, turn the EUT on and measure the operating frequency after 2, 5, and 10
             minutes.
          e) Repeat step c) and d) with the temperature chamber set to the lowest temperature.
          f)   The test chamber was allowed to stabilize at +20 degree C for a minimum of 30
               minutes. The supply voltage was then adjusted on the EUT from 85% to 115% and
               the frequency record.

          4.3.4. DEVIATION FROM TEST STANDARD

          No deviation.


          4.3.5. TEST SETUP


                                          Temperature


                  Spectrum Analyzer




                                    DC Power Supply




                                              No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                              Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                              Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                             Page 22 of 28                                                       Report Version 1


                         Test Report No.: RF190828N005-2



          4.3.6. EUT OPERATING CONDITIONS


          Set the EUT under transmission condition continuously at specific channel frequency.

          4.3.7. TEST RESULTS

                                               FREQUEMCY STABILITY VERSUS TEMP.

                                    0 MINUTE                2 MINUTE                  5 MINUTE                     10 MINUTE

        TEMP. POWER Measured Frequency Measured Frequency Measured Frequency Measured Frequency
              SUPPLY
         (℃)         Frequency  Drift  Frequency   Drift  Frequency   Drift  Frequency   Drift
                (V)

                              (MHz)            %        (MHz)          %          (MHz)           %            (MHz)              %

          50    120V/60Hz   13.55996     -0.00029      13.55997     -0.00022    13.55996       -0.00029       13.55996        -0.00029

          40    120V/60Hz   13.56006      0.00044      13.56006     0.00044     13.56007       0.00052        13.56007        0.00052

          30    120V/60Hz   13.56001      0.00007      13.56000     0.00000     13.56000       0.00000        13.56000        0.00000

          20    120V/60Hz   13.56002      0.00015      13.56002     0.00015     13.56002       0.00015        13.56001        0.00007

          10    120V/60Hz   13.56006      0.00044      13.56005     0.00037     13.56006       0.00044        13.56006        0.00044

           0    120V/60Hz   13.56006      0.00044      13.56006     0.00044     13.56006       0.00044        13.56006        0.00044

          -10   120V/60Hz   13.56003      0.00022      13.56002     0.00015     13.56003       0.00022        13.56003        0.00022

          -20   120V/60Hz   13.56005      0.00037      13.56005     0.00037     13.56005       0.00037        13.56005        0.00037




                                           FREQUEMCY STABILITY VERSUS VOLTAGE

                                    0 MINUTE                2 MINUTE                  5 MINUTE                     10 MINUTE

        TEMP. POWER Measured Frequency Measured Frequency Measured Frequency Measured Frequency
              SUPPLY
         (℃)         Frequency  Drift  Frequency   Drift  Frequency   Drift  Frequency   Drift
                (V)

                              (MHz)            %        (MHz)          %          (MHz)           %            (MHz)              %

                102V/60Hz   13.56002     0.00015      13.56002      0.00015     13.56002       0.00015       13.56001         0.00007

          20    120V/60Hz   13.56002      0.00015      13.56002     0.00015     13.56002       0.00015        13.56001        0.00007

                138V/60Hz   13.56002     0.00015      13.56002      0.00015     13.56002       0.00015       13.56001         0.00007




                                               No. 34, Chenwulu Section, Guantai Rd., Houjie    Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                               Town, Dongguan City,                             Fax: +86 769 8593 1080
Dongguan Branch
                                               Guangdong 523942, China                          Email: customerservice.dg@cn.bureauveritas.com
                                                              Page 23 of 28                                                        Report Version 1


                         Test Report No.: RF190828N005-2



          4.4. 20dB BANDWIDTH


          4.4.1 LIMITS OF 20dB BANDWIDTH

           The 20dB bandwidth shall be specified in operating frequency band.(13.11MHz –
             14.01MHz)

          4.4.2 TEST INSTRUMENTS

          Equipment                 Manufacturer          Model No.        Serial No.         Last Cal.          Next Cal.
          Power Sensor              Keysight              U2021XA          MY55060016         May 22,19          May 21,20
          Power Sensor              Keysight              U2021XA          MY55060018         May 22,19          May 21,20
          Power Meter               Anritsu               ML2495A          1139001            Mar. 12,19         Mar. 11,20
          Power Sensor              Anritsu               MA2411B          1531155            Mar. 12,19         Mar. 11,20
          Digital Multimeter        FLUKE                 15B              A1220010DG         Oct. 17, 18        Oct.16, 19
          Humid & Temp
                                    Haida                 HD-2257          110807201          Nov.15,18          Nov. 14,19
          Programmable Tester
          Oscilloscope              Agilent         DSO9254A               MY51260160         Nov. 09,18         Nov. 08,19
          Signal Analyzer           Rohde & Schwarz FSV7                   102331             May 22,19          May 21,20
          Signal Generator          Agilent               N5183A           MY50140980         Dec. 07,18 Dec. 06,19
          Agile Signal
                                    Agilent               8645A            Agilent            Oct.27, 18         Oct.26, 19
          Generator
          Spectrum Analyzer         Keysight              N9020A           MY55400499         Mar. 12,19         Mar. 11,20
          MXG-B RF Vector
                                    Keysight              N5182B           MY56200288         Dec. 07, 18 Dec. 06, 19
          Signal Generator
          BLUETOOTH
                                    Rohde&Schwarz CBT32                    100811             May 20,19          May 19,20
          TESTER
          Attenuator                MINI                  BW-S10W2+ S130129FGE2 N/A                              N/A
          DC Source                 Keysight              E3642A           MY56146098         N/A                N/A
          NOTES:
             1. The test was performed in RF Oven room.
             2. The calibration interval of the above test instruments is 12 months and the calibrations are
                traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.




                                              No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                              Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                              Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                             Page 24 of 28                                                       Report Version 1


                         Test Report No.: RF190828N005-2



          4.4.3 TEST PROCEDURE
            a. Check the calibration of the measuring instrument using either an internal calibrator
               or a known signal from an external generator.
            b. Turn on the EUT and connect it to measurement instrument. Then set it to any one
               convenient frequency within its operating range. Set a reference level on the
               measuring instrument equal to the highest peak value.
            c. Measure the frequency difference of two frequencies that were attenuated 20dB
               from the reference level. Record the frequency difference as the emission
               bandwidth.
            d. Repeat above procedures until all frequencies measured were complete.




          4.4.4 DEVIATION FROM TEST STANDARD

          No deviation.



          4.4.5 TEST SETUP


                          EUT                                               SPECTRUM

                                                 10dB ATTENUATION           ANALYZER
                                                 PAD




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                        Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                        Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 25 of 28                                                       Report Version 1


                         Test Report No.: RF190828N005-2




          4.4.6 EUT OPERATING CONDITION

             The software provided by client to enable the EUT under transmission condition
             continuously.




          4.4.7 TEST RESULTS


                    CHANNEL           CHANNEL FREQUENCY (MHz)                           20dB BANDWIDTH (KHz)

                         1                           13.56                                           25.75


                   Lower & Upper Test Frequency Point               Test Frequency
                                                                                                            P/F
                                 (MHz)                                   (MHz)
                                    Lower                                13.54683                          PASS
                                    Upper                                13.57257                          PASS




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie     Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                        Town, Dongguan City,                              Fax: +86 769 8593 1080
Dongguan Branch
                                        Guangdong 523942, China                           Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 26 of 28                                                         Report Version 1


                         Test Report No.: RF190828N005-2



           5.    PHOTOGRAPHS OF THE TEST CONFIGURATION

          Please refer to the attached file (Test Setup Photo).




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                        Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                        Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 27 of 28                                                       Report Version 1


                         Test Report No.: RF190828N005-2



          6. APPENDIX A - MODIFICATIONS RECORDERS FOR
          ENGINEERING CHANGES TO THE EUT BY THE LAB


           No any modifications are made to the EUT by the lab during the test.




           ---END---




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                        Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                        Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 28 of 28                                                       Report Version 1



Document Created: 2019-10-22 04:57:34
Document Modified: 2019-10-22 04:57:34

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC