RF Exposure Report

FCC ID: 2AFZZ-MDY10EP

RF Exposure Info

Download: PDF
FCCID_4178856

                     Test Report No.: FM190103N022


                                   RF EXPOSURE REPORT
   Applicant                       Xiaomi Communications Co., Ltd.

                                   The Rainbow City of China Resources,NO.68,Qinghe Middle Street,Haidian
   Address
                                   District,Beijing,China


   Manufacturer or
                                   Xiaomi Communications Co., Ltd.
   Supplier
                                   The Rainbow City of China Resources,NO.68,Qinghe Middle Street,Haidian
   Address
                                   District,Beijing,China

   Product                         Mi Wireless Charger

   Brand Name                      MI

   Model                           MDY-10-EP

   Additional Model &
                                   N/A
   Model Difference

   Date of tests                   Jan. 03, 2019 ~ Jan. 18, 2019

        47 CFR PART 1, Subpart I, Section 1.1310
        KDB 680106 D01


   CONCLUSION: The submitted sample was found to COMPLY with the test requirement

                         Tested by Andy Zhu                                                            Approved by Glyn He
                 Project Engineer / EMC Department                                                  Supervisor/ EMC Department




                                                                                                           Date: Jan. 30, 2019
   This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at
   http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or
   replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This
   report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or
   representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and
   expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us.
   Measurement uncertainty is only provided upon request for accredited tests. You have 60 days from date of issuance of this report to notify us of any
   material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing
   and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute you unqualified
   acceptance of the completeness of this report, the tests conducted and the correctness of the report contents.




                                                    No. 34, Chenwulu Section, Guantai Rd., Houjie              Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                    Town, Dongguan City,                                       Fax: +86 769 8593 1080
Dongguan Branch
                                                    Guangdong 523942, China                                    Email: customerservice.dg@cn.bureauveritas.com
                                                                         Page 1 of 8                                                             Report Version 1


                 Test Report No.: FM190103N022




                                    TABLE OF CONTENTS
   RELEASE CONTROL RECORD ................................................................................ 3
   1.       CERTIFICATION .............................................................................................. 4
   2.       DESCRIPTION OF SUPPORT UNITS ............................................................ 5
   2.1       TEST LOCATION ........................................................................................... 5
   2.2       DEVIATION FROM STANDARDS .................................................................. 5
   2.3      ABNORMALITIES FROM STANDARD CONDITIONS ..................................... 5
   3.       EQUIPMENTS USED DURING TEST ............................................................. 5
   4.       TEST RESULTS .............................................................................................. 6
   4.1      RF EXPOSURE TEST ..................................................................................... 6
   4.1.1     EUT OPERATION ........................................................................................... 6
   4.1.2     MEASUREMENT DATA .................................................................................. 7




                                         No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                         Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                         Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                           Page 2 of 8                                                   Report Version 1


                 Test Report No.: FM190103N022



                               RELEASE CONTROL RECORD

    ISSUE NO.                REASON FOR CHANGE                                                      DATE ISSUED

    FM190103N022             Original release                                                         Jan. 30, 2019




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 3 of 8                                                    Report Version 1


                 Test Report No.: FM190103N022


   1. CERTIFICATION

                        FCC ID:     2AFZZ-MDY10EP
                   PRODUCT:         Mi Wireless Charger
              BRAND NAME:           N/A
                        MODEL:      MDY-10-EP
         ADDITIONAL NO.:            N/A
                 APPLICANT:         Xiaomi Communications Co., Ltd.
                                    47 CFR PART 1, Subpart I, Section 1.1310
               STANDARDS:
                                    KDB 680106 D01


   .




                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                     Page 4 of 8                                                    Report Version 1


                 Test Report No.: FM190103N022


   2. DESCRIPTION OF SUPPORT UNITS
   The EUT has been tested with associated equipment below

          Description               Manufacturer                      Model No.                     Serial No.

          Mobile phone                     MI                        M1902F1G                            N/A

          Dummy Load                      N/A                             N/A                            N/A


   Remarks: The support units were provided by client, and worst-case test result was shown on the
   report only.

   Worst Case mode test result shown on the report

   2.1 TEST LOCATION
   All tests were performed at:
   Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch
   No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China
   Tel: +86 769 8593 5656           Fax: +86 769 8593 1080


   2.2 DEVIATION FROM STANDARDS

   None


   2.3 ABNORMALITIES FROM STANDARD CONDITIONS

   None


   3. EQUIPMENTS USED DURING TEST

   Item       Test Equipment           Manufacturer            Model No.         Inventory No.          Car.Due date.
             3m Semi-Anechoic         ETS-LINDGRE
     1                                                        9m*6m*6m           NSEMC003                 2019-03-19
                 Chamber                    N
              Exposure Level
     2                                      Narda               ELT-400               L-0012              2019-11-08
                  Tester
     3          B-field Probe               Narda                 Y2006               L-0017              2019-11-08
   NOTE:     1. The test was performed in RS chamber.
             2. The calibration interval of the above test instruments is 12 months and the calibrations are
                traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.

                                      No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                      Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                      Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                       Page 5 of 8                                                    Report Version 1


                   Test Report No.: FM190103N022


   4. TEST RESULTS

   4.1 RF EXPOSURE TEST
         Test Requirement:                               47 CFR PART 1, Subpart I, Section 1.1310
         Measurement Distance:                           15/20cm
         Test voltage:                                   DC 12V from Adapter input AC 120V/50Hz

         Limit:
      Frequency              Electric field            Magnetic field           Power density                 Averaging time
      range(MHz)            strength (V/m)             strength (A/m)             (mW/cm2)                      (minutes)
                              (A) Limits for Occupational/Controlled Exposures
         0.3-3.0                  614                1.63               *(100)                                          6
         3.0-30                 1842/f              4.89/f            *(900/f2)                                         6
         30-300                  61.4               0.163                 1.0                                           6
        300-1500                      /                         /                     f/300                             6
     1500-100.000                     /                         /                           5                           6
                          (B) Limits for General Population/Uncontrolled Exposure
        0.3-1.34                    614                       1.63                    *(100)                           30
         1.34-30                    824/f                    2.19/f                 *(180/f2)                          30
         30-300                     27.5                     0.073                      0.2                            30
        300-1500                      /                         /                     f/1500                           30

     1500-100.000                     /                         /                       1.0                            30

   F=frequency in MHz
   *=Plane-wave equivalent power density
   RF exposure compliance will need to be determined with respect to 1.1307(c) and (d) of the FCC
   rules. The emissions should be within the limits at 300kHz in Table 1 of 1.1310(use the 300kHz limits
   for 150kHz:614V/m,1.63A/m).



   4.1.1 EUT OPERATION

   Operating Environment:

   Temperature:         24.0°C            Humidity:    52% RH         Atmospheric Pressure: 1015 mbar

   EUT Operation:

   This device has been tested the worst status of full load and the device has been tested with mobile
   phone at zero charge, intermediate charge, and full charge.




                                            No. 34, Chenwulu Section, Guantai Rd., Houjie       Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                            Town, Dongguan City,                                Fax: +86 769 8593 1080
Dongguan Branch
                                            Guangdong 523942, China                             Email: customerservice.dg@cn.bureauveritas.com
                                                             Page 6 of 8                                                        Report Version 1


                 Test Report No.: FM190103N022

   4.1.2 MEASUREMENT DATA

     Output Voltage=DC 15V; The max output power =20W
     Wireless radiation frequency: 110KHz ~ 145KHz

     Electric Field Emissions
                                                                Probe Measure
               Test Position        Test Distance (cm)                                          Limit (V/m)
                                                                 Result (V/m)
                  Side 1                    15                       2.98                            614
                  Side 2                    15                       3.14                            614
                  Side 3                    15                       3.56                            614
                  Side 4                    15                       3.17                            614
                   Top                      20                       5.15                            614
                  Bottom                    15                       2.63                            614

     Magnetic Field Emissions
                                                        Probe Measure
               Test Position        Test Distance (cm)                               Limit (A/m)
                                                          Result (A/m)
                 Side 1                  15                  0.0034                      1.63
                 Side 2                  15                  0.0162                      1.63
                 Side 3                  15                  0.0173                      1.63
                 Side 4                  15                  0.0165                      1.63
                    Top                  20                  0.0267                      1.63
                 Bottom                  15                  0.0098                      1.63
          Note: All modes have been tested and we only record the worst test result in full load mode.




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 7 of 8                                                    Report Version 1


                 Test Report No.: FM190103N022


            PHOTOGRAPHS OF THE TEST CONFIGURATION

   Refer to the Set up photo.




                                    No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                    Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                    Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                     Page 8 of 8                                                    Report Version 1



Document Created: 2019-02-25 18:10:40
Document Modified: 2019-02-25 18:10:40