RF Exposure Report

FCC ID: 2AFWN-SLG-CP101

RF Exposure Info

Download: PDF
FCCID_3497177

                                                                                                                                           FCC ID: 2AFWN-SLG-CP101

                                                  MPE Calculation : Zigbee
                                                                                                                                                     Maximum power
                                     Frequency range        Max Target Power        ANT Gain             Maximum EIRP              Maximum EIRP                      Requriment
     RF function or Mode                                                                                                                                density
                                          (MHz)                   (dBm)               (dBi)                   (dBm)                    (mW)                      2
                                                                                                                                                                           2
                                                                                                                                                                     (mW/cm )
                                                                                                                                                       (mW/cm )
   Transceiver1 (Modem#2)       2405.00      ~    2480.00          6.50               3.90                    10.40                   10.9648           0.0022        1.0000

   Transceiver2 (Modem#4)       2405.00      ~    2480.00          5.50               3.90                       9.40                 8.7097            0.0017        1.0000
                                             ~
                                             ~
                                             ~
                                             ~

                                             ~

                                             ~
                                             ~
Note: Refer to the technical document(operation description) for the max tune-up power.



The EUT will only be used with a separation of 20 centimeters or greater between the antenna and the body of the user.
The MPE sample calculation for this exposure is shown below.
                                   ▪S=       EIRP / ( 4 R2 π )                                          - Note
                                     =         10.9648 / ( 4 X 202 X π )                                S= Maximum power density(mW/cm 2)
                                     =         0.00219 mW/cm2                                           EIRP= Equivalent Isotropic Radiated Power(mW)
                                                                                                        R= Distance to the center of the radiation of the antenna(20cm)
                               ▪ Limits for General Population/Uncontrolled Exposure
                                                              Electric Field      Magnetic field
                                    Frequency range                                                      Power Density            Averageing time
                                                                strength            strength                            2
                                         (MHz)                                                             (mW/cm )                  (minutes)
                                                                  (V/m)              (A/m)
                                   0.3      ~       1.34                   614                  1.63                    *100                    30
                                                                                                                              2
                                  1.34      ~        30                   824/f              2.19 / f              *180 / f                     30
                                   30       ~       300                    27.5                0.073                        0.2                 30
                                   300      ~      1,500                                                            f / 1500                    30

                                  1,500     ~     100,000                                                                   1.0                 30

                               f = frequency in MHz * = Plane-wave equivalent power density

               Conclusion : The exposure condition of this device is compliant with FCC