Test report

FCC ID: 2AFW2B024

Test Report

Download: PDF
FCCID_2785950

                                    Test Report

                                    FCC ID.: 2AFW2B024


                                    Date of issue: Oct. 10, 2015



     Sample Description:                             2.4G keyboard


     Model(s):                                       B020 2.4G, B024 2.4GB0, 27 2.4G, B028 2.4G


     Applicant:                                      Shenzhen DZH Industrial Co., Ltd


     Address:                                        3th Floor, YiTuo Mike Industrial A building, Bu Yong
                                                     Industrial D zone, ShaJing, Shenzhen


     Date of Test:                                   Sep, 12. 2015 to Oct. 09, 2015




                                        Shenzhen Microtest Co., Ltd.
                                          http://www.mtitest.com




This test report is limited to the above client company and the product mode only. It may not be duplicated without prior written consent of
Shenzhen Microtest Co., Ltd.

Tel:(86-755)88850135          Fax: (86-755) 88850136               http://www.mtitest.com                     E-mail: mti@51mti.com
Add: 1F & 3F, East Block,   Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District,        Shenzhen, Guangdong, P. R. China.


                                                                   - Page 2 of 17-             Report No.: MTI150911002RF01


                                              TABALE OF CONTENTS
1. General description ............................................................................................................... 5
1.1 Feature of equipment under test (EUT)............................................................................... 5
1.2 operation channel list ........................................................................................................... 6
2. Test Configuration of EUT .................................................................................................... 7
2.1 Test Frequency Channel ...................................................................................................... 7
2.2 EUT operation mode ............................................................................................................. 7
2.4 Test conditions...................................................................................................................... 7
2.5 Testing site ............................................................................................................................ 7
2.6 Ancillary equipment list........................................................................................................ 7
2.6 Measurement uncertainty .................................................................................................... 7
3. List of test equipment ........................................................................................................... 8
4. Test Result ............................................................................................................................. 9
4.1 Antenna requirement ............................................................................................................ 9
4.2 20dB emission bandwidth .................................................................................................. 10
4.3 Field strength of fundamental, field strength of harmonics, emissions radiated
outside of the specified frequency bands .............................................................................. 12




This test report is limited to the above client company and the product mode only. It may not be duplicated without prior written consent of
Shenzhen Microtest Co., Ltd.

Tel:(86-755)88850135          Fax: (86-755) 88850136               http://www.mtitest.com                     E-mail: mti@51mti.com
Add: 1F & 3F, East Block,   Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District,        Shenzhen, Guangdong, P. R. China.


                                                              - Page 3 of 17-            Report No.: MTI150911002RF01


TEST RESULT CERTIFICATION


Applicant’s name:                             Shenzhen DZH Industrial Co., Ltd
                                              3th Floor, YiTuo Mike Industrial A building, Bu Yong Industrial D
Address:
                                              zone, ShaJing, Shenzhen
Manufacture's Name:                           Shenzhen DZH Industrial Co., Ltd
                                              3th Floor, YiTuo Mike Industrial A building, Bu Yong Industrial D
Address:
                                              zone, ShaJing, Shenzhen
Product description
Product name:                                 2.4G Keyboard
Trademark:                                    千业
Model name:                                   B020 2.4G
Serial Model:                                 B024 2.4G, B027 2.4G, B028 2.4G
Standards:                                    FCC Part 15.249
Test Procedure:                               ANSI C63.4-2009

This device described above has been tested by Shenzhen Microtest Co.,Ltd. and the test results
show that the equipment under test (EUT) is in compliance with the R&TTE requirements. And it is
applicable only to the tested sample identified in the report.




                Tested      By :

                                                        David Chen                      Oct, 10. 2015

              Reviewed By :

                                                        Leon Chen                       Oct, 10. 2015

             Approved By :

                                                        Ares Liu                        Oct, 10. 2015




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 4 of 17-            Report No.: MTI150911002RF01



                                     SUMMARY OF TEST RESULT

        Item         FCC Part No.                            Description of Test                                 Result

          1          15.203                                  Antenna requirement                                  Pass
                                                             AC power line conducted
          2          15.207                                                                                       N/A*
                                                             emission
          3          15.215                                  20dB bandwidth                                       Pass
                                                             Field strength of fundamental,
                                                             field strength of harmonics,
          4          15.249(a), 15.249(d)                                                                         Pass
                                                             emissions radiated outside of the
                                                             specified frequency bands

* the EUT was power by battery only.




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 5 of 17-            Report No.: MTI150911002RF01


1. General description
1.1 Feature of equipment under test (EUT)

    Product name:                         2.4G Keyboard

    Model name:                           B020 2.4G

    Serial Model:                         B024 2.4G, B027 2.4G, B028 2.4G

    Tx/Rx frequency range:                Tx: 2406MHz~2476MHz

    Modulation Type:                      GFSK

    Power Source:                         3VDC (AAA battery × 2)

    Antenna Designation:                  PCBA antenna (Antenna Gain: 0dBi)

    Hardware Version:                     V1.0

    Software Version:                     V1.0
                                          All the models above are identical in interior structure, electrical
    Remark:                               circuits and components; just model names are different for
                                          marking requirement.




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 6 of 17-            Report No.: MTI150911002RF01


1.2 operation channel list
                          Frequency                                 Frequency                                Frequency
       Channel                                   Channel                                  Channel
                            (MHz)                                     (MHz)                                    (MHz)
            0                2406                    24                2430                   48                2454
            1                 2407                   25                 2431                  49                 2455
            2                 2408                   26                 2432                  50                 2456
            3                 2409                   27                 2433                  51                 2457
            4                 2410                   28                 2434                  52                 2458
            5                 2411                   29                 2435                  53                 2459
            6                 2412                   30                 2436                  54                 2460
            7                 2413                   31                 2437                  55                 2461
            8                 2414                   32                 2438                  56                 2462
            9                 2415                   33                 2439                  57                 2463
           10                 2416                   34                 2440                  58                 2464
           11                 2417                   35                 2441                  59                 2465
           12                 2418                   36                 2442                  60                 2466
           13                 2419                   37                 2443                  61                 2467
           14                 2420                   38                 2444                  62                 2468
           15                 2421                   39                 2445                  63                 2469
           16                 2422                   40                 2446                  64                 2470
           17                 2423                   41                 2447                  65                 2471
           18                 2424                   42                 2448                  66                 2472
           19                 2425                   43                 2449                  67                 2473
           20                 2426                   44                 2450                  68                 2474
           21                 2427                   45                 2451                  69                 2475
           22                 2428                   46                 2452                  70                 2476
           23                 2429                   47                 2453                   /                    /




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 7 of 17-            Report No.: MTI150911002RF01


2. Test Configuration of EUT
2.1 Test Frequency Channel
                               Low                                                       2406MHz
                              Middle                                                     2444MHz
                               High                                                      2476MHz

2.2 EUT operation mode
During testing, EUT is set up to test mode provided by the manufacture to control the Tx operation
followed the test requirement.
2.3 Test conditions
During the measurement the environmental conditions were within the listed ranges:
    - Temperature: 22ºC~27ºC
    - Humidity: 52%~58%
    - Atmospheric pressure: 98kPa~101kPa
2.4 Testing site

     Test Site                         Shenzhen Toby Technology Co., Ltd.
                                       1 A/F., Bldg.6, Yusheng Industrial Zone The National Road
     Test Site Location
                                       No.107 Xixiang Section 467
     FCC Registration
                                       811562
     No.:
     CNAS Registration
                                       CNAS L5813
     No.:
2.5 Ancillary equipment list
            Equipment                         Model                           S/N                     Manufacturer
                  /                              /                              /                              /

2.6 Measurement uncertainty
Measurement Uncertainty for a Level of Confidence of 95 %, U=2xUc(y)

     RF frequency                                                  1 x 10-7
     RF power, conducted                                           ± 1 dB
     Conducted emission of receivers                               ± 1 dB
     Radiated emission of transmitter                              ± 6 dB
     Radiated emission of receiver                                 ± 6 dB
     Temperature                                                   ±1 degree
     Humidity                                                      ±5%




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 8 of 17-            Report No.: MTI150911002RF01


3. List of test equipment
For AC power line conducted emission:

          Equipment                 Manufacturer                 Model             Serial No.          Calibration Due
              LISN                        R&S                  ENV216                101313               2015.12.06
              LISN               SCHWARZBECK                 NNLK 8129              8129245               2015.12.25
         Pulse Limiter           SCHWARZBECK                VTSD 9561F                 9716               2015.12.25
          Test Cable                       N/A                    N/A                  C01                2015.12.06
     EMI Test Receiver                    R&S                    ESCI                101160               2015.12.06

For Radiated emission:

          Equipment               Manufacturer                   Model             Serial No.          Calibration Due
                                 MESS-ELEKTRO
     Log-Bicon Antenna                                       VULB 9160                 3058               2015.12.11
                                      NIK
        Horn Antenna              Schwarzbeck               BBHA 9120D                  631               2015.12.05
        Horn Antenna                Schwarzbeck              BBHA 9170                  373               2015.12.05
          Test Cable             United Microwave                57793                  1m                2015.12.05
          Test Cable             United Microwave A30A30-5006                          10M                2015.12.05
          Microwave
                                         Agilent                 8449B            3008A01714              2015.12.05
         Pre_amplifier
         Pre-Amplifier                  Anritsu                MH648A                M09961               2015.12.05
     EMI Test Receiver                    R&S                   ESCI-7               101318               2015.12.05

For RF conducted emission:

          Equipment                 Manufacturer                 Model             Serial No.          Calibration Due
            Receiver                      R&S                    ESCI                101368               2016.06.01
      Spctrum analyzer                   Agient                 E4470B           MY41441082               2016.06.01

Note: the calibration interval of the above test instruments is 12 months and the calibrations are
traceable to international system unit (SI).




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 9 of 17-            Report No.: MTI150911002RF01


4. Test Result
4.1 Antenna requirement
4.1.1 Requirement defined in FCC 15.203
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
responsible party shall be used with the device. The use of a permanently attached antenna or of an
antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to
comply with the provisions of this section. The manufacturer may design the unit so that a broken
antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector
is prohibited. This requirement does not apply to carrier current devices or to devices operated
under the provisions of §15.211, §15.213, §15.217, §15.219, or §15.221. Further, this requirement
does not apply to intentional radiators that must be professionally installed, such as perimeter
protection systems and some field disturbance sensors, or to other intentional radiators which, in
accordance with §15.31(d), must be measured at the installation site. However, the installer shall be
responsible for ensuring that the proper antenna is employed so that the limits in this part are not
exceeded.
4.1.2 EUT antenna description
The Bluetooth antenna of EUT is an internal permanently attached antenna which the maximum
gain is 0dBi. So the antenna meets the requirement of this part.




                                                                                                    Antenna




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 10 of 17-           Report No.: MTI150911002RF01


4.2 20dB emission bandwidth
4.2.1 Test method
Use the following spectrum analyzer settings:
Span = approximately 2 to 3 times the 20 dB bandwidth, centered on a hopping channel
RBW ≥ 1% of the 20 dB bandwidth
VBW ≥ RBW
Sweep = auto
Detector function = peak
Trace = max hold
The EUT should be transmitting at its maximum data rate. Allow the trace to stabilize. Use the
marker-to-peak function to set the marker to the peak of the emission. Use the marker-delta
function to measure 20 dB down one side of the emission. Reset the marker-delta function, and
move the marker to the other side of the emission, until it is (as close as possible to) even with the
reference marker level. The marker-delta reading at this point is the 20 dB bandwidth of the
emission.
4.2.2 Test Setup




4.2.2 Test result

                      Frequency (MHz)                                     20dB emission bandwidth (MHz)
                               2404                                                          1.46
                               2444                                                          1.47
                               2476                                                          1.47




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 11 of 17-           Report No.: MTI150911002RF01



                                                           2406MHz




                                                           2444MHz




                                                           2476MHz




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 12 of 17-           Report No.: MTI150911002RF01


4.3 Field strength of fundamental, field strength of harmonics, emissions radiated
outside of the specified frequency bands
4.3.1 Limit
the field strength of emissions from intentional radiators operated within these frequency bands
shall comply with the following:
                                                  Field                Field
                Frequency                      strength of          strength of                            Measurement
                                                                                          Detector
                  (MHz)                       fundamental           harmonics                                distance
                                                  mV/m               dBμV/m
               2400-2483.5                         50                   500                  AV                   3m

Emissions radiated outside of the specified frequency bands, except for harmonics, shall be
attenuated by at least 50 dB below the level of the fundamental or to the general radiated emission
limits in §15.209, whichever is the lesser attenuation.
                                                   Field               Field
                Frequency                                                                                  Measurement
                                                 strength            strength             Detector
                  (MHz)                                                                                      distance
                                                  μV/m               dBμV/m
                    30-88                           100                 40                   QP
                   88-216                           150                 43.5                 QP
                  216-960                           200                  46                  QP
                                                                                                                  3m
                 960-1000                           500                  46                  QP
                Above 1000                          500                  54                  AV
                Above 1000                         5000                  74                  PK

4.3.2 Test method
1. The EUT is placed on a turntable, which is 0.8m above ground plane.
2. EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find out the
highest emissions.
3. Use the following spectrum analyzer settings:
Span = wide enough to fully capture the emission being measured, RBW = 1 MHz for f ≥ 1GHz, 100
kHz for f < 1 GHz, VBW ≥ RBW, Sweep = auto, Detector function = peak, Trace = max hold
4. Follow the guidelines in ANSI C63.4-2009 with respect to maximizing the emission by rotating the
EUT, adjusting the measurement antenna height and polarization, etc. The peak reading of the
emission, after being corrected by the antenna factor, cable loss, pre-amp gain, etc., is the peak
field strength, submit this data. Each emission was to be maximized by changing the polarization of
receiving antenna both horizontal and vertical.
5. Set the VBW to 10 Hz, while maintaining all of the other instrument settings. This peak level, once
corrected, must comply with the limit specified in Section 15.209. If the duty cycle per channel of the
hopping signal is less than 100 ms, then the reading obtained with the 10 Hz VBW may be further
adjusted by a “duty cycle correction factor”, derived from 20log(duty cycle/100 ms), in an effort to
demonstrate compliance with the 15.209 limit. Submit this data.



Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 13 of 17-           Report No.: MTI150911002RF01

4.3.3 Test Setup
Blew 1GHz:




Above 1GHz:




4.3.3 Test Result




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 14 of 17-           Report No.: MTI150911002RF01


2406MHz
                        Ant.            Emission
  Frequency                                               Duty factor          Result             Limits        Detect
                    Polarization         level                                                                         Result
                                                                                                                 or
     (MHz)             H/V              dBμV/m                 dB             dBμV/m             dBμV/m
     2406                 H               87.71                 /               87.71               114            PK
     2406                 H               87.71              -24.78             62.93                94            AV
     2406                 V               90.65                 /               90.65               114            PK
     2406                 V               90.65              -24.78             65.87                94            AV
    386.63                H               14.45                 /               14.45                46           QP
                                                                                                                           Pass
    925.75                V               21.73                 /               21.73                46           QP
     4812                 H               57.07                 /               57.07                74            PK
     4812                 H               57.07              -24.78             32.29                54            AV
     4812                 V               57.99                 /               57.99                74            PK
     4812                 V               57.99              -24.78             33.21                54            AV

2444MHz
                        Ant.            Emission
  Frequency                                               Duty factor          Result             Limits        Detect
                    Polarization         level                                                                         Result
                                                                                                                 or
     (MHz)             H/V              dBμV/m                 dB             dBμV/m             dBμV/m
     2444                 H                88.3                 /                88.3               114            PK
     2444                 H                88.3              -24.78             63.52                94            AV
     2444                 V               90.95                 /               90.95               114            PK
     2444                 V               90.95              -24.78             66.17                94            AV
    826.34                H               20.61                 /               20.61                46           QP
                                                                                                                           Pass
    558.73                V               18.77                 /               18.77                46           QP
     4888                 H               58.62                 /               58.62                74            PK
     4888                 H               58.62              -24.78             33.84                54            AV
     4888                 V               59.11                 /               59.11                74            PK
     4888                 V               59.11              -24.78             34.33                54            AV




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 15 of 17-           Report No.: MTI150911002RF01

2476MHz
                        Ant.            Emission
  Frequency                                               Duty factor          Result             Limits        Detect
                    Polarization         level                                                                         Result
                                                                                                                 or
     (MHz)             H/V              dBμV/m                 dB             dBμV/m             dBμV/m
     2476                 H               88.16                 /               88.16               114            PK
     2476                 H               88.16              -24.78             63.38                94            AV
     2476                 V               91.41                 /               91.41               114            PK
     2476                 V               91.41              -24.78             66.63                94            AV
    268.67                H               22.38                 /               22.38                46           QP
                                                                                                                           Pass
    487.93                V               25.61                 /               25.61                46           QP
     4952                 H               59.45                 /               59.45                74            PK
     4952                 H               59.45              -24.78             34.67                54            AV
     4952                 V               59.73                 /               59.73                74            PK
     4952                 V               59.73              -24.78             34.95                54            AV

Note:
AV Emission Level= PK Emission Level + Duty factor
Duty Factor = 20*log10 (Duty cycle) = 20*log10 ((0.22*3)/11.44) = -24.78 (Please see the
following plots for the detail of duty cycle).
other frequency noises omitted in this report were not seen or had enough margin (more
than 20dB).
If the PK measured values lower than average mode limit, the EUT shall be deemed to meet
average limits and then no additional average mode measurement performed.




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 16 of 17-           Report No.: MTI150911002RF01


Duty Cycle:

                                                             Plot 1




                                                             Plot 2




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 17 of 17-           Report No.: MTI150911002RF01



                                                             Plot 3




                                                             Plot 4




                                               ----END OF REPORT----




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.



Document Created: 2015-10-12 16:06:49
Document Modified: 2015-10-12 16:06:49

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC