FCC 15 BT report

FCC ID: 2AFW2B021

Test Report

Download: PDF
FCCID_2776113

                                    Test Report

                                    FCC ID: 2AFW2B021


                                    Date of issue: Sep. 02, 2015



     Sample Description:                             Bluetooth Keyboard


     Model(s):                                       B021/ B202 /B204 /B205 /B206


     Applicant:                                      Shenzhen DZH Industrial Co., Ltd.


     Address:                                        3th Floor, YiTuo Mike Industrial A building, Bu Yong
                                                     Industrial D zone, ShaJing, Shenzhen


     Date of Test:                                   Aug, 20. 2015 to Sep. 01, 2015




                                        Shenzhen Microtest Co., Ltd.
                                          http://www.mtitest.com




This test report is limited to the above client company and the product mode only. It may not be duplicated without prior written consent of
Shenzhen Microtest Co., Ltd.

Tel:(86-755)88850135          Fax: (86-755) 88850136               http://www.mtitest.com                     E-mail: mti@51mti.com
Add: 1F & 3F, East Block,   Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District,        Shenzhen, Guangdong, P. R. China.


                                                                   - Page 2 of 24-             Report No.: MTI150820001RF01


                                              TABALE OF CONTENTS
1. General description ............................................................................................................... 5
1.1 Feature of equipment under test (EUT)............................................................................... 5
1.2 operation channel list ........................................................................................................... 5
2. Test Configuration of EUT .................................................................................................... 6
2.1 Test Frequency Channel ...................................................................................................... 6
2.2 EUT operation mode ............................................................................................................. 6
2.4 Test conditions...................................................................................................................... 6
2.5 Testing site ............................................................................................................................ 6
2.6 Ancillary equipment list........................................................................................................ 6
2.6 Measurement uncertainty .................................................................................................... 6
3. List of test equipment ........................................................................................................... 7
4. Test Result ............................................................................................................................. 8
4.1 Antenna requirement ............................................................................................................ 8
4.2 AC power line conducted emission .................................................................................... 9
4.3 Peak output power .............................................................................................................. 12
4.3 20dB emission bandwidth .................................................................................................. 14
4.4 Carrier frequency separation ............................................................................................. 16
4.5 Number of hopping channel .............................................................................................. 18
4.6 Time of occupancy (dwell time) ......................................................................................... 19
4.6 Band edge spurious emission, conducted spurious emission ...................................... 20
4.7 Radiated emission .............................................................................................................. 23




This test report is limited to the above client company and the product mode only. It may not be duplicated without prior written consent of
Shenzhen Microtest Co., Ltd.

Tel:(86-755)88850135          Fax: (86-755) 88850136               http://www.mtitest.com                     E-mail: mti@51mti.com
Add: 1F & 3F, East Block,   Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District,        Shenzhen, Guangdong, P. R. China.


                                                              - Page 3 of 24-            Report No.: MTI150820001RF01


TEST RESULT CERTIFICATION


Applicant’s name:                             Shenzhen DZH Industrial Co., Ltd.
                                              3th Floor, YiTuo Mike Industrial A building, Bu Yong Industrial D
Address:
                                              zone, ShaJing, Shenzhen
Manufacture's Name:                           Shenzhen DZH Industrial Co., Ltd.
                                              3th Floor, YiTuo Mike Industrial A building, Bu Yong Industrial D
Address:
                                              zone, ShaJing, Shenzhen
Product description
Product name:                                 Bluetooth Keyboard
Trademark:                                    千业
Model name:                                   B021
Serial Model:                                 B202/B204/205/B026
Standards:                                    FCC Part 15.247
                                              ANSI C63.4-2009;
Test Procedure:
                                              FCC public notice DA 00-705

This device described above has been tested by Shenzhen Microtest Co.,Ltd. and the test results
show that the equipment under test (EUT) is in compliance with the R&TTE requirements. And it is
applicable only to the tested sample identified in the report.




                Tested      By :

                                                        David Chen                      Sep, 02. 2015

              Reviewed By :

                                                        Leon Chen                       Sep, 02. 2015

             Approved By :

                                                        Ares Liu                        Sep, 02. 2015




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 4 of 24-            Report No.: MTI150820001RF01



                                     SUMMARY OF TEST RESULT

        Item         FCC Part No.                            Description of Test                                 Result

          1          15.203                                  Antenna requirement                                  Pass
                                                             AC power line conducted
          2          15.207                                                                                       Pass
                                                             emission
          3          15.247(b)(1)                            Peak output power                                    Pass

          4          15.247(a)(1)                            20dB emission bandwidth                              Pass

          5          15.247(a)(1)                            Carrier frequency separation                         Pass

          6          15.247(a)1                              Number of hopping channel                            Pass

          7          15.247(a)(1)                            Time of occupancy (dwell time)                       Pass
                                                             Band edge spurious emission,
          8          15.247(d)                                                                                    Pass
                                                             conducted spurious emission
          9          15.247(d), 15.209                       Radiated emission                                    Pass




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 5 of 24-            Report No.: MTI150820001RF01


1. General description
1.1 Feature of equipment under test (EUT)

    Product name:                         Bluetooth Keyboard

    Model name:                           B021

    Serial Model:                         B202/B204/B205/B206

    Tx/Rx frequency range:                Tx/Rx: 2402MHz~2480MHz

    Bluetooth version:                    3.0

    Modulation Type:                      GFSK

    Power Source:                         Li-on battery DC Voltage 3.7V

    Antenna Designation:                  PCB antenna (Antenna Gain: 0dBi)

    Hardware Version:                     V1.0

    Software Version:                     V1.0
                                          All the models above are identical in interior structure, electrical
    Remark:                               circuits and components; just model names are different for
                                          marking requirement.

1.2 operation channel list
       Channel            Frequency              Channel            Frequency             Channel            Frequency
            0              2402MHz                   20             2422MHz                   40              2442MHz
            1              2403MHz                   21             2423MHz                   41              2443MHz
           ---                  ---                  ---                 ---                  ---                  ---
           ---                  ---                  ---                 ---                  ---                  ---
           18              2420MHz                   38             2440MHz                   77              2479MHz
           19              2421MHz                   39             2441MHz                   78              2480MHz




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 6 of 24-            Report No.: MTI150820001RF01


2. Test Configuration of EUT
2.1 Test Frequency Channel
                               Low                                                       2402MHz
                              Middle                                                     2441MHz
                               High                                                      2480MHz

2.2 EUT operation mode
During testing, RF test program provided by the the manufacture to control the Tx/Rx operation
followed the test requirement.
2.4 Test conditions
During the measurement the environmental conditions were within the listed ranges:
    - Temperature: 22ºC~27ºC
    - Humidity: 52%~58%
    - Atmospheric pressure: 98kPa~101kPa
2.5 Testing site

     Test Site                         Shenzhen Toby Technology Co., Ltd.
                                       1 A/F., Bldg.6, Yusheng Industrial Zone The National Road
     Test Site Location
                                       No.107 Xixiang Section 467
     FCC Registration
                                       811562
     No.:
     CNAS Registration
                                       CNAS L5813
     No.:
2.6 Ancillary equipment list
            Equipment                         Model                           S/N                     Manufacturer
            Notebook                           G40                      YB10482397                       LENOVE

2.6 Measurement uncertainty
Measurement Uncertainty for a Level of Confidence of 95 %, U=2xUc(y)

     RF frequency                                                  1 x 10-7
     RF power, conducted                                           ± 1 dB
     Conducted emission of receivers                               ± 1 dB
     Radiated emission of transmitter                              ± 6 dB
     Radiated emission of receiver                                 ± 6 dB
     Temperature                                                   ±1 degree
     Humidity                                                      ±5%




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 7 of 24-            Report No.: MTI150820001RF01


3. List of test equipment
For AC power line conducted emission:

          Equipment                 Manufacturer                 Model             Serial No.          Calibration Due
              LISN                        R&S                  ENV216                101313               2015.12.06
              LISN               SCHWARZBECK                 NNLK 8129              8129245               2015.12.25
         Pulse Limiter           SCHWARZBECK                VTSD 9561F                 9716               2015.12.25
          Test Cable                       N/A                    N/A                  C01                2015.12.06
     EMI Test Receiver                    R&S                    ESCI                101160               2015.12.06

For Radiated emission:

          Equipment               Manufacturer                   Model             Serial No.          Calibration Due
                                 MESS-ELEKTRO
     Log-Bicon Antenna                                       VULB 9160                 3058               2015.12.11
                                      NIK
        Horn Antenna              Schwarzbeck               BBHA 9120D                  631               2015.12.05
        Horn Antenna                Schwarzbeck              BBHA 9170                  373               2015.12.05
          Test Cable             United Microwave                57793                  1m                2015.12.05
          Test Cable             United Microwave A30A30-5006                          10M                2015.12.05
          Microwave
                                         Agilent                 8449B            3008A01714              2015.12.05
         Pre_amplifier
         Pre-Amplifier                  Anritsu                MH648A                M09961               2015.12.05
     EMI Test Receiver                    R&S                   ESCI-7               101318               2015.12.05

For RF conducted emission:

          Equipment                 Manufacturer                 Model             Serial No.          Calibration Due
            Receiver                      R&S                    ESCI                101368               2016.06.01
      Spctrum analyzer                   Agient                 E4470B           MY41441082               2016.06.01

Note: the calibration interval of the above test instruments is 12 months and the calibrations are
traceable to international system unit (SI).




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 8 of 24-            Report No.: MTI150820001RF01


4. Test Result
4.1 Antenna requirement
4.1.1 Requirement defined in FCC 15.203
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
responsible party shall be used with the device. The use of a permanently attached antenna or of an
antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to
comply with the provisions of this section. The manufacturer may design the unit so that a broken
antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector
is prohibited. This requirement does not apply to carrier current devices or to devices operated
under the provisions of §15.211, §15.213, §15.217, §15.219, or §15.221. Further, this requirement
does not apply to intentional radiators that must be professionally installed, such as perimeter
protection systems and some field disturbance sensors, or to other intentional radiators which, in
accordance with §15.31(d), must be measured at the installation site. However, the installer shall be
responsible for ensuring that the proper antenna is employed so that the limits in this part are not
exceeded.
4.1.2 EUT antenna description
The Bluetooth antenna of EUT is an internal permanently attached antenna which the
maximum gain is 0dBi. So the antenna meets the requirement of this part.




                   Antenna




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 9 of 24-            Report No.: MTI150820001RF01


4.2 AC power line conducted emission
4.2.1 Limits

         Frequency                        Quasi-peak Limit                                   Average Limit
           (MHz)                               dBμV                                             dBμV
          0.15 - 0.5                            66 - 56 *                                        56 - 46 *
            0.5 - 5                                 56                                               46
            5 - 30                                  60                                               50

* Decreases linearly with the logarithm of the frequency in the range.
4.2.2 Test method
1. The EUT was placed on a table, which is 0.8m above ground plane
2. The power line of the EUT is connected to the AC mains through a Artificial Mains Network
(A.M.N.).
3. Maximum procedure was performed to ensure EUT compliance
4. A EMI test receiver is used to test the emissions from both sides of AC line
4.2.3 Test result




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 10 of 24-           Report No.: MTI150820001RF01



    Temperature: 24℃                                  Relative Humidity: 55%
    Pressure:          101kPa                         Phase:                   L
                                                                               Charging+ transmitting(measured
    Test voltage: AC 120V/60Hz                        Test mode:
                                                                               at notebook charger AC port)




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 11 of 24-           Report No.: MTI150820001RF01



    Temperature: 24℃                                  Relative Humidity: 55%
    Pressure:          101kPa                         Phase:                   N
                                                                               Charging+ transmitting(measured
    Test voltage: AC 120V/60Hz                        Test mode:
                                                                               at notebook charger AC port)




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 12 of 24-           Report No.: MTI150820001RF01


4.3 Peak output power
4.2.1 Limits
Conducted peak output power limit is 125mW (21dBm)
4.2.2 Test Method
Use the following spectrum analyzer settings:
Span = approximately 5 times the 20 dB bandwidth, centered on a hopping channel
RBW > the 20 dB bandwidth of the emission being measured
VBW ≥ RBW
Sweep = auto
Detector function = peak
Trace = max hold
Allow the trace to stabilize. Use the marker-to-peak function to set the marker to the peak of the
emission.
4.2.3 Test Result


            Frequency (MHz)                     Peak output power (dBm)                            Limit (dBm)
                     2402                                     2.54                                       21
                     2441                                     2.22                                       21
                     2480                                     1.78                                       21

Test plots as below




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 13 of 24-           Report No.: MTI150820001RF01



                                                           2402MHz




                                                           2441MHz




                                                           2480MHz




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 14 of 24-           Report No.: MTI150820001RF01


4.3 20dB emission bandwidth
4.3.1 Test method
Use the following spectrum analyzer settings:
Span = approximately 2 to 3 times the 20 dB bandwidth, centered on a hopping channel
RBW ≥ 1% of the 20 dB bandwidth
VBW ≥ RBW
Sweep = auto
Detector function = peak
Trace = max hold
The EUT should be transmitting at its maximum data rate. Allow the trace to stabilize. Use the
marker-to-peak function to set the marker to the peak of the emission. Use the marker-delta
function to measure 20 dB down one side of the emission. Reset the markerdelta function, and
move the marker to the other side of the emission, until it is (as close as possible to) even with the
reference marker level. The marker-delta reading at this point is the 20 dB bandwidth of the
emission.
4.3.2 Test result

                      Frequency (MHz)                                     20dB emission bandwidth (MHz)
                               2402                                                         0.816
                               2441                                                         0.816
                               2480                                                         0.812




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 15 of 24-           Report No.: MTI150820001RF01



                                                           2402MHz




                                                           2441MHz




                                                           2480MHz




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 16 of 24-           Report No.: MTI150820001RF01


4.4 Carrier frequency separation
4.4.1 Limits
Frequency hopping systems operating in the 2400-2483.5 MHz band may have hopping channel
carrier frequencies that are separated by 25 kHz or two-thirds of the 20 dB bandwidth of the
hopping channel, whichever is greater.
4.4.2 Test method
The EUT must have its hopping function enabled. Use the following spectrum analyzer settings:
Span = wide enough to capture the peaks of two adjacent channels
Resolution (or IF) Bandwidth (RBW) ≥ 1% of the span
Video (or Average) Bandwidth (VBW) ≥ RBW
Sweep = auto
Detector function = peak
Trace = max hold
Allow the trace to stabilize. Use the marker-delta function to determine the separation between the
peaks of the adjacent channels.
4.4.3 Test result

            Frequency (MHz)                           Separation (MHz)                             Limit (MHz)
                     2402                                        1                                     0.544
                     2441                                        1                                     0.544
                     2480                                        1                                     0.544




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 17 of 24-           Report No.: MTI150820001RF01



                                                           2402MHz




                                                           2441MHz




                                                           2480MHz




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 18 of 24-           Report No.: MTI150820001RF01


4.5 Number of hopping channel
4.5.1 Limits
Frequency hopping systems in the 2400-2483.5 MHz band shall use at least 15 channels.
4.5.2 Test method
The EUT must have its hopping function enabled. Use the following spectrum analyzer settings:
Span = the frequency band of operation
RBW ≥ 1% of the span
VBW ≥ RBW
Sweep = auto
Detector function = peak
Trace = max hold
Allow the trace to stabilize. It
4.5.3 Test Result

               Number of hopping channels                                                     79




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 19 of 24-           Report No.: MTI150820001RF01


4.6 Time of occupancy (dwell time)
4.6.1 Limit
The average time of occupancy on any channel shall not be greater than 0.4 seconds within a
period of 0.4 seconds multiplied by the number of hopping channels employed.
4.6.3 Test method
The EUT must have its hopping function enabled. Use the following spectrum analyzer settings:
Span = zero span, centered on a hopping channel
RBW = 1 MHz
VBW ≥ RBW
Sweep = as necessary to capture the entire dwell time per hopping channel
Detector function = peak
Trace = max hold
Use the marker-delta function to determine the dwell time.
4.6.4 Test Result

           Packet type              Pulse Duration (ms)                Dwell time (s)                     Limit (s)
                DH5                            2.84                          0.303                           0.4




Note: for the worst mode of DH5 packet type, in normal hopping mode, hopping rate is 1600hops/s
with 6 slots in 79 hopping channel




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 20 of 24-           Report No.: MTI150820001RF01


4.6 Band edge spurious emission, conducted spurious emission
4.6.1 Limit
In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally
modulated intentional radiator is operating, the radio frequency power that is produced by the
intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that
contains the highest level of the desired power, based on either an RF conducted or a radiated
measurement, provided the transmitter demonstrates compliance with the peak conducted power
limits.
4.6.2 Test method
Use the following spectrum analyzer settings:
Set RBW=100 kHz. VBW≥3RBW. Detector =peak, Sweep time = auto couple, Trace mode = max
hold.
4.6.3 Test Result




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 21 of 24-           Report No.: MTI150820001RF01

RF Conducted emission
                                                           2402MHz




                                                           2441MHz




                                                           2480MHz




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 22 of 24-           Report No.: MTI150820001RF01

Band edge
                     2402MHz – no hop                                                2402MHz – hop




                        2480 – no hop                                                   2480 – hop




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 23 of 24-           Report No.: MTI150820001RF01


4.7 Radiated emission
4.7.1 Limit
In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally
modulated intentional radiator is operating, the radio frequency power that is produced by the
intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that
contains the highest level of the desired power, based on either an RF conducted or a radiated
measurement, provided the transmitter demonstrates compliance with the peak conducted power
limits. Attenuation below the general limits specified in §15.209(a) is not required. In addition,
radiated emissions which fall in the restricted bands, as defined in §15.205(a), must also comply
with the radiated emission limits specified in §15.209(a).
                                                   Field               Field
                Frequency                                                                                  Measurement
                                                 strength            strength             Detector
                  (MHz)                                                                                      distance
                                                  μV/m               dBμV/m
                    30-88                           100                 40                   QP
                   88-216                           150                 43.5                 QP
                  216-960                           200                  46                  QP
                                                                                                                  3m
                 960-1000                           500                  46                  QP
                Above 1000                          500                  54                  AV
                Above 1000                         5000                  74                  PK

4.7.2 Test method
1. The EUT is placed on a turntable, which is 0.8m above ground plane.
2. EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find out the
highest emissions.
3. Use the following spectrum analyzer settings:
Span = wide enough to fully capture the emission being measured, RBW = 1 MHz for f ≥ 1GHz, 100
kHz for f < 1 GHz, VBW ≥ RBW, Sweep = auto, Detector function = peak, Trace = max hold
4. Follow the guidelines in ANSI C63.4-2009 with respect to maximizing the emission by rotating the
EUT, adjusting the measurement antenna height and polarization, etc. The peak reading of the
emission, after being corrected by the antenna factor, cable loss, pre-amp gain, etc., is the peak
field strength, submit this data. Each emission was to be maximized by changing the polarization of
receiving antenna both horizontal and vertical.
5. Set the VBW to 10 Hz, while maintaining all of the other instrument settings. This peak level, once
corrected, must comply with the limit specified in Section 15.209. If the duty cycle per channel of the
hopping signal is less than 100 ms, then the reading obtained with the 10 Hz VBW may be further
adjusted by a “duty cycle correction factor”, derived from 20log(duty cycle/100 ms), in an effort to
demonstrate compliance with the 15.209 limit. Submit this data.
4.7.3 Test Result




Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.


                                                              - Page 24 of 24-           Report No.: MTI150820001RF01


2402MHz
                                    Ant.
        Frequency                                      Emission level                 Limits
                                Polarization                                                           Detector Result
           (MHz)                   H/V                      dBμV/m                  dBμV/m
           191.75                      V                     22.36                     43.5               QP
           205.67                      H                     21.81                     43.5               QP
            2400                       V                     45.38                      74                PK
                                                                                                                     Pass
            2400                       H                     45.27                      74                PK
            4804                       V                     52.81                      74                PK
            4804                       H                     50.47                      74                PK

2441MHz
                                    Ant.
        Frequency                                      Emission level                 Limits
                                Polarization                                                           Detector Result
           (MHz)                   H/V                      dBμV/m                  dBμV/m
           191.75                      V                     22.08                     43.5               QP
           205.67                      H                     21.54                     43.5               QP
                                                                                                                     Pass
            4882                       V                     51.75                      74                PK
            4882                       H                     50.19                      74                PK

2480MHz
                                    Ant.
        Frequency                                      Emission level                 Limits
                                Polarization                                                           Detector Result
           (MHz)                   H/V                      dBμV/m                  dBμV/m
           191.75                      V                     22.84                     43.5               QP
           205.67                      H                     21.39                     43.5               QP
           2483.5                      V                     46.37                      74                PK
                                                                                                                     Pass
           2483.5                      H                     46.22                      74                PK
            4960                       V                     49.27                      74                PK
            4960                       H                      46.9                      74                PK

Note:
QP Emission Level= Antenna Factor +Cable Loss + Reading
PK Emission Level= Antenna Factor +Cable Loss - Amp. Factor + Reading
AV Emission Level= PK Emission Level+20log (duty cycle) or set the RBW/VBW to be 1MHz/10Hz
to read the level.
If the PK measured values lower than average mode limit, the EUT shall be deemed to meet
average limits and then no additional average mode measurement performed.


                                               ----END OF REPORT----

Tel:(86-755)88850135          Fax: (86-755) 88850136                 http://www.mtitest.com               E-mail: mti@51mti.com
Address: 1F & 3F, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, P. R. China.



Document Created: 2015-09-17 15:04:03
Document Modified: 2015-09-17 15:04:03

© 2025 FCC.report