MPE

FCC ID: 2AFSGQ1

RF Exposure Info

Download: PDF
FCCID_3941278

S
                                     MPE TEST REPORT
T                                      Report No:STS1807162W03


S                                                      Issued for

                     Dongguan Jin wen hua digital technology Co., LTD.

                NO.1 Hua Da Road, Long Bei Ling Village, Tangxia Town,
                         Dongguan City, Guangdong, China




L                           Product Name: Wireless charger

                               Brand Name: N/A




A
                               Model Name: Q1


                              Series Model: N/A


                                      FCC ID: 2AFSGQ1



B                           Test Standard: FCC CFR 47 part 1, 1.1310




    Any reproduction of this document must be done in full. No single part of this document may be reproduced without
    permission from STS, All Test Data Presented in this report is only applicable to presented Test sample.

    Shenzhen STS Test Services Co., Ltd.
    1/F., Building B, Zhuoke Science Park, No.190, Chongqing Road,
    Fuyong Street, Bao’an District, Shenzhen, Guangdong, China
    TEL: +86-755 3688 6288 FAX: +86-755 3688 6277 E-mail:sts@stsapp.com


                                                         Page 2 of 13               Report No.: STS1807162W03



                                               TEST RESULT CERTIFICATION

Applicant’s name .................... :         Dongguan Jin wen hua digital technology Co., LTD.
                                                NO.1 Hua Da Road, Long Bei Ling Village, Tangxia Town,
Address .................................. :
                                                Dongguan City, Guangdong, China
Manufacture's Name .............. :             Dongguan Jin wen hua digital technology Co., LTD.

                                                NO.1 Hua Da Road, Long Bei Ling Village, Tangxia Town,
Address .................................. :
                                                Dongguan City, Guangdong, China
Product description
Product Name ........................ :         Wireless charger
Brand Name ......................... :          N/A
Model Name ........................... :        Q1

Series Model .......................... :       N/A
Standards      :                    FCC CFR 47 part 1, 1.1310
Test Procedure :                    680106 D01 RF Exposure Wireless Charging Apps v03
This device described above has been tested by STS, the test results show that the equipment
under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested
sample identified in the report.
This report shall not be reproduced except in full, without the written approval of STS, this document
may be altered or revised by STS, personal only, and shall be noted in the revision of the document.
Date of performance of tests:       13 July 2018 ~ 18 July 2018
Date of Issue :                                 20 July 2018

Test Result          :                          Pass



                         Testing Engineer            :

                                                                   ( Chris chen )



                         Technical Manager           :

                                                                   ( Sean she )


                         Authorized Signatory :

                                                                      (Vita Li)


                                Page 3 of 13   Report No.: STS1807162W03



                       Table of Contents                        Page



1. SUMMARY OF TEST RESULTS                                        5
  1.1 TEST FACTORY                                                5
  1.2 MEASUREMENT UNCERTAINTY                                     5
  1.3 GENERAL DESCRIPTION OF EUT                                  6
  1.4 EQUIPMENTS LIST FOR ALL TEST ITEMS                          7

2. MAXIMUM PERMISSIBLE EXPOSURE                                   8
  2.1 MAXIMUM PERMISSIBLE EXPOSURE                                8
  2.2 TEST PROCEDURE                                              9
  2.3 TEST SETUP                                                  9
  2.5 MAXIMUM PERMISSIBLE EXPOSURE                               10


                               Page 4 of 13            Report No.: STS1807162W03


                            Revision History


Rev.   Issue Date       Report NO.       Effect Page            Contents

00     20 July 2018   STS1807162W03            ALL             Initial Issue


                                            Page 5 of 13           Report No.: STS1807162W03


1. SUMMARY OF TEST RESULTS
Test procedures according to the technical standards:
FCC KDB 680106 D01 RF Exposure Wireless Charging Apps v03

                                           FCC CFR 47

        Standard
                                          Test Item                Judgment        Remark
         Section

                              Electric Field Strength (E) (V/m)      PASS
   FCC CFR 47 part1,
   1.1310 KDB680106
         D01v03               Magnetic Field Strength (H) (A/m)      PASS


1.1 TEST FACTORY
   Shenzhen STS Test Services Co., Ltd.
   Add. : 1/F., Building B, Zhuoke Science Park, No.190, Chongqing Road,
   Fuyong Street, Bao’an District, Shenzhen, Guangdong, China
  CNAS Registration No.: L7649; FCC Registration No.: 625569
  IC Registration No.: 12108A; A2LA Certificate No.: 4338.01;

1.2 MEASUREMENT UNCERTAINTY
  The reported uncertainty of measurement y ±U,where expended uncertainty U is based on a
  standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of
  approximately 95 %。

            No.    Item                                                 Uncertainty

             1     All emissions,radiated(<30M)(9KHz-30MHz)             ±2.45dB

             2     Temperature                                          ±0.5°C

             3     Humidity                                             ±2%


                                           Page 6 of 13             Report No.: STS1807162W03


1.3 GENERAL DESCRIPTION OF EUT

           Product Name                    Wireless charger
           Trade Name                      N/A
           Model Name                      Q1
           Series Model                    N/A
           Model Difference                N/A
           Equipemnt Category              Non-ISM frequency
           Operating frequency             127.5KHz

           Modulation Type                 ASK
                                           Input:12V-1.5A/5V-2A
           Ratings
                                           Output:9V-1A/5V-1A
           Hardware version number         V1.1
           Software version number         V1.0


Note:
    1. For a more detailed features description, please refer to the manufacturer’s specifications
       or the User’s Manual.
    2. Table for Filed Antenna
          Ant        Brand      Model Name Antenna Type Connector                   NOTE


          1          N/A             Q1             Coil            N/A            Antenna



       The EUT antenna is Coil Antenna. No antenna other than that furnished by the responsible
       party shall be used with the device.


                                       Page 7 of 13           Report No.: STS1807162W03


1.4 EQUIPMENTS LIST FOR ALL TEST ITEMS


                                                                   Last
Kind of Equipment   Manufacturer   Type No.      Serial No.                   Calibrated until
                                                                calibration
   EMF Meter          NARDA        ELT-400        N-0342        2017.10.23      2018.10.22


                                               Page 8 of 13              Report No.: STS1807162W03


2. MAXIMUM PERMISSIBLE EXPOSURE
2.1 MAXIMUM PERMISSIBLE EXPOSURE
Limit of Maximum Permissible Exposure

                            Limits for Occupational / Controlled Exposure

   Frequency Range        Electric Field       Magnetic Field                         Averaging Time
                                                                  Power Density (S)
          (MHz)         Strength (E) (V/m)   Strength (H) (A/m)                        |E|²,|H|²or S
                                                                     (mW/ cm²)
                                                                                         (minutes)
  0.3-3.0                      614                 1.63                (100)*                6
  3.0-30                     1842 / f             4.89 / f            (900 / f)*             6
  30-300                      61.4                 0.163                 1.0                 6
  300-1500                                                             F/300                 6
  1500-100,000                                                            5                  6


                        Limits for General Population / Uncontrolled Exposure

   Frequency Range        Electric Field       Magnetic Field                         Averaging Time
                                                                  Power Density (S)
          (MHz)         Strength (E) (V/m)   Strength (H) (A/m)                        |E|²,|H|²or S
                                                                     (mW/ cm²)
                                                                                         (minutes)
  0.3-1.34                     614                 1.63                (100)*                30
  1.34-30                     824/f                2.19/f             (180 / f)*             30
  30-300                      27.5                 0.073                 0.2                 30
  300-1500                                                             F/1500                30
  1500-100,000                                                            1                  30


Note 1: f = frequency in MHz ; *Plane-wave equivalent power density
Note 2: For the applicable limit, see FCC 1.1310, 680106 D01 RF Exposure Wireless Charging Apps v03
Note 3: Emissions between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1
of Section 1.1310: 614 V/m and 1.63 A/m. A KDB inquiry is required to determine the applicable exposure
limits below 100 kHz.
Note 4: The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top
surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE
limit .


                                           Page 9 of 13            Report No.: STS1807162W03


2.2 TEST PROCEDURE
 a. For devices designed for typical desktop applications, such a wireless charging pads, RF
    exposure evaluation should be conducted assuming a user separation distance of 20
    cm(Top) and 15cm(Edge). E and H field strength measurements or numerical modeling
    may be used to demonstrate compliance. Measurements should be made from all sides
    and the top of the primary/client pair, with the 20 cm(Top) and 15cm(Edge) measured from
    the center of the probe(s) to the edge of the device.

2.3 TEST SETUP




2.4 Test results
The EUT does comply with item 5 KDB680106 D01 v03.
(1) Power transfer frequency is less than 1 MHz.
    (Conform)
(2) Output power from each primary coil is less than or equal to 15 watts.
    (Conform)
(3) The transfer system includes only single primary and secondary coils. This includes charging
    systems that may have multiple primary coils and clients that are able to detect and allow
    coupling only between individual pairs of coils.
    (Conform)
(4) Client device is placed directly in contact with the transmitter.
    (Conform)
(5) Mobile exposure conditions only (portable exposure conditions are not covered by this
    exclusion).
    (Conform)
(6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top
    surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the
    MPE limit.
    (Conform)


                                             Page 10 of 13            Report No.: STS1807162W03


     2.5 MAXIMUM PERMISSIBLE EXPOSURE

                                            E-Filed Strength
             Probe        Test                                           50%
                                       Calculated       Calculated                   Limits
Charging   from EUT     Distance                                        Limits                   Result
                                       Value (A/m)     Value (V/m)                Test (V/m)
             Side         (cm)                                        Test(V/m)
 < 1%
             Front         15             0.117            0.440                                 PASS
Battery
 < 1%
             Rear          15             0.110            0.432                                 PASS
Battery
 < 1%
              Left         15             0.109            0.439         307          614        PASS
Battery
 < 1%
             Right         15             0.120            0.443                                 PASS
Battery
 < 1%
              Top          20             0.121            0.453                                 PASS
Battery
                                            H-Filed Strength
                          Test                                           50%
             Test                      Measured         Calculated                   Limits
Charging                Distance                                        Limits                   Result
            Position                   Value(uT)       Value (A/m)                Test (A/m)
                          (cm)                                        Test(A/m)
 < 1%
               A           15             0.146            0.117                                 PASS
Battery
 < 1%
               B           15             0.138            0.110                                 PASS
Battery
 < 1%
               C           15             0.136            0.109        0.815        1.63        PASS
Battery
 < 1%
               D           15             0.150            0.120                                 PASS
Battery
 < 1%
               E           20             0.151            0.121                                 PASS
Battery

   Note: The aggregate H-filed strengths at 15cm surrounding the device and 20cm above the top
   surface.
   A/m=uT/1.25


                                             Page 11 of 13            Report No.: STS1807162W03



                                            E-Filed Strength
             Probe        Test                                           50%
                                       Calculated       Calculated                   Limits
Charging   from EUT     Distance                                        Limits                   Result
                                       Value (A/m)     Value (V/m)                Test (V/m)
             Side         (cm)                                        Test(V/m)
  50%
             Front         15             0.105            0.445                                 PASS
Battery
  50%
             Rear          15             0.107            0.429                                 PASS
Battery
  50%
              Left         15             0.119            0.433         307          614        PASS
Battery
  50%
             Right         15             0.115            0.437                                 PASS
Battery
  50%
              Top          20             0.124            0.451                                 PASS
Battery
                                            H-Filed Strength
                          Test                                           50%
             Test                      Measured         Calculated                   Limits
Charging                Distance                                        Limits                   Result
            Position                   Value(uT)       Value (A/m)                Test (A/m)
                          (cm)                                        Test(A/m)
  50%
               A           15             0.131            0.105                                 PASS
Battery
  50%
               B           15             0.134            0.107                                 PASS
Battery
  50%
               C           15             0.149            0.119        0.815        1.63        PASS
Battery
  50%
               D           15             0.144            0.115                                 PASS
Battery
  50%
               E           20             0.155            0.124                                 PASS
Battery

   Note: The aggregate H-filed strengths at 15cm surrounding the device and 20cm above the top
   surface.
   A/m=uT/1.25


                                             Page 12 of 13            Report No.: STS1807162W03




                                            E-Filed Strength
             Probe        Test                                           50%
                                       Calculated       Calculated                   Limits
Charging   from EUT     Distance                                        Limits                   Result
                                       Value (A/m)     Value (V/m)                Test (V/m)
             Side         (cm)                                        Test(V/m)
 >99%
             Front         15             0.112            0.443                                 PASS
Battery
 >99%
             Rear          15             0.119            0.448                                 PASS
Battery
 >99%
              Left         15             0.105            0.435         307          614        PASS
Battery
 >99%
             Right         15             0.121            0.439                                 PASS
Battery
 >99%
              Top          20             0.126            0.455                                 PASS
Battery
                                            H-Filed Strength
                          Test                                           50%
             Test                      Measured         Calculated                   Limits
Charging                Distance                                        Limits                   Result
            Position                   Value(uT)       Value (A/m)                Test (A/m)
                          (cm)                                        Test(A/m)
 >99%
               A           15             0.140            0.112                                 PASS
Battery
 >99%
               B           15             0.149            0.119                                 PASS
Battery
 >99%
               C           15             0.131            0.105        0.815        1.63        PASS
Battery
 >99%
               D           15             0.151            0.121                                 PASS
Battery
 >99%
               E           20             0.158            0.126                                 PASS
Battery

   Note: The aggregate H-filed strengths at 15cm surrounding the device and 20cm above the top
   surface.
   A/m=uT/1.25


         Page 13 of 13   Report No.: STS1807162W03


     MPE SETUP PHOTO




※※※※※END OF THE REPORT※※※※※



Document Created: 2018-07-20 03:37:22
Document Modified: 2018-07-20 03:37:22

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC