RF Exposure

FCC ID: 2AFP2FC40

RF Exposure Info

Download: PDF
FCCID_4393986

                                                                  Shenzhen CTL Testing Technology Co., Ltd.
                                                                     Tel: +86-755-89486194   Fax: +86-755-26636041

                                                   RF EXPOSURE REPORT

Report Reference No. .............. :              CTL1907031011-MPE
                Compiled by
                                                              Happy Guo
( position+printed name signature)                       (File administrators)
               Supervised by
                                                              Nice Nong
( position+printed name+signature)                          (Test Engineer)
            Approved by                                        Ivan Xie
( position+printed name+signature)                            (Manager)


Testing Laboratory Name ........ :                 Shenzhen CTL Testing Technology Co., Ltd.
                                                   Floor 1-A, Baisha Technology Park, No. 3011, Shahexi
Address ...................................... :
                                                   Road, Nanshan, Shenzhen 518055 China.
Applicant’s name ..................... :           Shenzhen Powerqi Technology Co., Ltd.
                                                   2nd Floor, A4 Building, Block A, Fangxing Science & Tech.
Address ...................................... :
                                                   Park, Longgang District, Shenzhen, China
Test specification ..................... :
Standard..................................... :    FCC CFR 47 part1, 1.1307(b), 1.1310
TRF Originator ........................... :       Shenzhen CTL Testing Technology Co., Ltd.
Master TRF ................................ :      Dated 2011-01
Test item description ............... :            Wireless Charging Pad
FCC ID ....................................... :   2AFP2FC40
Trade Mark ................................. :     N/A
Model/Type reference ................ :            FC40, FC45
Transmit Frequency .................. :            115~205KHz
Antenna type .............................. :      Loop antenna
Date of receipt of test item ............: Jul. 15, 2019
Date of sampling ...........................: Jul. 15, 2019
Date of Test Date ..........................: Jul. 15, 2019–Jul. 30, 2019
Data of Issue .................................: Jul. 31, 2019
Result ............................................: Pass
Shenzhen CTL Testing Technology Co., Ltd. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as
the Shenzhen CTL Testing Technology Co., Ltd. is acknowledged as copyright owner and source
of the material. Shenzhen CTL Testing Technology Co., Ltd. takes no responsibility for and will
not assume liability for damages resulting from the reader's interpretation of the reproduced
material due to its placement and context.


V1.0                              Page 2 of 9              Report No.: CTL1907031011-MPE


                               TEST REPORT
                                                                                        Jul. 31, 2019
 Test Report No. :               CTL1907031011-MPE             ________________________________________________________________________________________


                                                                                        Date of issue


   Equipment under        :
                              Wireless Charging Pad
   Test


   Type / Model(s)        :   FC40, FC45


   Applicant              :   Shenzhen Powerqi Technology Co., Ltd.


   Address                :   2nd Floor, A4 Building, Block A, Fangxing Science & Tech. Park,
                              Longgang District, Shenzhen, China


   Manufacturer           :   Shenzhen Powerqi Technology Co., Ltd.


   Address                :   2nd Floor, A4 Building, Block A, Fangxing Science & Tech. Park,
                              Longgang District, Shenzhen, China




         Test Result                                       PASS
 The test results presented in this report relate only to the object tested.
 This report shall not be reproduced, except in full, without the written approval of the issuing
 testing laboratory.


 V1.0                             Page 3 of 9             Report No.: CTL1907031011-MPE


                                        Contents

1.      SUMMARY ....................................................................... 4

1.1.    EUT configuration                                                                 4

2.      TEST ENVIRONMENT......................................................... 4

2.1.    Address of the test laboratory                                                    4
2.2.    Test Facility                                                                     4
2.3.    Environmental conditions                                                          5
2.4.    Statement of the measurement uncertainty                                          5

3.      METHOD OF MEASUREMENT .............................................. 6

3.1.    Applicable Standard                                                               6
3.2.    Limit                                                                             6

4.      TEST RESULT .................................................................. 7

4.1.    Test Setup                                                                        7
4.2.    Test Equipment                                                                    7

HI3637 .................................................................................... 7

4.3.    Measurement Procedure                                                             7
4.4.    Equipment Approval Considerations                                                 7
4.5.    E and H field Strength                                                            8

5.      TEST SETUP PHOTO ......................................................... 9


 V1.0                                  Page 4 of 9                Report No.: CTL1907031011-MPE


1. SUMMARY

1.1. EUT configuration
Kind of Product                                       Wireless Charging Pad
Model Name                                            FC40, FC45
Frequency Range                                       115-205KHz
Antenna Type                                          Inductive loop coil antenna
FCC ID                                                2AFP2FC40

2. TEST ENVIRONMENT

2.1. Address of the test laboratory
Shenzhen CTL Testing Technology Co., Ltd.
Floor 1-A, Baisha Technology Park, No.3011, Shahexi Road, Nanshan District, Shenzhen, China
518055

The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.10 (2013)
and CISPR Publication 32.

2.2. Test Facility
The test facility is recognized, certified, or accredited by the following organizations:
CNAS-Lab Code: L7497

Shenzhen CTL Testing Technology Co., Ltd. has been assessed and proved to be in compliance
with CNAS-CL01 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC
17025: 2005 General Requirements) for the Competence of Testing and Calibration Laboratories.

A2LA-Lab Cert. No. 4343.01

Shenzhen CTL Testing Technology Co., Ltd, EMC Laboratory has been accredited by A2LA for
technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC
17025: 2005 General Requirements for the Competence of Testing and Calibration Laboratories
and any additional program requirements in the identified field of testing.

IC Registration No.: 9518B

CAB identifier: CN0041
The 3m alternate test site of Shenzhen CTL Testing Technology Co., Ltd. EMC Laboratory has
been registered by Innovation, Science and Economic Development Canada to test to Canadian
radio equipment requirements with Registration No.: 9518B on Jan. 22, 2019.
FCC-Registration No.: 399832

Designation No.: CN1216
Shenzhen CTL Testing Technology Co., Ltd. EMC Laboratory has been registered and fully
described in a report filed with the (FCC) Federal Communications Commission. The acceptance
letter from the FCC is maintained in our files. Registration 399832, December 08, 2017.


 V1.0                               Page 5 of 9             Report No.: CTL1907031011-MPE


2.3. Environmental conditions
During the measurement the environmental conditions were within the listed ranges:

  Temperature:                          15-35 ° C

  Humidity:                             30-60 %

  Atmospheric pressure:              950-1050mbar

2.4. Statement of the measurement uncertainty
Where relevant, the following measurement uncertainty levels have been estimated for tests
performed on the apparatus:


 V1.0                                Page 6 of 9              Report No.: CTL1907031011-MPE


3. Method of measurement
3.1. Applicable Standard
According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated
in a manner that ensures that the public is not exposed to radio frequency energy level in excess of
the Commission’s guidelines.
According to §1.1310 and §2.1091 RF exposure is calculated.
According KDB 680106 D01 RF Exposure Wireless Charging App v03

3.2. Limit
Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure

                                                                        Averaging
  Frequency       Electric Field   Magnetic Field   Power Density
                                                                          Time
 Range(MHz)       Strength(V/m)    Strength(A/m)      (mW/cm²)
                                                                         (minute)
                    Limits for Occupational/Controlled Exposure
  0.3 – 3.0
                       614               1.63           (100) *              6
  3.0 – 30
                      1842/f            4.89/f          (900/f)*             6
  30 – 300
                       61.4             0.163              1.0               6
 300 – 1500
                         /                 /             f/300               6
   1500 –
                         /                 /                5                6
  100,000

Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure

                                                                        Averaging
  Frequency       Electric Field   Magnetic Field   Power Density
                                                                          Time
 Range(MHz)       Strength(V/m)    Strength(A/m)      (mW/cm²)
                                                                         (minute)
                    Limits for Occupational/Controlled Exposure
  0.3 – 3.0
                       614               1.63           (100) *             30
  3.0 – 30
                      824/f             2.19/f          (180/f)*            30
  30 – 300
                      27.5              0.073              0.2              30
 300 – 1500
                        /                  /             f/1500             30
   1500 –
                        /                  /               1.0              30
  100,000

F=frequency in MHz
*=Plane-wave equivalent power density


 V1.0                               Page 7 of 9              Report No.: CTL1907031011-MPE


4. Test Result
4.1. Test Setup




Note: A, B, C, D, E, F for six surfaces of the product.

4.2. Test Equipment
                                                                    Calibrated       Calibrated
 Equipment       Manufacturer        Model          Serial no.
                                                                       date             until
E-Field Probe     HOLADAY            HI3637         00052130        2019.05.24       2020.05.23
H-Field Probe     HOLADAY            HI3637         00052130        2019.05.24       2020.05.23

4.3. The charger support DC 5V/2A and DC 9V/1.67A input modes, this 2 modes all have been
     tested, only worse case DC 5V/2A input mode was reported.

4.4. Measurement Procedure
a) The RF exposure test was performed on 360 degree turn table in anechoic chamber.
b) The measurement probe was placed at test distance (10cm) which is between the edge of the
   charger and the geometric centre of probe.
c) The turn table was rotated 360d degree to search of highest strength.
d) The highest emission level was recorded and compared with limit as soon as measurement of
   each points (A, B, C, D, E) were completed.
e) The EUT were measured according to the dictates of KDB 680106 D01 RF Exposure Wireless
   Charging App v03.

4.5. Equipment Approval Considerations
The EUT does comply with KDB 680106 D01 RF Exposure Wireless Charging App v03.
   (1) Power transfer frequency is less than 1 MHz..
    (2) Output power from each primary coil is less than or equal to 15 watts.
    (3) The transfer system includes only single primary and secondary coils. This includes
   charging systems that may have multiple primary coils and clients that are able to detect and
   allow coupling only between individual pairs of coils.
    (4) Client device is placed directly in contact with the transmitter.
    (5) Mobile exposure conditions only (portable exposure conditions are not covered by this
   exclusion).
    (6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top
   surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the
   MPE limit.
   Remark: Meet all the above requirements.


 V1.0                              Page 8 of 9             Report No.: CTL1907031011-MPE


4.6. E and H field Strength
Test mode for wireless charger: Normal Operation (Charging mode)

E-Filed Strength at 15 cm from the edges surrounding the EUT
Frequency
                Test         Test       Test       Test      Limits
  Range
             Position A Position B Position C Position D     (V/m)
  (MHz)
   0.123        2.16         2.02       2.39       2.37      614.0

E-Filed Strength at 20 cm from the top of the EUT (V/m)
Frequency
                Test       Limits
  Range
             Position E    (V/m)
  (MHz)
   0.123        1.13       614.0

H-Filed Strength at 15 cm from the edges surrounding the EUT
Frequency
                Test         Test       Test        Test     Limits
  Range
             Position A Position B Position C Position D     (A/m)
  (MHz)
   0.123       0.352        0.347      0.348       0.341      1.63

H-Filed Strength at 20 cm from the top of the EUT (V/m)
Frequency
                Test       Limits
  Range
             Position E    (A/m)
  (MHz)
   0.123       0.231        1.63

Test mode for wireless charger: Normal Operation (No load mode)
E-Filed Strength at 15 cm from the edges surrounding the EUT
Frequency
                 Test        Test        Test          Test     Limits
  Range
              Position A Position B Position C Position D       (V/m)
  (MHz)
   0.123         0.33        0.29        0.35          0.32     614.0

E-Filed Strength at 20 cm from the top of the EUT (V/m)
Frequency
                Test       Limits
  Range
             Position E    (V/m)
  (MHz)
   0.123        0.18       614.0

H-Filed Strength at 15 cm from the edges surrounding the EUT
Frequency
                Test         Test       Test       Test      Limits
  Range
             Position A Position B Position C Position D     (A/m)
  (MHz)
   0.123       0.103         0.96      0.101       0.97       1.63

H-Filed Strength at 20 cm from the top of the EUT (V/m)
Frequency
                Test       Limits
  Range
             Position E    (A/m)
  (MHz)
   0.123       0.067        1.63


V1.0                      Page 9 of 9                Report No.: CTL1907031011-MPE


5. Test Setup Photo




          .......................End of Report.........................



Document Created: 2019-08-08 19:42:25
Document Modified: 2019-08-08 19:42:25

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC