RF Exposure Info

FCC ID: 2AFP2-FD01

RF Exposure Info

Download: PDF
FCCID_4248281

                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                 Shenzhen Branch




                                                                    Report No.: SZEM190201087302
                                                                    Page:        1 of 8


                       Human Exposure Report
Application No.:           SZEM1902010873CR
Applicant:                 Shenzhen Powerqi Technology Co., Ltd.
Address of Applicant:      2nd Floor, A4 Building, Block A Fangxing Science & Tech. Park, Longgang
                           District, Shenzhen 518116, China
Manufacturer:              Shenzhen Powerqi Technology Co., Ltd.
Address of Manufacturer:   2nd Floor, A4 Building, Block A Fangxing Science & Tech. Park, Longgang
                           District, Shenzhen 518116, China
Factory:                   Shenzhen Powerqi Technology Co., Ltd.
Address of Factory:        2nd Floor, A4 Building, Block A Fangxing Science & Tech. Park, Longgang
                           District, Shenzhen 518116, China
Equipment Under Test (EUT):
EUT Name:                      Dual Wireless Charger
Model No.:                     FD01
FCC ID:                        2AFP2-FD01
Standards:                     47 CFR PART 1, Subpart I, Section 1.1310
Date of Receipt:               2019-02-01
Date of Test:                  2019-02-15 to 2019-03-19
Date of Issue:                 2019-03-21
Test Result :                    Pass*
* In the configuration tested, the EUT complied with the standards specified above




            Keny Xu
      EMC Laboratory Manager


                                               SGS-CSTC Standards Technical Services Co., Ltd.
                                               Shenzhen Branch
                                                                                                    Report No.: SZEM190201087302
                                                                                                    Page:       2 of 8




1         Contents
                                                                                                                                                           Page
1      CONTENTS ................................................................................................................................................2

2      GENERAL INFORMATION ........................................................................................................................3
    2.1    DETAILS OF E.U.T. ...................................................................................................................................3
    2.2    DESCRIPTION OF SUPPORT UNITS .............................................................................................................3
    2.3    TEST LOCATION ........................................................................................................................................4
    2.4    TEST FACILITY ..........................................................................................................................................4
    2.5    DEVIATION FROM STANDARDS ...................................................................................................................4
    2.6    ABNORMALITIES FROM STANDARD CONDITIONS..........................................................................................4
3      EQUIPMENTS USED DURING TEST ........................................................................................................5

4      TEST RESULTS .........................................................................................................................................6
    4.1 RF EXPOSURE TEST .................................................................................................................................6
       4.1.1 E.U.T. Operation ............................................................................................................................6
       4.1.2 Measurement Data.........................................................................................................................7
5      PHOTOGRAPHS- RF EXPOSURE SETUP PHOTOS...............................................................................8


                           SGS-CSTC Standards Technical Services Co., Ltd.
                           Shenzhen Branch
                                                            Report No.: SZEM190201087302
                                                            Page:       3 of 8




2   General Information
2.1 Details of E.U.T.
    Power supply:          Input: DC12V, 2.5A;
                           Output: 5W/7.5W/10W x 2;
                           AC/DC Adapter:
                           Model: KC30W02-120250MG;
                           Input: AC 100-240V,50/60Hz
                           Output: DC12V, 2.5A
    Operation Frequency:   110kHz to 205kHz
    Modulation Type:       Load Modulation
    Antenna Type:          Loop Antenna
    Remark:                Tests were conducted in all three load modes and the worst case(10W) is
                           reported only.



2.2 Description of Support Units
    Description              Manufacturer               Model No.                 Serial No.
    Electronic Load 1            SGS                        N/A                      N/A
    Electronic Load 2            SGS                        N/A                      N/A


                              SGS-CSTC Standards Technical Services Co., Ltd.
                              Shenzhen Branch
                                                                Report No.: SZEM190201087302
                                                                Page:       4 of 8



2.3 Test Location
     All tests were performed at:
     SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Branch E&E Lab,
     No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong,China
     518057.
     Tel: +86 755 2601 2053         Fax: +86 755 2671 0594
     No tests were sub-contracted.
2.4 Test Facility
    The test facility is recognized, certified, or accredited by the following organizations:
    • CNAS (No. CNAS L2929)
    CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
    Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
    Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
    Laboratories) for the competence in the field of testing.
    • A2LA (Certificate No. 3816.01)
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
    American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
    • VCCI
    The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz,
    Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
    Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have
    been registered in accordance with the Regulations for Voluntary Control Measures with Registration
    No.: G-20026, R-14188, C-12383 and T-11153 respectively.
    • FCC –Designation Number: CN1178
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    as an accredited testing laboratory.
    Designation Number: CN1178. Test Firm Registration Number: 406779.
    • Innovation, Science and Economic Development Canada
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    by ISED as an accredited testing laboratory.
    CAB identifier: CN0006.
    IC#: 4620C.
2.5 Deviation from Standards
    None.
2.6 Abnormalities from Standard Conditions
    None.


                        SGS-CSTC Standards Technical Services Co., Ltd.
                        Shenzhen Branch
                                                  Report No.: SZEM190201087302
                                                  Page:       5 of 8




3   Equipments Used during Test

                                                        Inventory
    Item   Test Equipment    Manufacturer   Model No.               Cal. Due date
                                                           No.

     1     Shielding Room      SAEMC        MSR733      SEM001-09     2020-05-09

            Electric and
     2     Magnetic Field       Narda       EHP-50F      EMC092       2019-05-06
             Analyzer


                                SGS-CSTC Standards Technical Services Co., Ltd.
                                Shenzhen Branch
                                                                     Report No.: SZEM190201087302
                                                                     Page:       6 of 8




4     Test Results
4.1 RF Exposure test
      Test Requirement:                 47 CFR PART 1, Subpart I, Section 1.1310
      Measurement Distance:             15/20cm
      Limit:

    Frequency range Electric field strength Magnetic field strength Power density Averaging time
         (MHz)               (V/m)                  (A/m)             (mW/cm2)      (minutes)
                            (A) Limits for Occupational/Controlled Exposures
         0.3-3.0                 614                        1.63               *(100)             6
          3.0-30                1842/f                     4.89/f             *(900/f2)           6
         30-300                  61.4                      0.163                   1.0            6
        300-1500                    /                         /                f/300              6
      1500-100,000                  /                         /                    5              6
                         (B) Limits for General Population/Uncontrolled Exposure
         0.3-1.34                614                        1.63               *(100)             30
         1.34-30                824/f                      2.19/f             *(180/f2)           30
         30-300                  27.5                      0.073                   0.2            30
        300-1500                    /                         /                f/1500             30
      1500-100,000                  /                         /                    1.0            30
    F=frequency in MHz
    *=Plane-wave equivalent power density
    RF exposure compliance will need to be determined with respect to 1.1307(c) and (d) of the FCC rules.
    The emissions should be within the limits at 300kHz in Table 1 of 1.1310(use the 300kHz limits for
    150kHz:614V/m,1.63A/m).
4.1.1 E.U.T. Operation
      Operating Environment:
      Temperature:        25.0 °C           Humidity:    52 % RH         Atmospheric Pressure: 1015 mbar
      EUT Operation:
      This device has been tested the worst status of full load and the device has been tested with load at
       zero charge, intermediate charge, and full charge.


                                SGS-CSTC Standards Technical Services Co., Ltd.
                                Shenzhen Branch
                                                           Report No.: SZEM190201087302
                                                           Page:       7 of 8




4.1.2 Measurement Data


     For Each antenna, Output Voltage=DC 12V; The max output power =10W;Calculation of resistor
     value=14.4Ω
     Electric Field Emissions
        Operation      Test Distance       Test       Probe Measure       50% Limit
        frequency                        Position      Result (V/m)
                            (cm)                                            (V/m)
                                15        Side 1            1.43             307
                                15        Side 2            1.08             307
        147.2 kHz               15        Side 3            1.36             307
                                15        Side 4            1.12             307
                                20         Top              1.25             307


     Magnetic Field Emissions
        Operation        Test Distance     Test       Probe Measure       50% Limit
        frequency                        Position      Result (A/m)
                                (cm)                                        (A/m)
                                15        Side 1           0.0173           0.815
                                15        Side 2           0.0129           0.815
        147.2 kHz               15        Side 3           0.0161           0.815
                                15        Side 4           0.0134           0.815
                                20          Top            0.0132           0.815


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                            Report No.: SZEM190201087302
                                                            Page:       8 of 8




5   Photographs- RF exposure Setup photos
    Refer to setup photos.


                                    - End of the Report -



Document Created: 2019-04-19 06:54:05
Document Modified: 2019-04-19 06:54:05

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC