Test Report

FCC ID: 2AFP2-FD01

Test Report

Download: PDF
FCCID_4248279

                                  SGS-CSTC Standards Technical Services Co., Ltd.
                                  Shenzhen Branch




                                                                     Report No.: SZEM190201087301
                                                                     Page:        1 of 16


                                    TEST REPORT
Application No.:                SZEM1902010873CR
Applicant:                      Shenzhen Powerqi Technology Co., Ltd.
Address of Applicant:           2nd Floor, A4 Building, Block A Fangxing Science & Tech. Park, Longgang
                                District, Shenzhen 518116, China
Manufacturer:                   Shenzhen Powerqi Technology Co., Ltd.
Address of Manufacturer:        2nd Floor, A4 Building, Block A Fangxing Science & Tech. Park, Longgang
                                District, Shenzhen 518116, China
Factory:                        Shenzhen Powerqi Technology Co., Ltd.
Address of Factory:             2nd Floor, A4 Building, Block A Fangxing Science & Tech. Park, Longgang
                                District, Shenzhen 518116, China
Equipment Under Test (EUT):
EUT Name:                       Dual Wireless Charger
Model No.:                      FD01
FCC ID:                         2AFP2-FD01
Standard(s) :                   47 CFR Part 18
Date of Receipt:                2019-02-01
Date of Test:                   2019-02-15 to 2019-03-19
Date of Issue:                  2019-03-21
Test Result:                    Pass*
* In the configuration tested, the EUT complied with the standards specified above.




             Keny Xu
       EMC Laboratory Manager


                           SGS-CSTC Standards Technical Services Co., Ltd.
                           Shenzhen Branch
                                                          Report No.: SZEM190201087301
                                                          Page:       2 of 16



                                        Revision Record
     Version       Chapter              Date                 Modifier       Remark

     01                              2019-03-21                             Original




Authorized for issue by:




                             Harry Wu /Project Engineer




                             Eric Fu /Reviewer


                          SGS-CSTC Standards Technical Services Co., Ltd.
                          Shenzhen Branch
                                                     Report No.: SZEM190201087301
                                                     Page:       3 of 16



2   Test Summary
    Radio Spectrum Matter Part
            Item            Standard      Method              Requirement     Result
        Conducted
                         47 CFR Part 18   FCC MP-5            Part 18.307      Pass
        disturbance
     Radiated emission   47 CFR Part 18   FCC MP-5            Part 18.305      Pass


                                                          SGS—CSTC Standards Technical Services Co., Ltd.
                                                          Shenzhen Branch

                                                                                                                                    Report No.: SZEM190201087301
                                                                                                                                    Page:                    4 of 16



3          Contents
                                                                                                                                                                                                    Page
          COVER PAGE ..... .. . . . . ... mm mmmmmmmmcmmnnnneiennnnnnnnnnnnnn in en n n n n n n n n n nn ns 1

          TEST SUMMARY ......22000000000rrrsrsssrsssssssrrsssrrrrrrrrrrsrrrssassssrrssrrrsssarsrsaaassssssssrrrsrrrsssaarsaaaassaasssrar iss rssssaaaakaaassknn8 3

          CONT ENTS ... . . . . . . ... cmmmmmcmmcmnnnnne ie nnnnnnnnnnnnnn in en n n n n n n n n n nn en n 4

          (e]3 ) (3 27.\M | y 201 51 ;‘ /J (o|) oo 5

    4.1           Dsy( hS¥ ola S Un ooo 5
    4.2           DESCRIPTION OF SUPPORT UNITS .222222222222222+2244 se vvverrvsrrsrrrre tss s se rrsrrsrrrrrrrsrrrsr es s se rrrrerrrrer ie e e es se e e e e e ks ie es 5
    4.3           MEASUREMENT UNCERTAINTY 1..222222000022++¥¥¥¥+ssssessvsv¥srrssrrssssssrssssssrsssssrrrsrrrssssssrsssserrrrerrrrerrr e e es se e e e r e kss r e 6k 5
    4.4           J[Ssp Koloue e 6
    4.5           SS 2i e 6
    4.6           DEVIATION FROM STANDARDS...112222222022222+++¥¥rrvvevsvvvvrrrrrrrsrrrsrrssssrrssrrrrrrrrrrsrrssrrsssrerrrrerrrrerrr e e es se e e e e e ks ie es 6
    4.7           ABNORMALITIES FROM STANDARD CGONDITIONS ...22222222222222222++46444vevvvvrrrrrrrrrrrrsv es r se es rerrrrrrrrrerrra e e e r e e ks i 664 6
          EQUIPMENT LIST ....0000000000000rrrse e e e es sn sns rrrrrrrrrrrarrraras sns iss rrrr snn aa n n ns ns ns n rrn n rrr n in n n n n snn n n n n n n n n n n n n n n n n n n n 7

          RADIO SPECTRUM MATTER TEST RESULTS......00000000rrrrrrrrrrsressrssssrrrrsrrrrrssrrrsaassssrsssrrrssrrsrsaaaaaaassskans 8

    6.1      CONDUCTED DISTURBANCE ....22222222222+¥+22ressse¥rrrerrrrrrrrerrss se se ssrrrrrrrrrrrsrrssrr se rrrrerrrrrr ie e e ies e e r e e e e i ie i ie e en es 8
       i e.cei e 8
       oe       Eseipleen e 8
       6.1.3    Measureme@nt PrOC@UJUTG @MQ D@LQ.............222220222000002222222rrrrrrrrrrrrrr es s s s s s s se a k e e e e e e e aaaaaaaaaeaaaeeeee0 + 8
    6.2      RADIATED EMISSION 1.222222222222++22646eveevvrrrrrrrrrrssssesssssrrssrrrrrsssrsrsssssesssrrrrrrsrrrrsrrs ies se e e es se rrrrrerrrerrr e e e e e e e es 11
       eAe.ceWe 12
       olscipleen e 12
       6.2.3    Measurement PrOC@UUTG @MQ D@LQ.............22222222200000222222srrrrrrrrrrrrrr es s s s s s se e k k k k k k k k e e aaaaaaeeeeeeeees 12
          PHOTOGRAPHS ... 11 00000000000rrrrre e e e esn rrssrrrsrrrrrrrrrrrara s snn sns s inss rr n a n n n n snn n r n n n n n n n n n n n n n n n n n n n n n n en n n n n n n n n n 16

    7.1           TEST SETUP...2222220222eee¥rrrrrrssessssvrrrrerrrrrssssrsssssesssrrrrrrerrrsssssrrssserrrrerrrrrsrssrrsssrrrrsserrrrrsrrre ies e es se e e e ie ks rrees 16
    7.2           EUT CGONSTRUCTIONAL DETAILS (EUT PHOTOS)...222222222222222+¥¥ e e e vvvvvvrrrrrrrrrrrrerrrrrrrrrrrrrrrrerrrer en a e e e e e es 16




                                          Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed
                                          overleaf, available on request or accessible at http://www.sqs.com/en/Terms—and—Conditions.aspx and, for electronic format documents,
                                          subject to Terms and Conditions for Electronic Documents at http://www.sqs.com/en/Terms—and—Conditions/Terms—e—Document.aspx.
                                          Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is
                                          advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the limits of
                                          Client‘s instructions, if any. The Company‘s sole responsibility is to its Client and this document does not exonerate parties to a
                                          transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced
                                          except in full, without prior written approval of the Company. Any unauthorized alteration, for$ery or falsification of the content or
                                          appearance of this document is unlawful and offenders may be prosecuted to the fullest extent         the law. Unless otherwise stated the
                                          results shown in this test report refer onl¥ to the sample(s) tested and such sample(s) are retained for 30 days only.
                                          Attention: To check the authenticity of testing /inspection report & certificate, please contact us at telephone: (86—755) 8307 1443,
                                          or email: CN.Doccheck@sgs.com
                                    . Ltd. No.1 Workshop, M—10, Middle Section, Science & Technology Park, Shenzhen, China 518057   t (86—755) 26012053 f (86—755) 26710594   www.sgsgroup.com.cn
                                              +5 —~Xil — HKRMFHEM—10K—SJB                                       MB&4: 518057        t (86—755) 26012053 f (86—755) 26710594   sgs.china@sgs.com
                                          I
                                                                                                                                                       Member of the SGS Group (SGS SA)


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                             Report No.: SZEM190201087301
                                                             Page:       5 of 16


4   General Information
4.1 Details of E.U.T.
    Power supply:            Input: DC12V, 2.5A;
                             Output: 5W/7.5W/10W x 2;
                             AC/DC Adapter:
                             Model: KC30W02-120250MG;
                             Input: AC 100-240V,50/60Hz
                             Output: DC12V, 2.5A
    Antenna Type:            Loop Antenna
    Modulation Type:         Load Modulation
    Operation Frequency:     110kHz to 205kHz


4.2 Description of Support Units
    Description                  Manufacturer             Model No.                   Serial No.
    Mobile Phone                  SAMSUNG                 SM-G9500                 R28J9140LPB
    iPhone 8                         Apple                 A1863                 F4GVQ656JC6D



4.3 Measurement Uncertainty

      No.                           Item                         Measurement Uncertainty
       1                      Radio Frequency                             ± 7.25 x 10-8
       2                         Duty cycle                                 ± 0.37%
       3                    Occupied Bandwidth                               ± 3%
       4                    RF conducted power                              ± 0.75dB
       5                      RF power density                              ± 2.84dB
       6               Conducted Spurious emissions                         ± 0.75dB
                                                                      ± 4.5dB (below 1GHz)
       7                     RF Radiated power
                                                                      ± 4.8dB (above 1GHz)
                                                                      ± 4.5dB (Below 1GHz)
       8               Radiated Spurious emission test
                                                                      ± 4.8dB (Above 1GHz)
       9                      Temperature test                               ± 1°C
       10                       Humidity test                                ± 3%
       11                     Supply voltages                               ± 1.5%
       12                           Time                                     ± 3%


                            SGS-CSTC Standards Technical Services Co., Ltd.
                            Shenzhen Branch
                                                               Report No.: SZEM190201087301
                                                               Page:       6 of 16


4.4 Test Location
    All tests were performed at:
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Branch
    No. 1 Workshop, M-10, Middle Section, Science & Technology Park, Shenzhen, Guangdong, China.
    518057.
    Tel: +86 755 2601 2053        Fax: +86 755 2671 0594
    No tests were sub-contracted.
4.5 Test Facility
    The test facility is recognized, certified, or accredited by the following organizations:
    • CNAS (No. CNAS L2929)
    CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
    Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
    Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
    Laboratories) for the competence in the field of testing.
    • A2LA (Certificate No. 3816.01)
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
    American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
    • VCCI
    The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz,
    Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
    Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have
    been registered in accordance with the Regulations for Voluntary Control Measures with Registration
    No.: G-20026, R-14188, C-12383 and T-11153 respectively.
    • FCC –Designation Number: CN1178
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    as an accredited testing laboratory.
    Designation Number: CN1178. Test Firm Registration Number: 406779.
    • Innovation, Science and Economic Development Canada
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    by ISED as an accredited testing laboratory.
    CAB identifier: CN0006.
    IC#: 4620C.
4.6 Deviation from Standards
    None
4.7 Abnormalities from Standard Conditions
    None


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Shenzhen Branch
                                                                 Report No.: SZEM190201087301
                                                                 Page:       7 of 16



5      Equipment List
Conducted disturbance
        Equipment           Manufacturer         Model No      Inventory No    Cal Date    Cal Due Date
      Shielding Room      ChangZhou ZhongYu       GB-88        SEM001-06      2017-05-10    2020-05-09
Measurement Software            AUDIX          e3 V5.4.1221d       N/A           N/A           N/A
       Coaxial Cable             SGS               N/A         SEM024-01      2018-07-12    2019-07-11
           LISN            Rohde & Schwarz       ENV216        SEM007-01      2018-09-25    2019-09-24
           LISN            ETS-LINDGREN           3816/2       SEM007-02      2018-04-02    2019-04-01
     EMI Test Receiver     Rohde & Schwarz         ESCI        SEM004-02      2018-04-02    2019-04-01


Radiated emission
        Equipment           Manufacturer         Model No      Inventory No    Cal Date    Cal Due Date
    10m Semi-Anechoic
                               SAEMC            FSAC1018       SEM001-03      2018-03-31    2021-03-30
        Chamber
                                               e3 V8.2014-6-
Measurement Software            AUDIX                              N/A           N/A           N/A
                                                    27
       Coaxial Cable             SGS               N/A         SEM029-01      2018-07-12    2019-07-11
     EMI Test Receiver
                           Rohde & Schwarz         ESR         SEM004-03      2018-04-02    2019-04-01
       (9kHz-7GHz)
   Trilog-Broadband
                             Schwarzbeck        VULB9168       SEM003-18      2016-06-29    2019-06-28
Antenna(30MHz-1GHz)
                          Sonoma Instrument
       Pre-amplifier                               310N        SEM005-04      2018-04-13    2019-04-12
                                Co
    Active Loop Antenna      ETS-Lindgren          6502        SEM003-08      2017-08-22    2020-08-21


General used equipment
        Equipment           Manufacturer         Model No      Inventory No    Cal Date    Cal Due Date
                               Shanghai
Humidity/ Temperature
                             Meteorological       ZJ1-2B       SEM002-03      2018-09-27    2019-09-26
      Indicator
                            Industry Factory
                               Shanghai
Humidity/ Temperature
                             Meteorological       ZJ1-2B       SEM002-04      2018-09-27    2019-09-26
      Indicator
                            Industry Factory
Humidity/ Temperature
                                Mingle             N/A         SEM002-08      2018-09-27    2019-09-26
      Indicator
                              Changchun
        Barometer            Meteorological       DYM3         SEM002-01      2018-04-08    2019-04-07
                            Industry Factory


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Shenzhen Branch
                                                             Report No.: SZEM190201087301
                                                             Page:       8 of 16




6    Radio Spectrum Matter Test Results
6.1 Conducted disturbance
     Test Requirement         Part 18.307
     Test Method:             FCC MP-5
     Limit:

                                                                  Conducted limit (dBµV)
             Frequency of emission (MHz)                       Quasi-peak             Average
0.15-0.5                                                66 to 56*                56 to 46*
0.5-5                                                   56                       46
5-30                                                    60                       50
      *Decreases with the logarithm of the frequency.



6.1.1 E.U.T. Operation
      Operating Environment:
      Temperature:      21.9 °C       Humidity: 64.6 % RH       Atmospheric Pressure: 1020   mbar
      Pretest these     a:Charge mode_Keep the EUT charging(5W).
      modes to find     b:Charge mode_Keep the EUT charging(7.5W).
      the worst case:
                        c:Charge mode_Keep the EUT charging(10W).
      The worst case    c:Charge mode_Keep the EUT charging(10W).
      for final test:
6.1.2 Test Setup Diagram




6.1.3 Measurement Procedure and Data


                         SGS-CSTC Standards Technical Services Co., Ltd.
                         Shenzhen Branch
                                               Report No.: SZEM190201087301
                                               Page:       9 of 16

Mode:c; Line:Live Line


                            SGS-CSTC Standards Technical Services Co., Ltd.
                            Shenzhen Branch
                                                  Report No.: SZEM190201087301
                                                  Page:       10 of 16

Mode:c; Line:Neutral Line


                                   SGS-CSTC Standards Technical Services Co., Ltd.
                                   Shenzhen Branch
                                                                    Report No.: SZEM190201087301
                                                                    Page:       11 of 16



6.2 Radiated emission
         Test Requirement      Part 18.305
         Test Method:          FCC MP-5
         Measurement Distance: 3m
         Limit:




1Fieldstrength may not exceed 10 µV/m at 1600 meters. Consumer equipment operating below 1000 MHz is
not permitted the increase in field strength otherwise permitted here for power over 500 watts.
2Reduced     to the greatest extent possible.
3Field  strength may not exceed 10 µV/m at 1600 meters. Consumer equipment is not permitted the increase
in field strength otherwise permitted here for over 500 watts.
4Induction cooking ranges manufactured prior to February 1, 1980, shall be subject to the field strength limits
for miscellaneous ISM equipment.


                              SGS-CSTC Standards Technical Services Co., Ltd.
                              Shenzhen Branch
                                                               Report No.: SZEM190201087301
                                                               Page:       12 of 16


6.2.1 E.U.T. Operation
      Operating Environment:
      Temperature:      25 °C         Humidity: 51 % RH         Atmospheric Pressure: 1020       mbar
      Pretest these     a:Charge mode_Keep the EUT charging(5W).
      modes to find the b:Charge mode_Keep the EUT charging(7.5W).
      worst case:
                        c:Charge mode_Keep the EUT charging(10W).
      The worst case    c:Charge mode_Keep the EUT charging(10W).
      for final test:
6.2.2 Test Setup Diagram




6.2.3 Measurement Procedure and Data

     Test Procedure:   a. The EUT was placed on the top of a rotating table 0.8 meters above the ground
                          at a 3 meter semi-anechoic chamber(30MHz-1000MHz) and 3 meter semi-
                          anechoic chamber(9kHz-30MHz). The table was rotated 360 degrees to
                          determine the position of the highest radiation.
                       b. The EUT was set 10 meters(30MHz-1000MHz) and 10 meter (9kHz-30MHz)
                          away from the interference-receiving antenna, which was mounted on the top of
                          a variable-height antenna tower.
                       c.   Above 30MHz: The Analyzer/Receiver scanned from 30MHz to 1000MHz.The
                            antenna height is varied from one meter to four meters above the ground to


       SGS-CSTC Standards Technical Services Co., Ltd.
       Shenzhen Branch
                                          Report No.: SZEM190201087301
                                          Page:       13 of 16

     determine the maximum value of the field strength. Both horizontal and vertical
     polarizations of the antenna are set to make the measurement.
d. Below 30MHz: The Analyzer/Receiver scanned from 9kHz to 30MHz.The
   antenna height is 2 meters above the ground to determine the maximum value
   of the field strength.
e. For each suspected emission, the EUT was arranged to its worst case and then
   the antenna was tuned to heights from 1 meter to 4 meters (for the test
   frequency of below 30MHz, the antenna was tuned to heights 2 meter) and the
   rotatable table was turned from 0 degrees to 360 degrees to find the maximum
   reading.
f.   The test-receiver system was set to Peak Detect Function and Specified
     Bandwidth with Maximum Hold Mode.
g. If the emission level of the EUT in peak mode was 10dB lower than the limit
   specified, then testing could be stopped and the peak values of the EUT would
   be reported. Otherwise the emissions that did not have 10dB margin would be
   re-tested one by one using peak, quasi-peak or average method as specified
   and then reported in a data sheet.
h. Repeat above procedures until all frequencies measured was complete.
i.   Measurement Requirement:
1)This product belongs to non-ISM equipment, the field strength limit is 15uV/m at
300 meter distance.
2)Limit: 20log(15uV/m) +20log (300/3) =23.52+40=63.52dBuV/m at 3 meters
distance


              SGS-CSTC Standards Technical Services Co., Ltd.
              Shenzhen Branch
                                    Report No.: SZEM190201087301
                                    Page:       14 of 16

Mode c:
9kHz-150kHz


               SGS-CSTC Standards Technical Services Co., Ltd.
               Shenzhen Branch
                                     Report No.: SZEM190201087301
                                     Page:       15 of 16

Mode c:
150kHz-30MHz


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                                 Report No.: SZEM190201087301
                                                                 Page:       16 of 16



7   Photographs
7.1 Test Setup
    Please refer to setup photos.

7.2 EUT Constructional Details (EUT Photos)
    Please Refer to external and internal photos for details.


                                         - End of the Report -



Document Created: 2019-04-15 05:47:33
Document Modified: 2019-04-15 05:47:33

© 2025 FCC.report