                                                   RF EXPOSURE REPORT
Report Reference No. ..................... :             CTL1906131022-MPE
Compiled by
                                                                       Happy Guo
( position+printed name signature) ... :                          (File administrators)
Supervised by
                                                                     Nice Nong
( position+printed name+signature).. :                             (Test Engineer)
Approved by                                                            Ivan Xie
( position+printed name+signature).. :                                (Manager)


Applicant’s name ............................ :          Shenzhen Powerqi Technology Co., Ltd.
                                                         2nd Floor, A4 Building, Block A, Fangxing Science & Tech. Park,
Address............................................. :
                                                         Longgang District, Shenzhen, China
Testing Laboratory Name .............. :                 Shenzhen CTL Testing Technology Co., Ltd.
                                                         Floor 1-A, Baisha Technology Park, No. 3011, Shahexi Road,
Address............................................. :
                                                         Nanshan, Shenzhen 518055 China.
Test specification .......................... :
Standard ........................................... :   FCC CFR 47 part1, 1.1307(b), 1.1310
TRF Originator .................................. :      Shenzhen CTL Testing Technology Co., Ltd.
Master TRF ....................................... :     Dated 2011-01
Test item description .....................:             15W Fast Wireless Charger

FCC ID…………………………….…..:                                   2AFP2-FC16C

Trade Mark ....................................... :     POWERQI
Model/Type reference....................... :            FC16C

Transmit Frequency......................... :            115~205KHz
Antenna type .................................... :      Loop antenna
Date of receipt of test item ................. : Jun. 20, 2019
Date of sampling................................. : Jun. 20, 2019
Date of Test Date ............................... : Jun. 20, 2019–Jul. 02, 2019
Data of Issue ...................................... : Jul. 09, 2019
Result.................................................. : Pass
Shenzhen CTL Testing Technology Co., Ltd. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen CTL Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the
material. Shenzhen CTL Testing Technology Co., Ltd. takes no responsibility for and will not assume
liability for damages resulting from the reader's interpretation of the reproduced material due to its
placement and context.


V1.0                                 Page 2 of 9                Report No.: CTL1906131022-MPE



                                    TEST REPORT
                                                                                             Jul. 09, 2019
 Test Report No. :                 CTL1906131022-MPE                ________________________________________________________________________________________


                                                                                             Date of issue


   Equipment under Test     :    15W Fast Wireless Charger


   Type / Model(s)          :    FC16C


   Applicant                :    Shenzhen Powerqi Technology Co., Ltd.


   Address                  :    2nd Floor, A4 Building, Block A, Fangxing Science & Tech. Park,
                                 Longgang District, Shenzhen, China


   Manufacturer             :    Shenzhen Powerqi Technology Co., Ltd.


   Address                  :    2nd Floor, A4 Building, Block A, Fangxing Science & Tech. Park,
                                 Longgang District, Shenzhen, China




             Test Result                                         PASS


 The test results presented in this report relate only to the object tested.
 This report shall not be reproduced, except in full, without the written approval of the issuing testing
 laboratory.


 V1.0                                Page 3 of 9              Report No.: CTL1906131022-MPE


                                           Contents

1.      SUMMARY ............................................................................. 4

1.1.    EUT configuration                                                                      4

2.      TEST ENVIRONMENT............................................................... 4

2.1.    Address of the test laboratory                                                         4
2.2.    Test Facility                                                                          4
2.3.    Environmental conditions                                                               4
2.4.    Statement of the measurement uncertainty                                               5

3.      METHOD OF MEASUREMENT .................................................... 5

3.1.    Applicable Standard                                                                    5
3.2.    Limit                                                                                  5

4.      TEST RESULT ........................................................................ 6

4.1.    Test Setup                                                                             6
4.2.    Test Equipment                                                                         6

HI3637 .......................................................................................... 6

4.3.    Measurement Procedure                                                                  6
4.4.    Equipment Approval Considerations                                                      6
4.5.    E and H field Strength                                                                 7

5.      TEST SETUP PHOTO ............................................................... 8


 V1.0                                      Page 4 of 9                   Report No.: CTL1906131022-MPE



1. SUMMARY

1.1. EUT configuration
Kind of Product                                             15W Fast Wireless Charger
Model Name                                                  FC16C
Frequency Range                                             115-205KHz
Antenna Type                                                Loop Antenna
FCC ID                                                      2AFP2-FC16C

2. TEST ENVIRONMENT

2.1. Address of the test laboratory
Shenzhen CTL Testing Technology Co., Ltd.
Floor 1-A, Baisha Technology Park, No.3011, Shahexi Road, Nanshan District, Shenzhen, China 518055

The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.10 (2013) and
CISPR Publication 22.


2.2. Test Facility
The test facility is recognized, certified, or accredited by the following organizations:

CNAS-Lab Code: L7497
Shenzhen CTL Testing Technology Co., Ltd. has been assessed and proved to be in compliance with CNAS-
CL01 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC 17025: 2005
General Requirements) for the Competence of Testing and Calibration Laboratories.

A2LA-Lab Cert. No. 4343.01
Shenzhen CTL Testing Technology Co., Ltd, EMC Laboratory has been accredited by A2LA for technical
competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025: 2005
General Requirements for the Competence of Testing and Calibration Laboratories and any additional
program requirements in the identified field of testing.

IC Registration No.: 9518B

CAB identifier: CN0041
The 3m alternate test site of Shenzhen CTL Testing Technology Co., Ltd. EMC Laboratory has been
registered by Innovation, Science and Economic Development Canada to test to Canadian radio equipment
requirements with Registration No.: 9518B on Jan. 22, 2019.
FCC-Registration No.: 399832

Designation No.: CN1216
Shenzhen CTL Testing Technology Co., Ltd. EMC Laboratory has been registered and fully described in a
report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is
maintained in our files. Registration 399832, December 08, 2017.

2.3. Environmental conditions
During the measurement the environmental conditions were within the listed ranges:

  Temperature:                                  15-35 ° C

  Humidity:                                      30-60 %

  Atmospheric pressure:                      950-1050mbar


 V1.0                                    Page 5 of 9                 Report No.: CTL1906131022-MPE

2.4. Statement of the measurement uncertainty
Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the
apparatus:




3. Method of measurement
3.1. Applicable Standard
According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a
manner that ensures that the public is not exposed to radio frequency energy level in excess of the
Commission’s guidelines.
According to §1.1310 and §2.1091 RF exposure is calculated.
According KDB 680106 D01 RF Exposure Wireless Charging Pad App v03


3.2. Limit
Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure

   Frequency        Electric Field     Magnetic Field     Power Density       Averaging Time
  Range(MHz)        Strength(V/m)      Strength(A/m)        (mW/cm²)             (minute)
                        Limits for Occupational/Controlled Exposure
   0.3 – 3.0             614                1.63              (100) *                6
   3.0 – 30             1842/f             4.89/f            (900/f)*                6
   30 – 300              61.4              0.163                1.0                  6
  300 – 1500               /                  /                f/300                 6
1500 – 100,000             /                  /                  5                   6

Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure

   Frequency        Electric Field     Magnetic Field     Power Density       Averaging Time
  Range(MHz)        Strength(V/m)      Strength(A/m)        (mW/cm²)             (minute)
                        Limits for Occupational/Controlled Exposure
   0.3 – 3.0             614                1.63              (100) *               30
   3.0 – 30             824/f              2.19/f            (180/f)*               30
   30 – 300              27.5              0.073                0.2                 30
  300 – 1500               /                  /               f/1500                30
1500 – 100,000             /                  /                 1.0                 30

F=frequency in MHz
*=Plane-wave equivalent power density


 V1.0                                   Page 6 of 9                    Report No.: CTL1906131022-MPE


4. Test Result
4.1. Test Setup




Note: A, B, C, D, E, F for six surfaces of the product.


4.2. Test Equipment
Equipment         Manufacturer      Model                 Serial no.        Calibrated date   Calibrated until
E-Field Probe     HOLADAY           HI3637                00052130          2019.5.20         2020.5.19
H-Field Probe     HOLADAY           HI3637                00052130          2019.5.20         2020.5.19


4.3. Measurement Procedure
a) The RF exposure test was performed on 360 degree turn table in anechoic chamber.
b) The measurement probe was placed at test distance (10cm) which is between the edge of the charger
   and the geometric centre of probe.
c) The turn table was rotated 360d degree to search of highest strength.
d) The highest emission level was recorded and compared with limit as soon as measurement of each points
   (A, B, C, D, E) were completed.
e) The EUT were measured according to the dictates of KDB 680106 D01 RF Exposure Wireless Charging
   Pad App v03.


4.4. Equipment Approval Considerations
The EUT does comply with KDB 680106 D01 RF Exposure Wireless Charging Pad App v03.
   (1) Power transfer frequency is less than 1 MHz..
    (2) Output power from each primary coil is less than or equal to 15 watts.
    (3) The transfer system includes only single primary and secondary coils. This includes charging systems
   that may have multiple primary coils and clients that are able to detect and allow coupling only between
   individual pairs of coils.
    (4) Client device is placed directly in contact with the transmitter.
    (5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion).
    (6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface
   from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit.
   Remark: Meet all the above requirements.


 V1.0                                  Page 7 of 9                 Report No.: CTL1906131022-MPE


4.5. E and H field Strength
Test mode for wireless charger: Normal Operation (Charging mode)

E-Filed Strength at 15 cm from the edges surrounding the EUT
 Frequency
                  Test          Test        Test         Test           Limits
   Range
               Position A    Position B   Position C  Position D        (V/m)
   (MHz)
   0.134          1.46          1.37        1.30         1.34           614.0

E-Filed Strength at 20 cm from the top of the EUT (V/m)
 Frequency
                  Test        Limits
   Range
               Position E     (V/m)
   (MHz)
   0.134          0.93        614.0

H-Filed Strength at 15 cm from the edges surrounding the EUT
 Frequency
                  Test         Test         Test         Test           Limits
   Range
               Position A    Position B  Position C   Position D        (A/m)
   (MHz)
   0.134         0.281         0.262       0.274        0.261           1.63

H-Filed Strength at 20 cm from the top of the EUT (V/m)
 Frequency
                  Test        Limits
   Range
               Position E     (A/m)
   (MHz)
   0.134         0.182         1.63

Test mode for wireless charger: Normal Operation (No load mode)
E-Filed Strength at 15 cm from the edges surrounding the EUT
 Frequency
                   Test          Test          Test         Test        Limits
   Range
                Position A    Position B   Position C     Position D    (V/m)
   (MHz)
   0.134           0.43          0.41          0.35         0.36        614.0

E-Filed Strength at 20 cm from the top of the EUT (V/m)
 Frequency
                  Test        Limits
   Range
               Position E     (V/m)
   (MHz)
   0.134          0.18        614.0

H-Filed Strength at 15 cm from the edges surrounding the EUT
 Frequency
                  Test         Test         Test         Test           Limits
   Range
               Position A    Position B  Position C   Position D        (A/m)
   (MHz)
   0.134         0.092         0.083       0.094        0.086           1.63

H-Filed Strength at 20 cm from the top of the EUT (V/m)
 Frequency
                  Test        Limits
   Range
               Position E     (A/m)
   (MHz)
   0.134         0.053         1.63


V1.0                  Page 8 of 9   Report No.: CTL1906131022-MPE