RF Exposure Info

FCC ID: 2AFKNF316W

RF Exposure Info

Download: PDF
FCCID_4459277

                                SGS-CSTC Standards Technical Services Co., Ltd.
                                Shenzhen Branch




                                                                   Report No.: SZEM190801754402
                                                                   Page:       1 of 9


1     COVER PAGE

                      Human Exposure Report
Application No.:               SZEM1908017544CR
Applicant:                     Spigen Korea Co., Ltd.
Address of Applicant:          Spigen HQ-A, 446, Bongeunsa-ro, Gangnam-gu, Seoul, 06153, South Korea
Manufacturer:                  Spigen Korea Co., Ltd.
Address of Manufacturer:       446, Bongeunsa-ro, Gangnam-gu, Seoul, 06153, South Korea.
Factory:                       ShenZhen Fangxin Technology Co., Ltd.
Address of Factory:            Rm 503, 5F, Hengbo Innovation Science and Technology Park, No.33,
                               Qingning Rd, Longhua St, Longhua Dist, Shenzhen, China
Equipment Under Test (EUT):
EUT Name:                 Flex Wireless Charger
Model No.:                F316W
Trade mark:                    Spigen, Steadiboost
FCC ID:                        2AFKNF316W
Standards:                     47 CFR PART 1, Subpart I, Section 1.1310
Date of Receipt:               2019-08-15
Date of Test:                  2019-08-17 to 2019-08-20
Date of Issue:                 2019-08-26
Test Result :                   Pass*
* In the configuration tested, the EUT complied with the standards specified above




             Keny Xu
      EMC Laboratory Manager


                           SGS-CSTC Standards Technical Services Co., Ltd.
                           Shenzhen Branch
                                                          Report No.: SZEM190801754402
                                                          Page:       2 of 9




                                       Revision Record
    Version        Chapter              Date                 Modifier       Remark

     01                              2019-08-26                             Original




Authorized for issue by:




                             Damon Su /Project Engineer




                             Eric Fu /Reviewer


                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                             Shenzhen Branch
                                                                                                 Report No.: SZEM190801754402
                                                                                                 Page:       3 of 9




2         Contents


1      COVER PAGE ..................................................................................................................................... 1

2      CONTENTS ......................................................................................................................................... 3

3      GENERAL INFORMATION .................................................................................................................. 4
    3.1    DETAILS OF E.U.T. ............................................................................................................................. 4
    3.2    DESCRIPTION OF SUPPORT UNITS ........................................................................................................ 4
    3.3    TEST LOCATION ................................................................................................................................. 5
    3.4    TEST FACILITY.................................................................................................................................... 5
    3.5    DEVIATION FROM STANDARDS .............................................................................................................. 5
    3.6    ABNORMALITIES FROM STANDARD CONDITIONS...................................................................................... 5
4      EQUIPMENTS USED DURING TEST .................................................................................................. 6

5      TEST RESULTS .................................................................................................................................. 7
    5.1 RF EXPOSURE TEST ........................................................................................................................... 7
       5.1.1 E.U.T. Operation ...................................................................................................................... 7
       5.1.2 Measurement Data .................................................................................................................. 8
6      PHOTOGRAPHS ................................................................................................................................. 9
    6.1 TEST SETUP PHOTOS .......................................................................................................................... 9


                           SGS-CSTC Standards Technical Services Co., Ltd.
                           Shenzhen Branch
                                                            Report No.: SZEM190801754402
                                                            Page:       4 of 9




3   General Information
3.1 Details of E.U.T.
    Power supply:          Input: DC5V, 3A or 9V, 2A or 12V, 1.5A,
                           Output: 5W/7.5W/10W/15W
                           Adapter Model: TY0U01QC
                           Input: AC 100-240V, 50/60Hz 0.8A
                           Output: DC (3.6V-6.5V), 3A or (6.5V-9V), 2A or (9V-12V), 1.5A
    Cable:                 USB Cable(Unshielded, 120cm)
    Operation Frequency:   113.30kHz to 137.66kHz
    Modulation Type:       Load Modulation
    Antenna Type:          Loop Antenna
    Remark:                This device has been tested the worst status of intermediate load and
                           horizontal placement, vertical placement had been tested and only the
                           worst vertical placement had been recorded in the report. The device has
                           been tested with mobile phone at zero charge, intermediate charge, and
                           full charge.



3.2 Description of Support Units

    Description                Manufacturer                Model No.               Serial No.
    Smart charger                   Toye                  TY0U01QC                    N/A
    iPhone 8                       Apple                      A1863             F4GVQ656JC6D
    Mobile Phone                SAMSUNG                    SM-G9500              R28J9140LPB


                              SGS-CSTC Standards Technical Services Co., Ltd.
                              Shenzhen Branch
                                                               Report No.: SZEM190801754402
                                                               Page:       5 of 9




3.3 Test Location
     All tests were performed at:
     SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Branch E&E Lab,
     No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong,China
     518057.
     Tel: +86 755 2601 2053         Fax: +86 755 2671 0594
     No tests were sub-contracted.

3.4 Test Facility
    The test facility is recognized, certified, or accredited by the following organizations:
    • CNAS (No. CNAS L2929)
    CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
    Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
    Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
    Laboratories) for the competence in the field of testing.
    • A2LA (Certificate No. 3816.01)
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
    American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
    • VCCI
    The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz,
    Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
    Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have
    been registered in accordance with the Regulations for Voluntary Control Measures with Registration
    No.: G-20026, R-14188, C-12383 and T-11153 respectively.
    • FCC –Designation Number: CN1178
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    as an accredited testing laboratory.
    Designation Number: CN1178. Test Firm Registration Number: 406779.
    • Innovation, Science and Economic Development Canada
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    by ISED as an accredited testing laboratory.
    CAB identifier: CN0006.
    IC#: 4620C.

3.5 Deviation from Standards
    None.

3.6 Abnormalities from Standard Conditions
    None.


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Shenzhen Branch
                                                             Report No.: SZEM190801754402
                                                             Page:       6 of 9




4      Equipments Used during Test


Item       Equipment          Manufacturer    Model No   Inventory No    Cal Date    Cal Due Date

                              WANDEL      &
       Electric Field Probe
 1                            GOLTERMAN       EMR-20     EMC0907        2019-05-21   2020-05-20
       (100KHz-3GHz)
                              N
 2     EMF Tester             Narda           ELT-400    SZE039-4       2019-07-08   2020-07-07


                                  SGS-CSTC Standards Technical Services Co., Ltd.
                                  Shenzhen Branch
                                                                       Report No.: SZEM190801754402
                                                                       Page:       7 of 9




5       Test Results
5.1 RF Exposure test
        Test Requirement:                 47 CFR PART 1, Subpart I, Section 1.1310
        Measurement Distance:             15cm
        Limit:

    Frequency range Electric field strength Magnetic field strength Power density Averaging time
         (MHz)               (V/m)                  (A/m)             (mW/cm2)      (minutes)
                              (A) Limits for Occupational/Controlled Exposures
           0.3-3.0                614                        1.63               *(100)            6
           3.0-30                1842/f                      4.89/f            *(900/f 2)         6
           30-300                 61.4                       0.163                1.0             6
          300-1500                    /                        /                 f/300            6
        1500-100,000                  /                        /                     5            6
                          (B) Limits for General Population/Uncontrolled Exposure
          0.3-1.34                614                        1.63               *(100)           30
           1.34-30                824/f                      2.19/f            *(180/f 2)        30
           30-300                 27.5                       0.073                0.2            30
          300-1500                    /                        /                f/1500           30
        1500-100,000                  /                        /                  1.0            30
    F=frequency in MHz
    *=Plane-wave equivalent power density
    RF exposure compliance will need to be determined with respect to 1.1307(c) and (d) of the FCC
    rules. The emissions should be within the limits at 300kHz in Table 1 of 1.1310(use the 300kHz limits
    for 150kHz:614V/m,1.63A/m).
5.1.1     E.U.T. Operation
        Operating Environment:
        Temperature:        24.0 °C           Humidity:   52 % RH         Atmospheric Pressure: 1015 mbar
        EUT Operation:
        This device has been tested with mobile phone at zero charge, intermediate charge, and full
         charge.


                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                 Shenzhen Branch
                                                                 Report No.: SZEM190801754402
                                                                 Page:       8 of 9



5.1.2   Measurement Data

All three load modes were conducted and the worst case(10W) is reported only.


        Mobile phone has been charge at zero charge, intermediate charge, and full charge.

        Electric Field Emissions

         Operation        Test                       Probe Measure Result(V/m)
                                        Test                                             50%Limit
         frequency      Distance
                                      Position     zero      intermediate         full
                                                  charge        charge          charge    (V/m)
                           (cm)
                                        Side 1      2.13          1.91           1.66      307
                                        Side 2      3.78          3.58           3.37      307
          114 kHz           15          Side 3      1.7           1.39           1.21      307
                                        Side 4      1.22          0.99           0.77      307
                                         Top        0.83          0.62           0.44      307


        Magnetic Field Emissions

         Operation        Test                       Probe Measure Result(A/m)
                                        Test                                             50%Limit
         frequency      Distance
                                      Position    zero       intermediate       full
                                                  charge        charge          charge    (A/m)
                           (cm)
                                        Side 1    0.1507        0.1384          0.1239    0.815
                                        Side 2    0.2598        0.2491          0.2343    0.815
          114 kHz           15          Side 3    0.1291        0.1183          0.1045    0.815
                                        Side 4    0.0975        0.0874          0.0739    0.815
                                         Top      0.0527        0.0421          0.0292    0.815


                              SGS-CSTC Standards Technical Services Co., Ltd.
                              Shenzhen Branch
                                                             Report No.: SZEM190801754402
                                                             Page:       9 of 9




6     Photographs
6.1       Test setup photos




      .


                                     - End of the Report -



Document Created: 2019-09-19 13:50:21
Document Modified: 2019-09-19 13:50:21

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC