                   Justification for WPT RF Exposure Evaluation Consideration

FCC ID: 2AFKNF316W

Dear Examiner,
There’s a WPT device as below we’d like to be authorized per KDB 680106 D01.

 Company:               Spigen Korea Co., Ltd.
 Model Number:          F316W


As addressed in KDB 680106 D01 RF Exposure Wireless Charging App v03section 5, Inductive wireless power
transfer applications with supporting field strength results and meeting all the 6 following requirements are not
required to submit a KDB inquiry for a PAG for equipment approved using certification to address RF exposure
compliance.
Here is a briefing about the device.

 KDB 680106 D01 Section 5 Requirements:                        Justification
 1) Power transfer frequency is less that 1 MHz                Yes, 113.30kHz to 137.66kHz
 2) Output power from each primary coil is less than or        Yes, 15W Max.
 equal to 15 watts.
 3) The transfer system includes only single primary and       Yes, includes only single primary
 secondary coils. This includes charging systems that may      and secondary coils.
 have multiple primary coils and clients that are able to
 detect and allow coupling only between individual pairs
 of coils.
 4) Client device is placed directly in contact with the       Yes
 transmitter.
 5) Mobile exposure conditions only (portable exposure         Yes, for desktop application,
 conditions are not covered by this exclusion).                it’s mobile condition.
 6) The aggregate H-field strengths at 15 cm surrounding       Yes
 the device and 20 cm above the top surface from all           The strengths at 15cm
 simultaneous transmitting coils are demonstrated to be        surrounding the device are
 less than 50% of the MPE limit.                               demonstrated to be less than 50%
                                                               of the MPE limit.

Sincerely,
Signed By: Jing Song




On behalf of SGS-CSTC Standards Technical Services Co., Ltd.
Shenzhen Branch under written authorization from Grantee
Email: jing.song@sgs.com
Date: 2019/09/18





Document Created: 2019-09-23 18:12:29
Document Modified: 2019-09-23 18:12:29

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC