Test report

FCC ID: 2AFJI20181198

Test Report

Download: PDF
FCCID_4065177

                             Global United Technology Services Co., Ltd.
                                                                                   Report No.: GTS201808000194F06



                              TEST REPORT
 Applicant:                            Quantum Creations LLC.

 Address of Applicant:                 15705 NW 13th Ave, Miami Gardens, Miami Beach, Florida
                                       33169, United States
 Manufacturer/Factory:                 MELE TECHNOLOGIES(SHENZHEN) CO.,LTD

 Address of              1F, Bldg#2, 28 Cuijing Road, Pingshan District, Shenzhen, PR
 Manufacturer/Factory:   China.
 Equipment Under Test (EUT)

   Product Name:                       Access 3

   Model No.:                          A-1198-AA3, A-1198-AA3-1, A-1198-AA3-2, A-1198-AA3-3, A-
                                       1198-AA3-4, A-1198-AA3-5, A-1198-AA3-6, A-1198-AA3-7, A-
                                       1198-AA3-8, A-1198-AA3-9
   Trade Mark:                         AZULLE

 FCC ID:                               2AFJI20181198

 Applicable standards:                 FCC CFR Title 47 Part 15 Subpart B

 Date of sample receipt:               August 28, 2018

 Date of Test:                         August 28-September 07, 2018

 Date of report issued:                September 07, 2018

 Test Result :                         PASS *

* In the configuration tested, the EUT complied with the standards specified above.




  Authorized Signature:




    Robinson Lo
 Laboratory Manager
 This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in
 full, without prior written permission of the company. The report would be invalid without specific stamp of test institute
 and the signatures of compiler and approver.


                                                                               Report No.: GTS201808000194F06


2      Version
      Version No.                         Date                                    Description
           00                    September 07, 2018                                 Original




Prepared By:                                                       Date:              September 07, 2018

                                     Project Engineer



Check By:                                                          Date:              September 07, 2018

                                          Reviewer




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                               Page 2 of 19


                                                                                                            Report No.: GTS201808000194F06

3         Contents
1     COVER PAGE ........................................................................................................................................... 1

2     VERSION .................................................................................................................................................. 2

3     CONTENTS .............................................................................................................................................. 3

4     TEST SUMMARY ..................................................................................................................................... 4

5     GENERAL INFORMATION ...................................................................................................................... 5
    5.1       GENERAL DESCRIPTION OF EUT ......................................................................................................... 5
    5.2       TEST MODE AND TEST VOLTAGE .......................................................................................................... 5
    5.3       DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 6
    5.4       DEVIATION FROM STANDARDS ............................................................................................................. 6
    5.5       ABNORMALITIES FROM STANDARD CONDITIONS .................................................................................... 6
    5.6       TEST FACILITY .................................................................................................................................... 6
    5.7       TEST LOCATION .................................................................................................................................. 6
6     TEST INSTRUMENTS LIST ..................................................................................................................... 7

7     TEST RESULTS AND MEASUREMENT DATA...................................................................................... 9
    7.1       RADIATED EMISSION ........................................................................................................................... 9
    7.2       CONDUCTED EMISSIONS ................................................................................................................... 15
8     TEST SETUP PHOTO ............................................................................................................................ 18

9     EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 19




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                                                    Page 3 of 19


                                                                               Report No.: GTS201808000194F06

4      Test Summary
       Test Item                Test Requirement                Test Method       Class / Severity       Result
Conducted Emission                FCC Part15.107                 ANSI C63.4           Class B            PASS
Radiated Emissions #              FCC Part15.109                 ANSI C63.4           Class B            PASS
Remark:
1.   Pass: The EUT complies with the essential requirements in the standard.
2.   # Refer to FCC Part 15.33 (b)(1) conditional testing procedure :
The highest frequency generated or used in the EUT          Test frequency range of Radiated emission
<108MHz                                                     30MHz ~ 1GHz
108MHz ~ 500MHz                                             30MHz ~ 2GHz
500MHz ~ 1GHz                                               30MHz ~ 5GHz
>1GHz                                                       30MHz ~ 5th harmonic of the highest frequency or 40
                                                            GHz, whichever is lower.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                               Page 4 of 19


                                                                               Report No.: GTS201808000194F06

5      General Information
5.1 General Description of EUT
      Product Name:                   Access 3
      Model No.:                      A-1198-AA3, A-1198-AA3-1, A-1198-AA3-2, A-1198-AA3-3,
                                      A-1198-AA3-4, A-1198-AA3-5, A-1198-AA3-6, A-1198-AA3-7,
                                      A-1198-AA3-8, A-1198-AA3-9
      Test Model No:                  A-1198-AA3
      Serial No.:                     000001
      Hardware version:               V1.1
      Software version:               V1.1
      Test sample(s) ID:              GTS201808000194-2
      Sample(s) Status                Normal sample
      Power supply:                   SWITCHING ADAPTOR
                                      Model No.: FJ-SW0503000N
                                      Input: AC 100-240V, 50/60Hz, 0.6A Max
                                      Output: DC 5V, 3000mA

5.2 Test mode and Test voltage
      Test mode:
      Burning test mode               Keep the EUT in full load and burning test status.
      Test voltage
      AC120V 60Hz




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                Page 5 of 19


                                                                               Report No.: GTS201808000194F06
5.3 Description of Support Units
      Manufacturer                   Description                       Model               Serial Number
          DELL                       KEYBOARD                        SK-8115                  GTS237-2
          DELL                         MOUSE                         MOC5UO                   GTS237-3
         SanDisk                       USB disk                        16GB                      N/A
         PHILIPS                     LCD monitor                  19PFL3120/T3            AU1A1212002906

5.4 Deviation from Standards
      None.

5.5 Abnormalities from Standard Conditions
      None.

5.6 Test Facility
      The test facility is recognized, certified, or accredited by the following organizations:
      ● FCC —Registration No.: 381383
      Global United Technology Services Co., Ltd., Shenzhen EMC Laboratory has been registered and fully
      described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter
      from the FCC is maintained in files. Registration 381383, January 08, 2018.
      ● Industry Canada (IC) —Registration No.: 9079A-2
      The 3m Semi-anechoic chamber of Global United Technology Services Co., Ltd. has been
      registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing
      with Registration No.: 9079A-2, August 15, 2016

5.7 Test Location
      The test was performed at:
      Global United Technology Services Co., Ltd.
      Address: No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road,
      Baoan District, Shenzhen, Guangdong, China 518102
      Tel: 0755-27798480
      Fax: 0755-27798960




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 6 of 19


                                                                                Report No.: GTS201808000194F06

6        Test Instruments list
Radiated Emission:
                                                                               Inventory     Cal.Date        Cal.Due date
Item       Test Equipment          Manufacturer            Model No.
                                                                                  No.       (mm-dd-yy)       (mm-dd-yy)
         3m Semi- Anechoic
 1                               ZhongYu Electron    9.2(L)*6.2(W)* 6.4(H)     GTS250      July. 03 2015     July. 02 2020
             Chamber
 2          Control Room         ZhongYu Electron    6.2(L)*2.5(W)* 2.4(H)     GTS251          N/A               N/A
 3        EMI Test Receiver      Rohde & Schwarz            ESU26              GTS203      June. 27 2018     June. 26 2019
                                 SCHWARZBECK
 4       BiConiLog Antenna                                VULB9163             GTS214      June. 27 2018     June. 26 2019
                                MESS-ELEKTRONIK
       Double -ridged waveguide SCHWARZBECK
 5                                                        9120D-829            GTS208      June. 27 2018     June. 26 2019
                  horn         MESS-ELEKTRONIK
 6          Horn Antenna         ETS-LINDGREN                3160              GTS217      June. 27 2018     June. 26 2019
 7        EMI Test Software          AUDIX                    E3                 N/A           N/A               N/A
 8          Coaxial Cable              GTS                    N/A              GTS213      June. 27 2018     June. 26 2019
 9          Coaxial Cable              GTS                    N/A              GTS211      June. 27 2018     June. 26 2019
10          Coaxial cable              GTS                    N/A              GTS210      June. 27 2018     June. 26 2019
11          Coaxial Cable              GTS                    N/A              GTS212      June. 27 2018     June. 26 2019
12     Amplifier(100kHz-3GHz)          HP                   8347A              GTS204      June. 27 2018     June. 26 2019
13     Amplifier(2GHz-20GHz)           HP                   8349B              GTS206      June. 27 2018     June. 26 2019
                                                         AFS33-18002
14      Amplifier (18-26GHz)     Rohde & Schwarz                               GTS218      June. 27 2018     June. 26 2019
                                                         650-30-8P-44
15           Band filter            Amindeon                 82346             GTS219      June. 27 2018     June. 26 2019
16          Power Meter              Anritsu               ML2495A             GTS540      June. 27 2018     June. 26 2019
17          Power Sensor             Anritsu               MA2411B             GTS541      June. 27 2018     June. 26 2019
          Wideband Radio
18                               Rohde & Schwarz           CMW500              GTS588      June. 27 2018     June. 26 2019
        Communication Tester
19             Splitter              Agilent                11636B             GTS237      June. 27 2018     June. 26 2019
20          Loop Antenna             ZHINAN               ZN30900A             GTS534      June 28 2017      June 27 2018




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                   Page 7 of 19


                                                                                Report No.: GTS201808000194F06

 Conducted Emission
                                                                                Inventory    Cal.Date        Cal.Due date
  Item        Test Equipment        Manufacturer             Model No.
                                                                                   No.      (mm-dd-yy)        (mm-dd-yy)
     1        Shielding Room      ZhongYu Electron     7.3(L)x3.1(W)x2.9(H)     GTS252     May.16 2014       May.15 2019
     2       EMI Test Receiver          R&S                   ESCI 7            GTS552    June. 27 2018     June. 26 2019
     3        Coaxial Switch      ANRITSU CORP                MP59B             GTS225    June. 27 2018     June. 26 2019
              Artificial Mains    SCHWARZBECK
     4                                                       NSLK8127           GTS226      June. 27 2018   June. 26 2019
                  Network              MESS
     5         Coaxial Cable            GTS                     N/A             GTS227           N/A             N/A
     6       EMI Test Software         AUDIX                    E3               N/A             N/A             N/A
     7         Thermo meter             KTJ                    TA328            GTS233      June. 27 2018   June. 26 2019
                                     Elektronik-
     8       Absorbing clamp                                  MDS21             GTS229      June. 27 2018   June. 26 2019
                                   Feinmechanik

 General used equipment:

                                                                                Inventory      Cal.Date      Cal.Due date
Item      Test Equipment          Manufacturer               Model No.
                                                                                   No.        (mm-dd-yy)     (mm-dd-yy)

       Humidity/ Temperature
 1                                  Shanghai                  ZJ1-2B            GTS243      June. 27 2018   June. 26 2019
             Indicator

 2          Barometer             ChangChun                   DYM3              GTS255      June. 27 2018   June. 26 2019




 Global United Technology Services Co., Ltd.
 No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
 Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                 Page 8 of 19


                                                                               Report No.: GTS201808000194F06

7      Test Results and Measurement Data
7.1 Radiated Emission
      Test Requirement:                FCC Part15 B Section 15.109
      Test Method:                     ANSI C63.4:2014
      Test Frequency Range:            30MHz to 6GHz
      Test site:                       Measurement Distance: 3m (Semi-Anechoic Chamber)
      Receiver setup:                    Frequency      Detector     RBW        VBW        Remark
                                          30MHz-      Quasi-peak    120kHz     300kHz Quasi-peak Value
                                           1GHz
                                                         Peak        1MHz       3MHz     Peak Value
                                        Above 1GHz
                                                         Peak        1MHz       10Hz    Average Value
      Limit:                                  Frequency           Limit (dBuV/m @3m)       Remark
                                              30MHz-88MHz                      40.00          Quasi-peak Value
                                             88MHz-216MHz                      43.50          Quasi-peak Value
                                             216MHz-960MHz                     46.00          Quasi-peak Value
                                              960MHz-1GHz                      54.00          Quasi-peak Value
                                                                               54.00           Average Value
                                               Above 1GHz
                                                                               74.00             Peak Value
      Test setup:                      For radiated emissions from 30MHz to1GHz




                                       For radiated emissions above 1GHz




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 9 of 19


                                                                               Report No.: GTS201808000194F06




      Test Procedure:                  1. The EUT was placed on the top of a rotating table 0.8 meters above
                                          the ground at a 3 meter semi-anechoic chamber. The table was
                                          rotated 360 degrees to determine the position of the highest
                                          radiation.
                                       2. The EUT was set 3 meters away from the interference-receiving
                                          antenna, which was mounted on the top of a variable-height antenna
                                          tower.
                                       3. The antenna height is varied from one meter to four meters above
                                          the ground to determine the maximum value of the field strength.
                                          Both horizontal and vertical polarizations of the antenna are set to
                                          make the measurement.
                                       4. For each suspected emission, the EUT was arranged to its worst
                                          case and then the antenna was tuned to heights from 1 meter to 4
                                          meters and the rotatable table was turned from 0 degrees to 360
                                          degrees to find the maximum reading.
                                       5. The test-receiver system was set to Peak Detect Function and
                                          Specified Bandwidth with Maximum Hold Mode.
                                       6. If the emission level of the EUT in peak mode was 10dB lower than
                                          the limit specified, then testing could be stopped and the peak
                                          values of the EUT would be reported. Otherwise the emissions that
                                          did not have 10dB margin would be re-tested one by one using
                                          peak, quasi-peak or average method as specified and then reported
                                          in a data sheet.
      Test environment:                Temp.:         25 °C      Humid.:      52%      Press.:     1 012mbar
      Measurement Record:                                                               Uncertainty: ± 4.50dB
      Test Instruments:                Refer to section 6 for details
      Test mode:                       Refer to section 5.2 for details.
      Test results:                    Pass




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 10 of 19


                                                                                 Report No.: GTS201808000194F06

Measurement Data

Below 1GHz
Test mode:              Burning test mode                    Antenna Polarity:              Horizontal




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                               Page 11 of 19


                                                                                 Report No.: GTS201808000194F06

Test mode:                 Burning test mode                 Antenna Polarity:              Vertical




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                               Page 12 of 19


                                                                                 Report No.: GTS201808000194F06
Above 1GHz

Test mode:                 Burning test mode                 Antenna Polarity:              Horizontal




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                               Page 13 of 19


                                                                                 Report No.: GTS201808000194F06

Test mode:                 Burning test mode                 Antenna Polarity:              Vertical




Note:
The field strength is calculated by adding the Antenna Factor, Cable Factor & Preamplifier. The basic
equation with a sample calculation is as follows:
Final Test Level =Receiver Reading + Antenna Factor + Cable Factor – Preamplifier Factor




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                               Page 14 of 19


 GTS
                                                                                          Report No.: GTS201808000194F06


7.2 Conducted Emissions
      Test Requirement:                FCC Part15 B Section 15.107
      Test Method:                     ANSI C63.4:2014
      Test Frequency Range:            150kHz to 3OMHz
      Class / Severity:                Class B
      Receiver setup:                  RBW=9kHz, VBW=30kHz

      Limit:                                                                                       Limit (dBuV)
                                            Frequency range (MHz)                       Guasi—peak                Average

                                                     0.15—0.5                            66 to 56*                56 to 46*
                                                       0.5—5                                56                       46
                                                      0.5—30                                60                       50
      Test setup:                                               Reference Plane
                                              LIsN                                        [LisN
                                                                40cm         80cm

                                            AuX                                                m            AC power
                                            Equipment              E.UVU.T
                                                                                        EMI
                                                                                        Receiver
                                             Test table/Insulation plane


                                        Remark
                                        EUTEquipment Linder Test
                                        LiSN Line Impedence Stabiltzetion Network
                                        Test table height=0.8m

      Test procedure                   1.    The E.U.T and simulators are connected to the main power through
                                             a line impedance stabilization network(L.1.S.N.). The provide a
                                             50ohm/50uH coupling impedance for the measuring equipment.
                                       2.     The peripheral devices are also connected to the main power
                                             through a LISN that provides a 50ohm/50uH coupling impedance
                                             with 50ohm termination. (Please refers to the block diagram of the
                                             test setup and photographs).
                                       3.    Both sides of A.C. line are checked for maximum conducted
                                             interference. In order to find the maximum emission, the relative
                                             positions of equipment and all of the interface cables must be
                                             changed according to ANSI €63.4: 2014 on conducted
                                             measurement.
      Test environment:                Temp.:        [ 25 °C         | Humid.:      |    52%         | Press.:    | 1 012mbar
      Test Instruments:                Refer to section 6 for details
      Test mode:                       Refer to section 5.2 for details.
      Test results:                    Pass




Global United Technology Services Co., Ltd.
No. 301—309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Bacan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                            Page 15 of 19


                                                                               Report No.: GTS201808000194F06

Measurement Data
Test mode:                   Burning test mode             Phase Polarity:              Line




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 16 of 19


                                                                               Report No.: GTS201808000194F06

Test mode:                   Burning test mode             Phase Polarity:              Neutral




Notes:
1. The following Quasi-Peak and Average measurements were performed on the EUT:
2. Final Test Level =Receiver Reading + LISN Factor + Cable Loss.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 17 of 19


                                                                               Report No.: GTS201808000194F06

8      Test Setup Photo
      Radiated Emission




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 18 of 19


                                                                               Report No.: GTS201808000194F06

      Conducted Emission




9      EUT Constructional Details
Reference to the test report No. : GTS201808000194F01



                                                    ------End------




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 19 of 19



Document Created: 2019-04-18 10:02:44
Document Modified: 2019-04-18 10:02:44

© 2024 FCC.report