RF_Exposure2AFIH-BND106

FCC ID: 2AFIH-BND106

RF Exposure Info

Download: PDF
FCCID_4067806

                             Shenzhen Toby Technology Co., Ltd.
                                                                        Report No.: TB-MPE162345
                                                                        Page:       1 of 5

                          RF Exposure Evaluation
                               FCC ID: 2AFIH-BND106
  1. Client Information
 Applicant         : Brand New Days Limited
                       Unit B, 6/F Tong Yuen Factory Building, 505 Castle Peak Road, Lai
 Address           :
                       Chi Kok, Kowloon, Hong Kong
 Manufacturer      : Shenzhen Casun Technologies Co., Ltd.
                       4/F, B Building, No.8 Eastern Zone, Shangxue Technology Park,
 Address           :
                       Bantian, Shenzhen, China

  2. General Description of EUT
  EUT Name                : Wireless Charger
  Models No.              : BND106
  Model Difference        : N/A
                             Operation Frequency:          110KHz-205KHz
  Product
                          : Modulation Type:               MSK
  Description
                            Antenna:                       Coil Antenna
  Power Supply            : Input: 5V/2A
                            Output: 5V/1A
  Charging Distance       : ≤8mm

  Software Version        : N/A
  Hardware Version        : N/A
  Connecting I/O          : Please refer to the User's Manual
  Port(S)

Note: More test information about the EUT please refer the RF Test Report.




                                                                                             TB-RF-074-1.0

          1A/F., Bldg.6, Yusheng Industrial Zone, The National Road No.107 Xixiang Section 467, Xixiang,
                                     Bao’an, Shenzhen, China
                                 Tel: +86 75526509301       Fax: +86 75526509195


                                                                           Report No.: TB-MPE162345
                                                                           Page:       2 of 5




                              RF Exposure Considerations
1. Measuring Standard
   KDB 680106 D01 RF Exposure Wireless Charging App v03.
2. Requirements
   According to the item 5.2 of KDB 680106 D01v03:
   Inductive wireless power transfer applications that meet all of the following requirements
   are excluded from submitting an RF exposure evaluation:
   (1) Power transfer frequency is less than 1 MHz.
   (2) Output power from each primary coil is less than or equal to 15 watts.
   (3) The transfer system includes only single primary and secondary coils. This includes
   charging systems that may have multiple primary coils and clients that are able to detect
   and allow coupling only between individual pairs of coils.
   (4) Client device is placed directly in contact with the transmitter.
   (5) Mobile exposure conditions only (portable exposure conditions are not covered by this
   exclusion).
   (6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the
   top surface from all simultaneous transmitting coils are demonstrated to be less than 50%
   of the MPE limit.

                        Limits For Maximum Permissible Exposure (MPE)




                                                                                      TB-RF-074-1.0


                                                                         Report No.: TB-MPE162345
                                                                         Page:       3 of 5


3. Test Setup




                                                15cm




Note: The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top
surface.

4.Test Procedure
     1) The RF exposure test was performed in anechoic chamber.
     2) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the
     top surface.
     3) The highest emission level was recorded and compared with limit as soon as
     measurement of each points (A, B, C, D, E) were completed.
     4) The EUT was measured according to the dictates of KDB 680106 D01 v03.
     Remark:
     The EUT’s test position A, B, C, D and E is valid for the E and H field measurements.

5. Test Equipment List

                                                                                            Cal. Due
   Equipment           Manufacturer      Model No.         Serial No.      Last Cal.
                                                                                             Date
Magnetic field meter      NARDA           ELT-400            EE030       Sep. 27, 2018    Sep. 26, 2019




                                                                                         TB-RF-074-1.0


                                                                                                                               Report No.: TB-MPE162345
                                                                                                                               Page:       4 of 5


6. Test Result

Test Mode: Output 5V/1A
                                                                               E-Filed Strength
 Frequency                                       Test                                                                         50% Limits   Limits
                       Test                                           Calculated Value                     Calculated Value
   Range                                       Distance                                                                          Test       Test    Result
                      Position                                             (A/m)                                 (V/m)          (V/m)
   (KHz)                                        (cm)                                                                                       (V/m)
                            A                     15                           0.118                               44.499                           PASS
                            B                       15                         0.114                               42.695                           PASS
  110-205                   C                       15                         0.109                               40.891        307        614     PASS
                            D                       15                         0.134                               50.513                           PASS
                            E                       20                         0.142                               53.219                           PASS

                                                                               H-Filed Strength
 Frequency                                       Test                                                                         50% Limits   Limits
                       Test                                            Measured Value                      Calculated Value
   Range                                       Distance                                                                          Test       Test    Result
                      Position                                             (uT)                                  (A/m)          (A/m)
   (KHz)                                        (cm)                                                                                       (A/m)
                            A                       15                         0.148                                0.118                           PASS
                            B                       15                         0.142                                0.114                           PASS
  110-205                   C                       15                         0.136                                0.109       0.815       1.63    PASS
                  D              15               0.168               0.134                                                                         PASS
                  E              20               0.177               0.142                                                                         PASS
Note: The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface.
          ((( dBuV / m ) 120)/20)          ((( dBuA / m 51.5) 120)/20)          (((20lg( A / m*106 )  51.5) 120)/ 20)
V/m= 10                              = 10                                   = 10
      A/m=uT/1.25




                                                                                                                                             TB-RF-074-1.0


                                                 Report No.: TB-MPE162345
                                                 Page:       5 of 5


7. Test Set-up Photo
                         Test Set-up Photo




                       -----END OF REPORT-----




                                                            TB-RF-074-1.0



Document Created: 2018-11-05 15:55:19
Document Modified: 2018-11-05 15:55:19

© 2024 FCC.report