RF Exposure information

FCC ID: 2AFHW-VTA75

RF Exposure Info

Download: PDF
FCCID_4201832

                                                   RF exposure Estimation

1.        Introduction

          Product: 5-in-1 Turntable
          Model no.: VTA-75
          FCC ID: 2AFHW-VTA75
          The EUT is 5-in-1 Turntable, which contain Bluetooth function inside.

2.        Limit and Guidelines on Exposure to Electromagnetic Fields
          According to§15.247(e)(i) and §1.1307(b)(1), systems operating under the provisions of this
          section shall be operated in a manner that ensure that the public is not exposed to radio
          frequency energy level in excess of the Commission’s guideline.

          According to KDB 447498 D01 Mobile Portable RF Exposure v05r01, no SAR required if power
          is lower than the flowing threshold:
          The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation
          distances ≤ 50 mm are determined by:
           [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]
           [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where
               • f(GHz) is the RF channel transmit frequency in GHz
               • Power and distance are rounded to the nearest mW and mm before calculation25
               • The result is rounded to one decimal place for comparison
               • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below

          The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm
          and for transmission frequencies between 100 MHz and 6 GHz.

3.        Calculation method

          [(max. power of` channel, including tune-up tolerance, mW)/(min. test separation distance,
          mm)] ·[√f(GHz)] ≤ 3.0

          Conducted Power + tune up tolerance =4.08dBm= 2.56mW
          Distance = 5 mm
          f = 2.402 GHz

          [2.56/5] * SQRT (2.402) =0.7935
          0.7935≤ 3.0

          Therefore, excluded from SAR testing.

- TÜV SÜD Shenzhen LTD. -
Reviewed by:                                                                         Prepared By:




Phoebe Hu/EMC Department Manager                                                      Mark Chen/EMC Project Engineer
Date: 2018-12-13                                                                      Date: 2018-12-13

                                         TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China
                                                   Tel. +86 755 8828 6998, Fax: +86 755 8828 5299



Document Created: 2019-03-26 11:55:59
Document Modified: 2019-03-26 11:55:59

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC