RF Exposure Report

FCC ID: 2AFHW-VTA320B

RF Exposure Info

Download: PDF
FCCID_4353408

                    Test Report No.: FM190304N022


                                   RF EXPOSURE REPORT
   Applicant                       Innovative Technology Electronics, LLC


   Address                         1 Channel Drive, Port Washington, NY 11050, USA


   Manufacturer or
                                   Guangdong Leetac Electronics Technology Co .,Ltd.
   Supplier

   Address                         No.15 Danli Road, South District, Zhongshan, Guangdong, China.

   Product                         Music Center with Bluetooth

   Brand Name                      Victrola, Innovative Technology

   Model                           VTA-320B
                                   VTA-320B-MAH,VTA-320B-ESP, VTA-320B-FOT, VTA-320B-FNT, VTA-320B-GRY,
   Additional Model &              VTA-320Bxxxx, VSS-320B, VSS-320B-GRY, VSS-320B-ESP, VSS-320B-GRY-CAN,
   Model Difference                VSS-320Bxxxx, ITVS-320B, ITVS-320Bxxxx
                                   (where x can be “0-9”, “A-Z”, “-” or blank and means color code of unit)

   Date of tests                   Mar. 04, 2019 ~ Mar. 26, 2019

        FCC Part 2 (Section 2.1091)
        KDB 447498 D01
        IEEE C95.1

   CONCLUSION: The submitted sample was found to COMPLY with the test requirement

                        Tested by Lucas Chen                                                           Approved by Glyn He
                 Project Engineer / EMC Department                                                  Supervisor/ EMC Department




                                                                                                            Date: Jul. 01, 2019
   This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at
   http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or
   replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This
   report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or
   representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and
   expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us.
   Measurement uncertainty is only provided upon request for accredited tests. You have 60 days from date of issuance of this report to notify us of any
   material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing
   and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute you unqualified
   acceptance of the completeness of this report, the tests conducted and the correctness of the report contents.

                                                    No. 34, Chenwulu Section, Guantai Rd., Houjie              Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                    Town, Dongguan City,                                       Fax: +86 769 8593 1080
Dongguan Branch
                                                    Guangdong 523942, China                                    Email: customerservice.dg@cn.bureauveritas.com
                                                                         Page 1 of 6                                                             Report Version 1


                Test Report No.: FM190304N022

                                          Table of Contents
   RELEASE CONTROL RECORD ................................................................................ 3
   1.       CERTIFICATION .............................................................................................. 4
   2.       RF EXPOSURE LIMIT ..................................................................................... 5
   3.       MPE CALCULATION FORMULA ..................................................................... 5
   4.       CLASSIFICATION ........................................................................................... 5
   5.       ANTENNA GAIN .............................................................................................. 6
   6.       CALCULATION RESULT OF MAXIMUM CONDUCTED POWER................... 6




                                         No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                         Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                         Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                           Page 2 of 6                                                   Report Version 1


                Test Report No.: FM190304N022


                               RELEASE CONTROL RECORD

    ISSUE NO.                REASON FOR CHANGE                                                      DATE ISSUED

    FM190304N022             Original release                                                         Jul. 01, 2019




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 3 of 6                                                    Report Version 1


           OME u_V p.




    BUR$
                    *




                    sv}
           1828



                           Test Report No.: FM190304N022

   1. CERTIFICATION


                                 FCC ID:    2AFHW—VTA320B
                             PRODUCT:       Music Center with Bluetooth
                          BRAND NAME:       Victrola, Innovative Technology
                            MODEL NO.:      VTA—320B
                                            VTA—320B—MAH,VTA—320B—ESP, VTA—320B—FOT, VTA—
                                            320B—FNT, VTA—320B—GRY, VTA—320Bxxxx, VSS—320
                                            B, VSS—320B—GRY, VSS—320B—ESP, VSS—320B—GRY—
                  ADDITIONAL NO.:
                                            CAN, VSS—320Bxxxx, ITVS—320B, ITVS—320Bxxxx
                                            (where x can be "0—9" , "A—Z" , "—" or blank and
                                            means color code of unit)
                           APPLICANT:       Innovative Technology Electronics, LLC

                          STANDARDS:         FCC Part 2 (Section 2.1091)

                                             KDB 447498 DO1

                                             IEEE C95.1




                                             No.  34, Ch Chenwulu
                                              0. 34,           lu Secti
                                                                    Section, Guantai
                                                                               Guantai Rd., Rd., Houji
                                                                                                   Houjie    Tel: +86
                                                                                                            Tel:         76 8998 2098
                                                                                                                    +86 769
Bureau Veritas Shenzhen Co., Ltd.
                                             Town, Dongguan City,                                           Fax: +86 769 8593 1080
Dongguan Branch                                                   .                                               .
                                             Guangdong 523942, China                                        Email: customerservice.dg@cn.bureauveritas.com

                                                                    Page 4 of 6                                                             Report Version 1


                Test Report No.: FM190304N022

   2. RF EXPOSURE LIMIT

   LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
      FREQUENCY             ELECTRIC FIELD         MAGNETIC FIELD POWER DENSITY                           AVERAGE TIME
      RANGE (MHz)           STRENGTH (V/m)         STRENGTH (A/m)   (mW/cm2)                                (minutes)
                    LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE
         300-1500                   …                        …                     F/1500                           30
      1500-100,000                  …                        …                          1.0                         30

   F = Frequency in MHz


   3. MPE CALCULATION FORMULA
   Pd = (Pout*G) / (4*pi*r2)
   where
   Pd = power density in mW/cm2
   Pout = output power to antenna in mW
   G = gain of antenna in linear scale
   Pi = 3.1416
   R = distance between observation point and center of the radiator in cm


   4. CLASSIFICATION
   The antenna of this product, under normal use condition, is at least 20cm away from
   the body of the user. So, this device is classified as Mobile Device.




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie     Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                        Town, Dongguan City,                              Fax: +86 769 8593 1080
Dongguan Branch
                                        Guangdong 523942, China                           Email: customerservice.dg@cn.bureauveritas.com
                                                         Page 5 of 6                                                      Report Version 1


    B U R E A U
    V E R I TA S
                   Test Report No.: FM190304N022


   5. ANTENNA GAIN

         The antennas provided to the EUT, please refer to the following table:
                   Transmitter                                                            Antenna
                       .   I.                   Peak Gain (dBi)
                     Circuit                                                                  Type
                     Chain 0                                0                           PCB Antenna



   6. CALCULATION RESULT OF MAXIMUM CONDUCTED AV POWER
   The tuned conducted Average Power (declared by client)

                                Frequenc             logs                Tolerance               e                     e
         Mode                     (|3|HZ) Y          Power                 (dBm)               Tolerance             Tolerance
                                                     (dBm)                                       (dBm)                 (dBm)
        GFSK                2402—2480                   1                    +—1                     0                     2
       8DPSK                2402—2480                   1                    +—1                     0                     2


   The measured conducted Average Power

                                                       Frequency                                 Averaged Power
                   Mods                                     (MHz)                                        (dBm)
                   GFSK                                     2402                                         1.16
                   8DPSK                                    2441                                         1.07



      FREQUENCY             |MAX AVERAGE|            ANTENNA                                          POWER
        BAND                   POWER                   GAIN                  DIS(-:;fnl;lCE          DENSITY               (mI;I:II\/’I;-rI;nz)
         (MHz)                  (dBm)                  (dBi)                                         (mW/cm*)

        2402—2480                      2                        0                  20                0.000315                     1.0




    ——— END ———




                                              No. 34, Chenwulu Section, Guantai Rd., Houjie      Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                              Town, Dongguan City,                               Fax: +86 769 8593 1080
Dongguan Branch
                                              Guangdong 523942, China                            Email: customerservice.dg@cn.bureauveritas.com

                                                                    Page 6 of 6                                                    Report Version 1



Document Created: 2019-07-12 08:29:21
Document Modified: 2019-07-12 08:29:21

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC