Test Report

FCC ID: 2AFG2-P1

Test Report

Download: PDF
FCCID_2832351

                         Shenzhen Zhongjian Nanfang Testing Co., Ltd.
                                                                                       Report No:CCIS15100082401

1       Cover Page

                              FCC REPORT
                                                           (WIFI)

    Applicant:                          Vimtag Technology Co., Ltd
                                        6F.West, 1st Building, Innovative Industrial Park, Nanshan
    Address of Applicant:               Cloud Valley, No.1183, Liuxian Avenue, Nanshan District, SZ,
                                        CN.
    Equipment Under Test (EUT)

     Product Name:                      Cloud Camera
                                        P1, P1-S, P1-X, P1-C, P2, P2-S, P2-X, P2C, P3, P3-S, P3-X,
    Model No.:
                                        P3-C, P4, P4-S, P4-X, P2-C, P5, P5-S, P5-X, P5-C
     Trade mark:                        Vimtag

    FCC ID:                             2AFG2-P1

    Applicable standards:               FCC CFR Title 47 Part 15 Subpart C Section 15.247

    Date of sample receipt:             29 Oct., 2015

    Date of Test:                       29 Oct., to 02 Dec., 2015

    Date of report issued:              03 Dec., 2015

    Test Result:                        PASS*

*    In the configuration tested, the EUT complied with the standards specified above.



Authorized Signature:




Bruce Zhang
   Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate
to other samples of the same product and does not permit the use of theCCISproduct certification mark. The manufacturer
should ensure that all products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than
that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized
alteration, forgery orfalsification of the content or appearance of this document is unlawful and offenders may be prosecuted
to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested
and such sample(s) are retained for 90 days only.


                                                                                Report No:CCIS15100082401

2      Version

      Version No.                        Date                                   Description
            00                     03 Dec., 2015                                  Original




    Tested by:                                                          Date:           03 Dec., 2015

                                       Test Engineer

    Reviewed by:                                                        Date:           03 Dec., 2015

                                    Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                      Project No.:CCIS151000824RF
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                               Page 2 of 48


                                                                                                                     Report No: CCIS15100082401

3         Contents
                                                                                                                                                                         Page
1       COVER PAGE ....................................................................................................................................................... 1
2       VERSION ............................................................................................................................................................... 2
3       CONTENTS ........................................................................................................................................................... 3
4       TEST SUMMARY .................................................................................................................................................. 4
5       GENERAL INFORMATION .................................................................................................................................. 5
    5.1         CLIENT INFORMATION ............................................................................................................................................ 5
    5.2         GENERAL DESCRIPTION OF E.U.T........................................................................................................................ 5
    5.3         TEST ENVIRONMENT ANDMODE ............................................................................................................................. 7
    5.4         LABORATORY FACILITY.......................................................................................................................................... 7
    5.5         LABORATORY LOCATION ....................................................................................................................................... 7
    5.6         TEST INSTRUMENTS LIST ....................................................................................................................................... 8
6       TEST RESULTS ANDMEASUREMENT DATA ................................................................................................. 9
    6.1     ANTENNA REQUIREMENT: ...................................................................................................................................... 9
    6.2     CONDUCTED EMISSION ....................................................................................................................................... 10
    6.3     CONDUCTED OUTPUT POWER ............................................................................................................................ 13
    6.4     OCCUPY BANDWIDTH .......................................................................................................................................... 15
    6.5     POWER SPECTRAL DENSITY ............................................................................................................................... 18
    6.6     BAND EDGE ......................................................................................................................................................... 20
       6.6.1 Conducted Emission Method...................................................................................................................... 20
       6.6.2 Radiated Emission Method ......................................................................................................................... 22
    6.7     SPURIOUS EMISSION ........................................................................................................................................... 27
       6.7.1 Conducted Emission Method...................................................................................................................... 27
       6.7.2 Radiated Emission Method ......................................................................................................................... 30
7       TEST SETUP PHOTO ........................................................................................................................................ 35
8       EUT CONSTRUCTIONAL DETAILS ................................................................................................................ 37




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                 Project No.:CCIS151000824RF
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                               Page 3 of 48


                                                                                  Report No: CCIS15100082401

4      Test Summary
                         Test Item                                  Section in CFR 47                     Result
                   Antenna requirement                                  15.203/15.247 (c)                  Pass
           AC Power Line Conducted Emission                                  15.207                        Pass
              Conducted Peak Output Power                                 15.247 (b)(3)                    Pass
                 6dB Emission Bandwidth
                                                                          15.247 (a)(2)                    Pass
                 99% Occupied Bandwidth
                  Power Spectral Density                                   15.247 (e)                      Pass
                         Band Edge                                         15.247(d)                       Pass
                    Spurious Emission                                    15.205/15.209                     Pass
    Pass: The EUT complies with the essential requirements in the standard.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.:CCIS151000824RF
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                       Page 4 of 48


                                                                             Report No: CCIS15100082401

5      General Information
5.1 Client Information
        Applicant:                          Vimtag Technology Co., Ltd
        Address of Applicant:               6F.West,1st Building,Innovative Industrial Park,Nanshan      Cloud
                                            Valley, No.1183, Liuxian Avenue, Nanshan District, SZ, CN.
        Manufacturer/ Factory:              Vimtag Technology Co., Ltd
        Address of Manufacturer/            6F.West,1st Building, Innovative Industrial Park, Nanshan Cloud
        Factory:                            Valley, No.1183, Liuxian Avenue, Nanshan District, SZ, CN.

5.2 General Description of E.U.T.
        Product Name:                       Cloud Camera
                                            P1, P1-S, P1-X, P1-C, P2, P2-S, P2-X, P2C, P3, P3-S, P3-X, P3-C,
        Model No.:                          P4, P4-S, P4-X, P2-C, P5, P5-S, P5-X, P5-C
        Operation Frequency:                2412MHz~2462MHz (802.11b)
        Channel numbers:                    11 for 802.11b
        Channel separation:                 5MHz
        Modulation technology:
                                            Direct Sequence Spread Spectrum (DSSS)
        (IEEE 802.11b)
        Modulation technology:
                                            Not supported
        (IEEE 802.11g/802.11n)
        Data speed (IEEE 802.11b):          1Mbps, 2Mbps, 5.5Mbps, 11Mbps
        Data speed (IEEE 802.11g):          Not supported
        Data speed (IEEE 802.11n):          Not supported
        Antenna Type:                       Internal Antenna
        Antenna gain:                       2.5dBi
                                            Model: FJ-SW7260502000UU
        AC adapter:                         Input:100-240V AC,50/60Hz 0.4A
                                            Output:5V DC MAX 2000mA
        Remark:                             Model No.: P1, P1-S, P1-X, P1-C, P2, P2-S, P2-X, P2C, P3, P3-S, P3-
                                            X, P3-C, P4, P4-S, P4-X, P2-C, P5, P5-S, P5-X, P5-C, are electrically
                                            identical , only model no is different .




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                     Project No.:CCIS151000824RF
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                               Page 5 of 48


                                                                             Report No: CCIS15100082401

  Operation Frequency each of channel For 802.11b
   Channel       Frequency        Channel       Frequency       Channel   Frequency   Channel    Frequency
       1          2412MHz             4         2427MHz             7     2442MHz       10           2457MHz
       2          2417MHz             5         2432MHz             8     2447MHz       11           2462MHz
       3          2422MHz             6         2437MHz             9     2452MHz


Note:
In section 15.31(m), regards to the operating frequency range over 10 MHz, the Lowest frequency, the middle
frequency, and the highest frequency of channel were selected to perform the test, and the selected channel
see below:

802.11b
           Channel                        Frequency
     The lowest channel                   2412MHz
     The middle channel                   2437MHz
    The Highest channel                   2462MHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                    Project No.:CCIS151000824RF
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                             Page 6 of 48


                                                                           Report No: CCIS15100082401

5.3 Test environment andmode
 Operating Environment:
     Temperature:                     24.0 C
     Humidity:                        54 % RH
     Atmospheric Pressure:            1010 mbar
 Test mode:
     Operation mode                   Keep the EUT in continuous transmitting with modulation
 The sample was placed 0.8m above the ground plane of 3m chamber. Measurements in both horizontal and
 vertical polarities were performed. During the test, each emission was maximized by: having the EUT
 continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered
 typical configuration to obtain worst position, manipulating interconnecting cables, rotating the turntable,
 varying antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst-case
 are shown in Test Results of the following pages.

 We have verified the construction and function in typical operation. All the test modes were carried out with
 the EUT in transmitting operation, which was shown in this test report and defined as follows:
 Per-scan all kind of data rate in lowest channel, and found the follow list which it was worst case.
                             Mode                                                Data rate
                            802.11b                                               1Mbps
 Final Test Mode:
 According to ANSI C63.4 standards, the test results are both the “worst case” and “worst setup”1Mbps.Duty
 cycle setting during the transmission is100% with maximum power setting for all modulations.

5.4 Laboratory Facility
       The test facility is recognized, certified, or accredited by the following organizations:
       ● FCC - Registration No.: 817957
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. EMC Laboratory has been registered and fully
       described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter
       from the FCC is maintained in out files. Registration 817957, February 27, 2012.
       ● IC - Registration No.: 10106A-1
       The 3m Semi-anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
       Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with
       Registration No.: 10106A-1.
       ● CNAS - Registration No.: CNAS L6048
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
       Requirements for the Competence of Testing and Calibration laboratories for the competence of
       testing. The Registration No. is CNAS L6048.

5.5 Laboratory Location
        Shenzhen Zhongjian Nanfang Testing Co., Ltd.
        Address: No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
        Bao’an District, Shenzhen, Guangdong, China
        Tel: +86-755-23118282
        Fax: +86-755-23116366




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                    Project No.:CCIS151000824RF
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                              Page 7 of 48


                                                                               Report No: CCIS15100082401

5.6 Test Instruments list
Radiated Emission:
                                                                             Inventory      Cal. Date      Cal. Due date
Item     Test Equipment          Manufacturer              Model No.
                                                                                No.        (mm-dd-yy)      (mm-dd-yy)
 1          3m SAC                 SAEMC                9(L)*6(W)* 6(H)      CCIS0001      08-23-2014      08-22-2017
 2     BiConiLog Antenna       SCHWARZBECK                VULB9163           CCIS0005      03-28-2015      03-28-2016
 3       Horn Antenna          SCHWARZBECK               BBHA9120D           CCIS0006      03-28-2015      03-28-2016
          Pre-amplifier
 4                                    HP                    8447D            CCIS0003      04-01-2015      03-31-2016
        (10kHz-1.3GHz)
          Pre-amplifier      Compliance Direction
 5                                                        PAP-1G18           CCIS0011      04-01-2015      03-31-2016
         (1GHz-18GHz)            Systems Inc.
          Pre-amplifier                                  AFS33-18002
 6                            Rohde & Schwarz                                GTS218        04-01-2015      03-31-2016
          (18-26GHz)                                     650-30-8P-44
 7       Horn Antenna          ETS-LINDGREN                  3160            GTS217        04-01-2015      03-31-2016
       Spectrum analyzer
 8                            Rohde & Schwarz               FSP30            CCIS0023      03-28-2015      03-28-2016
           9k-30GHz
 9     EMI Test Receiver      Rohde & Schwarz               ESRP7            CCIS0167      03-28-2015      03-28-2016
10       Loop antenna         Laplace instrument            RF300            EMC0701       04-01-2015      03-31-2016


Conducted Emission:
                                                                              Inventory      Cal. Date     Cal. Due date
Item    Test Equipment           Manufacturer              Model No.
                                                                                No.         (mm-dd-yy)      (mm-dd-yy)
 1      Shielding Room       ZhongShuo Electron      11.0(L)x4.0(W)x3.0(H)   CCIS0061       11-10-2013      11-09-2016
 2     EMI Test Receiver      Rohde & Schwarz                ESCI            CCIS0002       03-28-2015      03-28-2016
 3            LISN                 CHASE                   MN2050D           CCIS0074       03-28-2015      03-28-2016
 4       Coaxial Cable              CCIS                      N/A            CCIS0086       04-01-2015      03-31-2016
 5     EMI Test Software            AUDIX                      E3               N/A            N/A             N/A




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                          Project No.:CCIS151000824RF
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                   Page 8 of 48


                                                                         Report No: CCIS15100082401

6      Test results andMeasurement Data
6.1 Antenna requirement:
        Standard requirement:          FCC Part15 C Section 15.203 /247(c)
      15.203 requirement:
        An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
        responsible party shall be used with the device. The use of a permanently attached antenna or of an
        antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit
        so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or
        electrical connector is prohibited.
        15.247(c) (1)(i) requirement:
        (i) Systems operating in the 2400-2483.5 MHz band that is used exclusively forfixed. Point-to-point
        operations may employ transmitting antennas with directional gain greater than 6dBiprovided the
        maximum conducted output power of the intentional radiator is reduced by 1 dB for every 3dB that the
        directional gain of the antenna exceeds 6dBi.
       E.U.T Antenna:
       The WiFiantenna is an internal antenna which cannot replace by end-user, the best case gain of the
       antenna is 2.5 dBi.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                  Project No.:CCIS151000824RF
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                            Page 9 of 48


                                                                            Report No: CCIS15100082401

6.2 Conducted Emission
        Test Requirement:               FCC Part15 C Section 15.207
        Test Method:                    ANSI C63.4: 2009
        TestFrequencyRange:             150kHz to 30MHz
        Class / Severity:               Class B                 Class B
        Receiver setup:                 RBW=9kHz, VBW=30kHz
        Limit:                                                                         Limit (dBuV)
                                            Frequency range (MHz)
                                                                             Quasi-peak             Average
                                                   0.15-0.5                   66 to 56*             56 to 46*
                                                     0.5-5                       56                    46
                                                     5-30                        60                    50
                                        * Decreases with the logarithm of the frequency.
        Test procedure                  1. The E.U.T and simulators are connected to the main power through
                                            a line impedance stabilization network (L.I.S.N.), whichprovides a
                                            50ohm/50uH coupling impedance for the measuring equipment.
                                        2. The peripheral devices are also connected to the main power
                                            through a LISN that provides a 50ohm/50uH coupling impedance
                                            with 50ohm termination. (Please refer to the block diagram of the
                                            test setup and photographs).
                                        3. Both sides of A.C. line are checked for maximum conducted
                                            interference. In order to find the maximum emission, the relative
                                            positions of equipment and all of the interface cables must be
                                            changed according to ANSI C63.4: 2009 on conducted
                                            measurement.
        Test setup:




        Test Uncertainty:                                                                             ±3.28 dB
        Test Instruments:               Refer to section 5.6 for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Passed

 Measurement Data




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                    Project No.:CCIS151000824RF
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                             Page 10 of 48


UuUI®
              Level (dBuV)
       80

       70

                                                                                                FCC PART15 B OP
       °°\
                                                                                                FCC PART15B AV
       50
                                                                                      11

       40

       30

       w
         10


              0.150.2             0.5            1              2                          10           20        30
  Hace: &                                               Frequency (MHz)

Site                : CCIS Shielding Room
Condition           : FCC PARTIS B QP LISN NEUTR&AL
EUT                 : Cloud Camera
Model               181
Test Mode           : Vifi mode
Power Rating        : AC 120¥/60Hz
Environment   : Temp: 23 °C Huni:56%            Atmos:101KPa
Test Engineer: Viki
Remark              f
                        Read    LISN    Cable           Limit       Over
                Freq    Level Factor     Loss   Level    Line       Linit Remark

                 MHz     dBu¥     dB       db    dBu¥    dBu¥          dB

  1            0.198    28.75   0.25    10.76   39.76   63.71   —23.95      QP
  2            0.479    18.93   0.28    10.75   29.96   46.36   —16.40      Average
  8            0.529    30.75   0.27    10.76   41.78   56.00   —14.22      QP
  4            0.535    26.89   0.27    10.76   37.92   46.00    —8.08      Average
  5            0.558    31.43   0.25    10.77   42.45   56.00   —13.55      QP
  6            0.558    27.84   0.25    10.77   38.86   46.00    —7.14      Average
  T            .708     25.60   0.18    10.77   36.55   56.00   —19.45      qP
  8            0.844    17.55   0.20    10.82   28.57   46.00   —17.43      Average
  9            1.544    14.69   0.26    10.93   25.88   46.00   —20.12      Average
 10            4.598    29.06   0.28    10.86   40.20   56.00   —15.80      QP
 11            6.121    34.30   0.27    10.82   45.39   60.00   —14.61      9P
 12            6.121    16.76   0.27    10.82   27.85   50.00   —22.15      Average


                                                                        Report No: CCIS15100082401

Line:




Notes:
1. An initial pre-scan was performed on the live and neutral lines with peak detector.
2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peakemission.
3. Final Level =Receiver Read level + LISN Factor + Cable Loss




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                               Project No.:CCIS151000824RF
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                       Page 12 of 48


                                                                             Report No: CCIS15100082401

6.3 Conducted Output Power
        Test Requirement:               FCC Part15 C Section 15.247 (b)(3)
        Test Method:                    ANSI C63.10:2009 and KDB558074v03r03 section 9.2.2
        Limit:                          30dBm
        Test setup:




        Test Instruments:               Refer to section 5.6 for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Passed


Measurement Data


                               Maximum Conducted Output Power (dBm)
        Test CH                                                                  Limit(dBm)          Result
                                                  802.11b
         Lowest                                    11.49
         Middle                                    11.21                           30.00             Pass
         Highest                                   10.94



Test plot as follows:




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                    Project No.:CCIS151000824RF
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                            Page 13 of 48


CCIS                                                                               Report No: CCIS15100082401

                                                        Test mode:802.11b

                                                               + eew 1 mite   markee 10(1 ]
                                                               & vew 3 mite               2.34 asm
                Res       30.5 dam      »Ats    40 as            swt 2.5 ms        2.410580000 onz




                    ~so

                    Center 2.412 one                      a mite/                      Span: 40 mite

                    Tx Channel
                    sandwidth                  20 sns          Bower              i1.49 dsn


                                                         Lowest channel

                                                               «Rew 2 rare    Marker 1. [T% )
                                                               avaw o rite                 2.04 asm
              Res     30.5 dBm         aAgs    40 aB            SHT 2.5 ms         2.435e80000 onz




                                                                                                       avi




                                                                                                       sor

              Center 2.437 oxe                            a mire/                        Span 40 mie
               Tx Channel
               Bandwi d th                    20 mxe           Power               11.21 cBm

                                                          Middle channel

                                                               « rew 1 uite   Harker 1 [T1 )
                                                               « vew 3 uie                1.85 don
                    Ree   30.5 dsn      «Ars    40 ds            swt 2.5 as        2.459920000 onz




                    Center 2.462 one                      d vite/                      Span: 40 wie

                     Tx Channel
                     Bandui dth                20 sns          Bower              10.94 dsn


                                                         Highest channel




Shenzhen Zhongfian Nanfang Testing Co., Ltd.                                            Project No.:CCIS151000824RF
No.B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                       Page 14 of 48


                                                                             Report No: CCIS15100082401

6.4 Occupy Bandwidth
        Test Requirement:               FCC Part15 C Section 15.247 (a)(2)
        Test Method:                    ANSI C63.10:2009 and KDB558074v03r03 section 8.1
        Limit:                          >500kHz
        Test setup:




        Test Instruments:               Refer to section 5.6 for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Passed


Measurement Data
                                       6dB Emission Bandwidth (MHz)
            Test CH                                                             Limit(kHz)           Result
                                                    802.11b
            Lowest                                    10.24
             Middle                                   12.24                       >500               Pass
            Highest                                   10.24


                                        99%Occupy Bandwidth (MHz)
            Test CH                                                             Limit(kHz)           Result
                                                    802.11b
            Lowest                                    15.04
             Middle                                   15.04                        N/A                N/A
            Highest                                   15.04


Test plot as follows:




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                    Project No.:CCIS151000824RF
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                            Page 15 of 48


CCIS                                                                            Report No: CCIS15100082401

                                                                6dB EBW
                                                         Test mode: 802.11b




                                 oares S urov.zors ossisi20
                                                              Lowest channel

                                 ®u.<     ma a~




                                 oares Saev.zos. onone
                                                              Middle channel

                                 ® ho     ara   an




                                 nanes saow.onis ngsomsis
                                                              Highest channel


Shenzhen Zhongfian Nanfang Testing Co., Ltd.                                       Project No.:CCIS151000824RF
No.B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                               Page 16 of 48


                                                                                                                                                                 Report No: CCIS15100082401

                                                                                 99% OBW
                                                                     Test mode: 802.11b
                                                                                           * RBW      100      kHz        Marker      1   [T1    ]
                                                                                           * VBW      300      kHz                              0.50      dBm
                                        Ref    30.5    dBm          * Att   40   dB             SWT   5   ms                      2.414000000             GHz

                                        30    Offset    0.5    dB                                                         OBW    15.040000000             MHz
                                                                                                                          Temp    1   [T1    OBW]
                                                                                                                                            -11.75        dBm    A
                                        20
                                                                                                                                  2.404480000             GHz
                                 1 PK
                                                                                                                          Temp    2   [T1    OBW]
                                 MAXH
                                        10                                                                                                  -11.22        dBm   LVL
                                                                                                                                  2.419520000             GHz
                                                                                                 1
                                        0


                                                                    T1                                               T2
                                        -10



                                        -20

                                                                                                                                                                3DB

                                        -30



                                        -40



                                        -50



                                        -60




                                        Center   2.412       GHz                      4   MHz/                                            Span       40   MHz




                                 Date: 5.NOV.2015              03:13:52

                                                                            Lowest channel
                                                                                           * RBW      100      kHz        Marker      1   [T1    ]
                                                                                           * VBW      300      kHz                           -1.01        dBm
                                        Ref    30.5    dBm          * Att   40   dB             SWT   5   ms                      2.435960000             GHz

                                        30    Offset    0.5    dB                                                         OBW    15.040000000             MHz
                                                                                                                          Temp    1   [T1    OBW]
                                                                                                                                            -14.69        dBm    A
                                        20
                                                                                                                                  2.429480000             GHz
                                 1 PK
                                                                                                                          Temp    2   [T1    OBW]
                                 MAXH
                                        10                                                                                                  -12.37        dBm   LVL
                                                                                                                                  2.444520000             GHz

                                                                                      1
                                        0



                                        -10                                                                          T2
                                                                    T1



                                        -20

                                                                                                                                                                3DB

                                        -30



                                        -40



                                        -50



                                        -60




                                        Center   2.437       GHz                      4   MHz/                                            Span       40   MHz




                                 Date: 5.NOV.2015              03:11:10

                                                                            Middle channel
                                                                                           * RBW      100      kHz        Marker      1   [T1    ]
                                                                                           * VBW      300      kHz                           -0.77        dBm
                                        Ref    30.5    dBm          * Att   40   dB             SWT   5   ms                      2.462960000             GHz

                                        30    Offset    0.5    dB                                                         OBW    15.040000000             MHz
                                                                                                                          Temp    1   [T1    OBW]
                                                                                                                                            -14.67        dBm    A
                                        20
                                                                                                                                  2.454400000             GHz
                                 1 PK
                                                                                                                          Temp    2   [T1    OBW]
                                 MAXH
                                        10                                                                                                  -13.89        dBm   LVL
                                                                                                                                  2.469440000             GHz
                                                                                            1
                                        0



                                        -10                                                                      T2
                                                                    T1



                                        -20

                                                                                                                                                                3DB

                                        -30



                                        -40



                                        -50



                                        -60




                                        Center   2.462       GHz                      4   MHz/                                            Span       40   MHz




                                 Date: 5.NOV.2015              03:09:27

                                                                            Highest channel


Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                                                          Project No.:CCIS151000824RF
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                                                  Page 17 of 48


                                                                           Report No: CCIS15100082401

6.5 Power Spectral Density
        Test Requirement:               FCC Part15 C Section 15.247 (e)
        Test Method:                    ANSI C63.10:2009 and KDB558074v03r03 section 10.2
        Limit:                          8dBm
        Test setup:




        Test Instruments:               Refer to section 5.6 for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Passed


Measurement Data


                                      Power Spectral Density (dBm)
         Test CH                                                              Limit(dBm)           Result
                                                   802.11b
          Lowest                                     0.40
          Middle                                     0.30                        8.00              Pass
         Highest                                     0.10


Test plot as follows:




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                  Project No.:CCIS151000824RF
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                          Page 18 of 48


CCIS                                                                            Report No: CCIS15100082401

                                                         Test mode: 802.11b




                                 nanes s wow.onis msnzoze
                                                              Lowest channel




                                 nanes s wow.onis mnsnsser
                                                              Middle channel




                                 oares S .nov.zors o3:08:05
                                                              Highest channel




Shenzhen Zhongfian Nanfang Testing Co., Ltd.                                       Project No.:CCIS151000824RF
No.B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                               Page 19 of 48


                                                                             Report No: CCIS15100082401

6.6 Band Edge
6.6.1 Conducted Emission Method
        Test Requirement:               FCC Part15 C Section 15.247 (d)
        Test Method:                    ANSI C63.10:2009 and KDB558074v03r03 section 13
        Limit:                          In any 100 kHz bandwidth outside the frequency band in which the
                                        spreadspectrum intentional radiator is operating, the radio frequency
                                        power that is produced by the intentional radiator shall be at least 30 dB
                                        below that in the 100 kHz bandwidth within the band that contains the
                                        highest level of the desired power, based on either an RF conducted or a
                                        radiated measurement.
        Test setup:




        Test Instruments:               Refer to section 5.6 for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Passed




Test plot as follows:




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                     Project No.:CCIS151000824RF
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                               Page 20 of 48


                                                                                           Report No: CCIS15100082401


                                                              802.11b

                    %                                           «hew boo wwz   masses i iri   i
                                                                «vew s00 n                —a2.es osn
                         ree   a0.s sen        sars   to os      swt as e           2.322500000. onz




                                                                                     1

                         stace 2.31 ons                   taca m 7                   step 2622 onz




                    Dabe: 27.N0v.2015      22:56:43

                                                         Lowest channel

                    %                                           «mew noo wre   maesee i iri i
                                                                «vew s00 n                —as.27 o8«
                         ree   a0.s sen        sars   to os      sut s ns           rc4212s«000. onz




                         stace 22457 on                   «240 mee /                     stop 2.3 ane




                    Dabe: 5.N0V. 2015     07:57:18

                                                         Highest channel




Shenzhen Zhongfian Nanfang Testing Co., Ltd.                                                      Project No.:CCIS151000824RF
No.B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 21 of 48


                                                                              Report No: CCIS15100082401

6.6.2 Radiated Emission Method
        Test Requirement:               FCC Part15 C Section 15.209 and 15.205
        Test Method:                    ANSI C63.10: 2009and KDB 558074v03r03 section 12.1
        TestFrequencyRange:             2.3GHz to 2.5GHz
        Test site:                      Measurement Distance: 3m
        Receiver setup:
                                             Frequency        Detector     RBW        VBW            Remark
                                                               Peak        1MHz       3MHz         Peak Value
                                          Above 1GHz
                                                               RMS         1MHz       3MHz        Average Value
        Limit:
                                                  Frequency               Limit (dBuV/m @3m)           Remark
                                                                                  54.00             Average Value
                                                  Above 1GHz
                                                                                  74.00               Peak Value
        Test Procedure:                 1.    The EUT was placed on the top of a rotating table 0.8 meters above
                                              the groundat a 3 meter camber. The table was rotated 360 degrees
                                              todetermine the position of the highest radiation.
                                        2.    The EUT was set 3 meters away from the interference-receiving
                                              antenna, whichwas mounted on the top of a variable-height antenna
                                              tower.
                                        3.    The antenna height is varied from one meter to four meters above
                                              the ground to determine the maximum value of the field strength.
                                              Both horizontal and vertical polarizations of the antenna are set to
                                              make the measurement.
                                        4.    For each suspected emission, the EUT was arranged to its worst
                                              case and thenthe antenna was tuned to heights from 1 meter to 4
                                              meters and the rotatablewas turned from 0 degrees to 360 degrees
                                              to find the maximum reading.
                                        5.    The test-receiver system was set to Peak Detect Function and
                                              SpecifiedBandwidth with Maximum Hold Mode.
                                        6.    If the emission level of the EUT in peak mode was 10dB lower than
                                              the limitspecified, then testing could be stopped and the peak values
                                              of the EUT wouldbe reported. Otherwise the emissions that did not
                                              have 10dB margin would bere-tested one by one using peak, quasi-
                                              peak or average method as specified andthen reported in a data
                                              sheet.
        Test setup:




        Test Instruments:               Refer to section 5.6 for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Passed



Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                       Project No.:CCIS151000824RF
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                Page 22 of 48


                                                                            Report No: CCIS15100082401

802.11b
Test channel:Lowest
Horizontal:




Remark:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                     Project No.:CCIS151000824RF
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                              Page 23 of 48


                                                                            Report No: CCIS15100082401

Vertical:




Remark:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                     Project No.:CCIS151000824RF
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                              Page 24 of 48


                                                                            Report No: CCIS15100082401

Test channel:Highest
Horizontal:




Remark:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                     Project No.:CCIS151000824RF
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                              Page 25 of 48


                                                                            Report No: CCIS15100082401

Vertical:




Remark:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                     Project No.:CCIS151000824RF
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                              Page 26 of 48


                                                                             Report No: CCIS15100082401

6.7 Spurious Emission
6.7.1 Conducted Emission Method
        Test Requirement:               FCC Part15 C Section 15.247 (d)
        Test Method:                    ANSI C63.10:2009 and KDB558074 section 11
        Limit:                          In any 100 kHz bandwidth outside the frequency band in which the
                                        spreadspectrum intentional radiator is operating, the radio frequency
                                        power that is produced by the intentional radiator shall be at least 20 dB
                                        below that in the 100 kHz bandwidth within the band that contains the
                                        highest level of the desired power, based on either an RF conducted or a
                                        radiated measurement.
        Test setup:




        Test Instruments:               Refer to section 5.6 for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Passed




Test plot as follows:




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                     Project No.:CCIS151000824RF
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                               Page 27 of 48


c c I s                                                                                      Report No: CCIS15100082401

                                                         Test mode: 802.11b

                                                            Lowest channel

                                                                 sxew aoo k    maswen i (ri a
                                                                 svew 300 es              ca9c60 «en
                           ret    as san          saze   s0 on    sur aus s         13.sea420000 onz
                                 erifecong   on




                           ~ro

                            —eo
                           stace 30 e                       ce                           step 2s on




                      Date: s.%0v.2n15       narrainn
                                                            SOMHz~25GHz



                                                            Middle channel

                                                                 «hew aoo k    maswen i tri a
                                                                 svew 300 es               —a9u70 «en
                           ret    as san          saze   s0 on    sur aus s         13. ri3s¢0000 onz




                           stace 30 mne                     zce                          stop 25 on




                      Dates s.N0v.2n15       nar21:45
                                                            SOMHz~25GHz




Shenzhen Zhongfian Nanfang Testing Co., Ltd.                                                       Project No.:CCIS151000824RF
No.B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 28 of 48


CCIS                                                                              Report No: CCIS15100082401


                                                        Highest channel

                      %                                       sasw 100 e
                                                              svew 300 es       —39.00 can
                           ret   as san        caze   30 ce    sur aus s    tisss0000 onz




                           stace 30 e                    ce                    step 2s on




                      hates s .N0v.2n18   nasaaina
                                                         SOMHz~25GHz




Shenzhen Zhongfian Nanfang Testing Co., Ltd.                                            Project No.:CCIS151000824RF
No.B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                    Page 29 of 48


                                                                              Report No: CCIS15100082401

6.7.2 Radiated Emission Method
        Test Requirement:               FCC Part15 C Section 15.209 and 15.205
        Test Method:                    ANSI C63.10:2009
        TestFrequencyRange:             9kHz to 25GHz
        Test site:                      Measurement Distance: 3m
        Receiver setup:                    Frequency         Detector      RBW        VBW            Remark
                                          30MHz-1GHz        Quasi-peak    120KHz     300KHz      Quasi-peak Value
                                                              Peak         1MHz       3MHz         Peak Value
                                          Above 1GHz
                                                              RMS          1MHz       3MHz        Average Value
        Limit:                                     Frequency             Limit (dBuV/m @3m)          Remark
                                                 30MHz-88MHz                      40.0           Quasi-peak Value
                                                88MHz-216MHz                      43.5           Quasi-peak Value
                                               216MHz-960MHz                      46.0           Quasi-peak Value
                                                 960MHz-1GHz                      54.0           Quasi-peak Value
                                                                                  54.0            Average Value
                                                 Above 1GHz
                                                                                  74.0             Peak Value
        Test Procedure:                 1.    The EUT was placed on the top of a rotating table 0.8 meters above
                                              the groundat a 3 meter chamber.The table was rotated 360 degrees
                                              todetermine the position of the highest radiation.
                                        2.    The EUT was set 3 meters away from the interference-receiving
                                              antenna, whichwas mounted on the top of a variable-height antenna
                                              tower.
                                        3.    The antenna height is varied from one meter to four meters above
                                              the ground to determine the maximum value of the field strength.
                                              Both horizontal and vertical polarizations of the antenna are set to
                                              make the measurement.
                                        4.    For each suspected emission, the EUT was arranged to its worst
                                              case and thenthe antenna was tuned to heights from 1 meter to 4
                                              meters and the rotatablewas turned from 0 degrees to 360 degrees
                                              to find the maximum reading.
                                        5.    The test-receiver system was set to Peak Detect Function and
                                              SpecifiedBandwidth with Maximum Hold Mode.
                                        6.    If the emission level of the EUT in peak mode was 10dB lower than
                                              the limitspecified, then testing could be stopped and the peak values
                                              of the EUT wouldbe reported. Otherwise the emissions that did not
                                              have 10dB margin would bere-tested one by one using peak, quasi-
                                              peak or average method as specified andthen reported in a data
                                              sheet.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                       Project No.:CCIS151000824RF
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                Page 30 of 48


                                                                           Report No: CCIS15100082401

        Test setup:                     Below 1GHz




                                        Above 1GHz




        Test Uncertainty:                                                                           ±4.88 dB
        Test Instruments:               Refer to section 5.6for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Passed
        Remark:                         1. Pre-scan all kind of the place mode (X-axis, Y-axis, Z-axis), and
                                           found the Y-axis is the worst case.
                                        2. 9 kHz to 30MHz is too low, so only shows the data of above 30MHz
                                           in this report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                  Project No.:CCIS151000824RF
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                           Page 31 of 48


c c I s                                                                                Report No: CCIS15100082401

Below 1GHz
Horizontal:
          80Level (dBuVim)


          70

          60
                                                                                                    FCC PART1S CLASS$ B
          50
                                                                    ulg———+——4—a                            2
          40 Lf~ifected—sit

          30

          20

          10


               30             50                   100                200                           500              1000
                                                             Frequency (MHz)

 Site                  : Im chamber
 Condition             : FCC PARTIG CLASS B 3m VULB9163(30M1G) HORIZONTAL
 EUT                   : Cloud Camera
 Model                 B4
 Test mode             : WIFI Mode
 Power Rating          : AC 120¥/60Hz
 Environment           —: Temp:25.5°C  Huni:§5%
 Test Engineer: Viki
 Remark                f
                            Read&ntenna    Cable Preamp             Limit      Over
                    Freq   Level Factor     Loss Factor     Level    Line      Limit Remark

                    MHz     dBu¥   dB/n       dB         dB dBu¥/m dBu¥/m         dB
    1      174.424         59.53    9.29    1.35    29.02   41.15   43.50      —2.35   QP
    2      297.224         52.35   13.00    1.76    28.46   38.65   46.00      —7.35   QP
    $      324.456         50.72   13.53    1.86    28.51   37.60   46.00      —8.40   QP
    4      451.1356        §3.68   16.58    2.26    28.87   42.65   46.00      —3.35   QP
    5      §50.948         §1.91   17.57    2.54    29.10   42.92   46.00      —3.08   QP
    6      651.942         48.05   18.65    2.80    28.77   40.73   46.00      —5.27   QP




Shenzhen Zhongfian Nanfang Testing Co., Ltd.                                                Project No.:CCIS151000824RF
No.B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                        Page 32 of 48


c c I s                                                                                   Report No: CCIS15100082401

Vertical:


                 Level (dBuVim)
            80

            70

            60
                                                                                                       FCC PART1S CLASS$ B




                 30              50                   100                 200                          500              1000
                                                                Frequency (MHz)
 Site                    :   Im chamber
 Condition               :   FCC PARTIS CLASS B 3m VULB9163(30M1G) VERTICAL
 EUT                     :   Cloud Camera
 Model                   i   F1
 Test mode               :   VIFI Mode
 Power Rating            :   AC 1209/60Hz
 Environment             :   Temp:25.5°C   Huni:55%
 Test Engineer: Viki
 Remark                  f
                               Read&ntenna    Cable Preamp              Limit      Over
                      Freq    Level Factor      Loss Factor    Level     Line     Limit Remark

                       NHz     dBu¥   dB/m       dB         dB dBu¥/m dBu¥/m         dB
    1         61.995          50.71   11.90    0.71    29.77    33.55   40.00 —6.45       QP
    2        119.856          51.50   10.48    1.12    29.39    33.71   43.50 —9.79       QP
    3        211.527          §6.53   10.93    i.44    28.76    39.14   43.50 —4.36       QP
    4        249.425          51.59   12.07    1.62    28.54    36.74   46.00 —9.26       QP
    5        426.521          49.26   15.50    2.19    28.83    38.12   46.00 —7.88       qP
    6        480.528          44.97   16.07    2.35    28.92    34.47   46.00 —11.53      QP




Shenzhen Zhongfian Nanfang Testing Co., Ltd.                                                   Project No.:CCIS151000824RF
No.B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                           Page 33 of 48


                                                                                 Report No: CCIS15100082401


Above 1GHz
Test mode: 802.11b                           Test channel: Lowest                  Remark: Peak
                Read           Antenna        Cable     Preamp                                  Over
 Frequency                                                                Level     Limit Line
                Level           Factor        Loss       Factor                                 Limit       Polar.
   (MHz)                                                                (dBuV/m)    (dBuV/m)
               (dBuV)           (dB/m)         (dB)        (dB)                                  (dB)
  4824.00       49.51            31.54        10.58      40.22           51.41        74.00    -22.59      Vertical
  4824.00       49.23            31.54        10.58      40.22           51.13        74.00    -22.87     Horizontal
Test mode: 802.11b                           Test channel: Lowest                  Remark: Average
                Read           Antenna        Cable     Preamp                                  Over
 Frequency                                                                Level     Limit Line
                Level           Factor        Loss       Factor                                 Limit       Polar.
   (MHz)                                                                (dBuV/m)    (dBuV/m)
               (dBuV)           (dB/m)         (dB)        (dB)                                  (dB)
  4824.00       44.42            31.54        10.58      40.22           46.32        54.00     -7.68      Vertical
  4824.00       44.71            31.54        10.58      40.22           46.61        54.00     -7.39     Horizontal



Test mode: 802.11b                           Test channel: Middle                  Remark: Peak
                Read           Antenna        Cable     Preamp                                   Over
 Frequency                                                                Level     Limit Line
                Level           Factor        Loss       Factor                                  Limit      Polar.
   (MHz)                                                                (dBuV/m)    (dBuV/m)
               (dBuV)           (dB/m)         (dB)        (dB)                                   (dB)
  4874.00       49.68            31.57        10.64      40.15           51.74        74.00     -22.26     Vertical
  4874.00       48.68            31.57        10.64      40.15           50.74        74.00     -23.26    Horizontal
Test mode: 802.11b                           Test channel: Middle                  Remark: Average
                Read           Antenna        Cable     Preamp                                   Over
 Frequency                                                                Level     Limit Line
                Level           Factor        Loss       Factor                                  Limit      Polar.
   (MHz)                                                                (dBuV/m)    (dBuV/m)
               (dBuV)           (dB/m)         (dB)        (dB)                                   (dB)
  4874.00       46.04            31.57        10.64      40.15           48.10        54.00      -5.90     Vertical
  4874.00       45.19            31.57        10.64      40.15           47.25        54.00      -6.75    Horizontal



Test mode: 802.11b                           Test channel: Highest                 Remark: Peak
                Read           Antenna        Cable     Preamp                                   Over
 Frequency                                                                Level     Limit Line
                Level           Factor        Loss       Factor                                  Limit      Polar.
   (MHz)                                                                (dBuV/m)    (dBuV/m)
               (dBuV)           (dB/m)         (dB)       (dB)                                    (dB)
  4924.00       49.64            31.61        10.70      40.08           51.87        74.00     -22.13     Vertical
  4924.00       49.68            31.61        10.70      40.08           51.91        74.00     -22.09    Horizontal
Test mode: 802.11b                           Test channel: Highest                 Remark: Average
                Read           Antenna        Cable     Preamp                                   Over
 Frequency                                                                Level     Limit Line
                Level           Factor        Loss       Factor                                  Limit      Polar.
   (MHz)                                                                (dBuV/m)    (dBuV/m)
               (dBuV)           (dB/m)         (dB)       (dB)                                    (dB)
  4924.00       44.36            31.61        10.70      40.08           46.59        54.00      -7.41     Vertical
  4924.00       44.88            31.61        10.70      40.08           47.11        54.00      -6.89    Horizontal

Remark:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                        Project No.:CCIS151000824RF
No.B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong,China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                 Page 34 of 48



Document Created: 2015-12-03 15:14:43
Document Modified: 2015-12-03 15:14:43

© 2024 FCC.report