RF Exposure

FCC ID: 2AFDI-ITCOQ626S

RF Exposure Info

Download: PDF
FCCID_4285254

                                                                                                                                                                                      QAI Laboratories
                                                                                                                                                                                3980 North Fraser Way
                                                                                                                                                                         Burnaby, BC V5J 5K5 Canada




                      ELECTROMAGNETIC COMPATIBILITY TEST REPORT
                                                  PREPARED FOR Intrinsyc Technologies Corporation
                                                            BY QAI LABORATORIES




                                                RF Exposure Evaluation for 15407 (NII) and 15.247 Devices
                            Report Reference Number:                                E10702-1803B
                               Product Tested FCC ID:                            2AFDI-ITCOQ626S
                                 Product Tested ISED :                           9049A-ITCOQ626S
                                Total Number of Pages:                                         3
                                         Date of Issue:                                   30 April 2019

                                  EMC Test Laboratory:                               QAI Laboratories Inc.
                                                        Address:                     3980 North Fraser Way, Burnaby, BC, V5J 5K5 Canada
                                                         Phone:                      (604) 527-8378
                                                           Fax:                      (604) 527-8368

Laboratory Accreditations (per ISO/IEC 17025:2005):




                                          American Association for Laboratory Accreditation Certificate Number: 3657.02
  This report has been completed in accordance with the requirements of ISO/IEC 17025. Test results contained in this report are within the scope of QAI Laboratories ISO/IEC 17025 accreditation. QAI
                         Laboratories authorizes the applicant to reproduce this report provided it is reproduced in its entirety and for the use by the company’s employees only.

                                                          Client:                    Intrinsyc Technologies Corporation
                                                        Address:                     885 Dunsmuir Street – Suite 300, Vancouver, BC, Canada V6C 1N5
                                                         Phone:                      (604) 801-6461
                                                           Fax:                      (604) 801-6417
Applicable Test Standards:


                                         Radio Frequency Devices - Subpart E - Unlicensed National Information Infrastructure Devices - §15.407 - General
  CFR 47 FCC Part 15, Subpart E - 15.407
                                         technical requirements.
                                         Digital Transmission Systems (DTSs), Frequency Hopping Systems (FHSs) and Licence-Exempt Local Area Network
  CFR 47 FCC Part 15, Subpart C - 15.247
                                         (LE-LAN) Devices
                                         Digital Transmission Systems (DTSs), Frequency Hopping Systems (FHSs) and Licence-Exempt Local Area Network
                        RSS-247 Issue 2
                                         (LE-LAN) Devices

                                   RSS-Gen Issue 5 General Requirements for Compliance of Radio Apparatus




                                        Equipment Tested:                            Open-Q 626(TM) SOM 802.11a/b/g/n/ac WiFi + BT/BLE
                                            Model Number:                            2AFDI-ITCOQ626S/9049A-ITCOQ626S
                                              Manufacturer:                          Intrinsyc Technologies Corporation




                                                                                            Page 1 of 3


                                                                                                                                                                                 QAI Laboratories
Client: Intrinsyc Technologies Corporation                                                                                                                                 3980 North Fraser Way
Report: E10702_1803B_ReportDFS(Intrinsyc,OpenQ 626 SOM)_Rev1.0                                                                                                        Burnaby, BC V5J 5K5 Canada




REVISION HISTORY
          Date                               Report Number                                 Revision                                  Description                                           By
     2019 Apr 30                               E10702-1803B                                    1.0                                  Initial Release                                       BB




All previous versions of this report have been superseded by the latest dated revision as listed in the above table. Please dispose of all previous electronic and paper printed revisions accordingly.




REPORT AUTHORIZATION
The data documented in this report is for the equipment 2AFDI-ITCOQ626S/9049A-ITCOQ626S Open-Q 626(TM)
SOM 802.11a/b/g/n/ac WiFi + BT/BLE' provided by Intrinsyc Technologies Corporation. Tests were performed on the
sample equipment as requested by Intrinsyc Technologies Corporation for the purpose of demonstrating compliance with
CFR 47 FCC Part 15, Subpart C - 15.247, CFR 47 FCC Part 15, Subpart E - 15.407, CFR 47 FCC Part 15, Subpart B , RSS-
247 Issue 2, RSS-Gen Issue 5, ICES-003 Issue 6 as agreed upon by Intrinsyc Technologies Corporation as per quotation
18SH05146R1.

Intrinsyc Technologies Corporation is responsible for the tested product configuration, continued product compliance,
and for the appropriate auditing of subsequent products as required. This report may comprise a partial list of tests that
are required for FCC, ISED and/or CE Mark Declaration of Conformity and can only be reproduced by the manufacturer.


This is to certify the following report true and correct to the best of our knowledge.




                                            Tested by Bruce Balston                                                              Written by Bruce Balston
                                                EMC Engineer                                                                        Technical Writer




                                             Approved by Raj Atwal                                                            Reviewed by Parminder Singh
                                               EMC Lab Manager                                                                  Director of EMC Services




                                                                                             Page 2 of 3


                                                                                                                          QAI Laboratories
Client: Intrinsyc Technologies Corporation                                                                          3980 North Fraser Way
Report: E10702_1803B_ReportMPE(Intrinsyc,OpenQ 626 SOM)_Rev1.0                                                 Burnaby, BC V5J 5K5 Canada




3.11 RF Exposure Evaluation
This requirement ensures the Equipment Under Test (EUT) complies with the RF exposure requirements of CFR 47 FCC Part 1.131,
RSS-102 Issue 5, Annex A, 9(d).
FCC Part 1.1310 defines radio frequency radiation exposure limits for General Population/Uncontrolled Exposure within frequency
range 1500 - 100,000 MHz: as 1.0 mW/cm^2.
RSS-102 Section 2.5.2 defines RF exposure evaluation as required if the separation distance between the user and/or bystander and
the device’s radiating element is greater than 20 cm, except when the device operates at or above 300 MHz and below 6 GHz , the
source-based, time-averaged maximum EIRP of the device is equal to or less than 1.31 x 10-2 ƒ^0.6834 W (adjusted for tune-up
tolerance), where ƒ is in MHz. In these cases, the information contained in the RF exposure technical brief may be limited to
information that demonstrates how the EIRP was derived.

RF Exposure Limits
                                                          RSS-102-2.5.2               CFR 47 FCC 1.1310
                      Worst-Case (Lowest)
                                                        Power Density Limit          Power Density Limit
    Band               Frequency in Band
                                                             at 20 cm                     at 20 cm
                             MHz
                                                            mW/cm^2                      mW/cm^2
    2G4                        2400                              2.7                          1.0
   UNII-1                      5150                              4.5                          1.0
  UNII-2A                      5250                              4.6                          1.0
  UNII-2C                      5470                              4.7                          1.0
  UNII-3                       5725                              4.8                          1.0

RF Exposure Evaluation
                                      Power Density (mW/cm^2) = EIRP(mW) / (4 * PI * r^2)

                        Highest Measured                                                                         Power Density
                                                           Antenna Gain                      EIRP
    Band                Conducted Power                                                                             at 20 cm
                                                               dBi                           mW
                              dBm                                                                                  mW/cm^2
    2G4                        20.8                             3.32                         259.1                     0.052
   UNII-1                      20.1                             6.11                         421.2                     0.084
  UNII-2A                      20.1                             6.11                         421.2                     0.084
  UNII-2C                      20.1                             6.11                         421.2                     0.084
  UNII-3                       20.1                             6.11                         421.2                     0.084

In all cases, the Power Density reported is significantly less than the applicable limits.

The measurements and calculations for RF Exposure were performed on March 5, 2019 and the EUT complies with CFR 47 FCC Part 1.131 and
RSS-102 Issue 5, Annex A, 9(d).